1.
Heart Rhythm ; 2024 Oct 07.
Article in English | MEDLINE | ID: mdl-39383980

ABSTRACT

BACKGROUND: To predict worsening heart failure hospitalizations (WHFHs), the HeartInsight multiparametric algorithm calculates a Heart Failure (HF) Score based on temporal trends of physiologic parameters obtained through automatic daily remote monitoring of implantable cardioverter-defibrillators (ICDs). OBJECTIVE: We studied the association of the baseline HF Score (BHFScore), determined at algorithm activation, with long-term patient outcomes. METHODS: Data from nine clinical trials were pooled, including 1,841 ICD patients with a pre-implant ejection fraction ≤35%, NYHA class II/III, and no long-standing atrial fibrillation. Primary endpoint was a composite of death or WHFH. RESULTS: After a median follow-up of 631 days (interquartile range, 385-865), there were 243 WHFHs in 173 patients (9.4%) and 122 deaths (6.6%), 52 of which (42.6%) were cardiovascular. Primary endpoint occurred in 265 patients (14.4%). A multivariable time-to-first event analysis showed that a high BHFScore (>23, as determined by a time-dependent receiver operating characteristics curve analysis) was significantly associated with the occurrence of primary endpoint (adjusted hazard ratio [HR], 2.05; 95%-confidence interval [CI], 1.54-2.71; p<0.0001), all-cause death (HR, 2.37; CI, 1.56-3.58; p<0.0001), cardiovascular death (HR, 2.19; CI, 1.14-4.22; p=0.019), and WHFH (HR, 1.91; CI, 1.35-2.71; p=0.0003). In a hierarchical event analysis of all-cause death as the outcome with highest priority and WHFHs as repeated-event outcomes, the win-ratio was 2.47 (CI, 1.89-3.24; p<0.0001). CONCLUSIONS: Based on a retrospective analysis of clinical trial data with adjudicated events, baseline HF Score derived from device-monitored variables was able to stratify patients at higher long-term risk of death or WHFH.

2.
Heart Vessels ; 2024 Sep 21.
Article in English | MEDLINE | ID: mdl-39305318

ABSTRACT

Atrial fibrillation (AF) is a common cardiac arrhythmia, with structural and electrical remodeling being significant risk factors for recurrence post-catheter ablation. The advent of high-power short-duration pulmonary vein isolation (HPSD-PVI) presents a novel approach, potentially enhancing procedural success rates through the creation of transmural lesions without overheating. This study investigates the predictors of atrial tachyarrhythmia (ATA) recurrence and compares outcomes between HPSD-PVI and conventional PVI techniques. A total of 1005 patients undergoing radiofrequency catheter ablation (RFA) for AF were retrospectively analyzed in this study. The cohort was divided based on the ablation strategy: conventional PVI from February 2013 to September 2018, and HPSD-PVI from October 2018 onwards. The primary objective was to compare the predictors of ATA recurrence and the outcome between the two groups. Among 969 patients analyzed after exclusions, independent predictors of recurrence differed between groups; higher CHADS2/CHA2DS2-VASc scores and lower left ventricular ejection fraction (LVEF) were significant in the HPSD-PVI group, while non-paroxysmal AF, larger left atrial volume index (LAVI), and longer AF history were predictors in the conventional PVI group. The HPSD-PVI group showed a trend toward lower ATA recurrence rates compared to the conventional PVI group in the propensity-score-matched (PSM) cohort (log-rank test, p = 0.06). Higher CHADS2/CHA2DS2-VASc scores and lower LVEF were also independent predictors of ATA recurrence in the PSM cohort.

3.
Heart Rhythm ; 2024 Sep 27.
Article in English | MEDLINE | ID: mdl-39343120

ABSTRACT

In a pivotal trial (NCT05252702), the AVEIR DR (Abbott) leadless pacemaker system was found to be safe and effective in delivering DDDR synchronous atrial and ventricular pacing. This dual-chamber system employs 2 leadless pacemakers with implant-to-implant communication. Although implantation of the ventricular device as a single-chamber pacemaker has been well described, there are additional considerations surrounding the dual-chamber implantation procedure. Herein, we review the dual-chamber leadless pacemaker implantation workflow while providing guidance to optimize safe and effective implantation procedures.

4.
Pacing Clin Electrophysiol ; 47(10): 1293-1299, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39161131

ABSTRACT

BACKGROUND: Transvenous lead extraction (TLE) for cardiovascular implantable electronic device (CIED)-related infections has increased. The incidence of TLE in nonagenarians is low, with limited reports outlining the outcomes of this procedure. Therefore, in this study, we aimed to clarify the outcomes of TLE in nonagenarians. METHODS: Patients with TLE treated at our hospital between 2014 and 2023 were retrospectively examined; patient characteristics, device type, indications, procedures, complications, and clinical data of nonagenarians were analyzed. RESULTS: Of 12 patients with 24 leads (active fixation lead, n = 11; passive fixation lead, n = 13) who underwent TLE, the indication for TLE was infection (pocket infection, n = 8; sepsis, n = 4). Methicillin-resistant Staphylococcus epidermidis was the most frequently identified causative agent (n = 4). The median patient age was 91 years; five patients were female. The median lead dwell time was 9 years. Excimer laser sheath (16 leads), mechanical sheath (five leads), Evolution RL (one lead), and manual traction (two leads) were employed in TLE. The procedure was successful in all patients, and only one had a minor complication. Six patients required CIED re-implantation, and leadless pacemakers were selected for five patients. The 30-day mortality after TLE was 0%. CONCLUSION: TLE can be safely performed in nonagenarians. The decision to perform TLE should not be based on old age alone; the suitability of removing infected CIEDs should be determined based on each patient's condition.


Subject(s)
Defibrillators, Implantable , Device Removal , Pacemaker, Artificial , Prosthesis-Related Infections , Humans , Female , Male , Retrospective Studies , Aged, 80 and over , Prosthesis-Related Infections/etiology , Treatment Outcome
5.
Heart Vessels ; 2024 Aug 31.
Article in English | MEDLINE | ID: mdl-39215819

ABSTRACT

Heart failure (HF) is a complex, heterogeneous syndrome with several comorbidities, often life-threatening and requires urgent therapy. In HF, metabolic alterations that can be assessed using comprehensive plasma, and tissue profiling will help establish new biomarkers and therapeutic targets. Metabolomic analysis of sudden death in HF cases remains unresolved. We prospectively evaluated 19 patients who underwent implantable cardioverter defibrillator (ICD) placement for the primary prevention of sudden cardiac death (SCD). Metabolomic analysis was performed using plasma samples before ICD implantation. Ventricular arrhythmia (VA)/SCD was defined as VA with an appropriate ICD therapy or SCD. During a median follow-up of 29 months (range, 13-35 months), four patients developed VA and one patient developed SCD. Using metabolomic analysis, arginine, lysine, and valine were significantly reduced in patients with VA/SCD (n = 5) compared with those without VA/SCD (n = 14). The molecules involved in energy metabolism might be associated with VA/SCD, thus requiring further investigation as a predictive value of metabolomic analysis of VA/SCD.

6.
Circulation ; 150(6): 439-450, 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-38973458

ABSTRACT

BACKGROUND: A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of atrioventricular synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between atrioventricular synchrony and i2i success, posture/activity, implantation indication, atrioventricular event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean atrioventricular synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrial-to-ventricular i2i (94%) and ventricular-to-atrial i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. Atrioventricular synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, atrioventricular paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated atrioventricular synchrony in 98% of evaluable beats at 3 months after implantation. Atrioventricular synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.


Subject(s)
Pacemaker, Artificial , Humans , Male , Female , Aged , Prospective Studies , Aged, 80 and over , Heart Rate , Electrocardiography, Ambulatory , Middle Aged , Cardiac Pacing, Artificial/methods
7.
J Arrhythm ; 40(3): 639-642, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38939789

ABSTRACT

A 26-year-old man with long QT syndrome (LQTS) underwent subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation. The patient exhibited sinus bradycardia relative to his age. The heart rate decreased, and the QT interval became longer with the administration of ß-blockers, the first-line therapy for LQTS. The patient experienced frequent S-ICD discharges. Subsequently, a single-chamber pacemaker was implanted, and the 12-lead electrocardiogram showed atrial pacing and ventricular sensing at 60 beats per minute with a shorter QTc interval. After converting to "double-device therapy," the patient did not experience any ventricular arrhythmia events.

8.
J Arrhythm ; 40(3): 423-433, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38939793

ABSTRACT

Background: Despite the positive impact of implantable cardioverter defibrillators (ICDs) and wearable cardioverter defibrillators (WCDs) on prognosis, their implantation is often withheld especially in Japanese heart failure patients with reduced left ventricular ejection fraction (HFrEF) who have not experienced ventricular tachycardia (VT) or ventricular fibrillation (VF) for uncertain reasons. Recent advancements in heart failure (HF) medications have significantly improved the prognosis for HFrEF. Given this context, a critical reassessment of the treatment and prognosis of ICDs and WCDs is essential, as it has the potential to reshape awareness and treatment strategies for these patients. Methods: We are initiating a prospective multicenter observational study for HFrEF patients eligible for ICD in primary and secondary prevention, and WCD, regardless of device use, including all consenting patients. Study subjects are to be enrolled from 31 participant hospitals located throughout Japan from April 1, 2023, to December 31, 2024, and each will be followed up for 1 year or more. The planned sample size is 651 cases. The primary endpoint is the rate of cardiac implantable electronic device implementation. Other endpoints include the incidence of VT/VF and sudden death, all-cause mortality, and HF hospitalization, other events. We will collect clinical background information plus each patient's symptoms, Clinical Frailty Scale score, laboratory test results, echocardiographic and electrocardiographic parameters, and serial changes will also be secondary endpoints. Results: Not applicable. Conclusion: This study offers invaluable insights into understanding the role of ICD/WCD in Japanese HF patients in the new era of HF medication.

9.
Cardiovasc Diabetol ; 23(1): 224, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38943159

ABSTRACT

BACKGROUND: Sodium-glucose cotransporter 2 (SGLT2) inhibitors reduce the risk of hospitalization for heart failure and cardiovascular death with type 2 diabetes; however, their effect on arrhythmias is unclear. The purpose of this study was to investigate the effects of empagliflozin on ventricular arrhythmias in patients with type 2 diabetes. METHODS: A total of 150 patients with type 2 diabetes who were treated with an implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator (ICD/CRT-D) were randomized to once-daily empagliflozin or placebo for 24 weeks. The primary endpoint was the change in the number of ventricular arrhythmias from the 24 weeks before to the 24 weeks during treatment. Secondary endpoints included the change in the number of appropriate device discharges and other values. RESULTS: In the empagliflozin group, the number of ventricular arrhythmias recorded by ICD/CRT-D decreased by 1.69 during treatment compared to before treatment, while in the placebo group, the number increased by 1.79. The coefficient for the between-group difference was - 1.07 (95% confidence interval [CI] - 1.29 to - 0.86; P < 0.001). The change in the number of appropriate device discharges during and before treatment was 0.06 in the empagliflozin group and 0.27 in the placebo group, with no significant difference between the groups (P = 0.204). Empagliflozin was associated with an increase in blood ketones and hematocrit and a decrease in blood brain natriuretic peptide and body weight. CONCLUSIONS: In patients with type 2 diabetes treated with ICD/CRT-D, empagliflozin reduces the number of ventricular arrhythmias compared with placebo. Trial registration jRCTs031180120.


Subject(s)
Benzhydryl Compounds , Defibrillators, Implantable , Diabetes Mellitus, Type 2 , Electric Countershock , Glucosides , Sodium-Glucose Transporter 2 Inhibitors , Humans , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/blood , Diabetes Mellitus, Type 2/drug therapy , Glucosides/therapeutic use , Glucosides/adverse effects , Benzhydryl Compounds/therapeutic use , Benzhydryl Compounds/adverse effects , Male , Sodium-Glucose Transporter 2 Inhibitors/therapeutic use , Sodium-Glucose Transporter 2 Inhibitors/adverse effects , Female , Aged , Middle Aged , Treatment Outcome , Time Factors , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Double-Blind Method , Japan , Cardiac Resynchronization Therapy/adverse effects , Blood Glucose/metabolism , Blood Glucose/drug effects
10.
Heart Rhythm ; 21(10): 1914-1922, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38762820

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators last longer, and interest in reliable leads with targeted lead placement is growing. The OmniaSecure defibrillation lead is a novel, small-diameter, catheter-delivered lead designed for targeted placement, based on the established SelectSecure SureScan MRI Model 3830 lumenless pacing lead platform. OBJECTIVE: This trial assessed safety and efficacy of the OmniaSecure defibrillation lead. METHODS: The worldwide LEADR pivotal clinical trial enrolled patients indicated for de novo implantation of a primary or secondary prevention implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator, all of whom received the study lead. The primary efficacy end point was successful defibrillation at implantation per protocol. The primary safety end point was freedom from study lead-related major complications at 6 months. The primary efficacy and safety objectives were met if the lower bound of the 2-sided 95% credible interval was >88% and >90%, respectively. RESULTS: In total, 643 patients successfully received the study lead, and 505 patients have completed 12-month follow-up. The lead was placed in the desired right ventricular location in 99.5% of patients. Defibrillation testing at implantation was completed in 119 patients, with success in 97.5%. The Kaplan-Meier estimated freedom from study lead-related major complications was 97.1% at 6 and 12 months. The trial exceeded the primary efficacy and safety objective thresholds. There were zero study lead fractures and electrical performance was stable throughout the mean follow-up of 12.7 ± 4.8 months (mean ± SD). CONCLUSION: The OmniaSecure lead exceeded prespecified primary end point performance goals for safety and efficacy, demonstrating high defibrillation success and a low occurrence of lead-related major complications with zero lead fractures.


Subject(s)
Defibrillators, Implantable , Humans , Male , Female , Middle Aged , Treatment Outcome , Aged , Reproducibility of Results , Follow-Up Studies , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Equipment Design
11.
Heart Rhythm ; 21(10): 1929-1938, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38697271

ABSTRACT

BACKGROUND: The first dual-chamber leadless pacemaker (DC-LP) system consists of 2 separate atrial and ventricular devices that communicate to maintain synchronous atrioventricular pacing and sensing. The initial safety and efficacy were previously reported. OBJECTIVE: The purpose of this study was to evaluate the chronic electrical performance of the DC-LP system. METHODS: Patients meeting standard dual-chamber pacing indications were enrolled and implanted with the DC-LP system (Aveir DR, Abbott), including right atrial and ventricular helix-fixation LPs (atrial leadless pacemaker [ALP], ventricular leadless pacemaker [VLP]). Pacing capture threshold, sensed amplitude, and pacing impedance were collected using the device programmer at prespecified timepoints from 0-6 months postimplant. RESULTS: De novo devices were successfully implanted in 381 patients with complete 6-month data (62% male; age 69 ± 14 years; weight 82 ± 20 kg; 65% sinus nodal dysfunction, 30% atrioventricular block). ALPs were implanted predominantly in the right atrial appendage anterior base and VLPs primarily at the mid-to-apical right ventricular septum. From implant to 1 month, pacing capture thresholds (0.4-ms pulse width) improved in both ALPs (2.4 ± 1.5 V to 0.8 ± 0.8 V; P <.001) and VLPs (0.8 ± 0.6 V to 0.6 ± 0.4 V; P <.001). Sensed amplitudes improved in both ALPs (1.8 ± 1.3 mV to 3.4 ± 1.9 mV; P <.001) and VLPs (8.8 ± 4.0 mV to 11.7 ± 4.2 mV; P <.001). Impedances were stable in ALPs (334 ± 68 Ω to 329 ± 52 Ω; P = .17) and reduced in VLPs (789 ± 351 Ω to 646 ± 190 Ω; P <.001). Electrical measurements remained relatively stable from 1-6 months postimplant. No differences in electrical metrics were observed among ALP or VLP implant locations. CONCLUSION: This first in-human evaluation of the new dual-chamber leadless pacemaker system demonstrated reliable electrical performance throughout the initial 6-month evaluation period.


Subject(s)
Cardiac Pacing, Artificial , Equipment Design , Pacemaker, Artificial , Humans , Male , Female , Aged , Cardiac Pacing, Artificial/methods , Follow-Up Studies , Treatment Outcome , Heart Ventricles/physiopathology , Atrioventricular Block/therapy , Atrioventricular Block/physiopathology , Time Factors , Sick Sinus Syndrome/therapy , Sick Sinus Syndrome/physiopathology
13.
J Thorac Dis ; 16(2): 1702-1714, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38505041

ABSTRACT

Background and Objective: Treatment for atrial fibrillation (AF) has evolved significantly, with pulmonary vein isolation (PVI) becoming an established treatment. However, the outcomes following catheter ablation for persistent AF remain unsatisfactory. Hybrid catheter-surgical ablation has emerged as a therapeutic approach for persistent AF, combining the strengths of both interventions. The purpose of this narrative review is to comprehensively examine the current state of knowledge regarding hybrid ablation for AF. Methods: A thorough PubMed search using the terms "hybrid ablation", "atrial fibrillation", "catheter ablation", and "guideline on cardiology" within the timeframe of 1980 to 2024 resulted in 138,969 articles. Consensus on the selected articles was reached through a series of structured meetings and discussions. Key Content and Findings: PVI has demonstrated higher sinus rhythm maintenance rates, especially for paroxysmal AF. However, the efficacy is not as high for persistent AF. Additional ablation strategies, such as linear ablation, complex fractionated atrial electrogram ablation, low voltage zone ablation as well as posterior wall isolation, lack consistent evidence of effectiveness. Hybrid ablation, involving collaboration between cardiac surgeons and electrophysiologists, presents a promising alternative for hard-to-treat AF. Recent studies report favorable outcomes of hybrid ablation, with atrial arrhythmia-free rates ranging from 53.5% to 76%, surpassing those of catheter ablation alone, which might result from better lesion durability or intervention for non-PV foci and left atrial appendage excision or closure during hybrid ablation. The rate of complications associated with hybrid ablation is higher than catheter ablation alone. Conclusions: While favorable outcomes of hybrid ablation for persistent AF have been reported, it is not recommended for all AF patients due to its invasiveness compared to catheter ablation. Additionally, some patients with persistent AF maintain sinus rhythm with catheter ablation alone. More clinical data are needed to determine which patients are suitable candidates for hybrid ablation.

16.
Pacing Clin Electrophysiol ; 47(1): 127-130, 2024 01.
Article in English | MEDLINE | ID: mdl-38055652

ABSTRACT

BACKGROUND: Using third-party resources to manage remote monitoring (RM) data from implantable cardiac electronic devices (CIEDs) can assist in device clinic workflows. However, each hospital-acquired data is not used for further analysis as big data. METHODS AND RESULTS: We developed a real-time and automatically centralized system of CIED information from multiple hospitals. If the extensive data-based analysis suggests individual problems, it can be returned to each hospital. To show its feasibility, we prospectively analyzed data from six hospitals. For example, unexpected abnormal battery levels were easily illustrated without recall information. CONCLUSIONS: The centralized RM system could be a new platform that promotes the utilization of device data as big data, and that information could be used for each patient's practice.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Remote Sensing Technology/methods , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Monitoring, Physiologic/methods
18.
J Arrhythm ; 39(5): 681-756, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37799799

ABSTRACT

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.

19.
Circ J ; 87(12): 1809-1816, 2023 11 24.
Article in English | MEDLINE | ID: mdl-37532552

ABSTRACT

BACKGROUND: The Micra leadless pacemaker has demonstrated favorable outcomes in global trials, but its real-world performance and safety in a Japan-specific population is unknown.Methods and Results: Micra Acute Performance (MAP) Japan enrolled 300 patients undergoing Micra VR leadless pacemaker implantation in 15 centers. The primary endpoint was the acute (30-day) major complication rate. The 30-day and 6-month major complication rates were compared to global Micra studies. All patients underwent successful implantation with an average follow-up of 7.23±2.83 months. Compared with previous Micra studies, Japanese patients were older, smaller, more frequently female, and had a higher pericardial effusion risk score. 11 acute major complications were reported in 10 patients for an acute complication rate of 3.33% (95% confidence interval: 1.61-6.04%), which was in line with global Micra trials. Pericardial effusion occurred in 4 patients (1.33%; 3 major, 1 minor). No procedure or device-related deaths occurred. Frailty significantly improved from baseline to follow-up as assessed by Japan Cardiovascular Health Study criteria. CONCLUSIONS: In a Japanese cohort, implantation of the Micra leadless pacemaker had a high success rate and low major complication rate. Despite the Japan cohort being older, smaller, and at higher risk, the safety and performance was in line with global Micra trials.


Subject(s)
Arrhythmias, Cardiac , Pacemaker, Artificial , Female , Humans , East Asian People , Equipment Design , Pacemaker, Artificial/adverse effects , Pericardial Effusion/etiology , Treatment Outcome , Male , Arrhythmias, Cardiac/therapy
20.
J Arrhythm ; 39(3): 454-463, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37324755

ABSTRACT

Background: The long-term relationship between fracture-prone implantable cardioverter-defibrillator (ICD) leads and poor prognosis remains unclear in Japanese patients. Methods: We conducted a retrospective review of the records of 445 patients who underwent implantation of advisory/Linox leads (Sprint Fidelis, 118; Riata, nine; Isoline, 10; Linox S/SD, 45) and non-advisory leads (Endotak Reliance, 33; Durata, 199; Sprint non-Fidelis, 31) between January 2005 and June 2012 at our hospital. The primary outcomes were all-cause mortality and ICD lead failure. The secondary outcomes were cardiovascular mortality, heart failure (HF) hospitalization, and the composite outcome of cardiovascular mortality and HF hospitalization. Results: During the follow-up period (median, 8.6 [4.1-12.0] years), there were 152 deaths: 61 (34%) in patients with advisory/Linox leads and 91 (35%) in those with non-advisory leads. There were 32 ICD lead failures: 27 (15%) in patients with advisory/Linox leads and five (2%) in those with non-advisory leads. Multivariate analysis for ICD lead failure demonstrated that the advisory/Linox leads had a 6.65-fold significantly greater risk of ICD lead failure than non-advisory leads. Congenital heart disease (hazard ratio 2.51; 95% confidence interval 1.08-5.83; p = .03) could also independently predict ICD lead failure. Multivariate analysis for all-cause mortality demonstrated no significant association between advisory/Linox leads and all-cause mortality. Conclusions: Patients who have implanted fracture-prone ICD leads should be carefully followed up for ICD lead failure. However, these patients have a long-term survival rate comparable with that of patients with non-advisory ICD leads in Japanese patients.