2.
Interv Neuroradiol ; 28(6): 746-755, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35818746

ABSTRACT

PURPOSE: Various adjunctive devices have been reported to be helpful during the endovascular coiling of complex, wide-necked cerebral aneurysms. This study aimed to describe the utilization of a recently introduced intrasaccular neck-bridging implant specifically designed to facilitate coil embolization. METHODS: We retrospectively reviewed eight consecutive patients who underwent treatment for intracranial aneurysms with the Nautilus intrasaccular bridging system between February 2022 to May 2022. We evaluated the angiographic appearances of treated aneurysms at the end of the procedure and early follow-up, the clinical status and complications. RESULTS: Eight patients with eight cerebral aneurysms (3 men and 5 women, mean age 52.8 years (range 39-66) were analyzed. Five of the treated aneurysms were managed in an acute case scenario. There were no technical difficulties while executing the technique. No other procedural adverse events were documented. Immediate complete occlusion of the aneurysm was seen in 6 patients, neck remnant in 1 and stable aneurysm reperfusion in one case. Early radiological follow-up was available in five patients, and the observed occlusion rates were - RR class I in all radiologically screened aneurysms. CONCLUSION: Nautilus-assisted coil embolization represents a rapid and safe solution for complex cerebral aneurysms. In our opinion this device symbolizes a significant step forward in treating intracranial aneurysms. We believe that the technique's actual value consists of the fact that the device is fully compatible with the modern low-profile microcatheter technology and does not involve the need for antiplatelet medications.


Subject(s)
Embolization, Therapeutic , Intracranial Aneurysm , Nautilus , Male , Animals , Humans , Female , Adult , Middle Aged , Aged , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Intracranial Aneurysm/complications , Embolization, Therapeutic/methods , Feasibility Studies , Retrospective Studies , Stents/adverse effects , Treatment Outcome , Cerebral Angiography
3.
Clin Neuroradiol ; 32(3): 773-782, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35041011

ABSTRACT

BACKGROUND AND PURPOSE: Recently, avant-garde combinations of ancillary devices as an adjunct to coil embolization for acutely ruptured and wide-necked cerebral aneurysms have emerged. This study sought to investigate the feasibility, safety and durability of the simultaneous combination of temporary neck-bridging devices plus balloon-assisted coiling (BAC) to treat acutely ruptured and wide-necked cerebral aneurysms. METHODS: A retrospective review was performed of patients with ruptured and wide-necked intracranial bifurcation aneurysms treated with temporary stent plus balloon-assisted coiling. Anatomical features, technical details, intraprocedural complications, clinical and angiographic results were reviewed. Preprocedural and follow-up clinical statuses were evaluated using the modified Rankin scale (mRS). RESULTS: A total of 21 patients (mean age 54.5 years, range 37-72 years) were identified. The immediate postprocedural angiography revealed complete aneurysm occlusion in 85.7% (18/21) of the cases. A periprocedural complication developed in 9.5% of the cases. There was no mortality in this study. The permanent morbidity rate was 4.7%. Long-term follow-up angiography was performed in 18 of 21 patients (85.7%) (the mean follow-up period was 21 months). The rate of complete aneurysm occlusion at final follow-up was 89.4%. CONCLUSION: The results of this study confirmed that temporary stent plus balloon-assisted coiling is a durable and relatively safe endovascular technique for the treatment of ruptured wide-necked bifurcation aneurysms located in both the posterior and anterior cerebral circulation.


Subject(s)
Aneurysm, Ruptured , Embolization, Therapeutic , Intracranial Aneurysm , Stroke , Adult , Aged , Cerebral Angiography , Humans , Middle Aged , Retrospective Studies , Stents , Treatment Outcome
4.
AJNR Am J Neuroradiol ; 42(2): 319-326, 2021 01.
Article in English | MEDLINE | ID: mdl-33303523

ABSTRACT

BACKGROUND AND PURPOSE: Stent-assisted treatment techniques can be an effective treatment option for intracranial aneurysms. The aim of this study was to evaluate the periprocedural feasibility and safety of the new LVIS EVO stent for the treatment of intracranial aneurysms. MATERIALS AND METHODS: Patients with intracranial aneurysms treated with the LVIS EVO in 11 European neurovascular centers were retrospectively reviewed. Patient and aneurysm characteristics, procedural parameters, immediate grade of occlusion, and technical and clinical complications were assessed. RESULTS: Fifty-seven patients with 59 aneurysms were treated with the LVIS EVO device; 57.6% of the aneurysms were incidental; 15.3% were acutely ruptured; 15.3% were recanalized or residual aneurysms; and 11.9% were treated for symptoms other than acute hemorrhage. The most frequent aneurysm locations were the middle cerebral artery (25.4%) and the anterior communicating artery (22.0%). The rate of immediate successful deployment was 93.2%. In 6.8% (n = 4) of cases, additional in-stent angioplasty was needed. The immediate complete occlusion rate was 54.2%, while there was a residual aneurysm in 35.6% and a residual neck in 10.2%. Periprocedural technical complications occurred in 7/59 treatments (11.9%; the most frequent technical complication [n = 3] was thrombus formation), which all resolved completely without clinical sequelae. Postprocedural neurologic complications occurred after 4/59 treatments (6.8%; 2 transient ischemic attacks, 1 minor stroke, 1 major stroke), of which only 1 persistent complication was directly related to the procedure (minor stroke in the vascular territory distal to the stent). CONCLUSIONS: The LVIS EVO stent is a safe, feasible device for the treatment of intracranial aneurysms.


Subject(s)
Endovascular Procedures/instrumentation , Intracranial Aneurysm/surgery , Postoperative Complications/epidemiology , Stents , Adult , Aged , Endovascular Procedures/methods , Feasibility Studies , Female , Humans , Male , Middle Aged , Postoperative Complications/etiology , Retrospective Studies , Stents/adverse effects , Treatment Outcome
5.
AJNR Am J Neuroradiol ; 41(4): 681-686, 2020 04.
Article in English | MEDLINE | ID: mdl-32165357

ABSTRACT

BACKGROUND AND PURPOSE: Conventional nonadhesive liquid embolic agents currently are the criterion standard for endovascular embolization of cerebral AVMs. However, inadequate distal penetration into the nidus and unstable proximal plug formation are the major limitations of this approach and of the currently available embolic materials. The aim of this study was to evaluate the hypothetic efficacy of combining liquid embolic agents with different properties and viscosities for use in endovascular embolization of cerebral AVMs. MATERIALS AND METHODS: From March 2018 to March 2019, sixteen patients with cerebral AVMs (12 women, 4 men; age range, 33-61 years) underwent endovascular embolization with combined liquid embolic agents delivered serially via a single microcatheter. The procedure consists of initial embolization with PHIL 30%, followed by Menox 18 through the same microcatheter. According to the Spetzler-Martin scale, 11 (68.75%) AVMs were grades I-II, 4 (25%) were grade III, and 1 (6.25%) was grade IV. Angiographic, technical, and clinical outcomes were analyzed independently. RESULTS: Combined PHIL and Menox embolization through the same microcatheter via 21 pedicles was performed in these 16 patients. Once the length of the reflux reached approximately 2 cm, PHIL 30% was switched to Menox 18. Antegrade flow and distal penetration of the serially applied liquid embolic agents were observed in all 16 cases. The ability to completely control the flow of the materials and avoid any dangerous proximal reflux was noted in all performed embolizations. The estimated average size reduction of the treated AVMs was 85%, ranging from 50% to 100%. Complete embolization was achieved in 10/16 or 62.5% of the cases. There was no procedure-related complication during or after the embolization. No mortality or postprocedural clinical worsening was seen. Clinical success and complete obliteration were confirmed with at least 1 follow-up angiography in 10/16 patients. CONCLUSIONS: Serial delivery of nonadhesive liquid embolic agents via the same microcatheter was safe and effective in our study and may be a potential technique for routine AVM treatment. However, further investigations are required to validate the safety and the efficacy of the method.


Subject(s)
Arteriovenous Fistula/therapy , Dimethyl Sulfoxide/administration & dosage , Embolization, Therapeutic/methods , Intracranial Arteriovenous Malformations/therapy , Polyvinyls/administration & dosage , Adult , Catheters , Female , Humans , Male , Middle Aged , Treatment Outcome
7.
Clin Neuroradiol ; 30(3): 471-480, 2020 Sep.
Article in English | MEDLINE | ID: mdl-31399749

ABSTRACT

BACKGROUND AND PURPOSE: The p64 is a flow modulation device designed to be used in endovascular treatment of intracranial aneurysms. There is limited data on the long-term effectiveness of the device. This study sought to determine the safety and long-term efficacy of this device. METHODS: A retrospective review of a prospectively maintained database was performed to identify all patients treated with a p64 between March 2015 and November 2018 at University Hospital St. Ivan Rilski. Anatomical features, intraprocedural complications, clinical, and angiographic outcomes were also taken into account and reviewed. RESULTS: A total of 72 patients with 72 aneurysms who met the inclusion criteria were identified. Device placement was successful in all patients. Follow-up angiographic imaging at 6 months showed complete occlusion (O'Kelly-Marotta scale [OKM] D) in 55 (76.3%) patients, subtotal aneurysmal filling (OKM B) in 10 (13.8%) patients, and neck remnant (OKM C) in 7 (9.7%) patients. Catheter angiography at 12 months was available for 70 patients (97.2%) and of these patients 91.4% of the aneurysms were completely occluded (OKM D) (64/72). Delayed angiography at 24 months was available for 68 patients (94.4%) and of these 98.5% (67/68) had completely occluded aneurysms. A 36-month angiography was available for 61 patients (84.4%) by which point all aneurysms had been completely occluded (100%). Permanent morbidity due to delayed aneurysmal rupture occurred in one patient (1.38%). The mortality rate was 0%. Self-limiting mild intimal hyperplasia was seen in 2 patients (2.72%). CONCLUSION: Treatment of intracranial aneurysms with a p64 flow modulation device is safe and effective with a high success rate and only infrequent complications.


Subject(s)
Endovascular Procedures/instrumentation , Intracranial Aneurysm/therapy , Stents , Adult , Aged , Aged, 80 and over , Cerebral Angiography , Female , Humans , Intracranial Aneurysm/diagnostic imaging , Male , Middle Aged , Retrospective Studies
8.
Radiol Case Rep ; 13(5): 1036-1041, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30228839

ABSTRACT

Bilateral ophthalmic-ethmoidal dural arteriovenous fistulas (DAVFs) are extremely rare and may present as complex lesions. These DAVFs are associated with high risk of intracranial hemorrhage but can be presented with ocular symptoms, cranial nerve palsy or epistaxis. Endovascular approaches have been used to manage an increasing proportion of complex intracranial DAVFs safely and with good clinical results. We present a patient with subdural hematoma and severe epistaxis due to ruptured bilateral ophthalmic-ethmoidal DAVF that was successfully treated by transarterial embolization with precipitating hydrophobic injectable liquid.

SELECTION OF CITATIONS
SEARCH DETAIL
...