Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 13(1): 18984, 2023 11 03.
Article in English | MEDLINE | ID: mdl-37923796

ABSTRACT

Dental healthcare personnel (DHCP) are subjected to microbe-containing aerosols and splatters in their everyday work. Safer work conditions must be developed to ensure the functioning of the healthcare system. By simulating dental procedures, we aimed to compare the virus-containing aerosol generation of four common dental instruments, and high-volume evacuation (HVE) in their mitigation. Moreover, we combined the detection of infectious viruses with RT-qPCR to form a fuller view of virus-containing aerosol spread in dental procedures. The air-water syringe produced the highest number of aerosols. HVE greatly reduced aerosol concentrations during procedures. The air-water syringe spread infectious virus-containing aerosols throughout the room, while other instruments only did so to close proximity. Additionally, infectious viruses were detected on the face shields of DHCP. Virus genomes were detected throughout the room with all instruments, indicating that more resilient viruses might remain infectious and pose a health hazard. HVE reduced the spread of both infectious viruses and viral genomes, however, it did not fully prevent them. We recommend meticulous use of HVE, a well-fitting mask and face shields in dental procedures. We advise particular caution when operating with the air-water syringe. Due to limited repetitions, this study should be considered a proof-of-concept report.


Subject(s)
Virus Diseases , Humans , Aerosols , Health Personnel , Dentistry , Water
2.
Indoor Air ; 32(11): e13165, 2022 11.
Article in English | MEDLINE | ID: mdl-36437671

ABSTRACT

COVID-19 has highlighted the need for indoor risk-reduction strategies. Our aim is to provide information about the virus dispersion and attempts to reduce the infection risk. Indoor transmission was studied simulating a dining situation in a restaurant. Aerosolized Phi6 viruses were detected with several methods. The aerosol dispersion was modeled by using the Large-Eddy Simulation (LES) technique. Three risk-reduction strategies were studied: (1) augmenting ventilation with air purifiers, (2) spatial partitioning with dividers, and (3) combination of 1 and 2. In all simulations infectious viruses were detected throughout the space proving the existence long-distance aerosol transmission indoors. Experimental cumulative virus numbers and LES dispersion results were qualitatively similar. The LES results were further utilized to derive the evolution of infection probability. Air purifiers augmenting the effective ventilation rate by 65% reduced the spatially averaged infection probability by 30%-32%. This relative reduction manifests with approximately 15 min lag as aerosol dispersion only gradually reaches the purifier units. Both viral findings and LES results confirm that spatial partitioning has a negligible effect on the mean infection-probability indoors, but may affect the local levels adversely. Exploitation of high-resolution LES jointly with microbiological measurements enables an informative interpretation of the experimental results and facilitates a more complete risk assessment.


Subject(s)
Air Pollution, Indoor , COVID-19 , Humans , SARS-CoV-2 , Restaurants , Air Pollution, Indoor/analysis , Respiratory Aerosols and Droplets
3.
Indoor Air ; 32(10): e13118, 2022 10.
Article in English | MEDLINE | ID: mdl-36305066

ABSTRACT

SARS-CoV-2 has been detected both in air and on surfaces, but questions remain about the patient-specific and environmental factors affecting virus transmission. Additionally, more detailed information on viral sampling of the air is needed. This prospective cohort study (N = 56) presents results from 258 air and 252 surface samples from the surroundings of 23 hospitalized and eight home-treated COVID-19 index patients between July 2020 and March 2021 and compares the results between the measured environments and patient factors. Additionally, epidemiological and experimental investigations were performed. The proportions of qRT-PCR-positive air (10.7% hospital/17.6% homes) and surface samples (8.8%/12.9%) showed statistical similarity in hospital and homes. Significant SARS-CoV-2 air contamination was observed in a large (655.25 m3 ) mechanically ventilated (1.67 air changes per hour, 32.4-421 L/s/patient) patient hall even with only two patients present. All positive air samples were obtained in the absence of aerosol-generating procedures. In four cases, positive environmental samples were detected after the patients had developed a neutralizing IgG response. SARS-CoV-2 RNA was detected in the following particle sizes: 0.65-4.7 µm, 7.0-12.0 µm, >10 µm, and <100 µm. Appropriate infection control against airborne and surface transmission routes is needed in both environments, even after antibody production has begun.


Subject(s)
Air Pollution, Indoor , COVID-19 , Humans , SARS-CoV-2 , COVID-19/epidemiology , RNA, Viral , Prospective Studies , Respiratory Aerosols and Droplets
4.
Environ Res ; 214(Pt 2): 113798, 2022 11.
Article in English | MEDLINE | ID: mdl-35810819

ABSTRACT

A coordinated observational and modelling campaign targeting biogenic aerosols in the air was performed during spring 2021 at two locations in Northern Europe: Helsinki (Finland) and Siauliai (Lithuania), approximately 500 km from each other in north-south direction. The campaign started on March 1, 2021 in Siauliai (12 March in Helsinki) and continued till mid-May in Siauliai (end of May in Helsinki), thus recording the transition of the atmospheric biogenic aerosols profile from winter to summer. The observations included a variety of samplers working on different principles. The core of the program was based on 2- and 2.4--hourly sampling in Helsinki and Siauliai, respectively, with sticky slides (Hirst 24-h trap in Helsinki, Rapid-E slides in Siauliai). The slides were subsequently processed extracting the DNA from the collected aerosols, which was further sequenced using the 3-rd generation sequencing technology. The core sampling was accompanied with daily and daytime sampling using standard filter collectors. The hourly aerosol concentrations at the Helsinki monitoring site were obtained with a Poleno flow cytometer, which could recognize some of the aerosol types. The sampling campaign was supported by numerical modelling. For every sample, SILAM model was applied to calculate its footprint and to predict anthropogenic and natural aerosol concentrations, at both observation sites. The first results confirmed the feasibility of the DNA collection by the applied techniques: all but one delivered sufficient amount of DNA for the following analysis, in over 40% of the cases sufficient for direct DNA sequencing without the PCR step. A substantial variability of the DNA yield has been noticed, generally not following the diurnal variations of the total-aerosol concentrations, which themselves showed variability not related to daytime. An expected upward trend of the biological material amount towards summer was observed but the day-to-day variability was large. The campaign DNA analysis produced the first high-resolution dataset of bioaerosol composition in the North-European spring. It also highlighted the deficiency of generic DNA databases in applications to atmospheric biota: about 40% of samples were not identified with standard bioinformatic methods.


Subject(s)
Air Pollutants , Environmental Monitoring , Aerosols/analysis , Air Pollutants/analysis , Atmosphere/analysis , Environmental Monitoring/methods , Europe , Seasons
5.
Acta Anaesthesiol Scand ; 66(4): 463-472, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34951703

ABSTRACT

BACKGROUND: Intubation, laryngoscopy, and extubation are considered highly aerosol-generating procedures, and additional safety protocols are used during COVID-19 pandemic in these procedures. However, previous studies are mainly experimental and have neither analyzed staff exposure to aerosol generation in the real-life operating room environment nor compared the exposure to aerosol concentrations generated during normal patient care. To assess operational staff exposure to potentially infectious particle generation during general anesthesia, we measured particle concentration and size distribution with patients undergoing surgery with Optical Particle Sizer. METHODS: A single-center observative multidisciplinary clinical study in Helsinki University Hospital with 39 adult patients who underwent general anesthesia with tracheal intubation. Mean particle concentrations during different anesthesia procedures were statistically compared with cough control data collected from 37 volunteers to assess the differences in particle generation. RESULTS: This study measured 25 preoxygenations, 30 mask ventilations, 28 intubations, and 24 extubations. The highest total aerosol concentration of 1153 particles (p)/cm³ was observed during mask ventilation. Preoxygenations, mask ventilations, and extubations as well as uncomplicated intubations generated mean aerosol concentrations statistically comparable to coughing. It is noteworthy that difficult intubation generated significantly fewer aerosols than either uncomplicated intubation (p = .007) or coughing (p = 0.006). CONCLUSIONS: Anesthesia induction generates mainly small (<1 µm) aerosol particles. Based on our results, general anesthesia procedures are not highly aerosol-generating compared with coughing. Thus, their definition as high-risk aerosol-generating procedures should be re-evaluated due to comparable exposures during normal patient care. IMPLICATION STATEMENT: The list of aerosol-generating procedures guides the use of protective equipments in hospitals. Intubation is listed as a high-risk aerosol-generating procedure, however, aerosol generation has not been measured thoroughly. We measured aerosol generation during general anesthesia. None of the general anesthesia procedures generated statistically more aerosols than coughing and thus should not be considered as higher risk compared to normal respiratory activities.


Subject(s)
COVID-19 , Cough , Adult , Aerosols , Anesthesia, General , Humans , Pandemics
SELECTION OF CITATIONS
SEARCH DETAIL
...