Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 260
Filter
1.
Curr Cardiol Rep ; 2024 May 28.
Article in English | MEDLINE | ID: mdl-38806976

ABSTRACT

PURPOSE OF REVIEW: Recent studies have demonstrated an association between obstructive sleep apnea (OSA) and abnormal myocardial blood flow (MBF), myocardial flow reserve (MFR), and coronary microvascular dysfunction (CMD). Here, we review the evidence and describe the potential underlying mechanisms linking OSA to abnormal MBF. Examining relevant studies, we assess the impact of OSA-specific therapy, such as continuous positive airway pressure (CPAP), on MBF. RECENT FINDINGS: Recent studies suggest an association between moderate to severe OSA and abnormal MBF/MFR. OSA promotes functional and structural abnormalities of the coronary microcirculation. OSA also promotes the uncoupling of MBF to cardiac work. In a handful of studies with small sample sizes, CPAP therapy improved MBF/MFR. Moderate to severe OSA is associated with abnormal MFR, suggesting an association with CMD. Evidence suggests that CPAP therapy improves MBF. Future studies must determine the clinical impact of improved MBF with CPAP.

2.
Med Image Anal ; 96: 103190, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38820677

ABSTRACT

Inter-frame motion in dynamic cardiac positron emission tomography (PET) using rubidium-82 (82Rb) myocardial perfusion imaging impacts myocardial blood flow (MBF) quantification and the diagnosis accuracy of coronary artery diseases. However, the high cross-frame distribution variation due to rapid tracer kinetics poses a considerable challenge for inter-frame motion correction, especially for early frames where intensity-based image registration techniques often fail. To address this issue, we propose a novel method called Temporally and Anatomically Informed Generative Adversarial Network (TAI-GAN) that utilizes an all-to-one mapping to convert early frames into those with tracer distribution similar to the last reference frame. The TAI-GAN consists of a feature-wise linear modulation layer that encodes channel-wise parameters generated from temporal information and rough cardiac segmentation masks with local shifts that serve as anatomical information. Our proposed method was evaluated on a clinical 82Rb PET dataset, and the results show that our TAI-GAN can produce converted early frames with high image quality, comparable to the real reference frames. After TAI-GAN conversion, the motion estimation accuracy and subsequent myocardial blood flow (MBF) quantification with both conventional and deep learning-based motion correction methods were improved compared to using the original frames. The code is available at https://github.com/gxq1998/TAI-GAN.

3.
Phys Med Biol ; 2024 May 30.
Article in English | MEDLINE | ID: mdl-38815617

ABSTRACT

Objective Peripheral Vascular Disease (PVD) affects more than 230 million people worldwide and is one of the leading causes of disability among people over age 60. Nowadays, PVD remains largely underdiagnosed and undertreated, and requires the development of tailored diagnostic approaches. We present the full design of the Dynamic Extremity SPECT (DE-SPECT) system, the first organ-dedicated SPECT system for lower extremity imaging, based on 1-cm thick Cadmium Zinc Telluride (CZT) spectrometers and a dynamic dual field-of-view (FOV) synthetic compound-eye collimator. Approach The proposed DE-SPECT detection system consists of 48 1-cm thick 3D-position-sensitive CZT spectrometers arranged in a partial ring of 59 cm in diameter in a checkerboard pattern. The detection system is coupled with a compact dynamic synthetic compound-eye (SCE) collimator that allows the user to select between two different FOVs at any time during an imaging study: a wide-FOV (28-cm diameter) configuration for dual-leg or scout imaging or a high-resolution and high-sensitivity (HR-HS) FOV (16-cm diameter) for single-leg or focused imaging. Main Results The preliminary experimental data show that the CZT spectrometer achieves a 3D intrinsic spatial resolution of <0.75 mm FWHM and an excellent energy resolution over a broad energy range (2.6 keV FWHM at 218 keV, 3.3 keV at 440 keV). From simulations, the wide-FOV configuration offers a 0.034% averaged sensitivity at 140 keV and <8 mm spatial resolution, whereas the HR-HS configuration presents a peak central sensitivity of 0.07% at 140 keV and a ~5 mm spatial resolution. The dynamic SCE collimator enables the capability to perform joint reconstructions that would ensure an overall improvement in imaging performance. Significance The DE-SPECT system is a stationary and high-performance SPECT system that offers an excellent spectroscopic performance with a unique computer-controlled dual-FOV imaging capability, and a relatively high sensitivity for multi-tracer and multi-functional SPECT imaging of the extremities.

4.
Am Heart J Plus ; 42: 100400, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38779485

ABSTRACT

Peripheral artery disease (PAD) is a highly prevalent disorder with a high risk of mortality and amputation despite the introduction of novel medical and procedural treatments. Microvascular disease (MVD) is common among patients with PAD, and despite the established role as a predictor of amputations and mortality, MVD is not routinely assessed as part of current standard practice. Recent pre-clinical and clinical perfusion and molecular imaging studies have confirmed the important role of MVD in the pathogenesis and outcomes of PAD. The recent advancements in the imaging of the peripheral microcirculation could lead to a better understanding of the pathophysiology of PAD, and result in improved risk stratification, and our evaluation of response to therapies. In this review, we will discuss the current understanding of the anatomy and physiology of peripheral microcirculation, and the role of imaging for assessment of perfusion in PAD, and the latest advancements in molecular imaging. By highlighting the latest advancements in multi-modality imaging of the peripheral microcirculation, we aim to underscore the most promising imaging approaches and highlight potential research opportunities, with the goal of translating these approaches for improved and personalized management of PAD in the future.

5.
IEEE Trans Med Imaging ; PP2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38578853

ABSTRACT

Single-Photon Emission Computed Tomography (SPECT) is widely applied for the diagnosis of coronary artery diseases. Low-dose (LD) SPECT aims to minimize radiation exposure but leads to increased image noise. Limited-view (LV) SPECT, such as the latest GE MyoSPECT ES system, enables accelerated scanning and reduces hardware expenses but degrades reconstruction accuracy. Additionally, Computed Tomography (CT) is commonly used to derive attenuation maps (µ-maps) for attenuation correction (AC) of cardiac SPECT, but it will introduce additional radiation exposure and SPECT-CT misalignments. Although various methods have been developed to solely focus on LD denoising, LV reconstruction, or CT-free AC in SPECT, the solution for simultaneously addressing these tasks remains challenging and under-explored. Furthermore, it is essential to explore the potential of fusing cross-domain and cross-modality information across these interrelated tasks to further enhance the accuracy of each task. Thus, we propose a Dual-Domain Coarse-to-Fine Progressive Network (DuDoCFNet), a multi-task learning method for simultaneous LD denoising, LV reconstruction, and CT-free µ-map generation of cardiac SPECT. Paired dual-domain networks in DuDoCFNet are cascaded using a multi-layer fusion mechanism for cross-domain and cross-modality feature fusion. Two-stage progressive learning strategies are applied in both projection and image domains to achieve coarse-to-fine estimations of SPECT projections and CT-derived µ-maps. Our experiments demonstrate DuDoCFNet's superior accuracy in estimating projections, generating µ-maps, and AC reconstructions compared to existing single- or multi-task learning methods, under various iterations and LD levels. The source code of this work is available at https://github.com/XiongchaoChen/DuDoCFNet-MultiTask.

6.
J Nucl Med ; 65(5): 768-774, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38548351

ABSTRACT

Heart failure (HF) is a leading cause of morbidity and mortality in the United States and worldwide, with a high associated economic burden. This study aimed to assess whether artificial intelligence models incorporating clinical, stress test, and imaging parameters could predict hospitalization for acute HF exacerbation in patients undergoing SPECT/CT myocardial perfusion imaging. Methods: The HF risk prediction model was developed using data from 4,766 patients who underwent SPECT/CT at a single center (internal cohort). The algorithm used clinical risk factors, stress variables, SPECT imaging parameters, and fully automated deep learning-generated calcium scores from attenuation CT scans. The model was trained and validated using repeated hold-out (10-fold cross-validation). External validation was conducted on a separate cohort of 2,912 patients. During a median follow-up of 1.9 y, 297 patients (6%) in the internal cohort were admitted for HF exacerbation. Results: The final model demonstrated a higher area under the receiver-operating-characteristic curve (0.87 ± 0.03) for predicting HF admissions than did stress left ventricular ejection fraction (0.73 ± 0.05, P < 0.0001) or a model developed using only clinical parameters (0.81 ± 0.04, P < 0.0001). These findings were confirmed in the external validation cohort (area under the receiver-operating-characteristic curve: 0.80 ± 0.04 for final model, 0.70 ± 0.06 for stress left ventricular ejection fraction, 0.72 ± 0.05 for clinical model; P < 0.001 for all). Conclusion: Integrating SPECT myocardial perfusion imaging into an artificial intelligence-based risk assessment algorithm improves the prediction of HF hospitalization. The proposed method could enable early interventions to prevent HF hospitalizations, leading to improved patient care and better outcomes.


Subject(s)
Artificial Intelligence , Heart Failure , Hospitalization , Myocardial Perfusion Imaging , Humans , Female , Male , Heart Failure/diagnostic imaging , Aged , Middle Aged , Acute Disease , Single Photon Emission Computed Tomography Computed Tomography , Disease Progression , Cohort Studies
7.
Am J Physiol Heart Circ Physiol ; 326(5): H1304-H1323, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38517227

ABSTRACT

Peripheral artery disease (PAD) is a common vascular disease that primarily affects the lower limbs and is defined by the constriction or blockage of peripheral arteries and may involve microvascular dysfunction and tissue injury. Patients with diabetes have more prominent disease of microcirculation and develop peripheral neuropathy, autonomic dysfunction, and medial vascular calcification. Early and accurate diagnosis of PAD and disease characterization are essential for personalized management and therapy planning. Magnetic resonance imaging (MRI) provides excellent soft tissue contrast and multiplanar imaging capabilities and is useful as a noninvasive imaging tool in the comprehensive physiological assessment of PAD. This review provides an overview of the current state of the art of MRI in the evaluation and characterization of PAD, including an analysis of the many applicable MR imaging techniques, describing the advantages and disadvantages of each approach. We also present recent developments, future clinical applications, and future MRI directions in assessing PAD. The development of new MR imaging technologies and applications in preclinical models with translation to clinical research holds considerable potential for improving the understanding of the pathophysiology of PAD and clinical applications for improving diagnostic precision, risk stratification, and treatment outcomes in patients with PAD.


Subject(s)
Magnetic Resonance Imaging , Peripheral Arterial Disease , Humans , Peripheral Arterial Disease/physiopathology , Peripheral Arterial Disease/diagnostic imaging , Animals , Predictive Value of Tests , Prognosis
8.
Article in English | MEDLINE | ID: mdl-38445511

ABSTRACT

AIMS: Variation in diagnostic performance of SPECT myocardial perfusion imaging (MPI) has been observed, yet the impact of cardiac size has not been well characterized. We assessed whether low left ventricular volume influences SPECT MPI's ability to detect obstructive coronary artery disease (CAD), and its interaction with age and sex. METHODS AND RESULTS: A total of 2,066 patients without known CAD (67% male, 64.7 ± 11.2 years) across 9 institutions underwent SPECT MPI with solid-state scanners followed by coronary angiography as part of the REgistry of Fast Myocardial Perfusion Imaging with NExt Generation SPECT. Area under receiver-operating characteristic curve (AUC) analyses evaluated performance of quantitative and visual assessments according to cardiac size (end- diastolic volume [EDV]; < 20th vs. ≥ 20th population or sex-specific percentiles), age (<75 vs. ≥ 75 years), and sex. Significantly decreased performance was observed in patients with low EDV compared to those without (AUC: population 0.72 vs. 0.78, p = 0.03; sex-specific 0.72 vs. 0.79, p = 0.01) and elderly patients compared to younger patients (AUC 0.72 vs. 0.78, p = 0.03), whereas males and females demonstrated similar AUC (0.77 vs. 0.76, p = 0.67). The reduction in accuracy attributed to lower volumes was primarily observed in males (sex-specific threshold: EDV 0.69 vs. 0.79, p = 0.01). Accordingly, a significant decrease in AUC, sensitivity, specificity, and negative predictive value for quantitative and visual assessments was noted in patients with at least two characteristics of low EDV, elderly age, or male sex. CONCLUSIONS: Detection of CAD with SPECT MPI is negatively impacted by small cardiac size, most notably in elderly and male patients.

10.
IEEE Trans Med Imaging ; 43(5): 2010-2020, 2024 May.
Article in English | MEDLINE | ID: mdl-38231820

ABSTRACT

Characterizing left ventricular deformation and strain using 3D+time echocardiography provides useful insights into cardiac function and can be used to detect and localize myocardial injury. To achieve this, it is imperative to obtain accurate motion estimates of the left ventricle. In many strain analysis pipelines, this step is often accompanied by a separate segmentation step; however, recent works have shown both tasks to be highly related and can be complementary when optimized jointly. In this work, we present a multi-task learning network that can simultaneously segment the left ventricle and track its motion between multiple time frames. Two task-specific networks are trained using a composite loss function. Cross-stitch units combine the activations of these networks by learning shared representations between the tasks at different levels. We also propose a novel shape-consistency unit that encourages motion propagated segmentations to match directly predicted segmentations. Using a combined synthetic and in-vivo 3D echocardiography dataset, we demonstrate that our proposed model can achieve excellent estimates of left ventricular motion displacement and myocardial segmentation. Additionally, we observe strong correlation of our image-based strain measurements with crystal-based strain measurements as well as good correspondence with SPECT perfusion mappings. Finally, we demonstrate the clinical utility of the segmentation masks in estimating ejection fraction and sphericity indices that correspond well with benchmark measurements.


Subject(s)
Echocardiography, Three-Dimensional , Heart Ventricles , Humans , Echocardiography, Three-Dimensional/methods , Heart Ventricles/diagnostic imaging , Algorithms , Machine Learning
11.
EBioMedicine ; 99: 104930, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38168587

ABSTRACT

BACKGROUND: Myocardial perfusion imaging (MPI) is one of the most common cardiac scans and is used for diagnosis of coronary artery disease and assessment of cardiovascular risk. However, the large majority of MPI patients have normal results. We evaluated whether unsupervised machine learning could identify unique phenotypes among patients with normal scans and whether those phenotypes were associated with risk of death or myocardial infarction. METHODS: Patients from a large international multicenter MPI registry (10 sites) with normal perfusion by expert visual interpretation were included in this cohort analysis. The training population included 9849 patients, and external testing population 12,528 patients. Unsupervised cluster analysis was performed, with separate training and external testing cohorts, to identify clusters, with four distinct phenotypes. We evaluated the clinical and imaging features of clusters and their associations with death or myocardial infarction. FINDINGS: Patients in Clusters 1 and 2 almost exclusively underwent exercise stress, while patients in Clusters 3 and 4 mostly required pharmacologic stress. In external testing, the risk for Cluster 4 patients (20.2% of population, unadjusted hazard ratio [HR] 6.17, 95% confidence interval [CI] 4.64-8.20) was higher than the risk associated with pharmacologic stress (HR 3.03, 95% CI 2.53-3.63), or previous myocardial infarction (HR 1.82, 95% CI 1.40-2.36). INTERPRETATION: Unsupervised learning identified four distinct phenotypes of patients with normal perfusion scans, with a significant proportion of patients at very high risk of myocardial infarction or death. Our results suggest a potential role for patient phenotyping to improve risk stratification of patients with normal imaging results. FUNDING: This work was supported by the National Heart, Lung, and Blood Institute at the National Institutes of Health [R35HL161195 to PS]. The REFINE SPECT database was supported by the National Heart, Lung, and Blood Institute at the National Institutes of Health [R01HL089765 to PS]. MCW was supported by the British Heart Foundation [FS/ICRF/20/26002].


Subject(s)
Coronary Artery Disease , Myocardial Infarction , Humans , Coronary Artery Disease/diagnostic imaging , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/etiology , Perfusion , Prognosis , Risk Factors , Unsupervised Machine Learning , Retrospective Studies
12.
J Vasc Surg Venous Lymphat Disord ; 12(2): 101731, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38081514

ABSTRACT

OBJECTIVE: Although inferior vena cava (IVC) filters are commonly retrieved using a snare, lateral tilt and fibrosis around struts can complicate the procedure and sometimes require the use of off-label devices. We describe the development of a novel articulating endovascular grasper designed to remove permanent and retrievable IVC filters in any configuration. METHODS: For in vitro testing, the IVC filters were anchored to the inner wall of a flexible tube in a centered or tilted configuration. A high-contrast backlit camera view simulated the two-dimensional fluoroscopy projection during retrieval. The time from the retrieval device introduction into the camera field to complete filter retrieval was measured in seconds. The control experiment involved temporary IVC filter retrieval with a snare. There were four comparative groups: (1) retrievable filter in centered configuration; (2) retrievable filter in tilted configuration; (3) permanent filter in centered configuration; and (4) permanent filter in tilted configuration. Every experiment was repeated five times, with median retrieval time compared with the control group. For in vivo testing in a porcine model, six tilted infrarenal IVC filters were retrieved with grasper via right jugular approach. Comparison analysis between animal and patient procedures was performed for the following variables: total procedure time, the retrieval time, and fluoroscopy time. RESULTS: The in vitro experiments showed comparable retrieval times between the experimental groups 1, 2, and 4 and the control. However, grasper removal of a centered permanent filter (group 3) required significantly less time than in the control (29 vs 79 seconds; P = .009). In the animal model, all IVC filters were retrieved using the grasper with no adverse events. The total procedure time (21.2 vs 43.5 minutes; P = .01) and the fluoroscopy time (4.3 vs 10 minutes; P = .044) were significantly shorter in the animal model compared with the patient group. Moreover, in the patient group, 16.7% of retrievals required advanced endovascular techniques, and one IVC filter could not be retrieved (success rate = 91.7%), whereas all the IVC filters were successfully retrieved in the animal model without the use of additional tools. CONCLUSIONS: The novel endovascular grasper is effective in retrieving different types of IVC filters in different configurations and compared favorably with the snare in the in vitro model. In vivo experiments demonstrated more effective retrieval when compared with matched patient retrievals.


Subject(s)
Endovascular Procedures , Vena Cava Filters , Humans , Animals , Swine , Vena Cava Filters/adverse effects , Device Removal/adverse effects , Retrospective Studies , Time Factors , Endovascular Procedures/adverse effects , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Treatment Outcome
13.
Biochem Pharmacol ; 219: 115914, 2024 01.
Article in English | MEDLINE | ID: mdl-37956895

ABSTRACT

An important mechanism for cancer progression is degradation of the extracellular matrix (ECM) which is accompanied by the emergence and proliferation of an activated fibroblast, termed the cancer associated fibroblast (CAF). More specifically, an enzyme pathway identified to be amplified with local cancer progression and proliferation of the CAF, is fibroblast activation protein (FAP). The development and progression of heart failure (HF) irrespective of the etiology is associated with left ventricular (LV) remodeling and changes in ECM structure and function. As with cancer, HF progression is associated with a change in LV myocardial fibroblast growth and function, and expresses a protein signature not dissimilar to the CAF. The overall goal of this review is to put forward the postulate that scientific discoveries regarding FAP in cancer as well as the development of specific chemotherapeutics could be pivoted to target the emergence of FAP in the activated fibroblast subtype and thus hold translationally relevant diagnostic and therapeutic targets in HF.


Subject(s)
Heart Failure , Neoplasms , Humans , Heart Failure/drug therapy , Heart Failure/metabolism , Myocardium/metabolism , Fibroblasts/metabolism , Extracellular Matrix/metabolism , Neoplasms/metabolism , Ventricular Remodeling
14.
Int J Cardiovasc Imaging ; 40(1): 185-193, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37845406

ABSTRACT

We investigated the prognostic utility of visually estimated coronary artery calcification (VECAC) from low dose computed tomography attenuation correction (CTAC) scans obtained during SPECT/CT myocardial perfusion imaging (MPI), and assessed how it compares to coronary artery calcifications (CAC) quantified by calcium score on CTACs (QCAC). From the REFINE SPECT Registry 4,236 patients without prior coronary stenting with SPECT/CT performed at a single center were included (age: 64 ± 12 years, 47% female). VECAC in each coronary artery (left main, left anterior descending, circumflex, and right) were scored separately as 0 (absent), 1 (mild), 2 (moderate), or 3 (severe), yielding a possible score of 0-12 for each patient (overall VECAC grade zero:0, mild:1-2, moderate: 3-5, severe: >5). CAC scoring of CTACs was performed at the REFINE SPECT core lab with dedicated software. VECAC was correlated with categorized QCAC (zero: 0, mild: 1-99, moderate: 100-399, severe: ≥400). A high degree of correlation was observed between VECAC and QCAC, with 73% of VECACs in the same category as QCAC and 98% within one category. There was substantial agreement between VECAC and QCAC (weighted kappa: 0.78 with 95% confidence interval: 0.76-0.79, p < 0.001). During a median follow-up of 25 months, 372 patients (9%) experienced major adverse cardiovascular events (MACE). In survival analysis, both VECAC and QCAC were associated with MACE. The area under the receiver operating characteristic curve for 2-year-MACE was similar for VECAC when compared to QCAC (0.694 versus 0.691, p = 0.70). In conclusion, visual assessment of CAC on low-dose CTAC scans provides good estimation of QCAC in patients undergoing SPECT/CT MPI. Visually assessed CAC has similar prognostic value for MACE in comparison to QCAC.


Subject(s)
Calcinosis , Coronary Artery Disease , Myocardial Perfusion Imaging , Humans , Female , Middle Aged , Aged , Male , Myocardial Perfusion Imaging/methods , Prognosis , Predictive Value of Tests , Tomography, Emission-Computed, Single-Photon/methods , Coronary Artery Disease/diagnostic imaging , Tomography, X-Ray Computed/methods
15.
Eur J Nucl Med Mol Imaging ; 51(3): 695-706, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37924340

ABSTRACT

PURPOSE: This study aimed to compare the predictive value of CT attenuation-corrected stress total perfusion deficit (AC-sTPD) and non-corrected stress TPD (NC-sTPD) for major adverse cardiac events (MACE) in obese patients undergoing cadmium zinc telluride (CZT) SPECT myocardial perfusion imaging (MPI). METHODS: The study included 4,585 patients who underwent CZT SPECT/CT MPI for clinical indications (chest pain: 56%, shortness of breath: 13%, other: 32%) at Yale New Haven Hospital (age: 64 ± 12 years, 45% female, body mass index [BMI]: 30.0 ± 6.3 kg/m2, prior coronary artery disease: 18%). The association between AC-sTPD or NC-sTPD and MACE defined as the composite end point of mortality, nonfatal myocardial infarction or late coronary revascularization (> 90 days after SPECT) was evaluated with survival analysis. RESULTS: During a median follow-up of 25 months, 453 patients (10%) experienced MACE. In patients with BMI ≥ 35 kg/m2 (n = 931), those with AC-sTPD ≥ 3% had worse MACE-free survival than those with AC-sTPD < 3% (HR: 2.23, 95% CI: 1.40 - 3.55, p = 0.002) with no difference in MACE-free survival between patients with NC-sTPD ≥ 3% and NC-sTPD < 3% (HR:1.06, 95% CI:0.67 - 1.68, p = 0.78). AC-sTPD had higher AUC than NC-sTPD for the detection of 2-year MACE in patients with BMI ≥ 35 kg/m2 (0.631 versus 0.541, p = 0.01). In the overall cohort AC-sTPD had a higher ROC area under the curve (AUC, 0.641) than NC-sTPD (0.608; P = 0.01) for detection of 2-year MACE. In patients with BMI ≥ 35 kg/m2 AC sTPD provided significant incremental prognostic value beyond NC sTPD (net reclassification index: 0.14 [95% CI: 0.20 - 0.28]). CONCLUSIONS: AC sTPD outperformed NC sTPD in predicting MACE in patients undergoing SPECT MPI with BMI ≥ 35 kg/m2. These findings highlight the superior prognostic value of AC-sTPD in this patient population and underscore the importance of CT attenuation correction.


Subject(s)
Coronary Artery Disease , Myocardial Infarction , Myocardial Perfusion Imaging , Humans , Female , Middle Aged , Aged , Male , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Tomography, Emission-Computed, Single-Photon/methods , Myocardial Perfusion Imaging/methods , Tomography, X-Ray Computed , Prognosis , Obesity/complications , Obesity/diagnostic imaging
17.
IEEE Trans Radiat Plasma Med Sci ; 7(1): 33-40, 2023 Jan.
Article in English | MEDLINE | ID: mdl-37397179

ABSTRACT

Convolutional neural networks (CNNs) have been extremely successful in various medical imaging tasks. However, because the size of the convolutional kernel used in a CNN is much smaller than the image size, CNN has a strong spatial inductive bias and lacks a global understanding of the input images. Vision Transformer, a recently emerged network structure in computer vision, can potentially overcome the limitations of CNNs for image-reconstruction tasks. In this work, we proposed a slice-by-slice Transformer network (SSTrans-3D) to reconstruct cardiac SPECT images from 3D few-angle data. To be specific, the network reconstructs the whole 3D volume using a slice-by-slice scheme. By doing so, SSTrans-3D alleviates the memory burden required by 3D reconstructions using Transformer. The network can still obtain a global understanding of the image volume with the Transformer attention blocks. Lastly, already reconstructed slices are used as the input to the network so that SSTrans-3D can potentially obtain more informative features from these slices. Validated on porcine, phantom, and human studies acquired using a GE dedicated cardiac SPECT scanner, the proposed method produced images with clearer heart cavity, higher cardiac defect contrast, and more accurate quantitative measurements on the testing data as compared with a deep U-net.

19.
Am J Physiol Heart Circ Physiol ; 325(3): H492-H509, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37417870

ABSTRACT

We present a detailed analysis of regional myocardial blood flow and work to better understand the effects of coronary stenoses and low-dose dobutamine stress. Our analysis is based on a unique open-chest model in anesthetized canines that features invasive hemodynamic monitoring, microsphere-based blood flow analysis, and an extensive three-dimensional (3-D) sonomicrometer array that provides multiaxial deformational assessments in the ischemic, border, and remote vascular territories. We use this model to construct regional pressure-strain loops for each territory and quantify the loop subcomponent areas that reflect myocardial work contributing to the ejection of blood and wasted work that does not. We demonstrate that reductions in coronary blood flow markedly alter the shapes and temporal relationships of pressure-strain loops, as well as the magnitudes of their total and subcomponent areas. Specifically, we show that moderate stenoses in the mid-left anterior descending coronary artery decrease regional midventricle myocardial work indices and substantially increase indices of wasted work. In the midventricle, these effects are most pronounced along the radial and longitudinal axes, with more modest effects along the circumferential axis. We further demonstrate that low-dose dobutamine can help to restore or even improve function, but often at the cost of increased wasted work. This detailed, multiaxial analysis provides unique insight into the physiology and mechanics of the heart in the presence of ischemia and low-dose dobutamine, with potential implications in many areas, including the detection and characterization of ischemic heart disease and the use of inotropic support for low cardiac output.NEW & NOTEWORTHY Our unique experimental model assesses cardiac pressure-strain relationships along multiple axes in multiple regions. We demonstrate that moderate coronary stenoses decrease regional myocardial work and increase wasted work and that low-dose dobutamine can help to restore myocardial function, but often with further increases in wasted work. Our findings highlight the significant directional variation of cardiac mechanics and demonstrate potential advantages of pressure-strain analyses over traditional, purely deformational measures, especially in characterizing physiological changes related to dobutamine.


Subject(s)
Coronary Stenosis , Myocardial Ischemia , Animals , Dogs , Dobutamine/pharmacology , Myocardium , Heart , Coronary Circulation , Myocardial Contraction
20.
J Appl Physiol (1985) ; 135(2): 405-420, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37318987

ABSTRACT

Myocardial infarction (MI) is often complicated by left ventricular (LV) remodeling and heart failure. We evaluated the feasibility of a multimodality imaging approach to guide delivery of an imageable hydrogel and assessed LV functional changes with therapy. Yorkshire pigs underwent surgical occlusions of branches of the left anterior descending and/or circumflex artery to create an anterolateral MI. We evaluated the hemodynamic and mechanical effects of intramyocardial delivery of an imageable hydrogel in the central infarct area (Hydrogel group, n = 8) and a Control group (n = 5) early post-MI. LV and aortic pressure and ECG were measured and contrast cineCT angiography was performed at baseline, 60 min post-MI, and 90 min post-hydrogel delivery. LV hemodynamic indices, pressure-volume measures, and normalized regional and global strains were measured and compared. Both Control and Hydrogel groups demonstrated a decline in heart rate, LV pressure, stroke volume, ejection fraction, and pressure-volume loop area, and an increase in myocardial performance (Tei) index and supply/demand (S/D) ratio. After hydrogel delivery, Tei index and S/D ratio were reduced to baseline levels, diastolic and systolic functional indices either stabilized or improved, and radial strain and circumferential strain increased significantly in the MI regions (ENrr: +52.7%, ENcc: +44.1%). However, the Control group demonstrated a progressive decline in all functional indices to levels significantly below those of Hydrogel group. Thus, acute intramyocardial delivery of a novel imageable hydrogel to MI region resulted in rapid stabilization or improvement in LV hemodynamics and function.NEW & NOTEWORTHY Our study demonstrates that contrast cineCT imaging can be used to evaluate the acute effects of intramyocardial delivery of a therapeutic hydrogel to the central MI region early post MI, which resulted in a rapid stabilization of LV hemodynamics and improvement in regional and global LV function.


Subject(s)
Hydrogels , Myocardial Infarction , Swine , Animals , Hydrogels/pharmacology , Precision Medicine , Myocardium , Ventricular Function, Left , Ventricular Remodeling/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...