Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 191
Filter
1.
Eur Heart J ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38740526

ABSTRACT

BACKGROUND AND AIMS: Arrhythmic mitral valve prolapse (AMVP) is linked to life-threatening ventricular arrhythmias (VAs), and young women are considered at high risk. Cases of AMVP in women with malignant VA during pregnancy have emerged, but the arrhythmic risk during pregnancy is unknown. The authors aimed to describe features of women with high-risk AMVP who developed malignant VA during the perinatal period and to assess if pregnancy and the postpartum period were associated with a higher risk of malignant VA. METHODS: This retrospective international multi-centre case series included high-risk women with AMVP who experienced malignant VA and at least one pregnancy. Malignant VA included ventricular fibrillation, sustained ventricular tachycardia, or appropriate shock from an implantable cardioverter defibrillator. The authors compared the incidence of malignant VA in non-pregnant periods and perinatal period; the latter defined as occurring during pregnancy and within 6 months after delivery. RESULTS: The authors included 18 women with AMVP from 11 centres. During 7.5 (interquartile range 5.8-16.6) years of follow-up, 37 malignant VAs occurred, of which 18 were pregnancy related occurring in 13 (72%) unique patients. Pregnancy and 6 months after delivery showed increased incidence rate of malignant VA compared to the non-pregnancy period (univariate incidence rate ratio 2.66, 95% confidence interval 1.23-5.76). CONCLUSIONS: The perinatal period could impose increased risk of malignant VA in women with high-risk AMVP. The data may provide general guidance for pre-conception counselling and for nuanced shared decision-making between patients and clinicians.

3.
Clin Res Cardiol ; 2024 May 02.
Article in English | MEDLINE | ID: mdl-38695900

ABSTRACT

BACKGROUND: Permanent pacemaker implantation (PMI) is associated with increased morbidity after transcatheter aortic valve replacement (TAVR). Cardiac resynchronization-therapy (CRT) is recommended for patients if left ventricular ejection fraction (LVEF) is ≤ 40% and ventricular pacing is expected in favor to sole right ventricular (RV) pacing. Meanwhile, LVEF may recover after TAVR in patients with aortic valve disease and the benefit of CRT is unknown. OBJECTIVE: To analyze the impact of CRT implantation as compared to RV pacing after TAVR. METHODS AND RESULTS: Between 2012 and 2022, 4385 patients (53.1% female, mean age 81 ± 6 years) without prior PMI undergoing TAVR were retrospectively identified in our institutional registry. After stratification of patients in LVEF ≤ 40%, 41-49% and ≥ 50%, Kaplan-Meier analysis revealed significantly different survival rates in each subgroup at 5 years (37.0% vs. 43.5% vs. 55.1%; P ≤ 0.021). At multivariate regression, LVEF and new PMI after TAVR were not relevant for survival. A total of 105 patients with LVEF ≤ 40% received PMI after TAVR (86 patients with RV pacing and 19 with CRT). At 5 years, all-cause mortality was significantly lower in patients with CRT-device as compared to patients without CRT-device (Kaplan Meier estimate of 21.1% vs. 48.8%; HR 0.48, CI 0.204 - 1.128; log rank p = 0.045). In multivariate analysis CRT remained a significant factor for 5-year survival in these patients (HR 0.3, CI 0.095-0.951, p = 0.041). CONCLUSION: In patients undergoing TAVR, PMI did not influence 5-year survival. In patients with LVEF ≤ 40%, CRT-device implantation was associated with improved survival compared to non-CRT-device implantation.

4.
Article in English | MEDLINE | ID: mdl-38632135

ABSTRACT

BACKGROUND: Pulmonary vein (PV) occlusion is crucial for adequate lesion formation during cryoballoon-guided pulmonary vein isolation (CB-PVI). PV occlusion is usually confirmed by angiographies over the inflated balloon device. The aim of our study was to analyze the safety and efficacy of pressure waveform-based PV occlusion assessment during CB-PVI utilizing a novel fully integrated pressure analysis tool. METHODS: Consecutive patients with symptomatic atrial fibrillation (AF) scheduled for CB-PVI were prospectively enrolled for pressure waveform-based PV occlusion assessment. A patient cohort receiving conventional angiographies served as control group. Patients with common PV ostia were excluded. RESULTS: The study group consisted of 40 patients (16 females, mean age was 64.5 ± 9.7, 45% persistent AF). The control group consisted of 40 matched patients. All 160 PVs in the study group were successfully isolated without the use of additional venograms confirming PV occlusion. The mean procedure duration was 69 ± 12 min in the study group with a mean fluoroscopy duration of 11.5 ± 4.4 min. The mean contrast medium volume was 22 ± 9 ml in the study group and 36 ± 12 ml in the control group (p = 0.0001). Mean procedure duration, mean balloon temperatures, and mean ablation application durations did not differ significantly between the study and the control group. No periprocedural complications occurred. CONCLUSION: CB-PVI utilizing a fully integrated pressure waveform analysis tool to assess PV occlusion is feasible and safe and significantly reduces the amount of contrast medium without impact on procedural parameters and freedom from arrhythmia recurrence.

5.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38591838

ABSTRACT

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Stroke/etiology , Stroke/prevention & control , Risk , Hemorrhage , Anticoagulants/therapeutic use
7.
J Clin Med ; 13(7)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38610811

ABSTRACT

In recent decades, diagnosing, risk-stratifying, and treating patients with primary electrical diseases, as well as heart rhythm disorders, have improved substantially [...].

8.
Heart Rhythm ; 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38604590

ABSTRACT

BACKGROUND: The CASTLE-HTx trial demonstrated the benefit of atrial fibrillation (AF) ablation compared with medical therapy in decreasing mortality, need for left ventricular assist device implantation, or heart transplantation (HTx) in patients with end-stage heart failure (HF). OBJECTIVE: This analysis aimed to identify risk factors related to adverse outcomes in patients with end-stage HF and to assess the impact of ablation. METHODS: The CASTLE-HTx protocol randomized 194 patients with end-stage HF and AF to ablation vs medical therapy. We identified left ventricular ejection fraction <30%, New York Heart Association class ≥III, and AF burden >50% as predictors for the primary end point. The CASTLE-HTx risk score assigned weights to these risk factors. Patients with a risk score ≥3 were identified as high risk. RESULTS: The patients were assigned to low-risk (89 [45.9%]) and high-risk (105 [54.1%]) groups. After a median follow-up of 18 months, a primary end point event occurred in 6 and 31 patients of the low- and high-risk groups (hazard ratio, 4.98; 95% confidence interval, 2.08-11.9). The incidence rate (IR) difference between ablation and medical therapy was much larger in high-risk patients (8/49 [IR, 11.4] vs 23/56 [IR, 36.1]) compared with low-risk patients (2/48 [IR, 2.6] vs 4/41 [IR, 6.3]). The IR difference for ablation was significantly higher in high-risk patients (24.69) compared with low-risk patients (3.70). CONCLUSION: The absolute benefit of ablation is more pronounced in high-risk patients, but low-risk patients may also benefit. The CASTLE-HTx risk score identifies patients with end-stage HF who will particularly benefit from ablation.

9.
Article in English | MEDLINE | ID: mdl-38483417

ABSTRACT

BACKGROUND: Arrhythmia-induced cardiomyopathy (AIC) is a known entity, but prospective evidence for its characterization is limited. OBJECTIVES: This study aimed to: 1) determine the relative frequency of the pure form of AIC in the clinically relevant cohort of patients with newly diagnosed, otherwise unexplained left ventricular systolic dysfunction (LVSD) and tachyarrhythmia; 2) assess the time to recovery from LVSD; and 3) identify parameters for an early diagnosis of AIC. METHODS: Patients were prospectively included, underwent effective rhythm restoration, and were followed-up at 2, 4, and 6 months to evaluate clinical characteristics, biomarkers, and cardiac imaging including cardiac magnetic resonance imaging. Patients with recurred arrhythmia were excluded from analysis. RESULTS: 41 of 50 patients were diagnosed with AIC 6 months after rhythm restoration. Left ventricular (LV) ejection fraction increased 2 months after rhythm restoration from 35.4% ± 8.2% to 52.7% ± 8.0% in AIC patients vs 37.0% ± 9.5% to 43.3% ± 7.0% in non-AIC patients. From month 2 to 6, LV ejection fraction continued to increase in AIC patients (57.2% ± 6.1%; P < 0.001) but remained stable in non-AIC patients (44.0% ± 7.8%; P = 0.628). Multivariable logistic regression analysis revealed that lower LV end-diastolic diameter at baseline could be used for early diagnosis of AIC, whereas biomarkers and other morphological or functional parameters, including late LV gadolinium enhancement, did not show suitability for early diagnosis. CONCLUSIONS: We observed a high prevalence of AIC in patients with otherwise unexplained LVSD and concomitant tachyarrhythmia, suggesting that this condition may be underdiagnosed in clinical practice. Most patients recovered fast, within months, from LVSD. A low initial LV end-diastolic diameter may constitute an early marker for diagnosis of AIC.

10.
Europace ; 26(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38516791

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) for catheter ablation of atrial fibrillation (AF) is a time-demanding procedure. High-power short-duration (HPSD) ablation protocols and high-density mapping catheters have recently been introduced to clinical practice. We investigated the impact of high-density mapping and HPSD ablation protocols on procedural timing, efficacy, and safety by comparing different standardized set-ups. METHODS AND RESULTS: Three electrophysiology (EP) laboratory set-ups were analysed: (i) circular catheter for mapping and HPSD ablation with 30/35 W guided by an ablation index (AI); (ii) pentaspline catheter for mapping an HPSD ablation with 50 W guided by an AI; and (iii) pentaspline catheter for mapping and HPSD ablation with 90 W over 4 s using a novel ablation catheter. All patients underwent PVI without additional left atrial ablation strategies. Procedural data and operating intervals in the EP laboratory were systematically analysed. Three hundred seven patients were analysed (30/35 W AI: n = 102, 50 W AI: n = 102, 90 W/4 s: n = 103). Skin-to-skin times [105.3 ± 22.7 (30/35 W AI) vs. 81.4 ± 21.3 (50 W AI) vs. 69.5 ± 12.2 (90 W/4 s) min, P ≤ 0.001] and total laboratory times (132.8 ± 42.1 vs. 107.4 ± 25.7 vs. 95.2 ± 14.0 min, P < 0.001) significantly differed among the study groups. Laboratory interval analysis revealed significant shortening of mapping and ablation times. Arrhythmia-free survival after 12 months was not different among the study groups (log-rank P = 0.96). CONCLUSION: The integration of high-density mapping and HPSD protocols into an institutional AF ablation process resulted in reduced procedure times without compromising safety or efficacy.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Workflow , Heart Atria , Catheter Ablation/adverse effects , Pulmonary Veins/surgery , Treatment Outcome , Recurrence
13.
Pacing Clin Electrophysiol ; 47(1): 88-100, 2024 01.
Article in English | MEDLINE | ID: mdl-38071456

ABSTRACT

Atrial fibrillation (AF) and heart failure are common overlapping cardiovascular disorders. Despite important therapeutic advances over the past several decades, controversy persists about whether a rate control or rhythm control approach constitutes the best option in this population. There is also considerable debate about whether antiarrhythmic drug therapy or ablation is the best approach when rhythm control is pursued.  A brief historical examination of the literature addressing this issue will be performed. An analysis of several important clinical outcomes observed in the prospective, randomized studies, which have compared AF ablation to non-ablation treatment options, will be discussed. This review will conclude with recommendations to guide clinicians on the status of AF ablation as a treatment option when considering management options in heart failure patients with atrial fibrillation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Humans , Prospective Studies , Anti-Arrhythmia Agents/therapeutic use , Heart Failure/therapy , Patients , Treatment Outcome
15.
Pacing Clin Electrophysiol ; 46(12): 1586-1594, 2023 12.
Article in English | MEDLINE | ID: mdl-37943015

ABSTRACT

Pulsed field ablation (PFA) is a promising technology for the treatment of atrial fibrillation (AF). Due to its unique tissue selectivity, PFA potentially bears superior characteristics as compared to established thermal energy sources in AF ablation procedures. Cardiovascular magnetic resonance imaging (CMR) using late gadolinium enhancement (LGE) is an established tool in the analysis of myocardial fibrosis representing atrial cardiomyopathy as well as ablation-induced atrial scar formation following catheter ablation with thermal energy. Mechanisms of atrial lesion formation differ between thermal ablation and electroporation and its impact on results of CMR imaging are not fully understood until now. In this review article, the potential of CMR imaging for PFA lesion assessment and available data are discussed. Further, additional needs to adopt imaging approaches to the cellular mechanisms of electroporation are considered.


Subject(s)
Atrial Fibrillation , Cardiomyopathies , Catheter Ablation , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Contrast Media , Gadolinium , Magnetic Resonance Imaging/methods , Heart Atria/diagnostic imaging , Heart Atria/surgery , Heart Atria/pathology , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/surgery , Catheter Ablation/methods
16.
Pacing Clin Electrophysiol ; 46(12): 1553-1564, 2023 12.
Article in English | MEDLINE | ID: mdl-37885302

ABSTRACT

BACKGROUND: Targeting individual sources identified during atrial fibrillation (AF) has been used as an ablation strategy with varying results. OBJECTIVE: Aim of this study was to evaluate the relationship between regions of interest (ROIs) from CARTOFINDER (CF) mapping and atrial cardiomyopathy from late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR). METHODS: Twenty consecutive patients underwent index catheter ablation for persistent AF (PERS AF). Pre-processed LGE CMR images were merged with the results from CF mapping to visualize harboring regions for focal and rotational activities. Atrial cardiomyopathy was classified based on the four Utah stages. RESULTS: Procedural success was achieved in all patients (n = 20, 100%). LGE CMR revealed an intermediate amount of 21.41% ± 6.32% for LA fibrosis. ROIs were identified in all patients (mean no ROIs per patient n = 416.45 ± 204.57). A tendency towards a positive correlation between the total amount of atrial cardiomyopathy and the total number of ROIs per patient (regression coefficient, ß = 10.86, p = .15) was observed. The degree of fibrosis and the presence of ROIs per segment showed no consistent spatial correlation (posterior: ß = 0.36, p-value (p) = .24; anterior: ß = -0.08, p = .54; lateral: ß = 0.31, p = 39; septal: ß = -0.12; p = .66; right PVs: ß = 0.34, p = .27; left PVs: ß = 0.07, p = .79; LAA: ß = -0.91, p = .12). 12 months AF-free survival was 70% (n = 14) after ablation. CONCLUSION: The presence of ROIs from CF mapping was not directly associated with the extent and location of fibrosis. Further studies evaluating the relationship between focal and rotational activity and atrial cardiomyopathy are mandatory.


Subject(s)
Atrial Fibrillation , Cardiomyopathies , Catheter Ablation , Humans , Catheter Ablation/methods , Contrast Media , Fibrosis , Gadolinium , Heart Atria , Magnetic Resonance Imaging/methods
17.
Balkan Med J ; 40(6): 386-394, 2023 10 20.
Article in English | MEDLINE | ID: mdl-37817408

ABSTRACT

Catheter ablation has emerged as an effective treatment for atrial arrhythmias, and pulmonary vein isolation (PVI) is the cornerstone of ablation strategies. Significant technological evolution and widespread increase in operator experience have facilitated the effectiveness of catheter ablation to achieve durable PVIs in single or multiple ablation procedures. Nevertheless, arrhythmia recurrence is a common problem even after establishing PVI. Data on catheter ablation in these patients are sparse and repeat ablation in this population is highly challenging. In this review we have summarized the available data as well as potential strategies of catheter ablation following the initial PVI.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Treatment Outcome , Catheter Ablation/methods , Recurrence
19.
N Engl J Med ; 389(15): 1380-1389, 2023 Oct 12.
Article in English | MEDLINE | ID: mdl-37634135

ABSTRACT

BACKGROUND: The role of catheter ablation in patients with symptomatic atrial fibrillation and end-stage heart failure is unknown. METHODS: We conducted a single-center, open-label trial in Germany that involved patients with symptomatic atrial fibrillation and end-stage heart failure who were referred for heart transplantation evaluation. Patients were assigned to receive catheter ablation and guideline-directed medical therapy or medical therapy alone. The primary end point was a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation. RESULTS: A total of 97 patients were assigned to the ablation group and 97 to the medical-therapy group. The trial was stopped for efficacy by the data and safety monitoring board 1 year after randomization was completed. Catheter ablation was performed in 81 of 97 patients (84%) in the ablation group and in 16 of 97 patients (16%) in the medical-therapy group. After a median follow-up of 18.0 months (interquartile range, 14.6 to 22.6), a primary end-point event had occurred in 8 patients (8%) in the ablation group and in 29 patients (30%) in the medical-therapy group (hazard ratio, 0.24; 95% confidence interval [CI], 0.11 to 0.52; P<0.001). Death from any cause occurred in 6 patients (6%) in the ablation group and in 19 patients (20%) in the medical-therapy group (hazard ratio, 0.29; 95% CI, 0.12 to 0.72). Procedure-related complications occurred in 3 patients in the ablation group and in 1 patient in the medical-therapy group. CONCLUSIONS: Among patients with atrial fibrillation and end-stage heart failure, the combination of catheter ablation and guideline-directed medical therapy was associated with a lower likelihood of a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation than medical therapy alone. (Funded by Else Kröner-Fresenius-Stiftung; CASTLE-HTx ClinicalTrials.gov number, NCT04649801.).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Humans , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Germany , Heart Failure/complications , Heart Failure/surgery , Heart Transplantation , Heart-Assist Devices , Referral and Consultation , Treatment Outcome
20.
Diagnostics (Basel) ; 13(14)2023 Jul 20.
Article in English | MEDLINE | ID: mdl-37510168

ABSTRACT

BACKGROUND: Hindered by its unspecific clinical and phenotypical presentation, cardiac sarcoidosis (CS) remains a challenging diagnosis. OBJECTIVE: Utilizing cardiac magnetic resonance imaging (CMR), we acquired multi-chamber volumetrics and strain feature tracking for a support vector machine learning (SVM)-based diagnostic approach to CS. METHOD: Forty-five CMR-negative (CMR(-), 56.5(53.0;63.0)years), eighteen CMR-positive (CMR(+), 64.0(57.8;67.0)years) sarcoidosis patients and forty-four controls (CTRL, 56.5(53.0;63.0)years)) underwent CMR examination. Cardiac parameters were processed using the classifiers of logistic regression, KNN(K-nearest-neighbor), DT (decision tree), RF (random forest), SVM, GBoost, XGBoost, Voting and feature selection. RESULTS: In a three-cluster analysis of CTRL versus vs. CMR(+) vs. CMR(-), RF and Voting classifier yielded the highest prediction rates (81.82%). The two-cluster analysis of CTRL vs. all sarcoidosis (All Sarc.) yielded high prediction rates with the classifiers logistic regression, RF and SVM (96.97%), and low prediction rates for the analysis of CMR(+) vs. CMR(-), which were augmented using feature selection with logistic regression (89.47%). CONCLUSION: Multi-chamber cardiac function and strain-based supervised machine learning provides a non-contrast approach to accurately differentiate between healthy individuals and sarcoidosis patients. Feature selection overcomes the algorithmically challenging discrimination between CMR(+) and CMR(-) patients, yielding high accuracy predictions. The study findings imply higher prevalence of cardiac involvement than previously anticipated, which may impact clinical disease management.

SELECTION OF CITATIONS
SEARCH DETAIL
...