ABSTRACT

This article presents the concept of an implantable cage system that can house and protect implanted biomedical sensing and therapeutic devices in the body. Cylinder-shaped cages made of porous polyvinyl alcohol (PVA) sheets with an 80-µm pore size and/or stainless steel meshes with 0.54-mm openings were implanted subcutaneously in the dorsal region of rats for 5 weeks. Analysis of the explanted cages showed the formation of fibrosis tissue around the cages. PVA cages had fibrotic tissue growing mostly along the outer surface of cages, while stainless steel cages had fibrotic tissue growing into the inside surface of the cage structure, due to the larger porosity of the stainless steel meshes. As the detection of target molecules with short time lags for biosensors and mass transport with low diffusion resistance into and out of certain therapeutic devices are critical for the success of such devices, we examined whether the fibrous tissue formed around the cages were permeable to molecules of our interest. For that purpose, bath diffusion and microfluidic chamber diffusion experiments using solutions containing the target molecules were performed. Diffusion of sodium, potassium and urea through the fibrosis tissue was confirmed, thus suggesting the potential of these cylindrical cages surrounded by fibrosis tissue to successfully encase implantable sensors and therapeutic apparatus.


Subject(s)
Implants, Experimental , Polyvinyl Alcohol , Stainless Steel , Surgical Mesh , Animals , Fibrosis/etiology , Fibrosis/physiopathology , Male , Porosity , Rats , Rats, Sprague-Dawley
2.
PLoS One ; 7(1): e25387, 2012.
Article in English | MEDLINE | ID: mdl-22247754

ABSTRACT

OBJECTIVES: To identify genetic factors that would be predictive of individuals who require an implantable cardioverter-defibrillator (ICD), we conducted a genome-wide association study among individuals with an ICD who experienced a life-threatening arrhythmia (LTA; cases) vs. those who did not over at least a 3-year period (controls). BACKGROUND: Most individuals that receive implantable cardioverter-defibrillators never experience a life-threatening arrhythmia. Genetic factors may help identify who is most at risk. METHODS: Patients with an ICD and extended follow-up were recruited from 34 clinical sites with the goal of oversampling those who had experienced LTA, with a cumulative 607 cases and 297 controls included in the analysis. A total of 1,006 Caucasian patients were enrolled during a time period of 13 months. Arrhythmia status of 904 patients could be confirmed and their genomic data were included in the analysis. In this cohort, there were 704 males, 200 females, and the average age was 73.3 years. We genotyped DNA samples using the Illumina Human660 W Genotyping BeadChip and tested for association between genotype at common variants and the phenotype of having an LTA. RESULTS AND CONCLUSIONS: We did not find any associations reaching genome-wide significance, with the strongest association at chromosome 13, rs11856574 at P = 5×10⁻6. Loci previously implicated in phenotypes such as QT interval (measure of the time between the start of the Q wave and the end of the T wave as measured by electrocardiogram) were not found to be significantly associated with having an LTA. Although powered to detect such associations, we did not find common genetic variants of large effect associated with having a LTA in those of European descent. This indicates that common gene variants cannot be used at this time to guide ICD risk-stratification. TRIAL REGISTRATION: ClinicalTrials.gov NCT00664807.


Subject(s)
Arrhythmias, Cardiac/genetics , Arrhythmias, Cardiac/mortality , DNA Copy Number Variations/genetics , Defibrillators, Implantable , Genetic Variation/genetics , Genome-Wide Association Study , Aged , Case-Control Studies , Cohort Studies , Female , Follow-Up Studies , Genotype , Humans , Male , Survival Rate
3.
Europace ; 12(3): 424-9, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20139118

ABSTRACT

Implantable cardioverter-defibrillator (ICD) therapy is effective in primary and secondary prevention for patients who are at high risk of sudden cardiac death. However, the current risk stratification of patients who may benefit from this therapy is unsatisfactory. Single nucleotide polymorphisms (SNPs) are DNA sequence variations occurring when a single nucleotide in the genome differs among members of a species. A novel concept has emerged being that these common genetic variations might modify the susceptibility of a certain population to specific diseases. Thus, genetic factors may also modulate the risk for arrhythmias and sudden cardiac death, and identification of common variants could help to better identify patients at risk. The DISCOVERY study is an interventional, longitudinal, prospective, multi-centre diagnostic study that will enrol 1287 patients in approximately 80 European centres. In the genetic part of the DISCOVERY study, candidate gene polymorphisms involved in coding of the G-protein subunits will be correlated with the occurrence of ventricular arrhythmias in patients receiving an ICD for primary prevention. Furthermore, in order to search for additional sequence variants contributing to ventricular arrhythmias, a genome-wide association study will be conducted if sufficient a priori evidence can be gathered. In the second part of the study, associations of SNPs with ventricular arrhythmias will be sought and a search for potential new biological arrhythmic pathways will be investigated. As it is a diagnostic study, DISCOVERY will also investigate the impact of long-term device diagnostic data on the management of patients suffering from chronic cardiac disease as well as medical decisions made regarding their treatment.


Subject(s)
Defibrillators, Implantable , Genome-Wide Association Study , Polymorphism, Single Nucleotide , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/genetics , Chromogranins , GTP-Binding Protein alpha Subunits, Gq-G11/genetics , GTP-Binding Protein alpha Subunits, Gs/genetics , Genetic Markers , Genetic Predisposition to Disease/epidemiology , Genetic Testing , Heterotrimeric GTP-Binding Proteins/genetics , Humans , Longitudinal Studies , Multicenter Studies as Topic , Risk Factors , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/therapy
4.
Biosens Bioelectron ; 19(3): 219-26, 2003 Nov 30.
Article in English | MEDLINE | ID: mdl-14611757

ABSTRACT

We report on a novel technique to develop an optical immunosensor based on fluorescence resonance energy transfer (FRET). IgG antibodies were labeled with acceptor fluorophores while one of three carrier molecules (protein A, protein G, or F(ab')2 fragment) was labeled with donor fluorophores. The carrier molecule was incubated with the antibody to allow specific binding to the Fc portion. The labeled antibody-protein complex was then exposed to specific and nonspecific antigens, and experiments were designed to determine the 'in solution' response. The paper reports the results of three different donor-acceptor FRET pairs, fluorescein isothiocyanate/tetramethylrhodamine isothiocyanate, Texas Red/Cy5, and Alexa Fluor 546/Alexa Fluor 594. The effects of the fluorophore to protein conjugation ratio (F/P ratio) and acceptor to donor fluorophore ratios between the antibody and protein (A/D ratio) were examined. In the presence of specific antigens, the antibodies underwent a conformational change, resulting in an energy transfer from the donor to the acceptor fluorophore as measured by a change in fluorescence. The non-specific antigens elicited little or no changes. The Alexa Fluor FRET pair demonstrated the largest change in fluorescence, resulting in a 35% change. The F/P and A/D ratio will affect the efficiency of energy transfer, but there exists a suitable range of A/D and F/P ratios for the FRET pairs. The feasibility of the FRET immunosensor technique was established; however, it will be necessary to immobilize the complexes onto optical substrates so that consistent trends can be obtained that would allow calibration plots.


Subject(s)
Antigens/analysis , Antigens/chemistry , Biosensing Techniques/methods , Fluorescence Polarization Immunoassay/methods , Fluorescence Resonance Energy Transfer/methods , Immunoglobulin G/analysis , Immunoglobulin G/chemistry , Antigen-Antibody Complex/analysis , Antigen-Antibody Complex/chemistry , Antigen-Antibody Complex/immunology , Antigens/immunology , Biosensing Techniques/instrumentation , Equipment Design , Equipment Failure Analysis , Fluorescence Polarization Immunoassay/instrumentation , Fluorescence Resonance Energy Transfer/instrumentation , Immunoglobulin Fab Fragments/analysis , Immunoglobulin Fab Fragments/chemistry , Immunoglobulin Fab Fragments/immunology , Nerve Tissue Proteins/analysis , Nerve Tissue Proteins/chemistry , Nerve Tissue Proteins/immunology , Reproducibility of Results , Sensitivity and Specificity , Staphylococcal Protein A/analysis , Staphylococcal Protein A/chemistry , Staphylococcal Protein A/immunology