Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 13(1): 6697, 2023 04 24.
Article in English | MEDLINE | ID: mdl-37095093

ABSTRACT

Ventricular septal defects (VSD) are the most common congenital heart diseases in children. Among them, perimembranous VSD (pm-VSD) have a higher risk of complications, including aortic valve prolapse and aortic regurgitation (AR). The aim of our study was to assess echocardiographic criteria associated with AR during follow-up of pm-VSD. Forty children with restrictive pm-VSD, followed-up in our unit and who underwent a workable echocardiographic evaluation between 2015 and 2019 were included and retrospectively analyzed. The propensity score was used to match 15 patients with AR to 15 patients without AR. Median age was 2.2 year [1.4-5.7]. Median weight was 14 kg [9.9-20.3]. Aortic annulus z-score, Valsalva sinus z-score, sinotubular junction z-score, valve prolapse and commissure commitment were significantly different between the two groups (p = 0.047, p = 0.001, p = 0.010, p = 0.007, p < 0.001 respectively). Aortic root dilatation, aortic valve prolapse and commissure commitment to a perimembranous VSD are associated to aortic regurgitation.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Prolapse , Heart Septal Defects, Ventricular , Humans , Child , Child, Preschool , Aortic Valve Prolapse/complications , Retrospective Studies , Heart Septal Defects, Ventricular/epidemiology , Echocardiography/adverse effects
2.
Ann Thorac Surg ; 115(6): 1446-1454, 2023 06.
Article in English | MEDLINE | ID: mdl-35952857

ABSTRACT

BACKGROUND: We evaluated the incidence, prognosis, and predictive factors of new onset of persistent left bundle branch block (NOP-LBBB) after rapid-deployment aortic valve replacement (RD-AVR). METHODS: This was an observational, retrospective, single-center study of 274 consecutive patients with no baseline ventricular conduction disorder and no previous permanent pacemaker implantation (PPI) who underwent RD-AVR with an INTUITY valve (n = 55) or INTUITY Elite Valve (n = 219) (Edwards Lifesciences). Transthoracic echocardiography and 12-lead electrocardiography was performed preoperatively, at discharge, and at 1-month and 1-year intervals. The incidence, prognosis, and predictive factors of NOP-LBBB were evaluated. RESULTS: NOP-LBBB occurred in 58 patients (21.2%) after discharge. In multivariate analysis, age (P < .01), INTUITY valve diameter ≥23 mm (P = .02), and INTUITY Elite implantation (P = .01) were independent predictors of NOP-LBBB. By 1:1 propensity matching analysis between the NOP-LBBB group and the control group, there were no significant differences in 1-year overall mortality (P = .23), hospitalization for congestive heart failure (P = .99), or PPI (P = .99). NOP-LBBB exposed patients to a high rate of dysrhythmic events (12.1% vs 1.4%, P < .01) and was associated with a significant decrease in left ventricular ejection fraction (0.62 ± 0.095 vs 0.652 ± 0.0783, P = .02) without an impact on New York Heart Association functional status (1.25 ± 0.32 and 1.52 ± 0.70, P = .32). PPI was performed in 17 patients (6.2%) before discharge, including 14 NOP-LBBB patients. CONCLUSIONS: NOP-LBBB after RD-AVR is prevalent in patients with no prior conduction disorders. INTUITY Elite is associated with a significantly higher rate of NOP-LBBB. The persistence of NOP-LBBB predisposed patients to the occurrence of high-grade conduction disorders and might have led to PPI but did not increase death or hospitalization for congestive heart failure.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Bundle-Branch Block/diagnosis , Bundle-Branch Block/epidemiology , Bundle-Branch Block/etiology , Stroke Volume , Transcatheter Aortic Valve Replacement/adverse effects , Retrospective Studies , Treatment Outcome , Incidence , Aortic Valve Stenosis/surgery , Ventricular Function, Left , Heart Valve Prosthesis/adverse effects , Electrocardiography , Heart Failure/surgery , Pacemaker, Artificial/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...