Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 55
Filter
2.
J Arrhythm ; 40(2): 317-324, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38586842

ABSTRACT

Background: The real-world data on the safety profile of ventricular tachycardia (VT) ablation among elderly patients is not well-established. This study aimed to evaluate the procedural outcomes among those aged 18-64 years versus those aged ≥65 years who underwent catheter ablation of VT. Method: Using the Nationwide Readmissions Database, our study included patients aged ≥18 years who underwent VT catheter ablation between 2017 and 2020. We divided the patients into non-elderly (18-64 years old) and elderly age groups (≥65 years old). We then analyzed the in-hospital procedural outcome and 30-day readmission between these two groups. Results: Our study included 2075 (49.1%) non-elderly patients and 2153 (50.9%) elderly patients who underwent VT ablation. Post-procedurally, elderly patients had significantly higher rates of prolonged index hospitalization (≥7 days; 35.5% vs. 29.3%, p < .01), non-home discharge (13.4% vs. 6.0%, p < .01), 30-day readmission (17.0% vs. 11.4%, p < .01), and early mortality (5.5% vs. 2.4%, p < .01). There was no significant difference in the procedural complications between two groups, namely vascular complications, hemopericardium/cardiac tamponade, cerebrovascular accident (CVA), major bleeding requiring blood transfusion, and systemic embolization. Through multivariable analysis, the elderly group was associated with higher odds of early mortality (OR: 7.50; CI 1.86-30.31, p = .01), non-home discharge (OR: 2.41; CI: 1.93-3.00, p < .01) and 30-day readmission (OR: 1.58; CI 1.32-1.89, p < .01). Conclusion: Elderly patients have worse in-hospital outcome, early mortality, non-home discharge, and 30-day readmission following catheter ablation for VT. There was no significant difference between elderly and non-elderly groups in the procedural complications.

3.
Article in English | MEDLINE | ID: mdl-38590268

ABSTRACT

INTRODUCTION: Ventricular tachycardia storm or electrical storm (ES) is a common complication following left ventricular assist device (LVAD) implantation. The factors contributing to ES and outcomes are less studied. The study aimed to determine the factors associated with ES and the probability of survival in patients undergoing LVAD in three tertiary centers over a span of 15 years. METHODS: We performed a retrospective cohort study on all patients who underwent LVAD implantation at the Mayo Clinic (Rochester, Phoenix, and Jacksonville) from January 1, 2006 to December 31, 2020. ES was defined as ≥3 episodes of sustained ventricular tachycardia over a period of 24 h with no identifiable reversible cause. Detailed chart reviews of the electronic health records within the Mayo Clinic and outside medical records were performed. RESULTS: A total of 883 patients who underwent LVAD implantation were included in our study. ES occurred in 7% (n = 61) of patients with a median of 13 days (interquartile range [IQR]: 5-297 days) following surgery. We found 57% of patients (n = 35) developed ES within 30 days, while 43% (n = 26) patients developed ES at a median of 545  (IQR 152-1032) days after surgery. Following ES, 26% of patients died within 1 year. Patients with ES had a significant association with a history of ventricular arrhythmias and implantable cardioverter defibrillator (ICD) shocks before the procedure. ES was significantly associated with reduced survival compared to patients without ES (hazards ratio [HR]: 1.92, 95% CI: 1.39-2.64, p < .001). CONCLUSION: Following LVAD implantation, the rate of ES was 7% with majority of ES occurring within 30 days of LVAD. Risk factors for ES included pre-implant history of ventricular arrhythmias and ICD shock. ES was significantly associated with reduced survival compared to patients without ES.

4.
Pacing Clin Electrophysiol ; 47(5): 626-634, 2024 May.
Article in English | MEDLINE | ID: mdl-38488756

ABSTRACT

BACKGROUND: Long-term outcomes of sterile lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) remain unclear. METHODS: We performed a retrospective study of a population residing in southeastern Minnesota with follow-up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE of sterile leads from January 1, 2000, to January 1, 2011, and had follow-up for at least 10 years or until their death were included. RESULTS: A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. Indications for subsequent lead extraction arose in 9.1% (n = 14) of patients with initial LA and 5.3% (n = 1) in patients with initial TLE, after an average of 7 years. Moreover, 28.6% of patients in the LA cohort who required subsequent extraction did not proceed with the extraction, and among those who proceeded, 60% had clinical success and 40% had a clinical failure. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges (5.2% vs. 5.3%). There was no difference in 10-year survival probability among the LA group and the TLE group (p = .64). CONCLUSION: An initial lead abandonment strategy was associated with more complicated subsequent extraction procedures compared to patients with an initial transvenous lead extraction strategy. However, there was no difference in 10-year survival probability between both lead management approaches.


Subject(s)
Device Removal , Humans , Male , Female , Retrospective Studies , Aged , Minnesota/epidemiology , Defibrillators, Implantable , Pacemaker, Artificial , Treatment Outcome , Middle Aged , Electrodes, Implanted
5.
J Electrocardiol ; 82: 19-26, 2024.
Article in English | MEDLINE | ID: mdl-38000149

ABSTRACT

BACKGROUND: Pectus excavatum (PEx) can cause cardiopulmonary limitations due to cardiac compression and displacement. There is limited data on electrocardiogram (ECG) alterations before and after PEx surgical repair, and ECG findings suggesting cardiopulmonary limitations have not been reported. The aim of this study is to explore ECG manifestations of PEx before and after surgery including associations with exercise capacity. METHODS: A retrospective review of PEx patients who underwent primary repair was performed. ECGs before and after surgical correction were evaluated and the associations between preoperative ECG abnormalities and cardiopulmonary function were investigated. RESULTS: In total, 310 patients were included (mean age 35.1 ± 11.6 years). Preoperative ECG findings included a predominant negative P wave morphology in V1, and this abnormal pattern significantly decreased from 86.9% to 57.4% (p < 0.001) postoperatively. The presence of abnormal P wave amplitude in lead II (>2.5 mm) significantly decreased from 7.1% to 1.6% postoperatively (p < 0.001). Right bundle branch block (RBBB) (9.4% versus 3.9%, p < 0.001), rsr' patterns (40.6% versus 12.9%, p < 0.001), and T wave inversion in leads V1-V3 (62.3% vs 37.7%, p < 0.001) were observed less frequently after surgery. Preoperative presence of RBBB (OR = 4.8; 95%CI 1.1-21.6) and T wave inversion in leads V1-3 (OR = 2.3; 95%CI 1.3-4.2) were associated with abnormal results in cardiopulmonary exercise testings. CONCLUSION: Electrocardiographic abnormalities in PEx are frequent and can revert to normal following surgery. Preoperative RBBB and T wave inversion in leads V1-3 suggested a reduction in exercise capacity, serving as a marker for the need for further cardiovascular evaluation of these patients.


Subject(s)
Electrocardiography , Funnel Chest , Humans , Young Adult , Adult , Middle Aged , Funnel Chest/complications , Funnel Chest/surgery , Heart , Bundle-Branch Block , Exercise Test/adverse effects
6.
J Cardiovasc Electrophysiol ; 35(1): 35-43, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37921096

ABSTRACT

BACKGROUND: Cardiac arrest (CA) is a leading cause of death in the United States (US). Social determinants of health may impact CA outcomes. We aimed to assess mortality trends, disparities, and the influence of the social vulnerability index (SVI) on CA outcomes in the young. METHODS: We conducted a cross-sectional analysis of age-adjusted mortality rates (AAMRs) related to CA in the United States from the Years 1999 to 2020 in individuals aged 35 years and younger. Data were obtained from death certificates and analyzed using log-linear regression models. We examined disparities in mortality rates based on demographic variables. We also explored the impact of the SVI on CA mortality. RESULTS: A total of 4792 CA deaths in the young were identified. Overall AAMR decreased from 0.20 in 1999 to 0.14 in 2020 with an average annual percentage change of -1.3% (p = .001). Black (AAMR: 0.30) and male populations (AAMR: 0.14) had higher AAMR compared with White (AAMR: 0.11) and female (AAMR: 0.11) populations, respectively. Nonmetropolitan (AAMR: 0.29) and Southern (AAMR: 0.26) regions were also impacted by higher AAMR compared with metropolitan (AAMR: 0.11) and other US census regions, respectively. A higher SVI was associated with greater mortality risks related to CA (risk ratio: 1.82 [95% CI, 1.77-1.87]). CONCLUSIONS: Our analysis of CA in the young revealed disparities based on demographics, with a decline in AAMR from 1999 to 2020. There is a correlation between a higher SVI and increased CA mortality risk, highlighting the importance of targeted interventions to address these disparities effectively.


Subject(s)
Eye Diseases, Hereditary , Heart Arrest , Humans , Female , Male , United States/epidemiology , Cross-Sectional Studies , Social Vulnerability , Heart Arrest/diagnosis
7.
J Arrhythm ; 39(5): 784-789, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37799789

ABSTRACT

Background: Real-world clinical data on the adverse events related to the use of cryoballoon catheter for pulmonary vein isolation remains limited. Objective: To report and describe the adverse events related to the use of Artic Front cryoballoon catheters (Arctic Front, Arctic Front Advance, and Arctic Front Advance Pro) reported in the Food and Drug Administration's (FDA) Manufacturers and User Defined Experience (MAUDE) database. Methods: We reviewed all the adverse events reported to the FDA MAUDE database over a 10.7-year study period from January 01, 2011 to September 31, 2021. All events were independently reviewed by two physicians. Results: During the study period, a total of 320 procedural-related adverse events reported in the MAUDE database were identified. The most common adverse event was transient or persistent phrenic nerve palsy (PNP), accounting for 48% of all events. This was followed by cardiac perforation (15%), pulmonary vein stenosis (8%), transient ischemic attack or stroke (6%), vascular injury (4%), transient or persistent ST-elevation myocardial infarction (3%), hemoptysis (2%), pericarditis (2%), and esophageal ulcer or fistula (1%). There were six reported intra-procedural death events as a result of cardiac perforation. Conclusion: The two most common procedural adverse events associated with cryoballoon ablation were PNP and cardiac perforation. All cases of procedural mortality were due to cardiac perforation.

8.
Am J Cardiol ; 206: 132-150, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37703679

ABSTRACT

Direct oral anticoagulants (DOACs) are a newer class of anticoagulants that inhibit factor Xa or factor IIa and include drugs such as rivaroxaban, apixaban, edoxaban, betrixaban, and dabigatran. Although vitamin K antagonists (VKAs) have been traditionally used to prevent thromboembolic events, DOACs have gained popularity because of their faster onset and offset of action and reduced need for monitoring. This study aimed to provide more data for anticoagulants in patients with atrial fibrillation with bioprosthetic heart valves by incorporating all available trials to date. A search was performed across 5 electronic databases to identify relevant studies. We analyzed the data using a pooled risk ratio for categorical outcomes and used the I2 test to determine heterogeneity. The quality of randomized controlled trials was assessed using the Cochrane risk of bias assessment tool, and the National Institutes of Health tool was used for observational studies. Our study included a frequentist network meta-analysis (MA) of the aggregate data to obtain the network estimates for the outcomes of interest. We retrieved 28 studies with a total of 74,660 patients with bioprosthetic heart valves. Our MA significantly showed that DOACs decrease the risk of all-cause bleeding (risk ratio [RR] 0.80, 95% confidence interval [CI] 0.75 to 0.85, p >0.00001), stroke and systemic embolization (RR 0.89, 95% CI 0.80 to 0.99, p = 0.03), and intracranial bleeding outcomes (RR 0.62, 95% CI 0.45 to 0.86, p = 0.004) compared with VKA. In contrast, there was no significant difference between the compared groups in major bleeding (RR = 0.92, 95% CI 0.84 to 1.02, p = 0.10) and all-cause mortality outcomes (RR = 0.96, 95% CI 0.85 to 1.07, p = 0.43), respectively. In addition, the network MA results did not favor any of the studied interventions over each other (p <0.05) regarding all-cause bleeding, mortality, stroke and systemic embolization, and major bleeding outcomes. In conclusion, our study found that DOACs are more effective in reducing the risk of bleeding, stroke, systemic embolism, and intracranial bleeding than VKAs. However, no significant difference was observed in the incidence of gastrointestinal bleeding, major bleeding, thromboembolic events, and all-cause mortality. In addition, our network MA did not identify any specific DOAC treatment as more favorable than others.


Subject(s)
Atrial Fibrillation , Stroke , Thromboembolism , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Network Meta-Analysis , Anticoagulants/therapeutic use , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Thromboembolism/epidemiology , Thromboembolism/etiology , Thromboembolism/prevention & control , Fibrinolytic Agents/therapeutic use , Intracranial Hemorrhages , Vitamin K , Administration, Oral
9.
Am J Cardiol ; 203: 444-450, 2023 09 15.
Article in English | MEDLINE | ID: mdl-37542954

ABSTRACT

The outcomes of leadless pacemaker (LP) implantation after transvenous lead removal (TLR) of infected cardiac implantable electronic devices (CIEDs) are not well-established. This study sought to describe the outcomes of LP implantation after TLR of infected CIED. We conducted a literature search using PubMed and Embase for a combination of terms including LP implantation, transvenous lead extraction, TLR, transvenous lead explant, infected CIED, infected pacemaker, and infected implantable cardioverter defibrillator. The inclusion criterion was LP implantation after TLR of infected CIED. The exclusion criterion was TLR for noninfectious reasons. Study end points included procedural complications and LP infection during follow-up. Of 132 publications reviewed, 13 studies with a total of 253 patients (74 ± 14 years of age, 174 [69%] males) were included. The most common indication of the initial device implantations was a high-degree atrioventricular block (n = 100 of 253, 39.5%). Of the 253 patients included, 105 patients (41.5%) underwent concomitant LP implantation during the TLR procedure, and 36 patients (14.2%) had temporary transvenous pacing as a bridge from TLR to LP implantation. Of the 148 patients with data on the type of CIED infection, 56.8% had systemic CIED infection and 43.2% had isolated pocket infection. Staphylococcus aureus was the most common causative organism in 33% of the reported patients. The LP was implanted an average of 5.4 ± 10.7 days after TLR of infected CIED. During the LP implantation, 1 patient (0.4%) had unsuccessful implantation because of an intraprocedural complication requiring sternotomy. After LP implantation, 2 patients (0.8%) developed groin hematoma, 2 patients (0.8%) developed femoral arteriovenous fistula, and 1 patient (0.4%) developed pericardial effusion requiring pericardiocentesis. During a mean follow-up of 11.3 ± 10.6 months, 3 patients (1.2%) developed pacemaker syndrome, 1 patient (0.4%) developed acute on chronic heart failure exacerbation, and only 1 patient (0.4%) developed LP-related infection requiring LP retrieval. This study suggests that LP implant is feasible and safe after removal of infected CIED with cumulative adverse events at 4% and a reinfection rate of 0.4%. Large prospective studies are needed to better evaluate the best timing of LP implantation after TLR of an infected CIED.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Prosthesis-Related Infections , Male , Humans , Female , Treatment Outcome , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/therapy , Prosthesis-Related Infections/etiology , Device Removal/adverse effects , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Retrospective Studies
10.
JACC Case Rep ; 16: 101890, 2023 Jun 21.
Article in English | MEDLINE | ID: mdl-37396315

ABSTRACT

Congenital right coronary artery-superior vena cava (RCA-SVC) fistula is rare and typically does not manifest any symptoms until the fifth decade of life. The present case demonstrates a 48-year-old woman who developed Sinus node dysfunction of unknown cause after Percutaneous coil embolization of the RCA-SVC fistula requiring permanent pacemaker. (Level of Difficulty: Intermediate.).

12.
Heart Rhythm ; 20(10): 1358-1367, 2023 10.
Article in English | MEDLINE | ID: mdl-37355026

ABSTRACT

BACKGROUND: Brugada syndrome is an inherited arrhythmic disease associated with major arrhythmic events (MAE). Risk predictive scores were previously developed with various performances. OBJECTIVE: The purpose of this study was to create a novel score-Predicting Arrhythmic evenT (PAT)-with internal and external validation. METHODS: A systematic review was performed to identify risk factors for MAE. The odds ratios (ORs) of each factor were pooled across studies. The PAT scoring scheme was developed based on pooled ORs. The PAT score was internally validated with published 105 Asian patients (follow-up 8.0 ± 4.1 [SD] years) and externally validated with unpublished 164 multiracial patients (82.3% White, 14.6% Asian, 3.2% Black; mean follow-up 8.0 ± 6.9 years) with Brugada syndrome. Performances were assessed and compared with previous scores using receiver operating characteristic curve (ROC) analysis. RESULTS: Sixty-seven studies published between 2002 and 2022 from 26 countries (7358 patients) were included. Pooled ORs were estimated, indicating that 15 of 23 risk factors were significant. The PAT score was then developed accordingly. The PAT score had significantly better discrimination (ROC 0.9671) than the BRUGADA-RISK score (ROC 0.7210; P = .006), Shanghai Score System (ROC 0.7079; P = .003), and Sieira et al score (ROC 0.8174; P = .026) in an external validation cohort. PAT score ≥ 10 predicted the first MAE with 95.5% sensitivity and 89.1% specificity (ROC 0.9460) and the recurrent MAE (ROC 0.7061) with 15.4% sensitivity and 93.3% specificity. CONCLUSION: The PAT score was shown to be useful in predicting MAE for primary prevention in patients with Brugada syndrome.


Subject(s)
Brugada Syndrome , Humans , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Electrocardiography , China , Risk Factors , Risk Assessment , Death, Sudden, Cardiac/etiology
14.
J Arrhythm ; 39(2): 198-206, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37021015

ABSTRACT

Background: The incidence and impact of noise in a subcutaneous implantable cardioverter defibrillator (S-ICD) after left ventricular assist device (LVAD) implantation is not well established. Methods: We performed a retrospective study of patients implanted with LVAD and with a pre-existing S-ICD between January 2005 and December 2020 at the three Mayo Clinic centers (Minnesota, Arizona, and Florida). Results: Of the 908 LVAD patients, a pre-existing S-ICD was present in 9 patients (mean age 49.1 ± 13.7 years, 66.7% males), 100% with Boston Scientific third-generation EMBLEM MRI S-ICD, 11% with HeartMate II (HM II), 44% with HeartMate 3 (HM 3), and 44% with HeartWare (HW) LVAD. The incidence of noise from LVAD-related electromagnetic interference (EMI) was 33% and was only seen with HM 3 LVAD. Multiple measures attempted to resolve noise, including using alternative S-ICD sensing vector, adjusting S-ICD time zone, and increasing LVAD pump speed, were unsuccessful, necessitating S-ICD device therapies to be turned off permanently. Conclusions: The incidence of LVAD-related S-ICD noise is high in patients with concomitant LVAD and S-ICD with significant impact on device function. As conservative management failed to resolve the EMI, the S-ICDs had to be programmed off to avoid inappropriate shocks. This study highlights the importance of awareness of LVAD-SICD device interference and the need to improve S-ICD detection algorithms to eliminate noise.

15.
JACC Clin Electrophysiol ; 8(12): 1566-1575, 2022 12.
Article in English | MEDLINE | ID: mdl-36543507

ABSTRACT

BACKGROUND: Recognition of the causes of early mortality (≤30 days) after transvenous lead removal (TLR) is an essential step for the development of quality improvement programs. OBJECTIVES: This study sought to determine the causes of early mortality after TLR and to further understand the circumstances surrounding death after TLR. METHODS: A retrospective analysis was performed of all patients undergoing TLR from January 1, 2001, to January 1, 2021, at the Mayo Clinic (Rochester, Minnesota; Phoenix, Arizona; and Jacksonville, Florida). Causes of death were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system and outside records when available. The causes of death were further characterized based on whether it was related to the TLR procedure. RESULTS: A total of 2,319 patients were included in the study. The overall 30-day all-cause mortality rate was 3% (n = 69). Among all 30-day deaths, infection was the most common primary cause of death (42%). This was followed by decompensated heart failure (17%), procedure-related death (10%), sudden cardiac arrest (7%), and respiratory failure (6%). The 30-day mortality rate directly due to complications associated with the TLR procedure was 0.3%. One-third of deaths (33%) occurred after discharge from the index hospitalization; among these, 43% were readmitted before their death, 35% died at home or at a nursing facility, and 22% were discharged on comfort care and died in hospice. The main reasons for readmission before death were sepsis and decompensated heart failure. CONCLUSIONS: The majority (90%) of 30-day mortality after TLR was not due to complications associated with TLR procedures. The primary causes were infection and decompensated heart failure. This highlights the importance of increased emphasis on postprocedure management of infection and heart failure to reduce postoperative mortality, including after hospital discharge.


Subject(s)
Heart Failure , Hospitalization , Humans , Retrospective Studies , Risk Factors , Heart Failure/surgery , Minnesota/epidemiology
16.
Circ Arrhythm Electrophysiol ; 15(9): e007960, 2022 09.
Article in English | MEDLINE | ID: mdl-36074973

ABSTRACT

Sinus tachycardia (ST) is ubiquitous, but its presence outside of normal physiological triggers in otherwise healthy individuals remains a commonly encountered phenomenon in medical practice. In many cases, ST can be readily explained by a current medical condition that precipitates an increase in the sinus rate, but ST at rest without physiological triggers may also represent a spectrum of normal. In other cases, ST may not have an easily explainable cause but may represent serious underlying pathology and can be associated with intolerable symptoms. The classification of ST, consideration of possible etiologies, as well as the decisions of when and how to intervene can be difficult. ST can be classified as secondary to a specific, usually treatable, medical condition (eg, pulmonary embolism, anemia, infection, or hyperthyroidism) or be related to several incompletely defined conditions (eg, inappropriate ST, postural tachycardia syndrome, mast cell disorder, or post-COVID syndrome). While cardiologists and cardiac electrophysiologists often evaluate patients with symptoms associated with persistent or paroxysmal ST, an optimal approach remains uncertain. Due to the many possible conditions associated with ST, and an overlap in medical specialists who see these patients, the inclusion of experts in different fields is essential for a more comprehensive understanding. This article is unique in that it was composed by international experts in Neurology, Psychology, Autonomic Medicine, Allergy and Immunology, Exercise Physiology, Pulmonology and Critical Care Medicine, Endocrinology, Cardiology, and Cardiac Electrophysiology in the hope that it will facilitate a more complete understanding and thereby result in the better care of patients with ST.


Subject(s)
COVID-19 , Postural Orthostatic Tachycardia Syndrome , Humans , Tachycardia, Sinus/diagnosis , Tachycardia, Sinus/therapy
17.
Eur Heart J Case Rep ; 6(6): ytac200, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35693027

ABSTRACT

Background: Fever, alcohol, and sodium channel blockers can unmask Brugada pattern and may also induce arrhythmias in Brugada syndrome. We report a case of unmasked Type-1 Brugada pattern presenting with ventricular fibrillation that was induced by a tetrahydrocannabinol vaping. Case summary: A 48-year-old male with a past medical history of hypertension treated with hydrochlorothiazide and back pain controlled with tetrahydrocannabinol vaping presented with sudden cardiac arrest from ventricular fibrillation, which was terminated with defibrillation. Electrocardiogram after resuscitation showed a new Type-1 Brugada pattern compared to a previous normal baseline electrocardiogram. Echocardiography and coronary angiogram were unremarkable. Complete blood count and chemistries were unremarkable except for mild hypokalaemia (K = 3.3 mmol/L). After correction of the hypokalaemia, the Type-1 Brugada pattern persisted. Urine drug screen was positive for tetrahydrocannabinol (60 ng/mL). Genetic testing was negative for inherited arrhythmic disease and cardiomyopathy gene panels. Discussion: The patient's type-1 Brugada pattern and ventricular fibrillation were likely induced by vaping tetrahydrocannabinol. He underwent secondary prevention with an implantable cardioverter-defibrillator. He abstains from cannabis and Type-1 Brugada pattern is normalized. There was no arrhythmic event at his 18-month follow-up appointment with abstinence from tetrahydrocannabinol.

18.
J Appl Clin Med Phys ; 23(3): e13520, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35066975

ABSTRACT

Magnetic resonance imaging (MRI) is a valuable imaging modality for the assessment of both cardiac and non-cardiac structures. With a growing population of patients with cardiovascular implantable electronic devices (CIEDs), 50%-75% of these patients will need an MRI. MRI-conditional CIEDs have demonstrated safety of MRI scanning with such devices, yet non-conditional devices such as hybrid CIEDs which have generator and lead brand mismatch may pose a safety risk. In this retrospective study, we examined the outcomes of patients with hybrid CIEDs undergoing MRI compared to those patients with non-hybrid CIEDs. A total of 349 patients were included, of which 24 patients (7%) had hybrid CIEDs. The primary endpoint was the safety of MRI for patients with hybrid CIEDs as compared to those with non-hybrid devices, measured by the rate of adverse events, including death, lead or generator failure needing immediate replacement, loss of capture, new onset arrhythmia, or power-on reset. Secondary endpoints consisted of pre- and post-MRI changes of decreased P-wave or R-wave sensing by ≥50%, changes in pacing lead impedance by ≥50 ohms, increase in pacing thresholds by ≥ 0.5 V at 0.4 ms, and decreasing battery voltage of ≥ 0.04 V. The primary endpoint of any adverse reaction was present in 1 (4.2%) patient with a hybrid device, and consistent of atrial tachyarrhythmia, and in 10 (3.1%) patients with a non-hybrid device, and consisted of self-limited atrial and non-sustained ventricular arrhythmias; this was not statistically significant. No significant differences were found in the secondary endpoints. This study demonstrates that MRI in patients with hybrid CIEDs does not result in increased patient risk or significant device changes when compared to those patients who underwent MRI with non-hybrid CIEDs.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Electronics , Humans , Magnetic Resonance Imaging/methods , Retrospective Studies
19.
Heart Rhythm ; 19(5): 768-775, 2022 05.
Article in English | MEDLINE | ID: mdl-34968739

ABSTRACT

BACKGROUND: Cardiovascular implantable electronic device (CIED) infections are associated with increased mortality and morbidity. OBJECTIVE: This study sought to evaluate the impact of early vs delayed transvenous lead removal (TLR) on in-hospital mortality and outcomes in patients with CIED infection. METHODS: Using the nationally representative, all payer, Nationwide Readmissions Database, we evaluated patients undergoing TLR for CIED infection between January 1, 2016, and December 31, 2018. The timing of TLR was determined on the basis of hospitalization days after the initial admission for CIED infection. The impact of early (≤7 days) vs delayed (>7 days) TLR on mortality and major adverse events was studied. RESULTS: Of the 12,999 patients who underwent TLR for CIED infection, 8834 (68%) underwent early TLR and 4165 (32%) underwent delayed TLR. Delayed TLR was associated with a significant increase in in-hospital mortality (8.3% vs 3.5%; adjusted odds ratio 1.70; 95% confidence interval 1.43-2.03; P < .001). Subgroup analysis of patients with CIED infection and systemic infection showed that delayed TLR in patients with systemic infection was associated with a higher rate of in-hospital mortality compared with early TLR (10.4% vs 7.5%; adjusted odds ratio 1.24; 95% confidence interval 1.04-1.49; P < .019). Delayed TLR was also associated with significantly higher adjusted odds of major adverse events and postprocedural length of stay. CONCLUSION: These data suggest that delayed TLR in patients with CIED infection is associated with increased in-hospital mortality and major adverse events, especially in patients with systemic infection.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Prosthesis-Related Infections , Defibrillators, Implantable/adverse effects , Device Removal/adverse effects , Electronics , Hospitalization , Humans , Pacemaker, Artificial/adverse effects , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/surgery , Retrospective Studies
SELECTION OF CITATIONS