Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
World J Gastroenterol ; 27(21): 2910-2920, 2021 Jun 07.
Article in English | MEDLINE | ID: mdl-34135561

ABSTRACT

BACKGROUND: Persistent liver inflammatory damage is the main risk factor for developing liver fibrosis, cirrhosis, and even hepatocellular carcinoma in chronic hepatitis B (CHB) patients. Thus, accurate prediction of the degree of liver inflammation is a high priority and a growing medical need. AIM: To build an effective and robust non-invasive model for predicting hepatitis B-related hepatic inflammation. METHODS: A total of 650 treatment-naïve CHB (402 HBeAg-positive and 248 HBeAg-negative) patients who underwent liver biopsy were enrolled in this study. Histological inflammation grading was assessed by the Ishak scoring system. Serum quantitative hepatitis B core antibody (qAnti-HBc) levels and 21 immune-related inflammatory factors were measured quantitatively using a chemiluminescent microparticle immunoassay. A backward feature elimination (BFE) algorithm utilizing random forest (RF) was used to select optional features and construct a combined model. The diagnostic abilities of the model or variables were evaluated based on the estimated area under the receiver operating characteristics curve (AUROC) and compared using the DeLong test. RESULTS: Four features were selected to predict moderate-to-severe inflammation in CHB patients using the RF-BFE method. These predictive features included qAnti-HBc, ALT, AST, and CXCL11. Spearman's correlation analysis indicated that serum qAnti-HBc, ALT, AST, and CXCL11 levels were positively correlated with the histology activity index (HAI) score. These selected features were incorporated into the model to establish a novel model named I-3A index. The AUROC [0.822; 95% confidence interval (CI): 0.790-0.851] of the I-3A index was significantly increased compared with qAnti-HBc alone (0.760, 95%CI: 0.724-0.792, P < 0.0001) in all CHB patients. The use of an I-3A index cutoff value of 0.41 produced a sensitivity of 69.17%, specificity of 81.44%, and accuracy of 73.8%. Additionally, the I-3A index showed significantly improved diagnostic performance for predicting moderate-to-severe inflammation in HBeAg-positive and HBeAg-negative CHB patients (0.829, 95%CI: 0.789-0.865 and 0.810, 95%CI: 0.755-0.857, respectively). CONCLUSION: The selected features of the I-3A index constructed using the RF-BFE algorithm can effectively predict moderate-to-severe liver inflammation in CHB patients.


Subject(s)
Hepatitis B, Chronic , Alanine Transaminase , Algorithms , Biomarkers , Hepatitis B e Antigens , Hepatitis B virus/genetics , Hepatitis B, Chronic/complications , Hepatitis B, Chronic/diagnosis , Humans , Inflammation , Liver Cirrhosis/diagnosis , ROC Curve
2.
Hepatol Res ; 48(3): E133-E145, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28707778

ABSTRACT

AIM: Chronic hepatitis B (CHB) patients with normal alanine aminotransferase (ALT) levels are not free from significant hepatic lesions. Recently, there has been an improved understanding of the clinical significance of quantitative hepatitis B core antibody levels (qAnti-HBc) during CHB management. In this cross-sectional study, we evaluated the utility of qAnti-HBc in identifying significant liver inflammation in CHB patients. METHODS: A total of 469 patients (training set, n = 363; validation set, n = 106) who underwent liver biopsy (LB) were included. The qAnti-HBc levels were quantified and the relationship between histology and serum markers was systematically analyzed. RESULTS: In the training set, qAnti-HBc levels were found to have significant diagnostic value for moderate to severe liver inflammation (≥G2) in all patients (area under the receiver operating characteristic curve [AUROC] = 0.768; 95% confidence interval [CI], 0.721-0.810; P < 0.001) and in patients with normal or near-normal ALT levels (AUROC = 0.767; 95% CI, 0.697-0.828; P < 0.001). Our novel index (AC index) for the identification of ≥G2 inflammation, which combined the qAnti-HBc and ALT levels, significantly improved diagnostic performance (AUROC = 0.813; 95% CI, 0.768-0.852) compared to the use of ALT alone (AUROC = 0.779; 95% CI, 0.732-0.821) in all patients. In the validation set, the AC index showed an improved AUROC of 0.890 (95% CI, 0.814-0.942) and 0.867 (95% CI, 0.749-0.943) in all patients and patients with normal ALT levels, respectively. CONCLUSIONS: The qAnti-HBc level predicts significant liver inflammation well, even in patients with normal or near-normal ALT levels. Compared with the conventional ALT level, the AC index is a more reliable non-invasive biomarker for significant liver inflammation in CHB patients.

3.
J Virol Methods ; 234: 96-100, 2016 08.
Article in English | MEDLINE | ID: mdl-27091097

ABSTRACT

The stable HBV-replicating cell lines, which carry replication-competent HBV genome stably integrated into the genome of host cell, are widely used to evaluate the effects of antiviral agents. However, current methods to generate HBV-replicating cell lines, which are mostly dependent on random integration of foreign DNA via plasmid transfection, are less-efficient and time-consuming. To address this issue, we constructed an all-in-one Sleeping Beauty transposon system (denoted pTSMP-HBV vector) for robust generation of stable cell lines carrying replication-competent HBV genome of different genotype. This vector contains a Sleeping Beauty transposon containing HBV 1.3-copy genome with an expression cassette of the SV40 promoter driving red fluorescent protein (mCherry) and self-cleaving P2A peptide linked puromycin resistance gene (PuroR). In addition, a PGK promoter-driven SB100X hyperactive transposase cassette is placed in the outside of the transposon in the same plasmid.The HBV-replicating stable cells could be obtained from pTSMP-HBV transfected HepG2 cells by red fluorescence-activated cell sorting and puromycin resistant cell selection within 4-week. Using this system, we successfully constructed four cell lines carrying replication-competent HBV genome of genotypes A-D. The replication and viral protein expression profiles of these cells were systematically characterized. In conclusion, our study provides a high-efficiency strategy to generate HBV-replicating stable cell lines, which may facilitate HBV-related virological study.


Subject(s)
Hepatitis B virus/physiology , Transposases/genetics , Virus Replication , Culture Techniques , DNA Replication , Flow Cytometry , Gene Transfer Techniques , Genetic Vectors , HeLa Cells , Hep G2 Cells , Hepatitis B virus/genetics , Humans , Luminescent Proteins , Red Fluorescent Protein
4.
J Virol Methods ; 228: 55-9, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26615806

ABSTRACT

Hepatitis B virus surface antigen (HBsAg) is an important biomarker used in the diagnosis of hepatitis B virus (HBV) infection, but false-negative results are still reported in the detection of HBsAg using commercial assays. In this study, we evaluated the qualitative properties of a novel HBsAg chemiluminescence enzyme immunoassay (CLEIA) assay--WTultra. WHO standard sample dilution series and samples from low-level HBsAg carriers (<1 ng/mL) were used to evaluate the sensitivity of the WTultra assay. Boston Biomedica, Inc. (BBI) hepatitis B seroconversion panels were used to assess the ability of the WTultra assay to detect the window period. In addition, dilution series of 22 serum samples with different genotypes, serotypes and HBsAg mutations were used to assess the WTultra assay, and these were compared with other commercial assays. The lower detection limit of the WTultra assay was 0.012 IU/mL, and it showed a high sensitivity (97.52%, 95% CI, 94.95-99.00) in the detection of 282 low-level HBsAg carriers (<1 ng/mL). In samples with various HBV genotypes, serotypes and HBsAg mutations, the WTultra assay yielded 117 positive results in 132 samples, which was significantly higher than the results with the other four commercial assays (89, 83, 65 and 45, respectively, p<0.01). In the assays of mutant strains, the WTultra assay detected 82 positive results in 90 samples, which was significantly better than the results for the Hepanostika HBsAg Ultra (58 positive) and Architect (55 positive) (p<0.01) assays, which in turn were significantly better than the Murex V.3 (41 positive, p=0.026) and AxSYM V2 (29 positive, p<0.01) assays. However, in the detection of 42 samples of wild-type strains with various genotypes and serotypes, no significant differences were observed among the WTultra (35 positive), Architect (28 positive) and Hepanostika HBsAg Ultra (31 positive) assays. However, the WTultra assay detected significantly more samples than the Murex V.3 (24 positive, p<0.01) and AxSYM V2 (16 positive, p<0.01) assays. In conclusion, the WTultra HBsAg assay has a high detection sensitivity and presents excellent results for the detection of mutants.


Subject(s)
Hepatitis B Surface Antigens/blood , Hepatitis B/diagnosis , Immunoenzyme Techniques , DNA, Viral/genetics , Genotype , Hepatitis B/virology , Hepatitis B Surface Antigens/genetics , Hepatitis B Surface Antigens/immunology , Hepatitis B virus/immunology , Humans , Immunoenzyme Techniques/instrumentation , Immunoenzyme Techniques/methods , Limit of Detection , Luminescent Measurements/instrumentation , Luminescent Measurements/methods , Mutation , Sensitivity and Specificity , Serogroup
5.
PLoS One ; 10(6): e0130209, 2015.
Article in English | MEDLINE | ID: mdl-26115521

ABSTRACT

Non invasive immunologic markers of virus-induced liver disease are unmet needs. We tested the clinical significance of quantitative total and IgM-anti-HBc in well characterized chronic-HBsAg-carriers. Sera (212) were obtained from 111 HBsAg-carriers followed-up for 52 months (28-216) during different phases of chronic-HBV-genotype-D-infection: 10 HBeAg-positive, 25 inactive-carriers (HBV-DNA≤2000IU/ml, ALT<30U/L), 66 HBeAg-negative-CHB-patients and 10 with HDV-super-infection. In 35 patients treated with Peg-IFN±nucleos(t)ide-analogues (NUCs) sera were obtained at baseline, end-of-therapy and week-24-off-therapy and in 22 treated with NUCs (for 60 months, 42-134m) at baseline and end-of-follow-up. HBsAg and IgM-anti-HBc were measured by Architect-assays (Abbott, USA); total-anti-HBc by double-antigen-sandwich-immune-assay (Wantai, China); HBV-DNA by COBAS-TaqMan (Roche, Germany). Total-anti-HBc were detectable in all sera with lower levels in HBsAg-carriers without CHB (immune-tolerant, inactive and HDV-superinfected, median 3.26, range 2.26-4.49 Log10 IU/ml) versus untreated-CHB (median 4.68, range 2.76-5.54 Log10 IU/ml), p<0.0001. IgM-anti-HBc positive using the chronic-hepatitis-cut-off" (0.130-S/CO) were positive in 102 of 212 sera (48.1%). Overall total-anti-HBc and IgM-anti-HBc correlated significantly (p<0.001, r=0.417). Total-anti-HBc declined significantly in CHB patients with response to Peg-IFN (p<0.001) and in NUC-treated patients (p<0.001); the lowest levels (median 2.68, range 2.12-3.08 Log10 IU/ml) were found in long-term responders who cleared HBsAg subsequently. During spontaneous and therapy-induced fluctuations of CHB (remissions and reactivations) total- and IgM-anti-HBc correlated with ALT (p<0.001, r=0.351 and p=0.008, r=0.185 respectively). Total-anti-HBc qualifies as a useful marker of HBV-induced-liver-disease that might help to discriminate major phases of chronic HBV infection and to predict sustained response to antivirals.


Subject(s)
Hepatitis B Antibodies/blood , Hepatitis B Antibodies/immunology , Hepatitis B Core Antigens/immunology , Hepatitis B virus/immunology , Hepatitis B/blood , Hepatitis B/immunology , Adult , Aged , Antiviral Agents/therapeutic use , Biomarkers , Carrier State , Female , Hepatitis B/drug therapy , Hepatitis B/virology , Hepatitis B, Chronic/blood , Hepatitis B, Chronic/drug therapy , Hepatitis B, Chronic/immunology , Hepatitis B, Chronic/virology , Humans , Kinetics , Male , Middle Aged , Treatment Outcome , Viral Load , Young Adult
6.
Anal Chem ; 87(10): 5173-80, 2015.
Article in English | MEDLINE | ID: mdl-25892477

ABSTRACT

Hepatitis B virus (HBV) genotyping plays an important role in the clinical management of chronic hepatitis B (CHB) patients. However, the current nucleic acid based techniques are expensive, time-consuming, and inconvenient. Here, we developed a novel DNA-independent HBV genotyping tool based on a one-step fluorescent lateral flow immunoassay (LFIA). Epitope-targeting immunization and screening techniques were used to develop HBV genotype specific monoclonal antibodies (mAbs). These mAbs were used to develop a multitest LFIA with a matched scanning luminoscope for HBV genotyping (named the GT-LFIA). The performance of this novel assay was carefully evaluated in well-characterized clinical cohorts. The GT-LFIA, which can specifically differentiate HBV genotypes A, B, C, and D in a pretreatment-free single test, was successfully developed using four genotype specific mAbs. The detection limits of the GT-LFIA for HBV genotypes A, B, C, and D were 2.5-10.0 IU HBV surface antigen/mL, respectively. Among the sera from 456 CHB patients, 439 (96.3%; 95% confidence interval (CI), 94.1-97.8%) were genotype-differentiable by the GT-LFIA and 437 (99.5%; 95% CI, 98.4-99.9%) were consistent with viral genome sequencing. In the 21 patients receiving nucleos(t)ide analogue therapy, for end-of-treatment specimens that were HBV DNA undetectable and were not applicable for DNA-dependent genotyping, the GT-LFIA presented genotyping results that were consistent with those obtained in pretreatment specimens by viral genome sequencing and the GT-LFIA. In conclusion, the novel GT-LFIA is a convenient, fast, and reliable tool for differential HBV genotyping, especially in patients with low or undetectable HBV DNA levels.


Subject(s)
Genotyping Techniques/methods , Hepatitis B virus/genetics , Immunoassay/methods , Amino Acid Sequence , Antibodies, Monoclonal/chemistry , Antibodies, Monoclonal/immunology , Antibody Specificity , Hepatitis B Surface Antigens/analysis , Hepatitis B Surface Antigens/immunology , Hepatitis B virus/immunology , Hepatitis B virus/physiology , Hepatitis B, Chronic/virology , Humans , Molecular Sequence Data , Spectrometry, Fluorescence , Time Factors
7.
Theranostics ; 5(3): 218-26, 2015.
Article in English | MEDLINE | ID: mdl-25553110

ABSTRACT

A recent study revealed that quantitative hepatitis B core antibody (qAnti-HBc) level could serve as a novel marker for predicting treatment response. In the present study, we further investigated the predictive value of qAnti-HBc level in HBeAg-positive patients undergoing PEG-IFN therapy. A total of 140 HBeAg-positive patients who underwent PEG-IFN therapy for 48 weeks and follow-up for 24 weeks were enrolled in this study. Serum samples were taken every 12 weeks post-treatment. The predictive value of the baseline qAnti-HBc level for treatment response was evaluated. Patients were further divided into 2 groups according to the baseline qAnti-HBc level, and the response rate was compared. Additionally, the kinetics of the virological and biochemical parameters were analyzed. Patients who achieved response had a significantly higher baseline qAnti-HBc level (serological response [SR], 4.52±0.36 vs. 4.19±0.58, p=0.001; virological response [VR], 4.53±0.35 vs. 4.22±0.57, p=0.005; combined response [CR], 4.50±0.36 vs. 4.22±0.58, p=0.009)). Baseline qAnti-HBc was the only parameter that was independently correlated with SR (p=0.008), VR (p=0.010) and CR(p=0.019). Patients with baseline qAnti-HBc levels ≥30,000 IU/mL had significantly higher response rates, more HBV DNA suppression, and better hepatitis control in PEG-IFN treatment. In conclusion, qAnti-HBc level may be a novel biomarker for predicting treatment response in HBeAg-positive patients receiving PEG-IFN therapy.


Subject(s)
Drug Monitoring/methods , Hepatitis B Antibodies/blood , Hepatitis B Core Antigens/immunology , Hepatitis B e Antigens/blood , Hepatitis B, Chronic/diagnosis , Hepatitis B, Chronic/drug therapy , Interferon-alpha/therapeutic use , Adult , Biomarkers/blood , DNA, Viral/blood , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Viral Load , Young Adult
8.
Medicine (Baltimore) ; 93(29): e322, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25546679

ABSTRACT

Previous studies have revealed antibody to hepatitis B core antigen (anti-HBc) levels as a predictor of treatment response in hepatitis B early antigen (HBeAg)-positive chronic hepatitis B (CHB) patients in both interferon and nucleos(t)ide analog therapy cohorts. However, there is no information about anti-HBc levels in the natural history of CHB. This study aimed to define anti-HBc levels of different phases in the natural history of CHB. Two hundred eleven treatment-naive CHB patients were included in the study. They were classified into 4 phases: immune tolerance (IT) phase (n = 39), immune clearance (IC) phase (n = 48), low or no-replicative (LR) phase (n = 55), and HBeAg-negative hepatitis (ENH, n = 69). Fifty patients who were HBsAg negative and anti-HBc positive were also recruited as past HBV infection (PBI) control group. Anti-HBc levels were measured by a newly developed double-sandwich immunoassay. Correlation of anti-HBc levels with alanine aminotransferase (ALT) and other HBV-related markers within each phase was performed. Serum anti-HBc levels were statistically significant between patients in different phases of CHB (P < 0.001). The median anti-HBc levels were: IT (3.17 log 10 IU/mL), IC (4.39 log 10 IU/mL), LR (3.29 log 10 IU/mL), ENH (4.12 log 10 IU/mL), and PBI (0.61 log 10 IU/mL). There existed a strong correlation in IC (r = 0.489, P < 0.001), a poor correlation in ENH (r = 0.275, P = 0.042), and no correlation in patients with ALT reached 5 times upper limit of normal (r = 0.120, P = 0.616). Anti-HBc levels show significant differences during the natural course of CHB. These results may provide some potentially useful insights into hepatitis B pathogenesis and immune activation against hepatitis B virus.


Subject(s)
Hepatitis B Antibodies/blood , Hepatitis B Core Antigens/immunology , Hepatitis B, Chronic/immunology , Adolescent , Adult , Aged , Alanine Transaminase/blood , Case-Control Studies , DNA, Viral/analysis , Female , Hepatitis B virus/genetics , Hepatitis B virus/immunology , Humans , Immune Tolerance , Male , Middle Aged , Prospective Studies , Young Adult
9.
Clin Vaccine Immunol ; 21(11): 1521-7, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25209557

ABSTRACT

Hepatitis B surface antigen (HBsAg) quantification has garnered attention because of its high predictive value in determining treatment responses. The HBsAg quantification assays, such as Architect and Elecsys, are commercially available, and more assays are in development. We aimed to compare the results of the Architect and Elecsys assays with those of a new assay, WTultra. The WTultra HBsAg assay is a sandwich chemiluminescent microplate enzyme immunoassay and provides an alternative choice which is more cost-effective and potentially applicable in developing or resource-constrained countries and areas. A total of 411 serum samples were collected from patients during various phases of chronic hepatitis B (CHB) infection. The samples were assessed using the three assays, and the results were compared and analyzed. The results for the Architect, Elecsys, and WTultra assays were well correlated according to the overall results for the samples (correlation coefficients, rArchitect versus WTultra = 0.936, rArchitect versus Elecsys = 0.952, and rWTultra versus Elecsys = 0.981) and the various infection phases (rArchitect versus WTultra ranging from 0.67 to 0.975, rArchitect versus Elecsys ranging from 0.695 to 0.982, and rWTultra versus Elecsys ranging from 0.877 to 0.99). Additionally, consistent results were observed according to genotype (genotype B: rArchitect versus WTultra = 0.976, rArchitect versus Elecsys = 0.978, and rWTultra versus Elecsys = 0.979; genotype C: rArchitect versus WTultra = 0.950, rArchitect versus Elecsys = 0.963, and rWTultra versus Elecsys = 0.981) and hepatitis B virus (HBV) DNA levels (rArchitect = 0.540, rWTultra = 0.553, and rElecsys = 0.580). In conclusion, the Elecsys and WTultra assays were well correlated with the Architect assay, irrespective of the CHB infection phase or genotype. All of these assays are reliable for HBsAg quantification.


Subject(s)
Hepatitis B Surface Antigens/blood , Hepatitis B, Chronic/virology , Luminescent Measurements/methods , Adolescent , Adult , Aged , Aged, 80 and over , Child , Female , Humans , Immunoassay/methods , Male , Middle Aged , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL