Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Anal Chem ; 95(30): 11410-11419, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37468434

ABSTRACT

A fluorescent sensor that allows simultaneous analysis of environmental factors in a limited cellular space is useful for understanding precise molecular interactions in live cells and their biological responses. Macropinocytosis is a ubiquitous endocytic pathway for massive uptake of extracellular fluids, resulting in the formation of macropinosomes. Although macropinocytosis may impact intracellular delivery and cancer proliferation, information on the intracellular behaviors of macropinosomes is limited. Here, we aimed to develop a macropinoscope, a sensor that simultaneously detects pH and cathepsin B activity in individual macropinosomes. A macropinosome-specific marker, dextran (70 kDa), was employed as a platform, onto which fluorescein, Oregon Green, and tetramethylrhodamine were loaded for ratiometric pH sensing and imaging. A cathepsin-B-cleavable peptide sequence bearing sulfo-Cy5 and the quencher BHQ-3 was also mounted; cleavage of the sequence was detected as an increase in sulfo-Cy5 fluorescence. A steep decrease in pH was observed 5-10 min after macropinosome formation, which was accompanied by an immediate increase in cathepsin B activity. Our design concept will lead to the development of other macropinoscopes for the simultaneous detection of other parameters in individual macropinosomes.


Subject(s)
Cathepsin B , Endosomes , Cathepsin B/metabolism , Endosomes/metabolism , Pinocytosis/physiology , Hydrogen-Ion Concentration
2.
Chembiochem ; 23(19): e202200319, 2022 10 06.
Article in English | MEDLINE | ID: mdl-35929606

ABSTRACT

Fluorescent cathepsin probes were prepared by modification of peptidic substrates for cathepsin B (CTSB) and cathepsin D (CTSD) with FRET pairs. Fluorophores with distinguishable emission characteristics were applied to CTSB and CTSD probes with their appropriate quenchers to simultaneously monitor the activity of CTSB and/or CTSD. Conjugation of both the CTSB and CTSD probes with short single-stranded DNA drastically increased their reactivity to cathepsins over the parent probes possibly by improving their solubility. The activity of CTSB and CTSD were simultaneously detected by using these orthogonal FRET-based cathepsin probes.


Subject(s)
Cathepsin B , Cathepsin D , Cathepsin B/genetics , Cathepsin B/metabolism , Cathepsin D/genetics , Cathepsin D/metabolism , DNA, Single-Stranded , Fluorescence Resonance Energy Transfer
SELECTION OF CITATIONS
SEARCH DETAIL