Ann Neurosci ; 25(4): 289-298, 2018 Dec.
Article in English | MEDLINE | ID: mdl-31000969

ABSTRACT

BACKGROUND: Closed-loop neurostimulation is a novel alternative therapy for medically intractable focal epilepsy for patients who are not candidates for surgical resection of a seizure focus. Electrodes for this system can be implanted either within the brain parenchyma or in the subdural space. The electrodes then serve the dual role of detecting seizures and delivering an electrical signal aimed at aborting seizure activity. The Responsive Neurostimulation (RNS®) system (Neuropace, Mountain View, CA, USA) is an FDA-approved implantable device designed for this purpose. OBJECTIVE: One of the challenges of the brain machine interface devices is the potential for implanted neurostimulator devices to induce progressive gliosis, apart from that associated with the minimal trauma at implantation. Gliosis has the potential to alter impedances over time, thereby affecting the clinical efficacy of these devices, and also poses a challenge to the prospects of in vivo repositioning of depth electrodes. We present a clinical case with 3-year follow-up and pathology. METHODS: Single-case, retrospective review within a randomized trial with specific minimum follow-up and impedance measurements. RESULTS: Impedance changes in the surface electrode over time were observed. Surgical pathological findings revealed significant gliosis in the leptomeninges of the cortices. CONCLUSION: We report, for the first time, long-term impedance recordings from a surface electrode associated with pathologic findings of gliosis at the Neuropace device-tissue interface in a patient who was enrolled in the multicenter RNS System Pivotal Clinical Investigation. Further study is required to elucidate the temporal relationship of pathological findings over time. Impedance changes were more complex than can be explained by a progressive or transient pathological mechanism. Further effort is required to elucidate the relationship between impedance change and seizure event capture.

3.
Ann Neurosci ; 23(2): 100-11, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27647960

ABSTRACT

BACKGROUND: The brain, made up of billions of neurons and synapses, is the marvelous core of human thought, action and memory. However, if neuronal activity manifests into abnormal electrical activity across the brain, neural behavior may exhibit synchronous neural firings known as seizures. If unprovoked seizures occur repeatedly, a patient may be diagnosed with epilepsy. PURPOSE: The scope of this project is to develop an ambulatory seizure monitoring system that can be used away from a hospital, making it possible for the user to stay at home, and primary care personnel to monitor a patient's seizure activity in order to provide deeper analysis of the patient's condition and apply personalized intervention techniques. METHODS: The ambulatory seizure monitoring device is a research device that has been developed with the objective of acquiring a portable, clean electroencephalography (EEG) signal and transmitting it wirelessly to a handheld device for processing and notification. RESULT: This device is comprised of 4 phases: acquisition, transmission, processing and notification. During the acquisition stage, the EEG signal is detected using EEG electrodes; these signals are filtered and amplified before being transmitted in the second stage. The processing stage encompasses the signal processing and seizure prediction. A notification is sent to the patient and designated contacts, given an impending seizure. Each of these phases is comprised of various design components, hardware and software. The experimental findings illustrate that there may be a triggering mechanism through the phase lock value method that enables seizure prediction. CONCLUSION: The device addresses the need for long-term monitoring of the patient's seizure condition in order to provide the clinician a better understanding of the seizure's duration and frequency and ultimately provide the best remedy for the patient.

4.
Neurocase ; 22(4): 362-8, 2016 08.
Article in English | MEDLINE | ID: mdl-27362339

ABSTRACT

Seizure localization includes neuroimaging like electroencephalogram, and magnetic resonance imaging (MRI) with limited ability to characterize the epileptogenic network. Temporal clustering analysis (TCA) characterizes epileptogenic network congruent with interictal epileptiform discharges by clustering together voxels with transient signals. We generated epileptogenic areas for 12 of 13 epilepsy patients with TCA, congruent with different areas of seizure onset. Resting functional MRI (fMRI) scans are noninvasive, and can be acquired quickly, in patients with different levels of severity and function. Analyzing resting fMRI data using TCA is quick and can complement clinical methods to characterize the epileptogenic network.


Subject(s)
Epilepsy/diagnostic imaging , Epilepsy/physiopathology , Functional Neuroimaging/methods , Hippocampus , Temporal Lobe , Adult , Electroencephalography , Hippocampus/diagnostic imaging , Hippocampus/pathology , Hippocampus/physiopathology , Humans , Magnetic Resonance Imaging , Temporal Lobe/diagnostic imaging , Temporal Lobe/pathology , Temporal Lobe/physiopathology
5.
Ann Neurosci ; 22(3): 181-8, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26130928

ABSTRACT

Deep brain stimulation (DBS) has been employed to treat a variety of disorders such as Parkinson disease, dystonia, and essential tremor. Newer indications such as epilepsy and obsessive-compulsive disorder have been added to the armamentarium. In this review, we present an initial summary of current methods in the management of obesity and then explore efforts in neuromodulation and DBS as a novel modality in the treatment of obesity disorders.

6.
Stereotact Funct Neurosurg ; 93(6): 419-26, 2015.
Article in English | MEDLINE | ID: mdl-26784455

ABSTRACT

BACKGROUND: Deep brain stimulation (DBS) for Parkinson's disease (PD) has traditionally been performed in awake patients. Some patients are unable to tolerate awake surgery or extensive time off their medication to allow for neurophysiological testing during traditional DBS implantation, which has previously limited surgical options for these patients. Recently, asleep image-guided lead placement using intraoperative MRI or CT for verification has been proposed as an alternative for patients unable or unwilling to undergo awake DBS surgery. METHODS: We conducted a retrospective chart review comparing PD patients who underwent asleep MRI-guided subthalamic nucleus (STN) DBS lead placement (n = 14) and awake neurophysiologically guided STN DBS lead placement (n = 23) at our institution. Both groups' levodopa equivalent daily doses (LEDDs) and complications at approximately 6 months of follow-up were compared, along with operative times. RESULTS: Both groups showed statistically similar reductions in LEDD at 6 months of therapy (38.27% for awake, 49.27% for asleep; p = 0.4447), and similar complications. Operative times were initially longer for MRI-guided DBS but improved with surgical experience. CONCLUSION: Asleep MRI-guided DBS is a viable option for PD patients unable or unwilling to undergo awake placement, with similar results in terms of LEDD reduction and complications.


Subject(s)
Deep Brain Stimulation/methods , Parkinson Disease/therapy , Subthalamic Nucleus/surgery , Adult , Aged , Female , Humans , Levodopa/therapeutic use , Magnetic Resonance Imaging/methods , Male , Middle Aged , Parkinson Disease/drug therapy , Parkinson Disease/surgery , Retrospective Studies , Treatment Outcome
7.
Clin Neurol Neurosurg ; 127: 79-85, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25459248

ABSTRACT

OBJECT: We report results of the initial experience with magnetic resonance image (MRI)-guided implantation of subthalamic nucleus (STN) deep brain stimulating (DBS) electrodes at the University of Wisconsin after having employed frame-based stereotaxy with previously available MR imaging techniques and microelectrode recording for STN DBS surgeries. METHODS: Ten patients underwent MRI-guided DBS implantation of 20 electrodes between April 2011 and March 2013. The procedure was performed in a purpose-built intraoperative MRI suite configured specifically to allow MRI-guided DBS, using a wide-bore (70 cm) MRI system. Trajectory guidance was accomplished with commercially available system consisting of an MR-visible skull-mounted aiming device and a software guidance system processing intraoperatively acquired iterative MRI scans. RESULTS: A total of 10 patients (5 male, 5 female)-representative of the Parkinson Disease (PD) population-were operated on with standard technique and underwent 20 electrode placements under MRI-guided bilateral STN-targeted DBS placement. All patients completed the procedure with electrodes successfully placed in the STN. Procedure time improved with experience. CONCLUSION: Our initial experience confirms the safety of MRI-guided DBS, setting the stage for future investigations combining physiology and MRI guidance. Further follow-up is required to compare the efficacy of the MRI-guided surgery cohort to that of traditional frame-based stereotaxy.


Subject(s)
Deep Brain Stimulation/methods , Magnetic Resonance Imaging/methods , Neurosurgical Procedures/methods , Surgery, Computer-Assisted/methods , Adult , Aged , Anesthesia , Deep Brain Stimulation/adverse effects , Electrodes, Implanted , Female , Humans , Male , Medical Errors , Microelectrodes , Middle Aged , Neurosurgical Procedures/adverse effects , Parkinson Disease/surgery , Stereotaxic Techniques , Subthalamic Nucleus , Surgery, Computer-Assisted/adverse effects
8.
J Vis Exp ; (87)2014 May 14.
Article in English | MEDLINE | ID: mdl-24894268

ABSTRACT

Convection-enhanced delivery (CED) has been proposed as a treatment option for a wide range of neurological diseases. Neuroinfusion catheter CED allows for positive pressure bulk flow to deliver greater quantities of therapeutics to an intracranial target than traditional drug delivery methods. The clinical utility of real time MRI guided CED (rCED) lies in the ability to accurately target, monitor therapy, and identify complications. With training, rCED is efficient and complications may be minimized. The agarose gel model of the brain provides an accessible tool for CED testing, research, and training. Simulated brain rCED allows practice of the mock surgery while also providing visual feedback of the infusion. Analysis of infusion allows for calculation of the distribution fraction (Vd/Vi) allowing the trainee to verify the similarity of the model as compared to human brain tissue. This article describes our agarose gel brain phantom and outlines important metrics during a CED infusion and analysis protocols while addressing common pitfalls faced during CED infusion for the treatment of neurological disease.


Subject(s)
Brain/anatomy & histology , Drug Delivery Systems/methods , Models, Anatomic , Neuroimaging/methods , Sepharose/chemistry , Computer Systems , Convection , Education, Medical/methods , Humans , Magnetic Resonance Imaging/methods
9.
Stereotact Funct Neurosurg ; 91(3): 153-61, 2013.
Article in English | MEDLINE | ID: mdl-23445991

ABSTRACT

BACKGROUND: Delivery of multiple collinear payloads utilizing convection-enhanced delivery (CED) has historically been performed by retraction of a needle or catheter from the most distal delivery site. Few studies have addressed end-infusion morphology and associated payload reflux in stacked and collinear infusions, and studies comparing the advancement with the retraction mode are lacking. OBJECTIVE: To compare advancement versus retraction mode infusion results. METHODS: Infusion cloud pairs were created with the advancement and retraction technique in agarose gel using both open end-port SmartFlow (SF) and valve tip (VT) catheter infusion systems. Backflow, radius of infusion, and morphology were assessed. RESULTS: Infusions with the SF catheter, in contrast to the VT catheter, exhibited significantly more backflow in retraction mode at the shallow infusion site. Infusion morphology differed with the second infusion after retraction: the infusate at the proximal site first filling the channel left by the retraction and then being convected into gel in a pronouncedly non-spherical shape during the second infusion. CONCLUSIONS: Significant differences in cloud morphology were noted with respect to external catheter geometry with retraction versus penetration between infusions in an agarose gel model of the brain. Further study is warranted to determine optimal protocols for human clinical trials employing CED with multiple collinear payloads.


Subject(s)
Drug Delivery Systems/methods , Parkinson Disease/drug therapy , Brain , Catheters , Convection , Gels , Humans
10.
Brain Stimul ; 6(5): 718-26, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23538208

ABSTRACT

Long-term stability of the electrode-tissue interface may be required to maintain optimal neural recording with subdural and deep brain implants and to permit appropriate delivery of neuromodulation therapy. Although short-term changes in impedance at the electrode-tissue interface are known to occur, long-term changes in impedance have not previously been examined in detail in humans. To provide further information about short- and long-term impedance changes in chronically implanted electrodes, a dataset from 191 persons with medically intractable epilepsy participating in a trial of an investigational responsive neurostimulation device (the RNS(®) System, NeuroPace, Inc.) was reviewed. Monopolar impedance measurements were available for 391 depth and subdural leads containing a total of 1564 electrodes; measurements were available for median 802 days post-implant (range 28-1634). Although there were statistically significant short-term impedance changes, long-term impedance was stable after one year. Impedances for depth electrodes transiently increased during the third week after lead implantation and impedances for subdural electrodes increased over 12 weeks post-implant, then were stable over the subsequent long-term follow-up. Both depth and subdural electrode impedances demonstrated long-term stability, suggesting that the quality of long-term electrographic recordings (the data used to control responsive brain stimulation) can be maintained over time.


Subject(s)
Brain/physiology , Electric Impedance , Electric Stimulation Therapy/methods , Epilepsy/therapy , Implantable Neurostimulators , Double-Blind Method , Electric Stimulation Therapy/instrumentation , Electrodes , Humans
11.
Stereotact Funct Neurosurg ; 91(2): 69-78, 2013.
Article in English | MEDLINE | ID: mdl-23344643

ABSTRACT

BACKGROUND: New strategies aiming to treat Parkinson's disease, such as delivery of trophic factors via protein infusion or gene transfer, depend upon localized intracerebral infusion, mainly into the putamen nucleus. Convection-enhanced delivery (CED) has been proposed as a method to improve intracerebral distribution of therapies. Yet analysis of controversial results during the clinical translation of these strategies suggests that intracerebral misdistribution of infusate may have affected the outcomes by limiting the amount of treatment into the target region. OBJECTIVES: This study aimed to identify possible pathways of infusate loss and their relative impact in the success of targeted CED into the postcommissural ventral putamen nucleus. METHODS: Thirteen adult macaque monkeys received intraputaminal CED infusions of 100 µl of 2.0 mM gadoteridol and bromophenol blue (0.16 mg/ml) solution at a rate of 1.0 µl/min under intraoperative magnetic resonance imaging (MRI) guidance. Quantitative maps of infusate concentration were computed at 10-min intervals throughout the procedure in a 3-Tesla MRI scanner. The fraction of tracer lost from the putamen as well as the path of loss were evaluated and quantified for each infusion. RESULTS: All injections (total 22) were successfully placed in the ventral postcommissural putamen nucleus. Four major paths of infusate loss from the putamen were observed: overflow across putamen boundaries, perivascular flow along large blood vessels, backflow along the inserted catheter and catheter tract leakage into the vacated catheter tract upon catheter removal. Overflow loss was observed within the first 30 µl of infusion in all cases. Measurable tracer loss following the path of an artery out of the putamen was observed in 15 cases, and in 8 of these cases, the loss was greater than 10% of infusate. Backflow that exited the putamen was observed in 4 cases and led to large loss of infusate (80% in 1 case) into the corona radiata. Loss into the vacated catheter tract amounted only to a few microliters. CONCLUSIONS: Our analysis demonstrates that after controlling for targeting, catheter type, infusion rate and infusate, the main issues during surgical planning are the identification of appropriate infusate volume that matches the target area, as well as mapping the regional vasculature as it may become a pathway for infusate loss. Most importantly, these results underscore the significance of presurgical planning for catheter placement and infusion, and the value of imaging guidance to ensure targeting accuracy.


Subject(s)
Bromphenol Blue/administration & dosage , Convection , Drug Delivery Systems/methods , Heterocyclic Compounds/administration & dosage , Organometallic Compounds/administration & dosage , Putamen/physiology , Animals , Catheterization/instrumentation , Catheterization/methods , Drug Delivery Systems/instrumentation , Female , Gadolinium/administration & dosage , Infusion Pumps , Infusions, Intraventricular , Macaca fascicularis , Macaca mulatta
12.
Ann Biomed Eng ; 41(2): 293-304, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23010803

ABSTRACT

UNLABELLED: Deep brain stimulation (DBS) efficacy is related to optimal electrode placement. Several authors have quantified brain shift related to surgical targeting; yet, few reports document and discuss the effects of brain shift after insertion. OBJECTIVE: To quantify brain shift and electrode displacement after device insertion. Twelve patients were retrospectively reviewed, and one post-operative MRI and one time-delayed CT were obtained for each patient and their implanted electrodes modeled in 3D. Two competing methods were employed to measure the electrode tip location and deviation from the prototypical linear implant after the resolution of acute surgical changes, such as brain shift and pneumocephalus. In the interim between surgery and a pneumocephalus free postoperative scan, electrode deviation was documented in all patients and all electrodes. Significant shift of the electrode tip was identified in rostral, anterior, and medial directions (p < 0.05). Shift was greatest in the rostral direction, measuring an average of 1.41 mm. Brain shift and subsequent electrode displacement occurs in patients after DBS surgery with the reversal of intraoperative brain shift. Rostral displacement is on the order of the height of one DBS contact. Further investigation into the time course of intraoperative brain shift and its potential effects on procedures performed with rigid and non-rigid devices in supine and semi-sitting surgical positions is needed.


Subject(s)
Deep Brain Stimulation/instrumentation , Electrodes, Implanted , Monitoring, Intraoperative/instrumentation , Aged , Brain/diagnostic imaging , Brain/physiopathology , Deep Brain Stimulation/methods , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Monitoring, Intraoperative/methods , Movement Disorders/therapy , Tomography, X-Ray Computed
13.
Ann Neurosci ; 20(2): 52-8, 2013 Apr.
Article in English | MEDLINE | ID: mdl-25206013

ABSTRACT

BACKGROUND: Convection enhanced delivery (CED) is an emerging form of direct brain infusion therapy employed in human functional and restorative neurosurgery clinical trials delivering protein, viral vectors for gene therapy, and siRNA. PURPOSE: Pressure monitoring has become a vital tool in ensuring infusion safety and success. We report details of this benchmark first trial of the use of a leading syringe infusion pump system capable of low-flow infusions. METHODS: Low-flow infusion performance of the FDA approved Alaris® System syringe pump, commonly used at our institution, was assessed during in vitro and ex vivo CED infusions. In vitro infusion cloud morphology and line pressure were analyzed utilizing a neuroinfusion catheter and delivering volumes and flow rates proposed for a human gene therapy protocol for Parkinson's disease. RESULTS: Pressure monitoring results correlated with previously published in-line pressure monitoring results however the time to peak with catheter occlusion was extended due to the method of pressure monitoring with this device. CONCLUSION: MRI compatible infusion pumps used for brain delivery injectables, pressure monitoring is set to be a guiding instrument for the health care professional employing this emerging form of infusion-to-brain delivery. Further development of infusion pump technology is warranted to allow for infuse/withdraw mode, infusion pressure graphical and numerical display, and pressure monitoring without the need for an inflatable reservoir pressure device. MRI safe infusion systems will need to be available and nursing staff educated to prepare infusions within the high-field environment.

14.
Ann Neurosci ; 20(2): 59-64, 2013 Apr.
Article in English | MEDLINE | ID: mdl-25206014

ABSTRACT

BACKGROUND: Convection enhanced delivery (CED) is a technique using infusion convection currents to deliver therapeutic agents into targeted regions of the brain. Recently, CED is gaining significant acceptance for use in gene therapy of Parkinson's disease (PD) employing direct infusion into the brain. CED offers advantages in that it targets local areas of the brain, bypasses the blood-brain barrier (BBB), minimizes systemic toxicity of the therapeutics, and allows for delivery of larger molecules that diffusion driven methods cannot achieve. Investigating infusion characteristics such as backflow and morphology is important in developing standard and effective protocols in order to successfully deliver treatments into the brain. Optimizing clinical infusion protocols may reduce backflow, improve final infusion cloud morphology, and maximize infusate penetrance into targeted tissue. PURPOSE: The purpose of the current study was to compare metrics during ramped-rate and continuous-rate infusions using two different catheters in order to optimize current infusion protocols. Occasionally, the infusate refluxes proximally up the catheter tip, known as backflow, and minimizing this can potentially reduce undesirable effects in the clinical setting. Traditionally, infusions are performed at a constant rate throughout the entire duration, and backflow is minimized only by slow infusion rates, which increases the time required to deliver the desired amount of infusate. In this study, we investigate the effects of ramping and various infusion rates on backflow and infusion cloud morphology. The independent parameters in the study are: ramping, maximum infusion rate, time between rate changes, and increments of rate changes. METHODS: Backflow was measured using two methods: i) at the point of pressure stabilization within the catheter, and ii) maximum backflow as shown by video data. Infusion cloud morphology was evaluated based on the height-to-width ratio of each infusion cloud at the end of each experiment. Results were tabulated and statistically analyzed to identify any significant differences between protocols. RESULTS: The experimental results show that CED rampedrate infusion protocols result in smaller backflow distances and more spherical cloud morphologies compared to continuous-rate infusion protocols ending at the same maximum infusion rate. Our results also suggest internal-line pressure measurements can approximate the time-point at which backflow ceases. CONCLUSION: Our findings indicate that ramping CED infusion protocols can potentially minimize backflow and produce more spherical infusion clouds. However, further research is required to determine the strength of this correlation, especially in relation to maximum infusion rates.

15.
Ann Neurosci ; 20(3): 99-107, 2013 Jul.
Article in English | MEDLINE | ID: mdl-25206025

ABSTRACT

BACKGROUND: The electrical properties of agarose gel, namely impedance and capacitance, are relatively unexplored. Agarose gels are used as in vitro models in studies across numerous disciplines, including imaging, radiotherapy, infusion, and neurosurgery. PURPOSE: In this study, we seek to characterize the impedance response of low concentration agarose gels by relating the gel concentrations to Nyquist Plot phase in order to establish a baseline with which to modify the response of the gel to simulate that of in vivo brain tissue. This information is relevant to areas such as deep brain stimulation, and could have a significant impact on in vitro model design for such studies in the future. METHODS: Ten agarose gels spanning four different concentrations were subjected to impedance spectroscopy using a Model 3387 DBS electrode. Phase angles were calculated and Cartesian Nyquist plots generated from the data. RESULTS: Results suggest that an inverse relationship exists between agarose gel concentration and phase angle. In addition, the results indicate that agarose gel reasonably emulates a constant phase element, which portrays the electrode-electrolyte interface impedance of some equivalent circuit models of brain tissue. CONCLUSION: The data shows that agarose gel is a suitable substrate for a deep brain stimulation in vitro model, but requires modification. In the future, we plan to utilize this data to determine the modifications necessary in the current agarose gel model to make it scientifically applicable to studies of both deep brain stimulation and infusion due to their overlapping variables.

16.
Ann Neurosci ; 20(3): 108-14, 2013 Jul.
Article in English | MEDLINE | ID: mdl-25206026

ABSTRACT

BACKGROUND: Convection enhanced delivery (CED) is emerging as a promising infusion toolto facilitate delivery of therapeutic agents into the brain via mechanically controlled pumps. Infusion protocols and catheter design have an important impact on delivery. CED is a valid alternative for systemic administration of agents in clinical trials for cell and gene therapies. Where gel and ex vivo models are not sufficient in modeling the disease, in vivo models allow researchers to better understand the underlying mechanisms of neuron degeneration, which is helpful in finding novel approaches to control the process or reverse the progression. Determining the risks, benefits, and efficacy of new gene therapies introduced via CED will pave a way to enter human clinical trial. PURPOSE: The objective of this study is to compare volume distribution (Vd)/ volume infused (Vi) ratios and backflow measurements following CED infusions in ex vivo versus in vivo non-human primate brain tissue, based on infusion protocols developed in vitro. METHODS: In ex vivo infusions, the first brain received 2 infusions using a balloon catheter at rates of 1 µL/min and 2 µL/min for 30 minutes. The second and third brains received infusions using a valve-tip (VT) catheter at 1 µL/min for 30 minutes. The fourth brain received a total of 45 µL infused at a rate of 1 µL/min for 15 minutes followed by 2 µL/min for 15 minutes. Imaging was performed (SPGR FA34) every 3 minutes. In the in vivo group, 4 subjects received a total of 8 infusions of 50 µL. Subjects 1 and 2 received infusions at 1.0 µL/min using a VT catheter in the left hemisphere and a smart-flow (SF) catheter in the right hemisphere. Subjects 3 and 4 each received 1 infusion in the left and right hemisphere at 1.0 µL/min. RESULTS: MRI calculations of Vd/Vi did not significantly differ from those obtained on post-mortem pathology. The mean measured Vd/Vi of in vivo (5.23 + /-1.67) compared to ex vivo (2.17 + /-1.39) demonstrated a significantly larger Vd/Vi for in vivo by 2.4 times (p = 0.0017). CONCLUSION: We detected higher ratios in the in vivo subjects than in ex vivo. This difference could be explained by the extra cellular space volume fraction. Studies evaluating backflow and morphology use in vivo tissue as a medium are recommended. Further investigation is warranted to evaluate the role blood pressure and heart rate may play in human CED clinical trials.

17.
Ann Neurosci ; 20(3): 118-22, 2013 Jul.
Article in English | MEDLINE | ID: mdl-25206029

ABSTRACT

This purpose of this paper is to review the recent history of the use of agarose gels. Although originally confined to electrophoresis work, agarose gels have proven themselves useful to a number of disciplines in the modern world, which includes brain infusion studies for research involving the treatment of various neurological conditions, such as Parkinson's Disease. In reviewing the relevant research leading up to the modern day, this paper attempts to track agarose gels through their stages of accuracy verification, highlighting why they are useful to the neurosurgery discipline and characterizing the nature of their use. Agarose gels do have significant limitations, which are also discussed, but they have substantial potential as a modifiable medium or as a basis of comparison for even more accurate models in the future.

18.
J Neural Eng ; 9(2): 026009, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22331865

ABSTRACT

Convection-enhanced delivery (CED) is an advanced infusion technique used to deliver therapeutic agents into the brain. CED has shown promise in recent clinical trials. Independent verification of published parameters is warranted with benchmark testing of published parameters in applicable models such as gel phantoms, ex vivo tissue and in vivo non-human animal models to effectively inform planned and future clinical therapies. In the current study, specific performance characteristics of two CED infusion catheter systems, such as backflow, infusion cloud morphology, volume of distribution (mm(3)) versus the infused volume (mm(3)) (Vd/Vi) ratios, rate of infusion (µl min(-1)) and pressure (mmHg), were examined to ensure published performance standards for the ERG valve-tip (VT) catheter. We tested the hypothesis that the ERG VT catheter with an infusion protocol of a steady 1 µl min(-1) functionality is comparable to the newly FDA approved MRI Interventions Smart Flow (SF) catheter with the UCSF infusion protocol in an agarose gel model. In the gel phantom models, no significant difference was found in performance parameters between the VT and SF catheter. We report, for the first time, such benchmark characteristics in CED between these two otherwise similar single-end port VT with stylet and end-port non-stylet infusion systems. Results of the current study in agarose gel models suggest that the performance of the VT catheter is comparable to the SF catheter and warrants further investigation as a tool in the armamentarium of CED techniques for eventual clinical use and application.


Subject(s)
Brain/physiology , Catheters , Drug Delivery Systems , Genetic Therapy/methods , Magnetic Resonance Imaging/methods , Models, Neurological , Parkinson Disease/therapy , Algorithms , Benchmarking , Biocompatible Materials , Coloring Agents , Computers , Data Interpretation, Statistical , Gels , Humans , Infusion Pumps, Implantable , Parkinson Disease/genetics , Sepharose
19.
Ann Neurosci ; 19(3): 133-46, 2012 Jul.
Article in English | MEDLINE | ID: mdl-25205986

ABSTRACT

The existing treatment of Parkinson's disease (PD) is directed towards substituting dopamine loss with either dopamine replacement therapy or pharmacological therapies aimed at increasing dopamine at the synapse level. Emerging viable alternatives include the use of cell-based and gene-based therapeutics. In this review, we discuss efforts in developing in vitro and in vivo models and their translation to human clinical trials for gene-based therapy of this distressing and prevalent neurodegenerative disorder. Given the mismatch between expectations from preclinical data and results of human pivotal trials, drug delivery has been identified as the key emerging area for translational research due to limitation of limited efficacy. The chief highlights of the current topic include use of improved delivery methods of gene-based therapeutic agents. Convection-enhanced delivery (CED), an advanced infusion technique with demonstrated utility in ex vivo and in vivo animal models has recently been adopted for PD gene-based therapy trials. Several preclinical studies suggest that magnetic resonance imaging (MRI)-guided navigation for accurately targeting and real time monitoring viral vector delivery (rCED) in future clinical trials involving detection of gene expression and restoration of dopaminergic function loss using pro-drug approach will greatly enhance these PD treatments.

20.
Clin EEG Neurosci ; 42(4): 259-65, 2011 Oct.
Article in English | MEDLINE | ID: mdl-22208124

ABSTRACT

Over the past decade, electrocorticography (ECoG) has been used for a wide set of clinical and experimental applications. Recently, there have been efforts in the clinic to adapt traditional ECoG arrays to include smaller recording contacts and spacing. These devices, which may be collectively called "micro-ECoG" arrays, are loosely defined as intercranial devices that record brain electrical activity on the sub-millimeter scale. An extensible 3D-platform of thin film flexible micro-scale ECoG arrays appropriate for Brain-Computer Interface (BCI) application, as well as monitoring epileptic activity, is presented. The designs utilize flexible film electrodes to keep the array in place without applying significant pressure to the brain and to enable radial subcranial deployment of multiple electrodes from a single craniotomy. Deployment techniques were tested in non-human primates, and stimulus-evoked activity and spontaneous epileptic activity were recorded. Further tests in BCI and epilepsy applications will make the electrode platform ready for initial human testing.


Subject(s)
Electroencephalography/methods , Epilepsy/physiopathology , Motor Cortex/physiology , User-Computer Interface , Animals , Craniotomy , Deep Brain Stimulation/instrumentation , Deep Brain Stimulation/methods , Electrodes, Implanted , Electroencephalography/instrumentation , Equipment Design , Evoked Potentials , Macaca fascicularis , Microelectrodes , Motor Cortex/surgery