1.
J Biophotonics ; 17(6): e202400004, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38531622

ABSTRACT

Photoacoustic molecular imaging technology has a wide range of applications in biomedical research. In practical scenarios, both the probes and blood generate signals, resulting in the saliency of the probes in the blood environment being diminished, impacting imaging quality. Although several methods have been proposed for saliency enhancement, they inevitably suffer from moderate generality and detection speed. The Grüneisen relaxation (GR) nonlinear effect offers an alternative for enhancing saliency and can improve generality and speed. In this article, the excitation and detection efficiencies are optimized to enhance the GR signal amplitude. Experimental studies show that the saliency of the probe is enhanced. Moreover, the issue of signal aliasing is studied to ensure the accuracy of enhancement results in the tissues. In a word, the feasibility of the GR-based imaging method in saliency enhancement is successfully demonstrated in the study, showing the superiorities of good generality and detection speed.


Subject(s)
Molecular Imaging , Nonlinear Dynamics , Photoacoustic Techniques , Photoacoustic Techniques/methods , Molecular Imaging/methods , Animals , Image Processing, Computer-Assisted/methods
2.
Photoacoustics ; 36: 100589, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38318428

ABSTRACT

The endometrium microvessel system, responsible for supplying oxygen and nutrients to the embryo, holds significant importance in evaluating endometrial receptivity (ER). Visualizing this system directly can significantly enhance ER evaluation. Currently, clinical methods like Narrow-band hysteroscopy and Color Doppler ultrasound are commonly used for uterine blood vessel examination, but they have limitations in depth or resolution. Endoscopic Photoacoustic Imaging (PAE) has proven effective in visualizing microvessels in the digestive tract, while its adaptation to uterine imaging faces challenges due to the uterus's unique physiological characteristics. This paper for the first time that uses high-resolution PAE in vivo to capture a comprehensive network of endometrial microvessels non-invasively. Followed by continuous observation and quantitative analysis in the endometrial injury model, we further corroborated that PAE detection of endometrial microvessels stands as a valuable indicator for evaluating ER. The PAE system showcases its promising potential for integration into reproductive health assessments.

3.
Biomed Opt Express ; 12(4): 1934-1946, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-33996208

ABSTRACT

Myocardial infarctions are most often caused by the so-called vulnerable plaques, usually featured as non-obstructive lesions with a lipid-rich necrotic core, thin-cap fibroatheroma, and large plaque size. The identification and quantification of these characteristics are the keys to evaluate plaque vulnerability. However, single modality intravascular methods, such as intravascular ultrasound, optical coherence tomography and photoacoustic, can hardly achieve all the comprehensive information to satisfy clinical needs. In this paper, for the first time, we developed a novel multi-spectral intravascular tri-modality (MS-IVTM) imaging system, which can perform 360° continuous rotation and pull-backing with a 0.9-mm miniature catheter and achieve simultaneous acquisition of both morphological characteristics and pathological compositions. Intravascular tri-modality imaging demonstrates the ability of our MS-IVTM system to provide macroscopic and microscopic structural information of the vessel wall, with identity and quantification of lipids with multi-wavelength excitation. This study offers clinicians and researchers a novel imaging tool to facilitate the accurate diagnosis of vulnerable atherosclerotic plaques. It also has the potential of clinical translations to help better identify and evaluate high-risk plaques during coronary interventions.

4.
Biomed Opt Express ; 11(11): 6721-6731, 2020 Nov 01.
Article in English | MEDLINE | ID: mdl-33282520

ABSTRACT

Intravascular photoacoustic (IVPA) imaging technology enables the visualization of pathological characteristics (such as inflammation activities, lipid deposition) of the artery wall. Blood flushing is a necessary step in improving the imaging quality in in vivo IVPA imaging. But the limited imaging speed of the systems stretches their flushing time, which is an important obstacle of their clinical translations. In this paper, we report an improvement in IVPA/IVUS imaging speed to 100 frames per second. The high-speed imaging is demonstrated in rabbit in vivo, visualizing the nanoparticles accumulated on abdominal aorta wall at the wavelength of 1064 nm, in real time display. Blood flushing in vivo improves the IVPA signal-noise-ratio by around 3.5 dB. This study offers a stable, efficient and easy-to-use tool for instantaneous disease visualization and disease diagnosis in research and forwards IVPA/IVUS imaging technology towards clinical translations.

5.
Theranostics ; 10(10): 4694-4704, 2020.
Article in English | MEDLINE | ID: mdl-32292523

ABSTRACT

Objectives: The objective of this study was to demonstrate the feasibility of using noninvasive photoacoustic imaging technology along with novel semiconducting polymer nanoparticles for in vivo identifying inflammatory components in carotid atherosclerosis and assessing the severity of inflammation using mouse models. Methods and Results: Healthy carotid arteries and atherosclerotic carotid arteries were imaged in vivo by the noninvasive photoacoustic imaging system. Molecular probes PBD-CD36 were used to label the inflammatory cells to show the inflammation information by photoacoustic imaging. In in vivo imaging experiments, we observed the maximum photoacoustic signal enhancement of 4.3, 5.2, 8 and 16.3 times between 24 h post probe injection and that before probe injection in four carotid arteries belonging to three atherosclerotic mice models. In the corresponding carotid arteries stained with CD36, the ratio of 0.043, 0.061, 0.082 and 0.113 was found between CD36 positive (CD36(+)) expression area and intima-media area (P < 0.05). For the CD36(+) expression less than 0.008 in eight arteries, no photoacoustic signal enhancement was found due to the limited system sensitivity. The photoacoustic signal reflects CD36(+) expression in plaques, which shows the feasibility of using photoacoustic imaging for in vivo assessment of carotid atherosclerosis. Conclusion: This research demonstrates a semiconducting polymer nanoparticle along with photoacoustic technology for noninvasive imaging and assessment of inflammation of carotid atherosclerotic plaques in vivo.


Subject(s)
Carotid Artery Diseases/diagnostic imaging , Diagnostic Imaging/instrumentation , Inflammation/diagnostic imaging , Photoacoustic Techniques/methods , Animals , CD36 Antigens/metabolism , Carotid Artery Diseases/pathology , Case-Control Studies , Feasibility Studies , Inflammation/metabolism , Male , Mice , Mice, Knockout, ApoE , Molecular Probes/metabolism , Molecular Probes/ultrastructure , Polymers , Quantum Dots
6.
Ultrasonics ; 75: 28-35, 2017 03.
Article in English | MEDLINE | ID: mdl-27898302

ABSTRACT

In this paper, a novel sandwich-type traveling wave piezoelectric tracked mobile system was proposed, designed, fabricated and experimentally investigated. The proposed system exhibits the advantages of simple structure, high mechanical integration, lack of electromagnetic interference, and lack of lubrication requirement, and hence shows potential application to robotic rovers for planetary exploration. The tracked mobile system is comprised of a sandwich actuating mechanism and a metal track. The actuating mechanism includes a sandwich piezoelectric transducer and two annular parts symmetrically placed at either end of the transducer, while the metal track is tensioned along the outer surfaces of the annular parts. Traveling waves with the same rotational direction are generated in the two annular parts, producing the microscopic elliptical motions of the surface particles on the annular parts. In this situation, if the pre-load is applied properly, the metal track can be driven by friction force to achieve bidirectional movement. At first, the finite element method was adopted to conduct the modal analysis and harmonic response analysis of the actuating mechanism, and the vibration characteristics were measured to confirm the operating principle. Then the optimal driving frequency of the system prototype, namely 35.1kHz, was measured by frequency sensitivity experiments. At last, the mechanical motion characteristics of the prototype were investigated experimentally. The results show that the average motion speeds of the prototype in dual directions were as 72mm/s and 61.5mm/s under the excitation voltage of 500VRMS, respectively. The optimal loading weights of the prototype in bi-directions were 0.32kg and 0.24kg with a maximum speed of 59.5mm/s and 61.67mm/s at the driving voltage of 300VRMS, respectively.