Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
1.
JOR Spine ; 7(1): e1313, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38283179

ABSTRACT

Introduction: Therapeutic interventions for intervertebral disc herniation remain scarce due to the inability of endogenous annulus fibrosus (AF) cells to respond to injury and drive tissue regeneration. Unlike other orthopedic tissues, such as cartilage, delivery of exogenous cells to the site of annular injury remains underdeveloped, largely due to a lack of an ideal cell source and the invasive nature of cell isolation. Human induced pluripotent stem cells (iPSCs) can be differentiated to specific cell fates using biochemical factors and are, therefore, an invaluable tool for cell therapy approaches. While differentiation protocols have been developed for cartilage and fibrous connective tissues (e.g., tendon), the signals that regulate the induction and differentiation of human iPSCs toward the AF fate remain unknown. Methods: iPSC-derived sclerotome cells were treated with various combinations of developmental signals including transforming growth factor beta 3 (TGF-ß3), connective tissue growth factor (CTGF), platelet derived growth factor BB (PDGF-BB), insulin-like growth factor 1 (IGF-1), or the Hedgehog pathway activator, Purmorphamine, and gene expression changes in major AF-associated ECM genes were assessed. The top performing combination treatments were further validated by using three distinct iPSC lines and by assessing the production of upregulated ECM proteins of interest. To conduct a broader analysis of the transcriptomic shifts elicited by each factor combination, and to compare genetic profiles of treated cells to mature human AF cells, a 96.96 Fluidigm gene expression array was applied, and principal component analysis was employed to identify the transcriptional signatures of each cell population and treatment group in comparison to native AF cells. Results: TGF-ß3, in combination with PDGF-BB, CTGF, or IGF-1, induced an upregulation of key AF ECM genes in iPSC-derived sclerotome cells. In particular, treatment with a combination of TGF-ß3 with PDGF-BB for 14 days significantly increased gene expression of collagen II and aggrecan and increased protein deposition of collagen I and elastin compared to other treatment groups. Assessment of genes uniquely highly expressed by AF cells or SCL cells, respectively, revealed a shift toward the genetic profile of AF cells with the addition of TGF-ß3 and PDGF-BB for 14 days. Discussion: These findings represent an initial approach to guide human induced pluripotent stem cells toward an AF-like fate for cellular delivery strategies.

2.
Adv Healthc Mater ; : e2303326, 2023 Dec 23.
Article in English | MEDLINE | ID: mdl-38142300

ABSTRACT

Injectable hydrogels offer minimally-invasive treatment options for degenerative disc disease, a prevalent condition affecting millions annually. Many hydrogels explored for intervertebral disc (IVD) repair suffer from weak mechanical integrity, migration issues, and expulsion. To overcome these limitations, an injectable and radiopaque hyaluronic acid granular hydrogel is developed. The granular structure provides easy injectability and low extrusion forces, while the radiopacity enables direct visualization during injection into the disc and non-invasive monitoring after injection. The radiopaque granular hydrogel is injected into rabbit disc explants to investigate restoration of healthy disc mechanics following needle puncture injury ex vivo and then delivered in a minimally-invasive manner into the intradiscal space in a clinically-relevant in vivo large animal goat model of IVD degeneration initiated through degradation by chondroitinase. The radiopaque granular hydrogel successfully halted loss of disc height due to degeneration. Further, the hydrogel not only enhanced proteoglycan content and reduced collagen content in the nucleus pulposus (NP) region compared to degenerative discs, but also helped to maintain the structural integrity of the disc and promote healthy segregation of the NP and annulus fibrosus regions. Overall, this study demonstrates the great potential of an injectable radiopaque granular hydrogel for treatment of degenerative disc disease.

3.
JOR Spine ; 6(4): e1287, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38156057

ABSTRACT

Background: Vertebral endplate sclerosis and facet osteoarthritis have been documented in animals and humans. However, it is unclear how these adjacent pathologies engage in crosstalk with the intervertebral disc. This study sought to elucidate this crosstalk by assessing each compartment individually in response to acute disc injury. Methods: Eleven New Zealand White rabbits underwent annular disc puncture using a 16G or 21G needle. At 4 and 10 weeks, individual compartments of the motion segment were analyzed. Discs underwent T 1 relaxation mapping with MRI contrast agent gadodiamide as well T 2 mapping. Both discs and facets underwent mechanical testing via vertebra-disc-vertebra tension-compression creep testing and indentation testing, respectively. Endplate bone density was quantified via µCT. Discs and facets were sectioned and stained for histology scoring. Results: Intervertebral discs became more degenerative with increasing needle diameter and time post-puncture. Bone density also increased in endplates adjacent to both 21G and 16G punctured discs leading to reduced gadodiamide transport at 10 weeks. The facet joints, however, did not follow this same trend. Facets adjacent to 16G punctured discs were less degenerative than facets adjacent to 21G punctured discs at 10 weeks. 16G facets were more degenerative at 4 weeks than at 10, suggesting the cartilage had recovered. The formation of severe disc osteophytes in 16G punctured discs between 4 and 10 weeks likely offloaded the facet cartilage, leading to the recovery observed. Conclusions: Overall, this study supports that degeneration spans the whole spinal motion segment following disc injury. Vertebral endplate thickening occurred in response to disc injury, which limited the diffusion of small molecules into the disc. This work also suggests that altered disc mechanics can induce facet degeneration, and that extreme bony remodeling adjacent to the disc may promote facet cartilage recovery through offloading of the articular cartilage.

4.
Sci Transl Med ; 15(722): eadf1690, 2023 11 15.
Article in English | MEDLINE | ID: mdl-37967202

ABSTRACT

Conventional microdiscectomy treatment for intervertebral disc herniation alleviates pain but does not repair the annulus fibrosus, resulting in a high incidence of recurrent herniation and persistent dysfunction. The lack of repair and the acute inflammation that arise after injury can further compromise the disc and result in disc-wide degeneration in the long term. To address this clinical need, we developed tension-activated repair patches (TARPs) for annulus fibrosus repair and local delivery of the anti-inflammatory factor anakinra (a recombinant interleukin-1 receptor antagonist). TARPs transmit physiologic strain to mechanically activated microcapsules embedded within the patch, which release encapsulated bioactive molecules in direct response to spinal loading. Mechanically activated microcapsules carrying anakinra were loaded into TARPs, and the effects of TARP-mediated annular repair and anakinra delivery were evaluated in a goat model of annular injury in the cervical spine. TARPs integrated with native tissue and provided structural reinforcement at the injury site that prevented aberrant disc-wide remodeling resulting from detensioning of the annular fibrosus. The delivery of anakinra by TARP implantation increased matrix deposition and retention at the injury site and improved maintenance of disc extracellular matrix. Anakinra delivery additionally attenuated the inflammatory response associated with TARP implantation, decreasing osteolysis in adjacent vertebrae and preserving disc cellularity and matrix organization throughout the annulus fibrosus. These results demonstrate the therapeutic potential of TARPs for the treatment of intervertebral disc herniation.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc Displacement , Intervertebral Disc , Nanofibers , Animals , Intervertebral Disc Displacement/drug therapy , Intervertebral Disc Displacement/surgery , Goats , Capsules , Interleukin 1 Receptor Antagonist Protein/pharmacology , Interleukin 1 Receptor Antagonist Protein/therapeutic use , Intervertebral Disc Degeneration/surgery
5.
Cells Tissues Organs ; 212(5): 383-398, 2023.
Article in English | MEDLINE | ID: mdl-36966531

ABSTRACT

Varying degrees of hydroxyapatite (HA) surface functionalization have been implicated as the primary driver of differential osteogenesis observed in infiltrating cells. The ability to reliably create spatially controlled areas of mineralization in composite engineered tissues is of growing interest in the field, and the use of HA-functionalized biomaterials may provide a robust solution to this challenge. In this study, we successfully fabricated polycaprolactone salt-leached scaffolds with two levels of a biomimetic calcium phosphate coating to examine their effects on MSC osteogenesis. Longer duration coating in simulated body fluid (SBF) led to increased HA crystal nucleation within scaffold interiors as well as more robust HA crystal formation on scaffold surfaces. Ultimately, the increased surface stiffness of scaffolds coated in SBF for 7 days in comparison to scaffolds coated in SBF for 1 day led to more robust osteogenesis of MSCs in vitro without the assistance of osteogenic signaling molecules. This study also demonstrated that the use of SBF-based HA coatings can promote higher levels of osteogenesis in vivo. Finally, when incorporated as the endplate region of a larger tissue-engineered intervertebral disc replacement, HA coating did not induce mineralization in or promote cell migration out of neighboring biomaterials. Overall, these results verified tunable biomimetic HA coatings as a promising biomaterial modification to promote discrete regions of mineralization within composite engineered tissues.


Subject(s)
Biocompatible Materials , Osseointegration , Tissue Engineering/methods , Osteogenesis , Durapatite/chemistry , Tissue Scaffolds/chemistry , Coated Materials, Biocompatible/pharmacology , Coated Materials, Biocompatible/chemistry
6.
J Orthop Res ; 41(3): 674-683, 2023 03.
Article in English | MEDLINE | ID: mdl-35770853

ABSTRACT

The zygapophyseal joints of the spine, also known as the facet joints, are paired diarthrodial joints posterior to the intervertebral disc and neural elements. The pathophysiology of facet osteoarthritis (OA), as well as crosstalk between the disc and facets, remains largely understudied compared to disc degeneration. The purpose of this study was to characterize alterations to human facet cartilage and subchondral bone across a spectrum of degeneration and to investigate correlations between disc and facet degeneration. Human lumbar facet articular surfaces from six independent donors were subject to creep indentation mechanical testing to quantify cartilage mechanical properties, followed by microcomputed tomography (µCT) analyses for subchondral bone morphometry. The degenerative state of each articular surface was assessed via macroscopic scoring and via Osteoarthritis Research Society International histopathology scoring. Our data suggest reduced facet cartilage compressive and tensile moduli and increased permeability with increasing degenerative grade, particularly at the lower levels of the spine. µCT analyses revealed spinal level-dependent alterations to the subchondral bone, with an increase in trabecular bone at the L4-L5 level, but a decrease at the upper levels of the lumbar spine with increasing degenerative grade. Cortical bone volume fraction was generally decreased with increasing degenerative grade across spinal levels. Correlation analysis revealed several associations between quantitative measures of disc degeneration and facet OA. This study showed that alterations in the mechanical properties of facet cartilage and in the structural properties of facet subchondral bone correlated with aspects of disc degeneration and were highly dependent on spinal level.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc , Osteoarthritis , Zygapophyseal Joint , Humans , Intervertebral Disc Degeneration/pathology , X-Ray Microtomography , Lumbar Vertebrae/pathology , Intervertebral Disc/pathology , Osteoarthritis/pathology , Zygapophyseal Joint/pathology
7.
Global Spine J ; 13(7): 1909-1917, 2023 Sep.
Article in English | MEDLINE | ID: mdl-35156878

ABSTRACT

STUDY DESIGN: Retrospective Analysis. BACKGROUND: Venous thromboembolism (VTE) represents a significant cause of morbidity and mortality in major spine surgery. Placement of prophylactic inferior vena cava filters (IVCF) in patients undergoing major spine surgery was previously adopted at our institution. This study reports our experience and compares VTE rates between patients with and without preoperative IVCF placement. METHODS: A Retrospective comparative study was conducted on adult patients who underwent IVCF placement and those who did not prior to their spinal fusion procedure, between 2013 and 2016. Thoracolumbar fusions (anterior and/or posterior) of 7 or more levels, spinal osteotomies, and a minimum of a 3-month follow-up were included. Traumatic, oncologic, and cervical pathology were excluded. Primary outcomes measured included the incidence of overall VTE (DVT/PE), death, IVCF related complications, and IVCF retrieval. RESULTS: 386 patients who underwent major spine surgery, 258 met the eligibility criteria. Of those patients, 105 patients (40.7%) had prophylactic IVCF placement. All patients had postoperative SCDs and chemoprophylaxis. The presence of an IVCF was associated with an increased rate of overall VTE (14.3% vs 6.5%, P ≤ .05) and DVT episodes (8.6% vs 2.6%, P = .04). The rate of PE for the IVCF group and non-IVCF group was 8.6% and 4.6%, respectively, which was not statistically significant (P = .32). The all-cause mortality rate overall of 2.3% was statistically similar between both groups (P = 1.0). The IVCF group had higher rates of hematoma/seroma vs the non-IVCF group (12.4% vs 3.9%, P ≤ .05). 99 IVCFs were retrievable designs, and 85% were successfully retrieved. Overall IVCF-related complication rate was 11%. CONCLUSIONS: No statistical difference in PE or mortality rates existed between the IVCF and the control group. Patients with IVCF placement experienced approximately twice the rate of VTE and three times the rate of DVT compared to those without IVCF. The IVCF-related complication rate was 11%. Based on the results of this study, the authors recommend against the routine use of prophylactic IVCFs in adults undergoing major spine surgery. LEVEL OF EVIDENCE: III.

8.
Clin Sports Med ; 40(3): 555-569, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34051946

ABSTRACT

Although the safety of contact sports has improved over the years, participation in any sport always carries a risk of injury. When cervical or lumbar spine injuries do occur, prompt diagnosis is essential, and athletes must be held out of the sport if indicated to prevent further harm and allow for recovery. This article highlights some of the most common cervical spine pathologies (stinger/burners, strain, stenosis/cord neuropraxia, disc herniation, and fracture/instability) and lumbar spine pathologies (strain, disc degeneration, disc herniation, fracture, spondylolysis/spondylolisthesis, and scoliosis) encountered in sports and reviews the associated return to play guidelines and expectations for each condition.


Subject(s)
Athletic Injuries/diagnosis , Athletic Injuries/therapy , Cervical Vertebrae/injuries , Lumbar Vertebrae/injuries , Return to Sport , Spinal Diseases/diagnosis , Spinal Diseases/therapy , Clinical Decision-Making , Humans
9.
JOR Spine ; 4(1): e1133, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33778407

ABSTRACT

Intervertebral disc (IVD) herniations, caused by annulus fibrosus (AF) tears that enable disc tissue extrusion beyond the disc space, are very prevalent, especially among adults in the third to fifth decade of life. Symptomatic herniations, in which the extruded tissue compresses surrounding nerves, are characterized by back pain, numbness, and tingling and can cause extreme physical disability. Patients whose symptoms persist after nonoperative intervention may undergo surgical removal of the herniated tissue via microdiscectomy surgery. The AF, however, which has a poor endogenous healing ability, is left unrepaired increasing the risk for re-herniation and pre-disposing the IVD to degenerative disc disease. The lack of understanding of the mechanisms involved in native AF repair limits the design of repair systems that overcome the impediments to successful AF restoration. Moreover, the complexity of the AF structure and the challenging anatomy of the repair environment represents a significant challenge for the design of new repair devices. While progress has been made towards the development of an effective AF repair technique, these methods have yet to demonstrate long-term repair and recovery of IVD biomechanics. In this review, the limitations of endogenous AF healing are discussed and key cellular events and factors involved are highlighted to identify potential therapeutic targets that can be integrated into AF repair methods. Clinical repair strategies and their limitations are described to further guide the design of repair approaches that effectively restore native tissue structure and function.

10.
Sci Rep ; 11(1): 5950, 2021 03 15.
Article in English | MEDLINE | ID: mdl-33723274

ABSTRACT

Cells interpret cues from and interact with fibrous microenvironments through the body based on the mechanics and organization of these environments and the phenotypic state of the cell. This in turn regulates mechanoactive pathways, such as the localization of mechanosensitive factors. Here, we leverage the microscale heterogeneity inherent to engineered fiber microenvironments to produce a large morphologic data set, across multiple cells types, while simultaneously measuring mechanobiological response (YAP/TAZ nuclear localization) at the single cell level. This dataset describing a large dynamic range of cell morphologies and responses was coupled with a machine learning approach to predict the mechanobiological state of individual cells from multiple lineages. We also noted that certain cells (e.g., invasive cancer cells) or biochemical perturbations (e.g., modulating contractility) can limit the predictability of cells in a universal context. Leveraging this finding, we developed further models that incorporate biochemical cues for single cell prediction or identify individual cells that do not follow the established rules. The models developed here provide a tool for connecting cell morphology and signaling, incorporating biochemical cues in predictive models, and identifying aberrant cell behavior at the single cell level.


Subject(s)
Cell Physiological Phenomena , Cells/cytology , Cellular Microenvironment , Mechanotransduction, Cellular , Models, Biological , Algorithms , Animals , Cell Line, Tumor , Cell Nucleus , Cells/pathology , Fibroblasts , Humans , Mice , Neural Networks, Computer , Tumor Microenvironment
11.
Tissue Eng Part B Rev ; 27(4): 295-312, 2021 08.
Article in English | MEDLINE | ID: mdl-32907498

ABSTRACT

The intervertebral disc (IVD) is an integral load-bearing tissue that derives its function from its composite structure and extracellular matrix composition. IVD herniations involve the failure of the annulus fibrosus (AF) and the extrusion of the nucleus pulposus beyond the disc boundary. Disc herniations can impinge the neural elements and cause debilitating pain and loss of function, posing a significant burden on individual patients and society as a whole. Patients with persistent symptoms may require surgery; however, surgical intervention fails to repair the ruptured AF and is associated with the risk for reherniation and further disc degeneration. Given the limitations of AF endogenous repair, many attempts have been made toward the development of effective repair approaches that reestablish IVD function. These methods, however, fail to recapitulate the composition and organization of the native AF, ultimately resulting in inferior tissue mechanics and function over time and high rates of reherniation. Harnessing the cellular function of cells (endogenous or exogenous) at the repair site through the provision of cell-instructive cues could enhance AF tissue regeneration and, ultimately, improve healing outcomes. In this study, we review the diverse approaches that have been developed for AF repair and emphasize the potential for mobilizing the appropriate cellular players at the site of injury to improve AF healing. Impact statement Conventional treatments for intervertebral disc herniation fail to repair the annulus fibrosus (AF), increasing the risk for recurrent herniation. The lack of repair devices in the market has spurred the development of regenerative approaches, yet most of these rely on a scarce endogenous cell population to repair large injuries, resulting in inadequate regeneration. This review identifies current and developing strategies for AF repair and highlights the potential for harnessing cellular function to improve AF regeneration. Ideal cell sources, differentiation strategies, and delivery methods are discussed to guide the design of repair systems that leverage specialized cells to achieve superior outcomes.


Subject(s)
Annulus Fibrosus , Intervertebral Disc Degeneration , Intervertebral Disc Displacement , Intervertebral Disc , Humans , Intervertebral Disc Degeneration/surgery , Intervertebral Disc Displacement/surgery , Wound Healing
12.
J Anat ; 238(4): 986-998, 2021 04.
Article in English | MEDLINE | ID: mdl-33205444

ABSTRACT

Intervertebral disc (IVD) degeneration and associated back pain place a significant burden on the population. IVD degeneration is a progressive cascade of cellular, compositional, and structural changes, which results in a loss of disc height, disorganization of extracellular matrix architecture, tears in the annulus fibrosus which may involve herniation of the nucleus pulposus, and remodeling of the bony and cartilaginous endplates (CEP). These changes to the IVD often occur concomitantly, across the entire motion segment from the disc subcomponents to the CEP and vertebral bone, making it difficult to determine the causal initiating factor of degeneration. Furthermore, assessments of the subcomponents of the IVD have been largely qualitative, with most studies focusing on a single attribute, rather than multiple adjacent IVD substructures. The objective of this study was to perform a multiscale and multimodal analysis of human lumbar motion segments across various length scales and degrees of degeneration. We performed multiple assays on every sample and identified several correlations between structural and functional measurements of disc subcomponents. Our results demonstrate that with increasing Pfirrmann grade there is a reduction in disc height and nucleus pulposus T2 relaxation time, in addition to alterations in motion segment macromechanical function, disc matrix composition and cellular morphology. At the cartilage endplate-vertebral bone interface, substantial remodeling was observed coinciding with alterations in micromechanical properties. Finally, we report significant relationships between vertebral bone and nucleus pulposus metrics, as well as between micromechanical properties of the endplate and whole motion segment biomechanical parameters, indicating the importance of studying IVD degeneration as a whole organ.


Subject(s)
Intervertebral Disc Degeneration/physiopathology , Intervertebral Disc/physiopathology , Lumbar Vertebrae/physiopathology , Aged , Aged, 80 and over , Female , Humans , Intervertebral Disc/diagnostic imaging , Intervertebral Disc/pathology , Intervertebral Disc Degeneration/diagnostic imaging , Intervertebral Disc Degeneration/pathology , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/pathology , Male , Middle Aged , X-Ray Microtomography
13.
JOR Spine ; 3(2): e1086, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32613161

ABSTRACT

Tissue-engineered whole disc replacements are an emerging treatment strategy for advanced intervertebral disc degeneration. A challenge facing the translation of tissue-engineered disc replacement to clinical use are the opposing needs of initial immobilization to advantage integration contrasted with physiologic loading and its anabolic effects. Here, we utilize our established rat tail model of tissue engineered disc replacement with external fixation to study the effects of remobilization at two time points postimplantation on engineered disc structure, composition, and function. Our results suggest that the restoration of mechanical loading following immobilization enhanced collagen and proteoglycan content within the nucleus pulposus and annulus fibrosus of the engineered discs, in addition to improving the integration of the endplate region of the construct with native bone. Despite these benefits, angulation of the vertebral bodies at the implanted level occurred following remobilization at both early and late time points, reducing tensile failure properties in the remobilized groups compared to the fixed group. These results demonstrate the necessity of restoring physiologic mechanical loading to engineered disc implants in vivo, and the need to transition toward their evaluation in larger animal models with more human-like anatomy and motion compared to the rat tail.

14.
Acta Biomater ; 114: 53-62, 2020 09 15.
Article in English | MEDLINE | ID: mdl-32505801

ABSTRACT

Low back pain arising from disc degeneration is one of the most common causes of limited function in adults. A number of tissue engineering strategies have been used to develop composite tissue engineered total disc replacements to restore native tissue structure and function. In this study we fabricated a composite engineered disc based on the combination of a porous polycaprolactone (PCL) foam annulus fibrosus (AF) and a hyaluronic acid (HA) hydrogel nucleus pulposus (NP). To evaluate whether native tissue cells or mesenchymal stem cells (MSCs) would perform better, constructs were seeded with native AF/NP cells or with MSCs in the foam and/or gel region. Maturation of these composite engineered discs was evaluated for 9 weeks in vitro culture by biochemical content, histological analysis and mechanical properties. To evaluate the performance of these constructs in the in vivo space, engineered discs were implanted into the caudal spines of athymic rats for 5 weeks. Our findings show that engineered discs comprised of AF/NP cells and MSCs performed similarly and maintained their structure after 5 weeks in vivo. However, for both cell types, loss of proteoglycan was evident in the NP region. These data support the continued development of the more clinically relevant MSCs population for disc replacement applications. STATEMENT OF SIGNIFICANCE: A number of tissue engineering strategies have emerged that are focused on the creation of a composite disc replacement. We fabricated a composite engineered disc based on the combination of a porous foam AF and a HA gel NP. We used these constructs to determine whether the combination of AF/NP cells or MSCs would mature to a greater extent in vitro and which cell type would best retain their phenotype after implantation. Engineered discs comprised of AF/NP cells and MSCs performed similarly, maintaining their structure after 5 weeks in vivo. These data support the successful fabrication and in vivo function of an engineered disc composed of a PCL foam AF and a hydrogel NP using either disc cells or MSCs.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc , Mesenchymal Stem Cells , Total Disc Replacement , Animals , Intervertebral Disc Degeneration/surgery , Rats , Tissue Engineering
15.
Acta Biomater ; 111: 232-241, 2020 07 15.
Article in English | MEDLINE | ID: mdl-32447064

ABSTRACT

Tissue-engineered replacement discs are an area of intense investigation for the treatment of end-stage intervertebral disc (IVD) degeneration. These living implants can integrate into the IVD space and recapitulate native motion segment function. We recently developed a multiphasic tissue-engineered disc-like angle-ply structure (DAPS) that models the micro-architectural and functional features of native tissue. While these implants resulted in functional restoration of the motion segment in rat and caprine models, we also noted deficiencies in cell infiltration and homogeneity of matrix deposition in the electrospun poly(ε-caprolactone) outer region (annulus fibrosus, AF) of the DAPS. To address this limitation, here, we incorporated a sacrificial water-soluble polymer, polyethylene oxide (PEO), as a second fiber fraction within the AF region to increase porosity of the implant. Maturation of these PEO-modified DAPS were evaluated after 5 and 10 weeks of in vitro culture in terms of AF biochemical content, MRI T2 values, overall construct mechanical properties, AF micromechanical properties and cell and matrix distribution. To assess the performance of the PEO-modified DAPS in vivo, precultured constructs were implanted into the rat caudal IVD space for 10 weeks. Results showed that matrix distribution was more homogenous in PCL/PEO DAPS, as evidenced by more robust histological staining, organized collagen deposition and micromechanical properties, compared to standard PCL-only DAPS in vitro. Cell and matrix infiltration were also improved in vivo, but no differences in macromechanical properties and a trend towards improved micromechanical properties were observed. These findings demonstrate that the inclusion of a sacrificial PEO fiber fraction in the DAPS AF region improves cellular colonization, matrix elaboration, and in vitro and in vivo function of an engineered IVD implant. STATEMENT OF SIGNIFICANCE: This work establishes a method for improving cell infiltration and matrix distribution within tissue-engineered dense fibrous scaffolds for intervertebral disc replacement. Tissue-engineered whole disc replacements are an attractive alternative to the current gold standard (mechanical disc arthroplasty or vertebral fusion) for the clinical treatment of patients with advanced disc degeneration.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc , Animals , Goats , Humans , Intervertebral Disc Degeneration/therapy , Rats , Tissue Engineering , Tissue Scaffolds
16.
J Bone Miner Res ; 35(8): 1572-1581, 2020 08.
Article in English | MEDLINE | ID: mdl-32176817

ABSTRACT

The intervertebral disc is the largest avascular structure in the body, and cells within the disc rely on diffusive transport via vasculature located within the vertebral endplate to receive nutrients, eliminate waste products, and maintain disc health. However, the mechanisms by which small molecule transport into the disc occurs in vivo and how these parameters change with disc degeneration remain understudied. Here, we utilize an in vivo rabbit puncture disc degeneration model to study these interactions and provide evidence that remodeling of the endplate adjacent to the disc occurs concomitant with degeneration. Our results identify significant increases in endplate bone volume fraction, increases in microscale stiffness of the soft tissue interfaces between the disc and vertebral bone, and reductions in endplate vascularity and small molecule transport into the disc as a function of degenerative state. A neural network model identified changes in diffusion into the disc as the most significant predictor of disc degeneration. These findings support the critical role of trans-endplate transport in disease progression and will improve patient selection to direct appropriate surgical intervention and inform new therapeutic approaches to improve disc health. © 2020 American Society for Bone and Mineral Research. Published 2020. This article is a U.S. Government work and is in the public domain in the USA.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc , Animals , Biological Transport , Disease Progression , Intervertebral Disc/metabolism , Intervertebral Disc Degeneration/diagnostic imaging , Intervertebral Disc Degeneration/metabolism , Lumbar Vertebrae/metabolism , Rabbits
17.
Instr Course Lect ; 69: 273-288, 2020.
Article in English | MEDLINE | ID: mdl-32017733

ABSTRACT

The frequency of use of "biologics," including platelet-rich plasma (PRP), bone morphogenetic protein (BMP), and stem cell therapies in the treatment of orthopaedic conditions has significantly increased over the past few decades. The use of PRP and stem cells has been proposed for a wide variety of conditions including knee and hip osteoarthritis (OA), tendon strains and tendinopathies, muscle strains, and acute and chronic soft-tissue injuries. It has also been proposed for use in the enhancement of healing during surgical treatments. BMP has seen use in promoting fracture union and spinal fusion and has been researched as an adjunct in other procedures as well. The current state of the literature in the use and support of these biologics is outlined here.


Subject(s)
Bone Morphogenetic Proteins , Platelet-Rich Plasma , Stem Cells , Humans , Soft Tissue Injuries , Tendinopathy
18.
Nat Biomed Eng ; 3(12): 998-1008, 2019 12.
Article in English | MEDLINE | ID: mdl-31611678

ABSTRACT

In fibrous tissues, prestressed boundary constraints at bone interfaces instil residual strain throughout the tissue, even when unloaded. For example, internal swelling pressures in the central nucleus pulposus of the intervertebral disc generate prestrain in the outer annulus fibrosus. With injury and depressurization, these residual strains are lost. Here we show that the loss of residual strains in the intervertebral disc alters the microenvironment and instigates aberrant tissue remodelling and the adoption of atypical cellular phenotypes. By using puncture surgery of the annulus fibrosus in rabbits, ex vivo puncture experiments and electrospun nanofibrous scaffolds recapitulating these evolving boundary constraints, we show that the loss of residual strain promotes short-term apoptosis and the emergence of a fibrotic phenotype. We also show that local fibre organization and cellular contractility mediate this process and that the aberrant cellular changes could be abrogated by targeting the cell-mechanosensing machinery with small molecules. Our findings indicate that injury to dense connective tissues under prestrain alters boundary constraints and residual strain; this leads to aberrant mechanosensing, which in turn promotes disease progression.


Subject(s)
Annulus Fibrosus/metabolism , Intervertebral Disc Degeneration/metabolism , Intervertebral Disc/injuries , Intervertebral Disc/metabolism , Animals , Annulus Fibrosus/diagnostic imaging , Annulus Fibrosus/pathology , Apoptosis , Biomechanical Phenomena , Disease Models, Animal , Intervertebral Disc/diagnostic imaging , Intervertebral Disc/pathology , Phenotype , Rabbits , Stress, Mechanical
19.
Instr Course Lect ; 68: 305-316, 2019.
Article in English | MEDLINE | ID: mdl-32032069

ABSTRACT

Elective lumbar surgery for common degenerative lumbar spine pathology has been consistently demonstrated to have excellent outcomes by multiple validated measures and improves patient quality of life. The rate of complication is low but not unavoidable; there is an increasing recognition of risk factors that can be mitigated to decrease complication rates. When complications occur, prompt recognition and management may minimize deleterious effects on patient outcome. There are considerations for identifying risk factors and, when possible, minimizing them and general strategies for identifying and managing common complications in lumbar spine surgery.


Subject(s)
Lumbar Vertebrae/surgery , Spinal Fusion , Elective Surgical Procedures , Humans , Postoperative Complications , Quality of Life , Registries , Treatment Outcome
20.
Sci Transl Med ; 10(468)2018 11 21.
Article in English | MEDLINE | ID: mdl-30463917

ABSTRACT

Tissue engineering holds great promise for the treatment of advanced intervertebral disc degeneration. However, assessment of in vivo integration and mechanical function of tissue-engineered disc replacements over the long term, in large animal models, will be necessary to advance clinical translation. To that end, we developed tissue-engineered, endplate-modified disc-like angle ply structures (eDAPS) sized for the rat caudal and goat cervical spines that recapitulate the hierarchical structure of the native disc. Here, we demonstrate functional maturation and integration of these eDAPS in a rat caudal disc replacement model, with compressive mechanical properties reaching native values after 20 weeks in vivo and evidence of functional integration under physiological loads. To further this therapy toward clinical translation, we implanted eDAPS sized for the human cervical disc space in a goat cervical disc replacement model. Our results demonstrate maintenance of eDAPS composition and structure up to 8 weeks in vivo in the goat cervical disc space and maturation of compressive mechanical properties to match native levels. These results demonstrate the translational feasibility of disc replacement with a tissue-engineered construct for the treatment of advanced disc degeneration.


Subject(s)
Intervertebral Disc/physiology , Prostheses and Implants , Tissue Engineering/methods , Animals , Biomechanical Phenomena , Goats , Male , Prosthesis Implantation , Rats , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...