Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med ; 78: 109-116, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32956917

ABSTRACT

PURPOSE: In order to introduce the concept of diagnostic reference levels (DRLs) in the national nuclear medicine practice a survey was proposed and completed through all nuclear medicine departments in Croatia. An additional aim was to increase the awareness of importance and full implementation of a comprehensive quality program that includes devices used in the nuclear medicine chain. METHODS: Data were collected for more than 30 nuclear medicine single photon emission procedures. National DRLs (NDRLs) as administered activity and also as administered activity per unit mass were calculated in accordance to International Commission on Radiological Protection (ICRP) recommendations. Additionally, effective doses were estimated using conversion factors published by the ICRP. RESULTS: NDRLs for nuclear medicine single photon emission procedures were proposed. For procedures performed in only one department typical values were presented as reference. Effective doses related to applied radiopharmaceuticals were calculated to estimate radiation risk related to respective nuclear medicine procedure in more detail. CONCLUSION: This work presents results of the first national survey on DRLs of nuclear medicine single photon emission procedures and proposes reliable NDRLs that represent an actual status of nuclear medicine practice in Croatia. Results have motivated departments to introduce and set their own typical values to be used, as one of the tools, for further optimization process. One of the drawbacks of the DRL concept in nuclear medicine is the lack of the image quality parameters involved. For this reason, a quantity that considers both radiation protection and image quality should be introduced.


Subject(s)
Nuclear Medicine , Radiation Protection , Croatia , Diagnostic Reference Levels , Radiation Dosage , Reference Values
2.
Med Dosim ; 38(1): 100-4, 2013.
Article in English | MEDLINE | ID: mdl-23246197

ABSTRACT

Implementation of advanced techniques in clinical practice can greatly improve the outcome of radiation therapy, but it also makes the process much more complex with a lot of room for errors. An important part of the quality assurance program is verification of treatment planning system (TPS). Dosimetric verifications in anthropomorphic phantom were performed in 4 centers where new systems were installed. A total of 14 tests for 2 photon energies and multigrid superposition algorithms were conducted using the CMS XiO TPS. Evaluation criteria as specified in the International Atomic Energy Agency Technical Reports Series (IAEA TRS) 430 were employed. Results of measurements are grouped according to the placement of the measuring point and the beam energy. The majority of differences between calculated and measured doses in the water-equivalent part of the phantom were in tolerance. Significantly more out-of-tolerance values were observed in "nonwater-equivalent" parts of the phantom, especially for higher-energy photon beams. This survey was done as a part of continuous effort to build up awareness of quality assurance/quality control (QA/QC) importance in the Croatian radiotherapy community. Understanding the limitations of different parts of the various systems used in radiation therapy can systematically improve quality as well.


Subject(s)
Quality Assurance, Health Care/standards , Radiation Oncology/standards , Radiotherapy Planning, Computer-Assisted/standards , Croatia , Guideline Adherence , Guidelines as Topic
SELECTION OF CITATIONS
SEARCH DETAIL