Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Saudi J Ophthalmol ; 37(4): 331-336, 2023.
Article in English | MEDLINE | ID: mdl-38155684

ABSTRACT

PURPOSE: To compare the visual outcome findings between a new monofocal intraocular lens (IOL) (Tecnis Eyhance) and extended depth of focus (EDOF) IOL (Appasamy Supraphob Infocus). METHODS: This prospective comparative interventional study evaluated 31 patients after implantation of Tecnis Eyhance (15 patients) and Supraphob EDOF IOL (16 patients). The uncorrected and corrected distance and intermediate and near visual acuity were measured at postoperative day 1, 1 week, 4 week, and 3 months. Contrast sensitivity, incidence of halos and glares, and patient satisfaction were assessed at 3 months postoperatively. RESULTS: The Tecnis Eyhance (n = 15) and Supraphob EDOF (n = 16) group were comparable with respect to all preoperative parameters including biometry, visual acuity, and cataract status. The average age distribution of participants was 56 ± 6 years. Postoperatively, both groups had similar distance and intermediate vision, but the near vision was significantly better in the EDOF group (P < 0.01) as compared to Tecnis Eyhance at 3 months. The contrast sensitivity and patient satisfaction were similar in both the groups. The incidence of halos and glares was present in the EDOF group, but it was statistically insignificant. CONCLUSION: The Tecnis Eyhance and Supraphob EDOF both were effective in improving distance and intermediate vision, but the near vision was significantly better in the EDOF group. Both the groups retained good contrast sensitivity and the majority of patients were satisfied.

2.
Water Sci Technol ; 61(2): 415-20, 2010.
Article in English | MEDLINE | ID: mdl-20107268

ABSTRACT

Aeration experiments, maintaining nappe flow conditions, were carried out on a rectangular stepped cascade of total height 3.0 m to determine the total number of steps, slope of the entire cascade and hydraulic loading rate at which maximum overall aeration efficiency occurs, keeping the surface area of individual steps constant. Based on dimensional analysis, the overall aeration efficiency at standard conditions (E(20)) was expressed as a function of square of total number of steps (N(2)) and dimensionless discharge (d(c)/h), where d(c) and h represent critical depth in a rectangular prismatic channel and individual step height respectively. An empirical equation with E(20) as the response and N(2) and d(c)/h as the independent parameters was developed based on the experimental results subject to 36

Subject(s)
Oxygen/chemistry , Waste Disposal, Fluid/methods , Water/chemistry , Models, Theoretical , Water Movements
SELECTION OF CITATIONS
SEARCH DETAIL