J Orthop ; 56: 6-11, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38715987

ABSTRACT

Introduction: Actigraphy is a quantitative means of measuring activity data that has proven viable in post-surgery recovery analysis for arthroplasties in lower extremities, but scant literature has been published on the utilization actigraphy to evaluate shoulder motion and function before and after shoulder arthroplasty. The purpose of this prospective cohort study is to identify if actigraphy can serve as a valid means for objective evaluation of shoulder function and motion before and after shoulder arthroplasty. Secondarily, the data collected by the actigraphy can be analyzed with standard patient-reported outcomes to report correlations between the subjective and objective methods used in this study. Materials and methods: Sixty-four subjects wore an actigraphy device for one day at pre-op, six, twelve and twenty-four weeks. In addition, subjects completed three patient-reported outcome surveys at each time-point. Student t-tests were used to compare percent activity preoperatively with 24-weeks and to compare PROs preoperatively with 24-week results; categorical variables were compared with one-way ANOVAs. Results: All Patient reported outcome scores significantly improved following arthroplasty (p-value<0.001). The percent of physical activity was highly correlated with vector magnitude (p-value<0.001), but neither percent activity or the vector magnitude were correlated with any of the PROs: UCLA Pain p-value = 0.656, SANE p-value = 0.328, UCLA Function p-value = 0.532. Conclusions: Actigraphy results from this study mirror findings in previous literature utilizing the technology in similar manners and demonstrate its potential for motion and function analysis before and after total shoulder arthroplasties. Despite both being suitable methods independently for the evaluation of shoulder function, there was no significant correlation between standard actigraphy measurements and PROs at 24-weeks. Future research to determine clinical utility and an overall broader scope for actigraphy monitoring could benefit from improved technology, such as increased battery life for prolonged durations of data collection during observation periods.

2.
Aerosp Med Hum Perform ; 87(2): 102-7, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26802374

ABSTRACT

INTRODUCTION: Wearable accelerometers have become ubiquitous in the fields of exercise physiology and ambulatory hospital settings. However, these devices have yet to be validated in extreme operational environments. The objective of this study was to correlate the gravitational forces (G forces) detected by wearable accelerometers with the G forces detected by high performance aircraft. METHODS: We compared the in-flight G forces detected by the two commercially available portable accelerometers to the F/A-18 Carrier Aircraft Inertial Navigation System (CAINS-2) during 20 flights performed by the Navy's Flight Demonstration Squadron (Blue Angels). Postflight questionnaires were also used to assess the perception of distractibility during flight. RESULTS: Of the 20 flights analyzed, 10 complete in-flight comparisons were made, accounting for 25,700 s of correlation between the CAINS-2 and the two tested accelerometers. Both accelerometers had strong correlations with that of the F/A-18 Gz axis, averaging r = 0.92 and r = 0.93, respectively, over 10 flights. Comparison of both portable accelerometer's average vector magnitude to each other yielded an average correlation of r = 0.93. Both accelerometers were found to be minimally distracting. DISCUSSION: These results suggest the use of wearable accelerometers is a valid means of detecting G forces during high performance aircraft flight. Future studies using this surrogate method of detecting accelerative forces combined with physiological information may yield valuable in-flight normative data that heretofore has been technically difficult to obtain and hence holds the promise of opening the door for a new golden age of aeromedical research.


Subject(s)
Accelerometry/instrumentation , Aviation , Gravitation , Equipment Design , Humans
SELECTION OF CITATIONS
SEARCH DETAIL