Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Publication year range
1.
PLoS One ; 12(10): e0185874, 2017.
Article in English | MEDLINE | ID: mdl-29023521

ABSTRACT

BACKGROUND: To investigate the success rate of eye drop instillation in glaucoma patients with visual field defect as well as non-glaucoma volunteers. Factors that may affect the success rate of eye drop instillation were also evaluated. DESIGN: A prospective, observational study. PARTICIPANTS: Seventy-eight glaucoma patients and 85 non-glaucoma volunteers were recruited in this study. METHODS: Open angle glaucoma patients with visual field defect as well as non-glaucoma volunteers were asked to video record their procedures of eye drop instillation using a 5-mL plastic bottle of artificial tear solution. Success of eye drop instillation was judged on video based on the first one drop of solution successfully applied on the cornea, by two investigators. MAIN OUTCOME MEASURES: Success rate of eye drop instillation in glaucoma patients and non-glaucoma volunteers. Factors related to success rate of eye drop instillation, such as visual field defect and clinical characteristics, were also analyzed using multivariable logistic regression. RESULTS: No significant deference in mean age was observed between two groups (glaucoma: 64.5 ± 14.4 years, non-glaucoma: 60.9 ± 14.1 years, P = 0.1156). Success rate of eye drop instillation was significantly lower (P = 0.0215) in glaucoma patients (30/78; 38.5%) than in non-glaucoma volunteers (48/85; 56.5%). The most frequent reason of instillation failure in glaucoma patients was touching the bulbar conjunctiva, cornea, eyelid or eyelashes with the tip of the bottle (29.5%). Multivariable logistic regression analysis identified lower corrected visual acuity (VA) (≤ 1.0; odds ratio [OR] = 0.20, 95% confidence interval [CI] 0.04-0.93, P = 0.0411), lower mean deviation (MD) (< -12 dB; OR = 0.20, 95% CI 0.05-0.86, P = 0.0307) and visual field defect (VFD) in the inferior hemifield (OR = 0.11, 95% CI 0.02-0.34, P < 0.001) to be significantly related to instillation failure in glaucoma patients. CONCLUSIONS: Success rate of eye drop instillation was significantly lower in glaucoma patients than in non-glaucoma volunteers. Corrected VA ≤ 1.0, MD < -12 dB and/or VFD in the inferior hemifield may be related to failure of eye drop instillation.


Subject(s)
Glaucoma, Open-Angle , Ophthalmic Solutions/administration & dosage , Vision Disorders , Aged , Female , Glaucoma, Open-Angle/drug therapy , Glaucoma, Open-Angle/physiopathology , Humans , Male , Middle Aged , Prospective Studies , Vision Disorders/drug therapy , Vision Disorders/physiopathology
2.
No To Shinkei ; 55(8): 705-8, 2003 Aug.
Article in Japanese | MEDLINE | ID: mdl-13677305

ABSTRACT

Recently, patent foramen ovale(PFO) has been highlighted as an important risk factor of cerebral infarctions in young adults. We report a patient of multiple cerebral embolism associated with PFO and deep venous thrombosis caused by a uterine myoma. A 40-year-old woman suddenly suffered from right hemiparesis with motor aphasia. Brain angiography showed an occlusion of M2 portion of the left middle cerebral artery, but atherosclerotic changes were not seen. She developed left facial paresis 23 days later and admitted to our hospital. Brain MRI revealed multiple cerebral infarcts in the left insular cortex, the deep white matter of the right frontal lobe, and bilateral thalamus. Hypoxia with the perfusion defects of S1 and S2 sections of the right lung demonstrated by scintigraphy suggested pulmonary embolism. Transesophageal echocardiography showed a PFO with spontaneous left-to-right shunt and right-to-left shunt evoked by the Valsalva maneuver. Although venography could not detect thrombi, it revealed severe compression of the right external iliac vein by a uterine myoma. These findings suggested thrombi in the right external iliac vein were the embolic source when combined with elevated coagulation markers. An uterine myoma should be considered as an important risk factor for an embolic source in case of cerebral embolism with PFO.


Subject(s)
Heart Septal Defects, Atrial/complications , Intracranial Embolism/etiology , Leiomyoma/classification , Uterine Neoplasms/complications , Adult , Female , Heart Septal Defects, Atrial/surgery , Humans , Intracranial Embolism/diagnosis , Leiomyoma/surgery , Magnetic Resonance Imaging , Uterine Neoplasms/surgery
SELECTION OF CITATIONS
SEARCH DETAIL