Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 12(1): 8106, 2022 05 16.
Article in English | MEDLINE | ID: mdl-35577848

ABSTRACT

Melanin plays a significant role in the regulation of epidermal homeostasis and photoprotection of human skin. The assessment of its epidermal distribution and overall content is of great interest due to its involvement in a wide range of physiological and pathological skin processes. Among several spectroscopic and optical imaging methods that have been reported for non-invasive quantification of melanin in human skin, the approach based on the detection of two-photon excited fluorescence lifetime distinguishes itself by enabling selective detection of melanin with sub-cellular resolution, thus facilitating its quantification while also resolving its depth-profile. A key limitation of prior studies on the melanin assessment based on this approach is their inability to account for the skin heterogeneity due to the reduced field of view of the images, which results in high dispersion of the measurement values. Pigmentation in both normal and pathological human skin is highly heterogeneous and its macroscopic quantification is critical for reliable measurements of the epidermal melanin distribution and for capturing melanin-related sensitive dynamic changes as a response to treatment. In this work, we employ a fast large-area multiphoton exoscope (FLAME), recently developed by our group for clinical skin imaging, that has the ability to evaluate the 3D distribution of epidermal melanin content in vivo macroscopically (millimeter scale) with microscopic resolution (sub-micron) and rapid acquisition rates (minutes). We demonstrate significant enhancement in the reliability of the melanin density and distribution measurements across Fitzpatrick skin types I to V by capturing the intra-subject pigmentation heterogeneity enabled by the large volumetric sampling. We also demonstrate the potential of this approach to provide consistent measurement results when imaging the same skin area at different times. These advances are critical for clinical and research applications related to monitoring pigment modulation as a response to therapies against pigmentary skin disorders, skin aging, as well as skin cancers.


Subject(s)
Melanins , Microscopy, Fluorescence, Multiphoton , Epidermis/diagnostic imaging , Humans , Melanins/chemistry , Microscopy, Fluorescence, Multiphoton/methods , Reproducibility of Results , Skin/diagnostic imaging
2.
J Chem Phys ; 152(3): 034706, 2020 Jan 21.
Article in English | MEDLINE | ID: mdl-31968975

ABSTRACT

For a nanostructure sitting on top of an AlGaN:Er3+ thin film, a new thermal imaging technique is presented where dual cameras collect bandpass filtered videos from the H and S bands of Er3+ emission. We combine this thermal imaging technique with our newly developed time-resolved temperature measurement technique which relies on luminescence thermometry using Er3+ emission. This technique collects time-resolved traces from the H and S bands of Er3+ emission. The H and S signal traces are then used to reconstruct the time-resolved temperature transient when a nanostructure is illuminated with a pulsed 532 nm light. Two different types of samples are interrogated with these techniques (drop-casted gold nanosphere cluster and lithographically prepared gold nanodot) on the AlGaN:Er3+ film. Steady-state and time-resolved temperature data are collected when the samples are immersed in air and water. The results of time-resolved temperature-jump measurements from a cluster of gold nanospheres show extremely slow heat transfer when the cluster is immersed in water and nearly 200-fold increase when immersed in air. The low thermal diffusivity for the cluster in water suggests poor thermal contact between the cluster and the thermal bath. The lithographically prepared nanodot has much better adhesion to the AlGaN film, resulting in much higher thermal diffusivity in both air and water. This proof-of-concept demonstration opens a new way to measure the dynamics of the local heat generation and dissipation at the nanoparticle-media interface.

3.
Beilstein J Nanotechnol ; 9: 2916-2924, 2018.
Article in English | MEDLINE | ID: mdl-30546988

ABSTRACT

Hexagonal upconverting nanoparticles (UCNPs) of NaYF4:Er3+,Yb3+ (ca. 300 nm) have been widely used to measure the temperature at the nanoscale using luminescence ratio thermometry. However, several factors limit their applications. For example, changes in the peak shape, mainly is the S-band emission, hinders their ability to be used as a universal temperature sensor. Herein, we introduce a universal calibration protocol for NaYF4:Er3+,Yb3+ upconverting nanoparticles that is robust to environmental changes and gives a precise temperature measurement. We used this new procedure to calculate the temperature profile inside a Taylor cone generated with an electrospray jet. Inside the Taylor cone the fluid velocity increases toward the tip of the cone. A constant acquisition length leads to a decrease in excitation and acquisition time. This decrease in excitation time causes a peak shape change that corrupts the temperature measurement if the entire peak shape is integrated in the calibration. Our universal calibration circumvents this problem and can be used for time-resolved applications. The temperature at the end of the Taylor cone increases due to the creation of a whispering gallery mode cavity with 980 nm excitation. We use time-resolved energy balance equations to support our optical temperature measurements inside the Taylor cone. We believe that the findings of this paper provide a foundation for time-resolved temperature measurements using NaYF4:Er3+,Yb3+ upconverting nanoparticles and can be used to understand temperature-dependent reactions such as protein unfolding inside microjet/microdroplets and microfluidic systems.

SELECTION OF CITATIONS
SEARCH DETAIL
...