Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Nat Commun ; 14(1): 8301, 2023 Dec 14.
Article in English | MEDLINE | ID: mdl-38097606

ABSTRACT

Receptor proteins, such as epidermal growth factor receptor (EGFR), interact with other proteins in the extracellular region of the cell membrane to drive intracellular signalling. Therefore, analysis of extracellular protein-protein interactions (exPPIs) is important for understanding the biological function of receptor proteins. Here, we present an approach using a proximity biotinylation enzyme (AirID) fusion fragment of antigen binding (FabID) to analyse the proximity exPPIs of EGFR. AirID was C-terminally fused to the Fab fragment against EGFR (EGFR-FabID), which could then biotinylate the extracellular region of EGFR in several cell lines. Liquid Chromatography-Mass Spectrometry (LC-MS/MS) analysis indicated that many known EGFR interactors were identified as proximity exPPIs, along with many unknown candidate interactors, using EGFR-FabID. Interestingly, these proximity exPPIs were influenced by treatment with EGF ligand and its specific kinase inhibitor, gefitinib. These results indicate that FabID provides accurate proximity exPPI analysis of target receptor proteins on cell membranes with ligand and drug responses.


Subject(s)
ErbB Receptors , Tandem Mass Spectrometry , Phosphorylation , Chromatography, Liquid , Ligands , ErbB Receptors/metabolism , Epidermal Growth Factor/metabolism
2.
Biochem Biophys Res Commun ; 592: 54-59, 2022 02 12.
Article in English | MEDLINE | ID: mdl-35030423

ABSTRACT

Proteins and antibodies labeled with biotin have been widely used for protein analysis, enzyme immunoassays, and diagnoses. Presently, they are prepared using either a chemical reaction involving a biotin N-hydroxysuccinimide (NHS) ester compound or by enzymatic biotin ligation using a combination of a biotinylation-peptide tag and Escherichia coli BirA. However, these methods are relatively complicated. Recently BirA was improved to TurboID, a highly active enzyme for proximity labeling with biotin. Here, we demonstrate a novel simple biotin labeling method for proteins and antibodies using TurboID. Purified TurboID was mixed with a protein or an antibody in the presence of biotin and ATP in the general biochemical buffer condition, followed by biotin labeling. Biotin labeling sites by TurboID were found on the surface of green fluorescent protein. Biotin labeling of IκBα by TurboID indicated its binding to RelA. Furthermore, TurboID-dependent biotin labeling of monoclonal antibodies from rabbits and mice could be directly used for immunoblotting detection of specific proteins without the purification step. These results indicate that TurboID provides a very useful and simple method for biotin labeling of functional proteins.


Subject(s)
Antibodies/metabolism , Biotin/metabolism , Staining and Labeling/methods , Biotinylation , Green Fluorescent Proteins/metabolism , NF-KappaB Inhibitor alpha/metabolism , Protein Binding
3.
Sci Rep ; 9(1): 19349, 2019 12 18.
Article in English | MEDLINE | ID: mdl-31852950

ABSTRACT

Antibodies are widely used for the detection of specific molecules such as peptides, proteins, and chemical compounds. The specificity of an antibody is therefore its most important feature. However, it is very difficult to confirm antibody specificity. Recently, we made a human protein array consisting of 19,712 kinds of recombinant human proteins produced by a wheat cell-free protein production system. Here, we demonstrate a novel protein array technology for antibody validation (CF-PA2Vtech). Full-length human cDNAs were fused to N-terminal FLAG-GST and then synthesized by the wheat cell-free system. To construct a 20 K human protein array, about 10 to 14 kinds of human proteins were mixed and captured in each well by glutathione-conjugated magnetic beads in 12 plates or one plate with 384- or 1536-well format, respectively, using a strong magnetic device. Using this protein array plate, commercially available anti-HA or anti-PD-1 antibody reacted to 13 or three human proteins, respectively. The cross-reactivity of these proteins was also confirmed by immunoblotting. These proteins have a similar epitope, and alanine mutations of these epitope candidates dissolved the reactivity. These results indicated that CF-PA2Vtech is very useful for validation of antibodies against human protein.


Subject(s)
Antibodies/metabolism , Protein Array Analysis , Proteins/metabolism , Antigens/metabolism , Clone Cells , Cross Reactions , HEK293 Cells , Humans , Programmed Cell Death 1 Receptor/immunology , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...