Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Prosthodont ; 37(7): 79-88, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38498860

ABSTRACT

PURPOSE: To compare the accuracy of 12 different dental restorations fabricated with milling or 3D-printed molds and robotically controlled casting. MATERIALS AND METHODS: Twelve dental restorations (11 inlays and onlays and 1 crown) were made per restoration type, one per each of the 12 different teeth models (total of 24 restorations). On each tooth preparation, two restorations were manufactured using different CAD/ CAM techniques: (1) milling and (2) robotically controlled casting and 3D-printed molds. In addition, twolayer restorations were manufactured with 3D-printed molds. The marginal and internal gaps were evaluated at 120 points per restoration based on micro-CT 3D imaging. Internal gaps were evaluated using a replica technique with silicone. RESULTS: Median values (interquartile ranges) for marginal gaps, middle internal gaps, and central internal gaps were significantly lower for 3D-printed mold restorations (44.3 [65.4] µm, 95.4 [96.2] µm, and 104.6 [78.1] µm) compared to milled restorations (58.4 [93] µm, 145.9 [85.8] µm, and 138.6 [65.7] µm). Internal gaps in the 3D-printed mold group were 6% to 51% smaller than in the milled group. CONCLUSIONS: The accuracy of restorations fabricated with 3D-printed molds may be preferable compared to milled restorations, except in the case of crown restoration. However, additional studies with a larger number of samples and different types of restorations are needed to confirm the results.


Subject(s)
Computer-Aided Design , Dental Marginal Adaptation , Pilot Projects , Inlays , Crowns , Printing, Three-Dimensional , Dental Prosthesis Design/methods
2.
Otol Neurotol ; 44(4): 339-345, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36843083

ABSTRACT

HYPOTHESIS: Micro-computed tomography (micro-CT) and cone-beam computed tomography (CBCT), in conjunction with the image fusion technique, may provide similar results for trauma assessment after cochlear implantation, with respect to the trauma evaluation in preclinical cochlear implant (CI) studies, as the histology. BACKGROUND: Before clinical use, novel cochlear implant (CI) designs are tested in temporal bone (TB) studies for usability and risk evaluation. The criterion standard for evaluating intracochlear insertion trauma and electrode location has historically been with histological samples. Progress of modern imaging technology has created alternatives to classic histology. This study compares the micro-CT and CBCT fusion images between histological samples in a preclinical CI study. METHODS: Fourteen freshly frozen TBs were inserted with a lateral wall research CI electrode. All TBs were scanned with CBCT preoperatively and postoperatively. After insertion, the TBs were prepared for micro-CT and histology. Twelve TBs underwent first a micro-CT and then the histological process. The CBCTs were used for image fusion, and all three different methods were used for intracochlear trauma evaluation. The results were compared between methods. RESULTS: There were 4 of 14 translocations detected with the fusion image method and 3 of 12 with the micro-CT and histology. When compared, the trauma grades converged and were not statistically significant. CONCLUSION: The trauma grading based on micro-CT is comparable to the histology. The image fusion technique based on CBCT is less accurate because it relies on an empirical assumption of the basal membrane localization, but it is clinically applicable.


Subject(s)
Cochlear Implantation , Cochlear Implants , Humans , Cochlear Implantation/methods , X-Ray Microtomography , Cochlear Implants/adverse effects , Cone-Beam Computed Tomography/methods , Temporal Bone/diagnostic imaging , Temporal Bone/surgery , Cochlea/diagnostic imaging , Cochlea/surgery
3.
Int J Pharm ; 617: 121581, 2022 Apr 05.
Article in English | MEDLINE | ID: mdl-35176331

ABSTRACT

Biomaterial aerogel fabrication by freeze-drying must be further improved to reduce the costs of lengthy freeze-drying cycles and to avoid the formation of spongy cryogels and collapse of the aerogel structures. Residual water content is a critical quality attribute of the freeze-dried product, which can be monitored in-line with near-infrared (NIR) spectroscopy. Predictive models of NIR have not been previously applied for biomaterials and the models were mostly focused on the prediction of only one formulation at a time. We recorded NIR spectra of different nanofibrillated cellulose (NFC) hydrogel formulations during the secondary drying and set up a partial least square regression model to predict their residual water contents. The model can be generalized to measure residual water of formulations with different NFC concentrations and the excipients, and the NFC fiber concentrations and excipients can be separated with the principal component analysis. Our results provide valuable information about the freeze-drying of biomaterials and aerogel fabrication, and how NIR spectroscopy can be utilized in the optimization of residual water content.


Subject(s)
Cellulose , Spectroscopy, Near-Infrared , Freeze Drying/methods , Least-Squares Analysis , Principal Component Analysis , Spectroscopy, Near-Infrared/methods
4.
Ultrastruct Pathol ; 45(4-5): 276-285, 2021.
Article in English | MEDLINE | ID: mdl-34423726

ABSTRACT

Radiation therapy may compromise the quality of bone around dental implants, and its ability to regenerate, remodel, and revascularize. This study aimed to describe the irradiation effect on the bone microstructure of the mandible using dental implants in a canine model. Five beagle dogs were exposed to 40 Gy fractionated radiation. In total, 20 dental implants were inserted, two in the irradiated and two in the non-irradiated side. The mandible bone blocks were subjected to 3D micro-computed tomography (µCT) imaging, later evaluated histomorphometrically by light microscopy and scanning electron microscopy. Alterations in irradiated bone were observed under µCT imaging showing an increased anisotropy, porosity, and pore volume. Bone surface-to-bone volume decreased. The bone to implant contact index was significantly reduced in the irradiated bone (75.6% ± 5.8%) as compared to the non-irradiated bone (85.1% ± 6.8%). In the irradiated mandible, osteocytes with their filopodial processes, the bone beneath the periosteum, and subperiosteal veins showed structural differences but were not significant, whereas the diameter of Haversian canals were smaller statistical significant as compared to the control side. The study highlights that radiation dosage of fractioned 40 Gy causes alterations in the alveolar bone microstructure with compatible osseointegration and clinically stable dental implants.


Subject(s)
Dental Implants , Animals , Dogs , Mandible/diagnostic imaging , Osseointegration , Osteocytes , X-Ray Microtomography
5.
Connect Tissue Res ; 60(2): 95-106, 2019 03.
Article in English | MEDLINE | ID: mdl-29560747

ABSTRACT

AIM: The horse joint, due to its similarity with the human joint, is the ultimate model for translational articular cartilage repair studies. This study was designed to determine the critical size of cartilage defects in the equine carpus and serve as a benchmark for the evaluation of new cartilage treatment options. MATERIAL AND METHODS: Circular full-thickness cartilage defects with a diameter of 2, 4, and 8 mm were created in the left middle carpal joint and similar osteochondral (3.5 mm in depth) defects in the right middle carpal joint of 5 horses. Spontaneously formed repair tissue was examined macroscopically, with MR and µCT imaging, polarized light microscopy, standard histology, and immunohistochemistry at 12 months. RESULTS: Filling of 2 mm chondral defects was good (77.8 ± 8.5%), but proteoglycan depletion was evident in Safranin-O staining and gadolinium-enhanced MRI (T1Gd). Larger chondral defects showed poor filling (50.6 ± 2.7% in 4 mm and 31.9 ± 7.3% in 8 mm defects). Lesion filling in 2, 4, and 8 mm osteochondral defects was 82.3 ± 3.0%, 68.0 ± 4.6% and 70.8 ± 15.4%, respectively. Type II collagen staining was seen in 9/15 osteochondral defects but only in 1/15 chondral defects. Subchondral bone pathologies were evident in 14/15 osteochondral samples but only in 5/15 chondral samples. Although osteochondral lesions showed better neotissue quality than chondral lesions, the overall repair was deemed unsatisfactory because of the subchondral bone pathologies. CONCLUSION: We recommend classifying 4 mm as critical osteochondral lesion size and 2 mm as critical chondral lesion size for cartilage repair research in the equine carpal joint model.


Subject(s)
Carpal Joints/pathology , Cartilage, Articular/pathology , Horses/anatomy & histology , Animals , Carpal Joints/diagnostic imaging , Cartilage, Articular/diagnostic imaging , Magnetic Resonance Imaging , Microscopy, Polarization , Time Factors , Wound Healing , X-Ray Microtomography
6.
Cartilage ; 4(1): 42-51, 2013 Jan.
Article in English | MEDLINE | ID: mdl-26069649

ABSTRACT

OBJECTIVE: Differences in contrast agent diffusion reflect changes in composition and structure of articular cartilage. However, in clinical application the contrast agent concentration in the joint capsule varies, which may affect the reliability of contrast enhanced cartilage tomography (CECT). In the present study, effects of concentration of x-ray contrast agents on their diffusion and equilibrium distribution in cartilage were investigated. DESIGN: Full-thickness cartilage discs (d = 4.0 mm, n = 120) were detached from bovine patellae (n = 24). The diffusion of various concentrations of ioxaglate (5, 10, 21, 50 mM) and iodide (30, 60, 126, 300 mM) was allowed only through the articular surface. Samples were imaged with a clinical peripheral quantitative computed tomography scanner before immersion in contrast agent, and after 1, 5, 9, 16, 25, and 29 hours in the bath. RESULTS: Diffusion and partition coefficients were similar between different contrast agent concentrations. The diffusion coefficient of iodide (473 ± 133 µm(2)/s) was greater (P ≤ 0.001) than that of ioxaglate (92 ± 46 µm(2)/s). In full-thickness cartilage, the partition coefficient (at 29 h) of iodide (71 ± 5%) was greater (P ≤ 0.02 with most concentrations) than that of ioxaglate (62 ± 6%). CONCLUSIONS: Significant differences in partition and diffusion coefficient of two similarly charged (-1) contrast agents were detected, which shows the effect of steric interactions. However, the increase in solute concentration did not increase its partition coefficient. In clinical application, it is important that contrast agent concentration does not affect the interpretation of CECT imaging.

7.
Phys Med Biol ; 54(22): 6823-36, 2009 Nov 21.
Article in English | MEDLINE | ID: mdl-19864699

ABSTRACT

Charged contrast agents have been used both in vitro and in vivo for estimation of the fixed charge density (FCD) in articular cartilage. In the present study, the effects of molecular size and charge on the diffusion and equilibrium distribution of several magnetic resonance imaging (MRI) and computed tomography (CT) contrast agents were investigated. Full thickness cartilage disks (Ø = 4.0 mm, n = 64) were prepared from fresh bovine patellae. Contrast agent (gadopentetate: Magnevist((R)), gadodiamide: Omniscan, ioxaglate: Hexabrix or sodium iodide: NaI) diffusion was allowed either through the articular surface or through the deep cartilage. CT imaging of the samples was conducted before contrast agent administration and after 1, 5, 9, 16, 25 and 29 h (and with three samples after 2, 3, 4 and 5 days) diffusion using a clinical peripheral quantitative computed tomography (pQCT) instrument. With all contrast agents, the diffusion through the deep cartilage was slower when compared to the diffusion through the articular surface. With ioxaglate, gadopentetate and gadodiamide it took over 29 h for diffusion to reach the near-equilibrium state. The slow diffusion of the contrast agents raise concerns regarding the validity of techniques for FCD estimation, as these contrast agents may not reach the equilibrium state that is assumed. However, since cartilage composition, i.e. deep versus superficial, had a significant effect on diffusion, imaging of the nonequilibrium diffusion process might enable more accurate assessment of cartilage integrity.


Subject(s)
Cartilage, Articular/chemistry , Contrast Media/chemistry , Gadolinium DTPA/chemistry , Ioxaglic Acid/chemistry , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Animals , Cattle , Diffusion , In Vitro Techniques , Tissue Distribution
8.
Exp Gerontol ; 44(11): 708-17, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19706321

ABSTRACT

The effects of lifelong physical exercise on the composition, structure and mechanical properties of bone are not well understood. Earlier, we found that voluntary physical exercise improved various properties of bone in maturing male mice up to 6 months of age. In this study, we extended the previous study to 18 months. Half of the mice (total N=144) had access to running wheels while half were kept sedentary. The collagen network was assessed biochemically and by tensile testing of decalcified bone. The mineralized femur was analyzed with pQCT and three-point-bending of the diaphysis and neck-strength-test. The proximal tibia was analyzed with microCT. The bone collagen revealed inferior tensional properties with aging and the mineralized femur demonstrated decreased stiffness with age. In the running mice, tensile properties and the BMD were reduced at 18 months of age compared to the sedentary mice. In contrast, the stiffness of both the diaphysis and femoral neck was higher, and trabecular architecture and structure were improved in the running mice. In summary, the results suggest that lifelong exercise training of male mice results in more beneficial effects on intact mineralized bone in both the diaphysis and epiphysis than on bone collagenous matrix.


Subject(s)
Bone Density/physiology , Collagen/metabolism , Extracellular Matrix/metabolism , Femur Neck/physiology , Physical Conditioning, Animal , Animals , Bone Development/physiology , Femur Neck/anatomy & histology , Male , Mice , Mice, Inbred C57BL , Physical Conditioning, Animal/physiology , Running/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...