Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
Front Cardiovasc Med ; 9: 861129, 2022.
Article in English | MEDLINE | ID: mdl-35369311

ABSTRACT

Aim: The aim of this study was to explore the potential intraprocedural benefits of the Proximal Side Optimization (PSO) technique by Optical Coherence Tomography (OCT). Methods: A case series of 10 consecutive true bifurcation lesions, with severe long pathology of long side branch (SB), were randomly assigned to be treated by standard DK Crush procedure (non-PSO group) as compared to DK Crush in PSO modification (PSO group). The data from OCT investigation before crushing of the SB Drug-Eluting Stent (DES), after crushing, after first kissing balloon inflation (KBI), and after final angiography were compared between the two groups (Public trials registry ISRCTN23355755). Results: All 10 cases were successfully treated by the assigned technique. The two groups were similar in terms of indications for the procedure, bifurcation angle, and stent dimensions. As compared to the non-PSO, the PSO group showed larger proximal SB stent areas (5.8 ± 1.8 vs. 4.5 ± 0.5 mm2; p = 0.02), the larger delta between distal and proximal stent areas before crush (1.5 ± 0.7 vs. 0.6 ± 0.5 mm2; p = 0.004), and the larger Space of Optimal Wiring (SOW) after Crush (5.3 ± 1.8 vs. 2.5 ± 1.1 mm2; p = 0.02). The gaps in scaffolding within the ostial segment of the Side Branch DES were found in two patients from the non-PSO group. Conclusion: The DK Crush in PSO modification results in larger SB DES and SOW areas with better apposition to the vessel wall. As result, the SB DES acquires a funnel shape, which reduces the risk of passage outside the SB stent struts during re-wiring, thus, allowing predictable and secure results.

2.
Catheter Cardiovasc Interv ; 100 Suppl 1: S25-S35, 2022 11.
Article in English | MEDLINE | ID: mdl-36661369

ABSTRACT

BACKGROUND: Uncovered struts are a determinant of stent failure. The impact of plaque composition and procedural factors on the occurrence, evolution, and outcomes of uncovered struts in a high-risk setting has not been investigated. OBJECTIVE: To investigate the determinants and long-term clinical impact of largely uncovered struts (LUS) in thin-struts drug-eluting stents (DES) implanted in complex lesions by intracoronary optical coherence tomography (OCT). METHODS: Ninety patients with multivessel disease undergoing staged complete revascularization were randomly assigned to bioabsorbable or durable polymer DES. OCT were serially performed during the index procedure, at 3- and 18-month follow-up, and analyzed by an independent core lab. Struts were defined uncovered by OCT if no tissue was visible above the struts. LUS were defined as ≥30% of uncovered struts at 3-month follow-up. Clinical outcomes were the occurrence of target vessel failure (TVF) and major adverse cardiac and cerebrovascular events (MACCE) at 5-year follow-up. RESULTS: LUS occurred in 31 patients (34.4%) regardless of stent platform. At 5 years, no differences were observed in the rate of TVF (12.7% vs. 13.4%; p = 0.91) and MACCE (23.9% vs. 24.9%; p = 0.88) between the two groups. At multivariate logistic regression, plaque rupture, mean lumen diameter, proximal reference vessel area, and maximum stent deployment pressure were independent predictors of LUS. CONCLUSIONS: LUS are a frequent finding in complex coronary lesions treated with thin-struts DES, especially in the presence of plaque rupture. However, in this study, no significant safety signal related to LUS emerged in long-term follow-up.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Humans , Tomography, Optical Coherence/methods , Treatment Outcome , Prosthesis Design , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/etiology , Percutaneous Coronary Intervention/adverse effects
3.
JACC Case Rep ; 3(14): 1594-1598, 2021 Oct 20.
Article in English | MEDLINE | ID: mdl-34729508

ABSTRACT

This report presents the case of fissured subepicardial hematoma and cardiac tamponade after coronary artery perforation during a complex percutaneous intervention. Surgical therapy was required to achieve hemostasis because a percutaneous sealing result was insufficient. Prompt recognition and cardiac surgery availability are essential for patient survival in such situations. (Level of Difficulty: Beginner.).

4.
Eur Heart J ; 39(26): 2448-2456, 2018 07 07.
Article in English | MEDLINE | ID: mdl-29788263

ABSTRACT

Aims: Delayed healing and endothelial dysfunction may occur with drug-eluting stents (DES), promoting accelerated infiltration of lipids in the neointima and development of neoatherosclerosis (NA). Pathology data suggest durable polymer (DP) of DES to play a major role in this process. Whether biodegradable polymer (BP) may address these issues is uncertain. We compared in vivo vessel healing and NA of current generation BP- or DP-DES using serial optical coherence tomography (OCT) assessments. Methods and results: Ninety patients with multivessel coronary artery disease were randomized 1:1 to BP everolimus-eluting stents (EES, Synergy) or DP zotarolimus-eluting stents (ZES, Resolute Integrity). Co-primary endpoints were the maximum length of uncovered struts at 3 months (powered for non-inferiority) and the percentage of patients presenting with frames of NA at 18 months (powered for superiority) as measured by OCT. The maximum length of uncovered struts at 3 months was 10 ± 8 mm in the BP-EES group and 11 ± 7 mm in the DP-ZES group (mean difference -1 mm; upper 97.5% confidence interval +2 mm; P = 0.05 for non-inferiority; P = 0.45 for superiority). The percentage of patients presenting with frames of NA at 18 months was low and similar between BP-EES and DP-ZES groups (11.6% vs. 15.9%; P = 0.56). There was no stent thrombosis in both groups at 24 months. Conclusion: BP-EES and DP-ZES showed a similar healing response at 3 months and a low incidence of NA at 18 months. Biocompatible polymers, regardless of whether they are durable or biodegradable, may favourably impact the long-term vascular response to current-generation DES.


Subject(s)
Absorbable Implants , Atherosclerosis/diagnostic imaging , Coronary Artery Disease/surgery , Drug-Eluting Stents , Neointima/diagnostic imaging , Percutaneous Coronary Intervention , Aged , Biocompatible Materials , Coronary Artery Disease/diagnostic imaging , Everolimus/administration & dosage , Female , Humans , Immunosuppressive Agents/administration & dosage , Male , Middle Aged , Sirolimus/administration & dosage , Sirolimus/analogs & derivatives , Time Factors , Tomography, Optical Coherence , Wound Healing
6.
Circulation ; 136(11): 1007-1021, 2017 Sep 12.
Article in English | MEDLINE | ID: mdl-28720725

ABSTRACT

BACKGROUND: Stent thrombosis (ST) is a serious complication following coronary stenting. Intravascular optical coherence tomography (OCT) may provide insights into mechanistic processes leading to ST. We performed a prospective, multicenter study to evaluate OCT findings in patients with ST. METHODS: Consecutive patients presenting with ST were prospectively enrolled in a registry by using a centralized telephone registration system. After angiographic confirmation of ST, OCT imaging of the culprit vessel was performed with frequency domain OCT. Clinical data were collected according to a standardized protocol. OCT acquisitions were analyzed at a core laboratory. Dominant and contributing findings were adjudicated by an imaging adjudication committee. RESULTS: Two hundred thirty-one patients presenting with ST underwent OCT imaging; 14 (6.1%) had image quality precluding further analysis. Of the remaining patients, 62 (28.6%) and 155 (71.4%) presented with early and late/very late ST, respectively. The underlying stent type was a new-generation drug-eluting stent in 50.3%. Mean reference vessel diameter was 2.9±0.6 mm and mean reference vessel area was 6.8±2.6 mm2. Stent underexpansion (stent expansion index <0.8) was observed in 44.4% of patients. The predicted average probability (95% confidence interval) that any frame had uncovered (or thrombus-covered) struts was 99.3% (96.1-99.9), 96.6% (92.4-98.5), 34.3% (15.0-60.7), and 9.6% (6.2-14.5) and malapposed struts was 21.8% (8.4-45.6), 8.5% (4.6-15.3), 6.7% (2.5-16.3), and 2.0% (1.2-3.3) for acute, subacute, late, and very late ST, respectively. The most common dominant finding adjudicated for acute ST was uncovered struts (66.7% of cases); for subacute ST, the most common dominant finding was uncovered struts (61.7%) and underexpansion (25.5%); for late ST, the most common dominant finding was uncovered struts (33.3%) and severe restenosis (19.1%); and for very late ST, the most common dominant finding was neoatherosclerosis (31.3%) and uncovered struts (20.2%). In patients presenting very late ST, uncovered stent struts were a common dominant finding in drug-eluting stents, and neoatherosclerosis was a common dominant finding in bare metal stents. CONCLUSIONS: In patients with ST, uncovered and malapposed struts were frequently observed with the incidence of both decreasing with longer time intervals between stent implantation and presentation. The most frequent dominant observation varied according to time intervals from index stenting: uncovered struts and underexpansion in acute/subacute ST and neoatherosclerosis and uncovered struts in late/very late ST.


Subject(s)
Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/prevention & control , Drug-Eluting Stents/trends , Percutaneous Coronary Intervention/trends , Research Report/trends , Tomography, Optical Coherence/trends , Aged , Coronary Thrombosis/epidemiology , Drug-Eluting Stents/adverse effects , Europe/epidemiology , Female , Humans , Male , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Registries , Tomography, Optical Coherence/methods
7.
Cardiology ; 137(1): 27-35, 2017.
Article in English | MEDLINE | ID: mdl-27988513

ABSTRACT

OBJECTIVES: To compare angiographic and optical coherence tomography (OCT) data pertinent to thrombi, along with the histologic characteristics of aspirated thrombi in patients presenting with ST elevation myocardial infarction (STEMI) with or without inflammation, as assessed by C-reactive protein (CRP) and myeloperoxidase (MPO). METHODS: In the OCTAVIA (Optical Coherence Tomography Assessment of Gender Diversity in Primary Angioplasty) study, 140 patients with STEMI referred for primary percutaneous intervention were enrolled. The patients underwent OCT assessment of the culprit vessel, along with blood sampling of CRP and MPO, and histologic analysis of the thrombus. RESULTS: Biomarkers were available for 129 patients, and histology and immunohistochemistry of the thrombi were available for 78 patients. Comparisons were made using the median thresholds of CRP and MPO (2.08 mg/L and 604.124 ng/mL, respectively). There was no correlation between CRP and MPO levels in the whole population (p = 0.685). Patients with high CRP levels had higher thrombus grades and more frequent TIMI flow 0/1 compared with those with low CRP levels (5 [1st quartile 3; 3rd quartile 5] vs. 3.5 mg/L [1; 5], p = 0.007, and 69.3 vs. 48.5%, p = 0.04, respectively). Patients with high MPO levels more commonly had early thrombi than had those with low MPO levels (42.5 vs. 20.0%, p = 0.04). CONCLUSIONS: CRP and MPO were not correlated in STEMI patients, possibly reflecting different pathogenic mechanisms, with CRP more related to thrombus burden and MPO to thrombus age.


Subject(s)
C-Reactive Protein/analysis , Coronary Thrombosis/blood , Coronary Thrombosis/diagnostic imaging , Peroxidase/blood , ST Elevation Myocardial Infarction/surgery , Aged , Biomarkers/blood , Coronary Angiography , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention , Prospective Studies , Randomized Controlled Trials as Topic , Risk Factors , ST Elevation Myocardial Infarction/etiology , Tomography, Optical Coherence
9.
EuroIntervention ; 12(7): 855-60, 2016 Sep 18.
Article in English | MEDLINE | ID: mdl-27639737

ABSTRACT

The efficacy of an IVUS-guided stent implantation strategy to improve acute results and clinical outcome has been described previously. OCT is another technique which allows high-resolution intracoronary imaging. However, the use of invasive imaging modalities to guide PCI has, as yet, played a limited role in current clinical practice. This may be partly explained by the expertise required for interpretation and clinical decision making. We present a novel technology which enables real-time co-registration of OCT images with angiography. This will simplify matching cross-sectional images to their geographic position on the angiogram, thereby facilitating imaging-guided PCI.


Subject(s)
Coronary Angiography/methods , Tomography, Optical Coherence/methods , Coronary Angiography/instrumentation , Humans , Percutaneous Coronary Intervention , Tomography, Optical Coherence/instrumentation
10.
Cardiovasc Revasc Med ; 17(5): 339-43, 2016.
Article in English | MEDLINE | ID: mdl-27053437

ABSTRACT

Despite remarkable advances in the interventional landscape, device delivery during percutaneous coronary intervention (PCI) can still present technical challenges especially when performed in complex anatomical settings and through radial approach. To overcome difficult coronary stent delivery, several strategies have been developed. A niche option in such complex cases is the anchoring balloon technique, which involves inflation of a balloon non-coaxially in a side branch or distally to the target lesion in a coaxial fashion, to facilitate stent delivery. However, the main limitation of this technique is the requirement of a large guide catheter (≥7French) which may preclude the use of radial approach. We describe, step-by-step, the distal anchoring ballooning technique performed by a 6Fr radial approach to overcome the stent delivery failure in complex anatomical scenarios and to safely and successfully carry out the PCI procedures.


Subject(s)
Angioplasty, Balloon, Coronary/methods , Cardiac Catheterization/methods , Catheterization, Peripheral/methods , Coronary Artery Disease/therapy , Radial Artery , Aged , Aged, 80 and over , Angioplasty, Balloon, Coronary/instrumentation , Cardiac Catheterization/instrumentation , Cardiac Catheters , Catheterization, Peripheral/instrumentation , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Drug-Eluting Stents , Humans , Male , Punctures , Radial Artery/diagnostic imaging , Treatment Outcome
11.
Circ J ; 80(4): 895-905, 2016.
Article in English | MEDLINE | ID: mdl-26853719

ABSTRACT

BACKGROUND: The role of culprit plaque and related atherothrombotic components on incomplete stent apposition (ISA) occurrence after primary percutaneous coronary intervention (p-PCI) is unknown. METHODS AND RESULTS: ST-segment elevation myocardial infarction (STEMI) patients undergoing p-PCI with an everolimus-eluting stent were prospectively investigated with optical coherence tomography (OCT) of the infarct-related artery before, after stenting and at 9 months. OCT data, aspirated thrombus and serum inflammatory biomarkers were analyzed. 114 patients with 114 lesions were evaluated. Acute ISA occurred in 82 lesions (71.9%), preferentially in larger vessels with a median area of 0.2 mm(2). The presence of thrombus before stent implantation (odds ratio (OR) 5.5, 95% confidence interval (CI) [1.1-26.9], P=0.04) and the lipid content in the target segment (OR 1.3, 95% CI [1.0-1.5], P=0.04) independently predicted acute ISA. At 9-month follow-up, ISA persisted in 46 lesions (56.1%). The volume of acute ISA significantly predicted persistent ISA (OR 1.3, 95% CI [1.1-1.5], P=0.01). Late-acquired ISA occurred in 39 lesions (34.2%) with a median area of 0.3 mm(2). Red/mixed thrombus before stent implantation (OR 3.7, 95% CI [1.0-13.3], P=0.05) and length of the underlying ruptured plaque (OR 1.7, 95% CI [1.1-2.8] P=0.02) were independently associated with late-acquired ISA. CONCLUSIONS: In STEMI patients, culprit plaque and atherothrombotic components of the infarct-related artery significantly contribute to the onset of acute and late ISA. ISA persistence at follow-up depends on the initial volume of acute ISA.


Subject(s)
Drug-Eluting Stents , Everolimus , Myocardial Infarction/surgery , Percutaneous Coronary Intervention , Plaque, Atherosclerotic/surgery , Thrombosis/surgery , Aged , Female , Humans , Male , Middle Aged
12.
J Cardiovasc Med (Hagerstown) ; 17 Suppl 2: e205-e207, 2016 Dec.
Article in English | MEDLINE | ID: mdl-25004000

ABSTRACT

: Angiographic diagnosis and treatment of spontaneous coronary artery dissection is challenging. Complementary use of intracoronary imaging can provide information to guide percutaneous treatments, particularly in these challenging settings. Here we report a case of a 52-year-old woman presenting with an anterior ST-segment elevation myocardial infarction caused by a spontaneous, long, and spiral dissection of the left anterior descending artery. Intracoronary imaging allowed us to visualize the entry port of the coronary dissection which was not sealed by the first angio-guided stenting. This case demonstrates that, beyond merely diagnostic information, the intracoronary imaging is able to provide information to guide percutaneous treatments, particularly in challenging settings in which coronary angiography reveals its limitations.


Subject(s)
Coronary Angiography , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessel Anomalies/therapy , Coronary Vessels/diagnostic imaging , Percutaneous Coronary Intervention , Ultrasonography, Interventional , Vascular Diseases/congenital , Anterior Wall Myocardial Infarction/diagnostic imaging , Anterior Wall Myocardial Infarction/etiology , Coronary Vessel Anomalies/complications , Drug-Eluting Stents , Female , Humans , Middle Aged , Percutaneous Coronary Intervention/instrumentation , Predictive Value of Tests , Tomography, Optical Coherence , Treatment Outcome , Vascular Diseases/complications , Vascular Diseases/diagnostic imaging , Vascular Diseases/therapy
14.
Case Rep Cardiol ; 2015: 851624, 2015.
Article in English | MEDLINE | ID: mdl-26064696

ABSTRACT

We report the case of a 51-year-old woman, treated with radiotherapy at the age of two years, for a pulmonary sarcoma. Subsequently she developed severe aortic stenosis and bilateral ostial coronary artery disease, symptomatic for dyspnea (NYHA III functional class). Due to the prohibitive surgical risk, she underwent successful stenting in the right coronary artery and left main ostia with drug eluting stents and, afterwards, transcatheter aortic valve replacement with transfemoral implantation of a 23 mm Edwards SAPIEN XT valve. The percutaneous treatment was successful without complications and the patient is in NYHA II functional class at 2 years' follow-up, fully carrying out normal daily activities.

15.
JACC Cardiovasc Imaging ; 8(5): 566-575, 2015 May.
Article in English | MEDLINE | ID: mdl-25890582

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the pathophysiological features and response to primary percutaneous coronary intervention (PCI) of nonruptured/eroded plaque versus ruptured plaque as a cause of ST-segment elevation myocardial infarction (STEMI). BACKGROUND: Autopsy series identified nonruptured/eroded plaque and ruptured plaque as the principal pathological substrates underlying coronary thrombosis in STEMI. The real incidence of different plaque morphologies, associated biological factors, superimposed thrombus, and their interaction with primary PCI remain largely unknown. METHODS: In a prospective study, 140 patients with STEMI underwent optical coherence tomography of the infarct-related artery (IRA) before PCI, after everolimus-eluting stent implantation and at 9-month follow-up. Histopathology and immunohistochemistry of thrombus aspirates and serum biomarkers were assessed at baseline. RESULTS: Culprit plaque morphology was adjudicated in 97 patients: 32 plaques (33.0%) with an intact fibrous cap (IFC), 63 (64.9%) plaques with a ruptured fibrous cap (RFC), and 2 (2.1%) spontaneous dissections. Patients with an IFC and RFC had similar clinical characteristics, and serum inflammatory and platelets biomarkers. An IFC presented more frequently with a patent IRA (56.2% vs. 34.9%; p = 0.047), and had fewer lipid areas (lipid-rich areas: 75.0% vs. 100.0%; p < 0.001) and less residual thrombus before stenting (white thrombus: 0.41 mm(3) vs. 1.52 mm(3); p = 0.001; red thrombus: 0 mm(3) vs. 0.29 mm(3); p = 0.001) with a lower peak of creatine kinase-myocardial band (66.6 IU/l vs. 149.8 IU/l; p = 0.025). At the 9-month optical coherence tomography, IFC and RFC had similar high rates of stent strut coverage (92.5% vs. 91.2%; p = 0.15) and similar percentage of volume obstruction (12.6% vs. 10.2%; p = 0.27). No significant differences in clinical outcomes were observed up to 2 years. CONCLUSIONS: In the present study, an IFC was observed at the culprit lesion site of one-third of STEMIs. IFC, compared with RFC, was associated with higher rates of patent IRA at first angiography, fewer lipid areas, and residual endoluminal thrombus. However, no difference in vascular response to everolimus-eluting stent was observed. (Optical Coherence Tomography Assessment of Gender Diversity in Primary Angioplasty [OCTAVIA]; NCT01377207).


Subject(s)
Coronary Artery Disease/therapy , Coronary Thrombosis/therapy , Coronary Vessels/pathology , Myocardial Infarction/therapy , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Aged , Biomarkers/blood , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/blood , Coronary Artery Disease/complications , Coronary Artery Disease/pathology , Coronary Thrombosis/blood , Coronary Thrombosis/complications , Coronary Thrombosis/pathology , Coronary Vessels/drug effects , Coronary Vessels/metabolism , Drug-Eluting Stents , Everolimus/administration & dosage , Female , Fibrosis , Humans , Immunohistochemistry , Inflammation Mediators/blood , Italy , Male , Middle Aged , Myocardial Infarction/blood , Myocardial Infarction/etiology , Myocardial Infarction/pathology , Percutaneous Coronary Intervention/instrumentation , Prospective Studies , Prosthesis Design , Rupture, Spontaneous , Thrombectomy , Time Factors , Tomography, Optical Coherence , Treatment Outcome
17.
Interv Cardiol Clin ; 4(3): 251-284, 2015 Jul.
Article in English | MEDLINE | ID: mdl-28581944

ABSTRACT

Coronary angiography confirms or excludes coronary artery disease, assesses lesions severity, and helps to decide percutaneous coronary interventions (PCI). Coronary angiography has clear limitations. Intravascular imaging guides PCI. Frequency domain optical coherence tomography (OCT) gained attention for accurate planning and guidance of complex PCI. High-speed OCT image acquisition enables prompt vessel assessment in stable and unstable patients. The high-resolution images provide precise tissue characterization and a reliable quantitative assessment of the coronary pathology. Immediately after stent implantation, OCT allows accurate evaluation of stent expansion and symmetry. Real-time angio-OCT co-registration integrates OCT into the PCI workflow for accurate decision making.

18.
Thromb Haemost ; 113(2): 272-82, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25274620

ABSTRACT

The aim was to investigate the perioperative risk of ischaemic and bleeding events in patients with coronary stents undergoing cardiac and non-cardiac surgery and how these outcomes are affected by the perioperative use of oral antiplatelet therapy. This was a multicentre, retrospective, observational study conducted in patients with coronary stent(s) undergoing cardiac or non-cardiac surgery. The primary efficacy endpoint was the 30-day incidence of major adverse cardiac events (MACE), defined as the composite of cardiac death, myocardial infarction (MI) or stroke. The primary safety endpoint was the 30-day incidence of Bleeding Academic Research Consortium (BARC) bleeding ≥ 2. A total of 666 patients were included. Of these, 371 (55.7 %) discontinued their antiplatelet medication(s) (all or partly) before undergoing surgery. At 30 days, patients with perioperative discontinuation of antiplatelet therapy experienced a significantly higher incidence of MACE (7.5 % vs 0.3 %, p< 0.001), cardiac death (2.7 % vs 0.3 %, p=0.027), and MI (4.0 % vs 0 %, p< 0.001). After adjustment, peri-operative antiplatelet discontinuation was the strongest independent predictor of 30-day MACE (odds ratio [OR]=25.8, confidence interval [CI]=3.37-198, p=0.002). Perioperative aspirin (adjusted OR 0.27, 95 % CI 0.11-0.71, p=0.008) was significantly associated with a lower risk of MACE. The overall incidence of BARC ≥ 2 bleeding events at 30-days was significantly higher in patients who discontinued oral antiplatelet therapy (25.6 % vs 13.9 %, p< 0.001). However, after adjustment, antiplatelet discontinuation was not independently associated with BARC ≥ 2 bleeding. In conclusion antiplatelet discontinuation increases the 30-day risk of MACE, in patients with coronary stents undergoing cardiac and non-cardiac surgery, while not offering significant protection from BARC≥ 2 bleeding.


Subject(s)
Aspirin/therapeutic use , Perioperative Period , Platelet Aggregation Inhibitors/therapeutic use , Administration, Oral , Aged , Angina, Stable/therapy , Aspirin/adverse effects , Body Mass Index , Clopidogrel , Drug-Eluting Stents , Female , Hemorrhage/drug therapy , Humans , Male , Middle Aged , Myocardial Ischemia/therapy , Odds Ratio , Percutaneous Coronary Intervention/methods , Prevalence , Registries , Regression Analysis , Retrospective Studies , Risk Factors , Stents , Ticlopidine/analogs & derivatives , Ticlopidine/therapeutic use , Treatment Outcome
19.
JACC Cardiovasc Interv ; 7(9): 958-68, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25129664

ABSTRACT

OBJECTIVES: This study sought to assess in vivo sex differences in the pathophysiology of ST-segment elevation myocardial infarction (STEMI) and vascular response to primary percutaneous coronary intervention (PCI). BACKGROUND: There is no consensus on whether differences in the pathophysiology of STEMI and response to primary PCI between women and men reflect biological factors as opposed to differences in age. METHODS: In this prospective, multicenter study, 140 age-matched men and women with STEMI undergoing primary PCI with everolimus-eluting stent were investigated with intravascular optical coherence tomography, histopathology-immunohistochemistry of thrombus aspirates, and serum biomarkers. Primary endpoints were the percentages of culprit plaque rupture at baseline and everolimus-eluting stent strut coverage at 9-month follow-up as determined by optical coherence tomography. RESULTS: Men and women had similar rates of plaque rupture (50.0% vs. 48.4%; risk ratio [RR]: 1.03; 95% confidence interval [CI]: 0.73 to 1.47; p = 0.56). Nonruptured/eroded plaques comprised 25% of all cases (p = 0.86 in men vs. women). There were no sex differences in composition of aspirated thrombus and immune and inflammatory serum biomarkers. At 9 months, women had similar strut coverage (90.9% vs. 92.5%; difference in medians: RR: 0.2%; 95% CI: -0.4% to 1.3%; p = 0.89) and amount of in-stent neointimal obstruction (10.3% vs. 10.6%; p = 0.76) as men did. There were no sex differences in clinical outcome either at 30-day or 1-year follow-up. CONCLUSIONS: In patients presenting with STEMI undergoing primary PCI, no differences in culprit plaque morphology and factors associated with coronary thrombosis were observed between age-matched men and women. Women also showed similar vascular healing response to everolimus-eluting stents as men did. (Optical Coherence Tomography Assessment of Gender Diversity In Primary Angioplasty: The OCTAVIA Trial [OCTAVIA]; NCT01377207).


Subject(s)
Coronary Artery Disease/therapy , Coronary Thrombosis/therapy , Health Status Disparities , Myocardial Infarction/therapy , Percutaneous Coronary Intervention , Aged , Aged, 80 and over , Biomarkers/blood , Cardiovascular Agents/therapeutic use , Chi-Square Distribution , Coronary Angiography , Coronary Artery Disease/complications , Coronary Artery Disease/diagnosis , Coronary Artery Disease/physiopathology , Coronary Restenosis/diagnosis , Coronary Restenosis/etiology , Coronary Thrombosis/complications , Coronary Thrombosis/diagnosis , Coronary Thrombosis/physiopathology , Drug-Eluting Stents , Everolimus , Female , Humans , Male , Middle Aged , Myocardial Infarction/diagnosis , Myocardial Infarction/etiology , Myocardial Infarction/physiopathology , Neointima , Odds Ratio , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Prospective Studies , Risk Factors , Rupture, Spontaneous , Sex Factors , Sirolimus/administration & dosage , Sirolimus/analogs & derivatives , Time Factors , Tomography, Optical Coherence , Treatment Outcome , Wound Healing
SELECTION OF CITATIONS
SEARCH DETAIL
...