Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Catheter Cardiovasc Interv ; 94(5): 669-676, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-30866153

ABSTRACT

OBJECTIVES: To demonstrate coronary sinus (CS) retrograde catheterization as a practicable technique for delivering biologics into the heart. BACKGROUND: There are many options to deliver biologics into the heart. However, there is no single optimal technique when considering safety, biologic retention, and reproducibility. Retrograde delivery has the potential to address many of these concerns. This study evaluated retrograde CS infusion of luciferase-expressing plasmid in a porcine model using the Advance® CS Coronary Sinus Infusion Catheter and bioluminescence imaging to track the expression of the infused biological markers. METHODS: Plasmid was delivered retrograde into the CS in one of three infusion volumes. Twenty-four hours post-infusion, hearts were excised and underwent bioluminescence imaging to characterize the expression of the infusates. Heart and lung biopsies were also assessed for luciferase expression using RT-qPCR. RESULTS: Retrograde infusion was safe and successful in all nine test subjects. Luciferase detection was inconsistent in the low volume group. Bioluminescence was confined predominantly along the posterolateral left ventricle for medium volume infusions and was more broadly dispersed along the anterior side of the heart for high volume infusions. Tissue mRNA analysis corroborated the bioluminescence results, with the highest concentration of luciferase expression localized in the left ventricle. CONCLUSIONS: Retrograde CS infusion is a promising technique for delivering biological molecules to the heart. Specifically, this study demonstrated that the low pressure coronary venous system accommodates a wide range of infusion volumes and that biological infusates can be maintained in situ following the resumption of coronary venous flow.


Subject(s)
Cardiac Catheterization , Coronary Sinus , Gene Transfer Techniques , Luciferases/administration & dosage , Plasmids/administration & dosage , Animals , Infusions, Intravenous , Luciferases/biosynthesis , Luciferases/genetics , Luminescent Measurements , Models, Animal , Myocardium/metabolism , Plasmids/biosynthesis , Plasmids/genetics , RNA, Messenger/biosynthesis , Sus scrofa , Time Factors
2.
J Vasc Interv Radiol ; 18(9): 1169-75, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17804781

ABSTRACT

PURPOSE: To compare two techniques used to create a larger animal model of venous valve incompetence. MATERIALS AND METHODS: To achieve vein dilatation as the primary cause of valve incompetence, common carotid jugular vein (JV) fistulas were created and optional filters were placed into the JV of sheep. Altogether, nine inferior vena cava filters were placed in three sheep in two stages. Six filters were placed caudal to the most caudal JV valve in three sheep and removed 6 weeks later. Then, three filters were placed across the most caudal valve in two sheep with competent valves and removed 3 weeks later. A common carotid artery-JV fistula was created in three sheep and followed-up for 1-3 weeks. Ascending and descending venograms were obtained to determine the JV sizes and function of their valves. The JVs removed at necropsy were studied with venoscopy. RESULTS: Only one of the six JVs with filters caudal to the most caudal valve had incompetent valves after filter removal at 6 weeks. In addition, only one of three JVs with the filter across the valve had incompetent valves after filter removal at 3 weeks. At 1-3-week follow-up of the group with common carotid artery-JV fistula, all three JVs had incompetent valves in the cephalad vein portion, but only one JV had an incompetent valve in its caudal portion. At venoscopy, the incompetent valves showed various degrees of damage ranging from shortening to the destruction of valve leaflets. CONCLUSION: Dilation of the valve annulus with a removable vena cava filter failed to produce valve incompetence. The promising results with the common carotid artery-JV fistula justify further detailed research.


Subject(s)
Disease Models, Animal , Venous Thrombosis/diagnostic imaging , Venous Thrombosis/physiopathology , Animals , Female , Pilot Projects , Radiography , Sheep
SELECTION OF CITATIONS
SEARCH DETAIL
...