Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Toxicol Pharmacol ; 57: 181-188, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29278808

ABSTRACT

This study aims to evaluate the potential toxic effects of ZnO nanoparticles on Artemia franciscana nauplii. The ZnO NPs suspension was characterized by TEM, EDS and DLS techniques. Acute toxicity was investigated by exposure of nauplii to concentrations of 1, 5, 7.5, 10, 15, 20, 25 and 30 mg/L of ZnO NPs for 48 h and 96 h. The 96-h EC10 and EC50 values of ZnO NPs were found to be 1.39 mg/L and 4.86 mg/L respectively. The ZnO NPs suspensions did not cause any significant acute toxicity after 48 h of exposure, but the immobilization rate increase significantly compare to control group after 96 h (P < 0.05). The results showed that the uptake, accumulation, and elimination of NPs in nauplii depends on the concentration of NPs and time. The elimination rates of 46.66% and 83.85% were recorded at 1 and 10 mg/L of NPs after 24 h of depuration period, respectively.


Subject(s)
Artemia/drug effects , Nanoparticles , Water Pollutants, Chemical , Zinc Oxide , Animals , Artemia/metabolism , Nanoparticles/toxicity , Toxicity Tests, Acute , Water Pollutants, Chemical/pharmacokinetics , Water Pollutants, Chemical/toxicity , Zinc Oxide/pharmacokinetics , Zinc Oxide/toxicity
2.
Inhal Toxicol ; 28(6): 281-91, 2016.
Article in English | MEDLINE | ID: mdl-27055369

ABSTRACT

Graphenes have emerged as a highly promising, two-dimensional engineered nanomaterial that can possibly substitute carbon nanotubes. They are being explored in numerous R&D and industrial applications in laboratories across the globe, leading to possible human and environmental exposures to them. Yet, there are no published data on graphene exposures in occupational settings and no readily available methods for their detection and quantitation exist. This study investigates for the first time the potential exposure of workers and research personnel to graphenes in two research facilities and evaluates the status of the control measures. One facility manufactures graphene using graphite exfoliation and chemical vapor deposition (CVD), while the other facility grows graphene on a copper plate using CVD, which is then transferred to a polyethylene terephthalate (PET) sheet. Graphene exposures and process emissions were investigated for three tasks - CVD growth, exfoliation, and transfer - using a multi-metric approach, which utilizes several direct reading instruments, integrated sampling, and chemical and morphological analysis. Real-time instruments included a dust monitor, condensation particle counter (CPC), nanoparticle surface area monitor, scanning mobility particle sizer, and an aethalometer. Morphologically, graphenes and other nanostructures released from the work process were investigated using a transmission electron microscope (TEM). Graphenes were quantified in airborne respirable samples as elemental carbon via thermo-optical analysis. The mass concentrations of total suspended particulate at Workplaces A and B were very low, and elemental carbon concentrations were mostly below the detection limit, indicating very low exposure to graphene or any other particles. The real-time monitoring, especially the aethalometer, showed a good response to the released black carbon, providing a signature of the graphene released during the opening of the CVD reactor at Workplace A. The TEM observation of the samples obtained from Workplaces A and B showed graphene-like structures and aggregated/agglomerated carbon structures. Taken together, the current findings on common scenarios (exfoliation, CVD growth, and transfer), while not inclusive of all graphene manufacturing processes, indicate very minimal graphene or particle exposure at facilities manufacturing graphenes with good manufacturing practices.


Subject(s)
Environmental Monitoring/methods , Graphite/analysis , Manufacturing Industry , Nanoparticles , Occupational Exposure , Occupational Health , Workplace , Environmental Monitoring/instrumentation , Graphite/adverse effects , Humans , Microscopy, Electron, Transmission , Occupational Exposure/adverse effects , Particle Size , Risk Assessment
3.
Biomed Res Int ; 2015: 893049, 2015.
Article in English | MEDLINE | ID: mdl-26125025

ABSTRACT

To better understand the potential ecotoxicological impact of silver nanoparticles (AgNPs) and silver nanowires (AgNWs) released into freshwater environments, the toxicities of these nanomaterials were assessed and compared using Organization for Economic Cooperation and Development (OECD) test guidelines, including a "Daphnia sp., acute immobilization test," "Fish, acute toxicity test," and "freshwater alga and cyanobacteria, growth inhibition test." Based on the estimated median lethal/effective concentrations of AgNPs and AgNWs, the susceptibility to the nanomaterials was different among test organisms (daphnia > algae > fish), suggesting that the AgNPs are classified as "category acute 1" for Daphnia magna, "category acute 2" for Oryzias latipes, and "category acute 1" for Raphidocelis subcapitata, while the AgNWs are classified as "category acute 1" for Daphnia magna, "category acute 2" for Oryzias latipes, and "category acute 2" for Raphidocelis subcapitata, according to the GHS (Globally Harmonized System of Classification and Labelling of Chemicals). In conclusion, the present results suggest that more attention should be paid to prevent the accidental or intentional release of silver nanomaterials into freshwater aquatic environments.


Subject(s)
Nanowires/toxicity , Silver Compounds/toxicity , Silver/toxicity , Water Pollutants, Chemical/toxicity , Animals , Daphnia/drug effects , Fresh Water/chemistry , Humans , Lethal Dose 50 , Metal Nanoparticles/toxicity , Toxicity Tests, Acute
4.
Biomed Res Int ; 2015: 323090, 2015.
Article in English | MEDLINE | ID: mdl-25654094

ABSTRACT

While the commercialization of single-walled carbon nanotubes (SWCNTs) is rapidly expanding, the environmental impact of this nanomaterial is not well understood. Therefore, the present study evaluates the acute aquatic toxicity of SWCNTs towards two freshwater microalgae (Raphidocelis subcapitata and Chlorella vulgaris), a microcrustacean (Daphnia magna), and a fish (Oryzias latipes) based on OECD test guidelines (201, 202, and 203). According to the results, the SWCNTs inhibited the growth of the algae R. subcapitata and C. vulgaris with a median effective concentration (EC50) of 29.99 and 30.96 mg/L, respectively, representing "acute category 3" in the Globally Harmonized System (GHS) of classification and labeling of chemicals. Meanwhile, the acute toxicity test using O. latipes and D. magna did not show any mortality/immobilizing effects up to a concentration of 100.00 mg/L SWCNTs, indicating no hazard category in the GHS classification. In conclusion, SWCNTs were found to induce acute ecotoxicity in freshwater microalgae, yet not in D. magna and medaka fish.


Subject(s)
Aquatic Organisms/drug effects , Fresh Water , Nanotubes, Carbon/toxicity , Toxicity Tests, Acute , Animals , Biomass , Daphnia/drug effects , Immobilization , Microalgae/cytology , Microalgae/drug effects , Microalgae/growth & development , Nanotubes, Carbon/ultrastructure , Oryzias/physiology
5.
Inhal Toxicol ; 25(8): 426-34, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23808635

ABSTRACT

Printed electronics uses converging technologies, such as printing, fine mechanics, nanotechnology, electronics and other new technologies. Consequently, printed electronics raises additional health and safety concerns to those experienced in the traditional printing industry. This study investigated two printed electronics workplaces based on a walk-through survey and personal and area sampling. All the printed electronics operations were conducted in a cleanroom. No indication of exposure to excess silver nanoparticles or carbon nanotubes (CNTs) was found. While the organic solvents were lower than current occupational exposure limits, there was a lack of engineering controls, such as local exhaust ventilation, correct enclosure and duct connections. There was also an insufficient quantity of personal protective equipment, and some organic solvents not described in the safety data sheets (SDSs) were detected in the air samples. Plus, the cleaning work, a major emissions operation, was not conducted within a hood, and the cleaning waste was not properly disposed of. Therefore, the present exposure assessment results from two printed electronics workplaces suggest that the printed electronics industry needs to take note of the occupational safety and health risks and hazards already established by the traditional printing industry, along with new risks and hazards originating from converging technologies such as nanotechnology.


Subject(s)
Air Pollutants, Occupational/analysis , Electronics , Inhalation Exposure/analysis , Occupational Exposure/analysis , Printing , Environmental Monitoring , Humans , Nanoparticles/analysis , Particulate Matter/analysis , Protective Devices , Silver/analysis , Solvents/analysis , Workplace
SELECTION OF CITATIONS
SEARCH DETAIL
...