Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anesth Analg ; 109(3): 825-31, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19690253

ABSTRACT

BACKGROUND: Although most tracheal intubations with direct laryngoscopy are not performed with a styletted endotracheal tube, it is recommended that a stylet can be used with indirect videolaryngoscopy. Recently, there were several reports of complications associated with styletted endotracheal tubes and videolaryngoscopy. In this study, we compared three videolaryngoscopes (VLSs) in patients undergoing tracheal intubation for elective surgery: the GlideScope Ranger (GlideScope, Bothell, WA), the V-MAC Storz Berci DCI (Karl Storz, Tuttlingen, Germany), and the McGrath (McGrath series 5, Aircraft medical, Edinburgh, UK) and tested whether it is feasible to intubate the trachea of patients with indirect videolaryngoscopy without using a stylet. METHODS: Four hundred fifty consecutive adults (ASA PS I-II) undergoing tracheal intubation for elective surgery were randomly allocated for airway management with one of the three devices. Anesthesia induction for tracheal intubation consisted of fentanyl-propofol-rocuronium. An independent anesthesiologist used the Cormack-Lehane grading system to score an initial direct laryngoscopic view using a classic metal Macintosh blade. After subsequent positive-pressure ventilation using a face mask and an oxygen-sevoflurane mixture for 1 min, the trachea was intubated using one of the three VLSs. During intubation, the following data were collected: intubation time, number of intubation attempts, use of extra tools to facilitate intubation, and overall satisfaction score of the intubation conditions. RESULTS: The trachea of every patient was intubated using the VLSs, and none of the patients required conversion to the classic Macintosh laryngoscope. All three VLSs offered equal or better view of the glottis as assessed by the mean Cormack-Lehane grade, compared with the traditional Macintosh laryngoscopy, including a larger viewing angle of the glottic entrance. The average intubation time was 34 +/- 20 s for the GlideScope, 18 +/- 12 s for the V-MAC Storz, and 38 +/- 23 s for the McGrath VLS. Intubation with the Storz was faster (P < 0.05) than the other two VLS tested and necessitated fewer additional tools (P < 0.01), resulting in a higher first-pass successful intubation rate. A stylet had to be used in 7% of the patients in the Storz group versus about 50% of the patients when the other two VLS were used. CONCLUSIONS: The trachea of a large proportion of patients with normal airways can be intubated successfully with certain VLS blades without using a stylet, although the three studied VLSs clearly differ in outcome. The Storz VLS displaces soft tissues in the fashion of a classic Macintosh scope, affording room for tracheal tube insertion and limiting the need for stylet use compared with the other two scopes. Although VLSs offer several advantages, including better visualization of the glottic entrance and intubation conditions, a good laryngeal view does not guarantee easy or successful tracheal tube insertion. We recommend that the geometry of VLSs, including blade design, should be studied in more detail.


Subject(s)
Intubation, Intratracheal/instrumentation , Laryngoscopes , Laryngoscopy/methods , Adult , Androstanols/pharmacology , Computers , Female , Fentanyl/pharmacology , Glottis/drug effects , Humans , Male , Middle Aged , Propofol/pharmacology , Rocuronium , Trachea/drug effects , Video Recording
2.
Surgery ; 133(3): 268-76, 2003 Mar.
Article in English | MEDLINE | ID: mdl-12660638

ABSTRACT

BACKGROUND: The strength of intestinal anastomoses is relatively low in the first days after operation, possibly as a result of localized degradation of the supporting matrix by enzymes from the matrix metalloproteinase (MMP) family. The aim of this study was to examine whether doxycycline, a drug known to inhibit MMP activity, could enhance anastomotic strength. METHODS: Male Wistar rats received anastomoses in both ileum and colon. From the day before operation onwards, animals were treated daily with doxycycline (orally or subcutaneously) in a dose of 10 mg/day or with saline only. Rats were killed 1, 3, or 5 days after operation, and anastomotic bursting pressure and breaking strength were measured. At day 3, anastomotic hydroxyproline levels were measured, MMP (gelatinase) activity was analyzed by gelatin zymography, and anastomotic histology was examined. RESULTS: Doxycycline enhanced wound strength, but only at day 3, when it was at its lowest. Subcutaneous administration of 10 mg/day increased median colonic and ileal breaking strength by 27% (P =.0019) and 104% (P =.0376), respectively. Colonic bursting pressure was increased by 93% (P =.0002). Wound histology was similar in experimental and control groups. CONCLUSIONS: Administration of doxycycline enhances anastomotic strength and should be investigated further as a means to preserve anastomotic integrity.


Subject(s)
Anti-Bacterial Agents/pharmacology , Colon/surgery , Doxycycline/pharmacology , Ileum/surgery , Surgical Wound Dehiscence/prevention & control , Wound Healing/drug effects , Anastomosis, Surgical , Animals , Colon/metabolism , Hydroxyproline/metabolism , Ileum/metabolism , Male , Matrix Metalloproteinases/metabolism , Rats , Rats, Wistar
SELECTION OF CITATIONS
SEARCH DETAIL