1.
Arch Pathol Lab Med ; 134(9): 1253-60, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20807043

ABSTRACT

CONTEXT: Intraosseous (IO) blood is frequently used to establish a blood chemistry profile in critically ill patients. Questions remain regarding the reliability of IO blood for laboratory analysis and established criteria regarding the amount of marrow/blood to waste before taking an IO sample are not available. OBJECTIVES: To evaluate IO-derived blood for routine laboratory blood tests needed in the care of critically ill patients and to determine the amount of marrow/blood to waste before drawing blood from the IO space for laboratory analysis. DESIGN: Blood samples were drawn from peripheral veins of 10 volunteers. Within 5 minutes, 2 IO blood samples were obtained; one following 2 mL of waste and another following 6 mL of waste. Samples were analyzed for complete blood count and chemistry profile. Values were analyzed using Pearson correlation coefficients. Levels of significance were determined using the t distribution. Mean values for the draws were calculated and compared, with the intravenous blood sample serving as a control for the IO samples. RESULTS: There was a significant correlation between intravenous and IO samples for red blood cell counts and hemoglobin and hematocrit levels but not for white blood cell counts and platelet counts. There was a significant correlation between intravenous and IO samples for glucose, blood urea nitrogen, creatinine, chloride, total protein, and albumin concentrations but not for sodium, potassium, CO(2), and calcium levels. CONCLUSIONS: When venous blood cannot be accessed, IO blood aspirate may serve as a reliable alternate, especially for hemoglobin and hematocrit levels and most analytes in a basic blood chemistry profile. Exceptions are CO(2) levels and platelet counts, which may be lower, and white blood cell counts, which may appear elevated.


Subject(s)
Blood Chemical Analysis/methods , Blood Specimen Collection/methods , Bone Marrow/blood supply , Hematologic Tests/methods , Adult , Female , Humans , Male , Middle Aged , Young Adult
2.
J Clin Pathol ; 63(6): 562-5, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20404008

ABSTRACT

Recently, a new FDA-cleared battery powered bone marrow biopsy system was developed to allow operators access to the bone marrow space quickly and efficiently. A pre-clinical evaluation of the device (OnControl, Vidacare Corporation, San Antonio, TX, USA) on anesthetized pigs was conducted, in addition to a clinical evaluation in hematology clinic patients requiring a bone marrow biopsy. Twenty-six samples were collected from the swine model. No cellular artifact or thermal damage was reported in any of the samples obtained. For the clinical evaluation of the device, 16 patients were recruited. Mean time from needle contact with skin to needle removal was 38.5 +/- 13.94 seconds. No complications were reported. In this study, the manual and powered samples were equivalent in specimen quality. In the patients evaluated, the device was safe, easy to use and the mean procedural time was significantly faster than previously reported with a manual technique.


Subject(s)
Biopsy, Needle/instrumentation , Bone Marrow Examination/instrumentation , Bone Marrow/pathology , Animals , Biopsy, Needle/methods , Bone Marrow Examination/methods , Equipment Design , Humans , Models, Animal , Sus scrofa