Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Publication year range
1.
Am J Physiol Regul Integr Comp Physiol ; 323(4): R445-R456, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-35938686

ABSTRACT

High-altitude (HA) exposure may stimulate significant physiological and molecular changes, resulting in HA-related illnesses. HA may impact oxidative stress, antioxidant capacity, and iron homeostasis, yet it is unclear how both repeated exposure and HA acclimatization may modulate such effects. Therefore, we assessed the effects of weeklong repeated daily HA exposure (2,900-5,050 m) in altitude-naïve individuals (n = 21 individuals, 13 females, mean ± SD, 25.3 ± 3.7 yr) to mirror the working schedule of HA workers (n = 19 individuals, all males, 41.1 ± 9.4 yr) at the Atacama Large Millimeter Array (ALMA) Observatory (San Pedro de Atacama, Chile). Markers of oxidative stress, antioxidant capacity, and iron homeostasis were measured in blood plasma. Levels of protein oxidation (P < 0.001) and catalase activity (P = 0.023) increased and serum iron (P < 0.001), serum ferritin (P < 0.001), and transferrin saturation (P < 0.001) levels decreased with HA exposure in both groups. HA workers had lower levels of oxidative stress, and higher levels of antioxidant capacity, iron supply, and hemoglobin concentration as compared with altitude-naïve individuals. On a second week of daily HA exposure, changes in levels of protein oxidation, glutathione peroxidase, and nitric oxide metabolites were lower as compared with the first week in altitude-naïve individuals. These results indicate that repeated exposure to HA may significantly alter oxidative stress and iron homeostasis, and the degree of such changes may be dependent on if HA is visited naïvely or routinely. Further studies are required to fully elucidate differences in HA-induced changes in oxidative stress and iron homeostasis profiles among visitors of HA.


Subject(s)
Altitude Sickness , Antioxidants , Altitude , Antioxidants/metabolism , Biomarkers/metabolism , Catalase/metabolism , Ferritins/metabolism , Glutathione Peroxidase , Hemoglobins/metabolism , Humans , Iron/metabolism , Male , Nitric Oxide/metabolism , Oxidative Stress , Transferrins/metabolism , Transferrins/pharmacology
2.
J. health med. sci. (Print) ; 8(1): 15-20, ene.-mar. 2022. tab
Article in English | LILACS | ID: biblio-1391822

ABSTRACT

The Chilean workforce has over 200,000 people that are intermittently exposed to altitudes over 4000 m. In 2012, the Ministry of Health provided a technical guide for high altitude workers that included a series of actions to mitigate the effects of hypoxia. Previous studies have shown the positive effect of oxygen enrichment at high altitudes. The Atacama Large Millimeter / submillimeter Arrays (ALMA) radiotelescope operate at 5,050 m (Array Operation Site, AOS) and is the only place in the world where Pressure Swing Adsorption (PSA) and Liquid Oxygen technologies have been installed at a large scale. Here we discuss our experience using oxygen supplementation at ALMA, to prevent the malaise and/or risks associated with exposure at 5,050 m. Antenna operators experienced chronic intermittent hypobaric hypoxia (CIHH, shiftwork 8 days HA*6 days rest SL) over 4 years. Studies to define normal O2 saturation values were performed in OSF and AOS by continuous recording during the shift. The outcomes showed no differences between production procedures (PSA or Liquid oxygen) in regulating oxygen availability at AOS facilities. As a result, big-scale installations have difficulties reaching the appropriate oxygen concentration due to leaks in high mobility areas. In addition, the PSA plant requires adequation and maintenance to operate at a very high altitude.


La fuerza laboral chilena cuenta con más de 200.000 personas que están expuestas intermitentemente a altitudes superiores a los 4000 m. En 2012, el Ministerio de Salud entregó una guía técnica para trabajadores de altura que incluía una serie de acciones para mitigar los efectos de la hipoxia. Estudios anteriores han demostrado el efecto positivo del enriquecimiento de oxígeno en altitudes elevadas. El radiotelescopio Atacama Large Millimeter/submillimeter Arrays (ALMA) opera a 5.050 m (Array Operation Site, AOS) y es el único lugar en el mundo donde se han instalado tecnologías de adsorción por cambio de presión (PSA) y oxígeno líquido a gran escala. Aquí discutimos nuestra experiencia usando suplementos de oxígeno en ALMA, para prevenir el malestar y/o los riesgos asociados con la exposición a 5.050 m. Los operadores de antena experimentaron hipoxia hipobárica intermitente crónica (CIHH, trabajo por turnos 8 días HA*6 días descanso SL) durante 4 años. Se realizaron estudios para definir valores normales de saturación de O2 en OSF y AOS mediante registro continuo durante el turno. Los resultados no mostraron diferencias entre los procedimientos de producción (PSA u oxígeno líquido) en la regulación de la disponibilidad de oxígeno en las instalaciones de AOS. Como resultado, las instalaciones a gran escala tienen dificultades para alcanzar la concentración de oxígeno adecuada debido a fugas en áreas de alta movilidad. Además, la planta de PSA requiere de adecuación y mantenimiento para operar a gran altura.


Subject(s)
Humans , Oxygen/administration & dosage , Hypoxia/physiopathology , Blood Pressure/physiology , Models, Molecular , Desert , Absorption , Altitude , Telescopes
3.
Front Physiol ; 12: 775240, 2021.
Article in English | MEDLINE | ID: mdl-34955888

ABSTRACT

The Chilean workforce has over 200,000 people that are intermittently exposed to altitudes over 4,000 m. In 2012, the Ministry of Health provided a technical guide for high-altitude workers that included a series of actions to mitigate the effects of hypoxia. Previous studies have shown the positive effect of oxygen enrichment at high altitudes. The Atacama Large Millimeter/submillimeter Array (ALMA) radiotelescope operates at 5,050 m [Array Operations Site (AOS)] and is the only place in the world where pressure swing adsorption (PSA) and liquid oxygen technologies have been installed at a large scale. These technologies reduce the equivalent altitude by increasing oxygen availability. This study aims to perform a retrospective comparison between the use of both technologies during operation in ALMA at 5,050 m. In each condition, variables such as oxygen (O2), temperature, and humidity were continuously recorded in each AOS rooms, and cardiorespiratory variables were registered. In addition, we compared portable O2 by using continuous or demand flow during outdoor activities at very high altitudes. The outcomes showed no differences between production procedures (PSA or liquid oxygen) in regulating oxygen availability at AOS facilities. As a result, big-scale installations have difficulties reaching the appropriate O2 concentration due to leaks in high mobility areas. In addition, the PSA plant requires adequacy and maintenance to operate at a very high altitude. A continuous flow of 2-3 l/min of portable O2 is recommended at 5,050 m.

4.
High Alt Med Biol ; 20(4): 361-374, 2019 12.
Article in English | MEDLINE | ID: mdl-31651199

ABSTRACT

Background: We investigated altitude effects on different cognitive domains among perennial shift-workers at the Atacama Large Millimeter/submillimeter Array Observatory (5050 m), Chile. Materials and Methods: Twenty healthy male workers were recruited and assigned to either a moderate-altitude first (MAF group, Test 1: 2900 m and Test 2: 5050 m) or to a high-altitude first (HAF group, Test 1: 5050 m and Test 2: 2900 m). Test 1 was conducted at the beginning and Test 2 at the end of the shift-work week. Processing speed (RTI, reaction time), attention (AST, attention-switching task, and RVP, rapid visual processing), and executive function (OTS, One Touch Stockings of Cambridge) were assessed. Results: Of the three cognitive domains assessed, only processing speed showed altitude-at-test group interaction (RTI median five choice reaction time: F1, 17 = 6.980, [Formula: see text] = 0.291, p = 0.017). With acclimatization, there was a decrease in AST reaction latency mean (t17 = -2.155, dz = 1.086, p = 0.046), an increase in RVP accuracy (t17 = 2.733, dz = 1.398, p = 0.014), and a decrease in OTS mean latency first choice (t17 = -2.375, dz = 1.211, p = 0.03). Decreased variability in cognitive function was observed in AST reaction latency standard deviation (t17 = -2.524, dz = 1.282, p = 0.022) and in RVP response latency standard deviation (t17 = -2.35, dz = 1.177, p = 0.03) with acclimatization. At 5050 m of elevation, SpO2 was positively correlated with executive function in the MAF group (OTS problems solved on first choice: r(5) = 0.839, p = 0.018) and negatively correlated with executive function latency standard deviations in the HAF group (OTS latency to first choice standard deviation: r(10) = -0.618, p = 0.032). Conclusions: Our findings highlight the importance of acclimatization and improvement of blood oxygen level, even among high altitude-experienced workers, to optimize performance of cognitively demanding work and reduce high altitude-associated health risks.


Subject(s)
Altitude Sickness/psychology , Cognitive Dysfunction/etiology , Environmental Exposure/adverse effects , Occupational Diseases/psychology , Occupational Exposure/adverse effects , Acclimatization/physiology , Adult , Altitude , Altitude Sickness/etiology , Chile , Cognition/physiology , Humans , Male , Middle Aged , Neuropsychological Tests , Occupational Diseases/etiology , Reaction Time
5.
Front Physiol ; 9: 187, 2018.
Article in English | MEDLINE | ID: mdl-29628892

ABSTRACT

It is estimated that labor activity at high altitudes in Chile will increase from 60,000 to 120,000 workers by the year 2020. Oxygenation of spaces improves the quality of life for workers at high geographic altitudes (<5,000 m). The aim of this study was to determine the effect of a mobile oxygen module system on cardiorespiratory and neuropsychological performance in a population of workers from Atacama Large Millimeter/submillimeter Array (ALMA, 5,050 m) radiotelescope in the Chajnantor Valley, Chile. We evaluated pulse oximetry, systolic and diastolic arterial pressure (SAP/DAP), and performed neuropsychological tests (Mini-Mental State examination, Rey-Osterrieth Complex Figure test) at environmental oxygen conditions (5,050 m), and subsequently in a mobile oxygenation module that increases the fraction of oxygen in order to mimic the higher oxygen partial pressure of lower altitudes (2,900 m). The use of module oxygenation at an altitude of 5,050 m, simulating an altitude of 2,900 m, increased oxygen saturation from 84 ± 0.8 to 91 ± 0.8% (p < 0.00001), decreased heart rate from 90 ± 8 to 77 ± 12 bpm (p < 0.01) and DAP from 96 ± 3 to 87 ± 5 mmHg (p < 0.01). In addition, mental cognitive state of workers (Mini-Mental State Examination) shown an increased from 19 to 31 points (p < 0.02). Furthermore, the Rey-Osterrieth Complex Figure test (memory) shown a significant increase from 35 to 70 (p < 0.0001). The results demonstrate that the use of an oxygen module system at 5,050 m, simulating an altitude equivalent to 2,900 m, by increasing FiO2 at 28%, significantly improves cardiorespiratory response and enhances neuropsychological performance in workers exposed to an altitude of 5,050 m.

6.
High Alt Med Biol ; 15(3): 356-63, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25162792

ABSTRACT

PURPOSE: To discern whether arrhythmogenesis at high-altitude (HA) may differ depending on ascent or descent, as well as on age. METHODS: Male subjects (37.9±12.0 SD y, n=33) were separated into a young (Y) group (29.6±5.73 SD y, n=18) and an older (O) one (47.9±9.83 SD y, n=15). All subjects were monitored by Holter electrocardiography while successively ascending (41.2±7.51 SD min) and descending (38.7±6.68 SD min) between 2950 and 5050 m as car passengers on a 25 km road in Northern Chile. Arrhythmic events (AE) ensued when the difference between two consecutive RR intervals exceeded 0.16 sec. RESULTS: From 311 AE registered, 29% occurred on ascent and 71% on descent, the sinusal type predominating in both age groups. AE incidence, RR interval duration, and heart rate variability (HRV) in the time domain (RMSSD) increased during descent, as compared to ascent, in the Y group (p<0.05), but not in the O one. Independently of age, AE incidence along descent associates with the time previously spent at 5050 m (p<0.001). CONCLUSIONS: Rapid transitions at HA favor arrhythmogenesis, the latter becoming evident particularly in the Y group on descent. Age-dependent changes of autonomic activity appear to be involved in arrhythmogenesis on transitions at HA.


Subject(s)
Altitude , Arrhythmias, Cardiac/etiology , Autonomic Nervous System/physiology , Hypoxia/physiopathology , Adult , Age Factors , Arrhythmias, Cardiac/physiopathology , Automobile Driving , Chile , Humans , Hypoxia/etiology , Male , Middle Aged
7.
Rev. chil. pediatr ; 60(2): 97-9, mar.-abr. 1989. ilus
Article in Spanish | LILACS | ID: lil-65950

ABSTRACT

Reportamos un caso de histiocitosis maligna en un niño de 2 años de edad. Las manifestaciones clínicas más importantes fueron fiebre, compromiso del estado general, adenopatías generalizadas y hepatoesplenomegalia. La biopsia ganglionar demostró proliferación de células de tipo histiocítico con marcadas atipias eritrofagocitosis y un patrón de infiltración de tipo sinusal. El compromiso hepático fue demostrado mediante biopsia hepática por punción. La evolución fue progresiva y fatal después de 6 meses de tratamiento quimioterápico


Subject(s)
Child, Preschool , Humans , Male , Histiocytic Sarcoma/pathology
SELECTION OF CITATIONS
SEARCH DETAIL