Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 126
Filter
1.
J Neurointerv Surg ; 2024 Aug 08.
Article in English | MEDLINE | ID: mdl-39122254

ABSTRACT

BACKGROUND: Sealing of the aneurysm neck with a Woven EndoBridge (WEB) device is recommended for disrupting the blood flow inside the aneurysm. This study investigates the relationship between WEB neck apposition and aneurysm occlusion rates. METHODS: Aneurysms treated with a WEB from March 2017 to May 2022 at a single center were included. WEB neck apposition (poor/good) and WEB protrusion (yes/no) were evaluated on post-detachment high resolution cone beam CT images. Angiographic occlusion was assessed with the Bicêtre Occlusion Scale score (BOSS). Univariate and multivariable analysis tested the association between neck apposition and occlusion rates. RESULTS: The study included 159 aneurysms in 141 patients (mean age 55.8±11.2 years; 64.2% women). Good neck apposition and protrusion were noted in 123 (77.4%) and 30 (18.9%) cases, respectively. Inter-rater agreements were good for neck apposition (κ=0.75) and protrusion (κ=0.78). Complete and adequate occlusion was achieved in 104 (65%) and 130 (82%) cases, respectively (median follow-up 18 months). Good neck apposition was a strong independent predictor for both adequate (adjusted OR (aOR)=5.9, 95% CI 2.4 to 14.9; P<0.001) and complete occlusion (aOR=7.1, 95% CI 3.0 to 18.1; P<0.001). Protrusion was more frequent in the adequate occlusion group versus the aneurysm recurrence group without reaching statistical significance (P=0.06), but was associated with more thromboembolic complications (9/30 (30%) vs 12/129 (9%); P<0.01). WEB shape modification was significantly greater in poor apposition cases (P=0.03). CONCLUSIONS: Achieving good neck apposition of the WEB strongly predicts aneurysm occlusion during follow-up. WEB protrusion should be minimized due to the increase in thromboembolic risk with limited impact on aneurysm occlusion.

2.
J Neurointerv Surg ; 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38991733

ABSTRACT

BACKGROUND: The Woven EndoBridge (WEB) device is designed to treat wide-necked bifurcation aneurysms. The WEB 17 is the latest iteration and can be delivered through a 0.017″ microcatheter. The CLEVER study demonstrated that WEB 17 is safe and effective for providing protection against bleeding or rebleeding at 1 month and 1 year. OBJECTIVE: To evaluate angiographic stability at 1 year. METHODS: The CLEVER study was a prospective multicenter study conducted in 17 European centers, involved 163 subjects, comprising 60 ruptured and 103 unruptured aneurysms. Independent assessment of 1-year follow-up imaging was incorporated into the study design. RESULTS: Aneurysm diameters ranged from 2.0 to 9.2 mm, with 95.7% being broad-based (dome-to-neck ratio <2). Follow-up imaging at 1 year was completed for 146 out of 163 subjects (89.6%) and evaluated by an independent core laboratory. The primary efficacy endpoint of adequate occlusion without re-treatment at 1 year was achieved for 120 (82.2%) of all subjects. At 1 year, the adequate occlusion rate was 86.5% for ruptured aneurysms (73.1% complete occlusion) and 82.4% for unruptured aneurysms (57.1% complete occlusion). The overall re-treatment rate at 1 year was 2.6% (4/152), with 3.1% (3/97) for unruptured aneurysms and 1.8% (1/55) for ruptured aneurysms CONCLUSION: Delivery of the WEB 17 via 0.017 inch catheters represents a significant evolution of the WEB design. The results of CLEVER presented here demonstrate that it maintains the same efficacy as previous generations of WEB.

3.
J Neurointerv Surg ; 2024 Jun 02.
Article in English | MEDLINE | ID: mdl-38830670

ABSTRACT

BACKGROUND: Multiple studies and meta-analyses have described the technical and clinical outcomes in large cohorts of aneurysm patients treated with flow diverters (FDs). Variations in evaluation methodology complicate making comparisons among studies, hinder understanding of the device behavior, and pose an obstacle in the assessment of further advances in FD therapy. METHODS: A multidisciplinary panel of neurointerventionalists, imaging experts, and neuroradiologists convened with the goal of establishing consensus recommendations for the standardization of image analyses in FD studies. RESULTS: A standardized methodology is proposed for evaluating and reporting radiological outcomes of FD treatment of intracranial aneurysms. The recommendations include general imaging considerations for clinical studies and evaluations of longitudinal changes, such as neointimal lining and stenosis. They cover standards for classification of aneurysm location, morphology, measurements, as well as the assessment of aneurysm occlusion, wall apposition, and neck coverage. These reporting standards further define four specific braid deformation patterns: foreshortening, fish-mouthing, braid bump deformation, and braid collapse, collectively termed 'F2B2'. CONCLUSIONS: When widely applied, standardization of methods of measuring and reporting outcomes will help to harmonize the assessment of treatment outcomes in clinical studies, help facilitate communication of results among specialists, and help enable research and development to focus on specific aspects of FD techniques and technology.

4.
J Neurointerv Surg ; 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38914459

ABSTRACT

BACKGROUND: Flow diverting stents (FDS) have transformed the treatment of intracranial aneurysms; however, their metallic structure associated with their intra-luminal positioning hamper angiographic and clinical outcomes. Therefore, there is a need to develop FDS with optimized surfaces that reduce thrombogenicity while promoting the healing process and endothelialization. METHODS: P8RI, a peptide mimicking the CD31 protein, was previously developed and grafted onto Silk Vista (SV) FDS. P8RI-SV and bare-SV were used in vitro in a blood loop model to test their hemocompatibility using human whole blood and in vivo using the rabbit elastase model for optical coherence tomography (OCT) comparisons of neointimal formation at day 5 and day 28. RESULTS: After blood loop incubation, P8RI-SV showed significant reduction in fibrin binding (p=0.004) and platelet adhesion (p=0.041) compared with bare-SV. Similarly, derivative markers measured in blood, thromboxane B2 (platelet activation) and Thrombin-Antithrombin III complexes (coagulation activation), were also significantly reduced in the P8RI-SV group (both p=0.002). In vivo, complete or near-complete occlusion was reached in all aneurysms (n=6) at day 28. Excellent rate of stent-coverage ratio was obtained at day 5 (89.3% (79.1%-98.7%)) comparable to the observation at day 28 (91.8% (79.1%-100%); p=0.44). These rates were significantly higher compared with bare-SV at day 5 (77.8% (58.3%-86.8%); p<0.001) and at day 28 (67.7% (52.6%-88.9%); p<0.0001). CONCLUSION: In vitro results confirm enhanced hemocompatibility with a significant anti-thrombotic effect of the P8RI-SV. In vivo results provide evidence of rapid neo-intimal growth reaching near-complete tissue healing as early as day 5 in a rabbit model.

5.
N Engl J Med ; 390(18): 1677-1689, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38718358

ABSTRACT

BACKGROUND: The use of thrombectomy in patients with acute stroke and a large infarct of unrestricted size has not been well studied. METHODS: We assigned, in a 1:1 ratio, patients with proximal cerebral vessel occlusion in the anterior circulation and a large infarct (as defined by an Alberta Stroke Program Early Computed Tomographic Score of ≤5; values range from 0 to 10) detected on magnetic resonance imaging or computed tomography within 6.5 hours after symptom onset to undergo endovascular thrombectomy and receive medical care (thrombectomy group) or to receive medical care alone (control group). The primary outcome was the score on the modified Rankin scale at 90 days (scores range from 0 to 6, with higher scores indicating greater disability). The primary safety outcome was death from any cause at 90 days, and an ancillary safety outcome was symptomatic intracerebral hemorrhage. RESULTS: A total of 333 patients were assigned to either the thrombectomy group (166 patients) or the control group (167 patients); 9 were excluded from the analysis because of consent withdrawal or legal reasons. The trial was stopped early because results of similar trials favored thrombectomy. Approximately 35% of the patients received thrombolysis therapy. The median modified Rankin scale score at 90 days was 4 in the thrombectomy group and 6 in the control group (generalized odds ratio, 1.63; 95% confidence interval [CI], 1.29 to 2.06; P<0.001). Death from any cause at 90 days occurred in 36.1% of the patients in the thrombectomy group and in 55.5% of those in the control group (adjusted relative risk, 0.65; 95% CI, 0.50 to 0.84), and the percentage of patients with symptomatic intracerebral hemorrhage was 9.6% and 5.7%, respectively (adjusted relative risk, 1.73; 95% CI, 0.78 to 4.68). Eleven procedure-related complications occurred in the thrombectomy group. CONCLUSIONS: In patients with acute stroke and a large infarct of unrestricted size, thrombectomy plus medical care resulted in better functional outcomes and lower mortality than medical care alone but led to a higher incidence of symptomatic intracerebral hemorrhage. (Funded by Montpellier University Hospital; LASTE ClinicalTrials.gov number, NCT03811769.).


Subject(s)
Infarction, Anterior Cerebral Artery , Stroke , Thrombectomy , Thrombolytic Therapy , Aged , Aged, 80 and over , Female , Humans , Male , Cerebral Hemorrhage/etiology , Combined Modality Therapy , Endovascular Procedures , Magnetic Resonance Imaging , Stroke/diagnostic imaging , Stroke/etiology , Stroke/therapy , Thrombolytic Therapy/adverse effects , Thrombolytic Therapy/methods , Tomography, X-Ray Computed , Brain Infarction/diagnostic imaging , Brain Infarction/etiology , Brain Infarction/therapy , Acute Disease , Cerebral Arteries/diagnostic imaging , Cerebral Arteries/surgery , Cerebral Arterial Diseases/complications , Cerebral Arterial Diseases/diagnostic imaging , Cerebral Arterial Diseases/pathology , Cerebral Arterial Diseases/surgery , Infarction, Anterior Cerebral Artery/diagnostic imaging , Infarction, Anterior Cerebral Artery/pathology , Infarction, Anterior Cerebral Artery/surgery
6.
Res Pract Thromb Haemost ; 8(3): 102373, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38617048

ABSTRACT

Background: Electrochemical impedance spectroscopy can determine characteristics such as cell density, size, and shape. The development of an electrical impedance-based medical device to estimate acute ischemic stroke (AIS) clot characteristics could improve stroke patient outcomes by informing clinical decision making. Objectives: To assess how well electrical impedance combined with machine learning identified red blood cell (RBC)-rich composition of AIS clots ex vivo, which is associated with a successfully modified first-pass effect. Methods: A total of 253 clots from 231 patients who underwent thrombectomy in 5 hospitals in France, Japan, Serbia, and Spain between February 2021 and October 2023 were analyzed in the Clotbase International Registry. Electrical impedance measurements were taken following clot retrieval by thrombectomy, followed by Martius Scarlet Blue staining. The clot components were quantified via Orbit Image Analysis, and RBC percentages were correlated with the RBC estimations made by the electrical impedance machine learning model. Results: Quantification by Martius Scarlet Blue staining identified RBCs as the major component in clots (RBCs, 37.6%; white blood cells, 5.7%; fibrin, 25.5%; platelets/other, 30.3%; and collagen, 1%). The impedance-based RBC estimation correlated well with the RBC content determined by histology, with a slope of 0.9 and Spearman's correlation of r = 0.7. Clots removed in 1 pass were significantly richer in RBCs and clots with successful recanalization in 1 pass (modified first-pass effect) were richer in RBCs as assessed using histology and impedance signature. Conclusion: Electrical impedance estimations of RBC content in AIS clots are consistent with histologic findings and may have potential for clinically relevant parameters.

7.
J Neurointerv Surg ; 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38538055

ABSTRACT

BACKGROUND: Retrospective studies suggest the superiority of first-line contact aspiration (CA) thrombectomy over stent-retriever (SR) in basilar artery occlusions (BAO). We aimed to investigate the impact of first-line mechanical thrombectomy per the occlusion level, considering differences in stroke etiology prevalence between proximal and distal BAO. METHODS: A retrospective, multicentric analysis of the Endovascular Treatment in Ischemic Stroke Registry (ETIS) included consecutive BAO patients treated from January 2016 to May 2022. Patients were categorized into SR (±aspiration) and CA alone groups. Occlusion levels were determined through digital subtraction angiography. Favorable clinical outcome was defined as 90-day modified Rankin Scale (mRS) 0-3. RESULTS: A total of 380 patients were analyzed (251 CA alone, 129 SR±aspiration). Globally, first-line SR showed lower recanalization rates (89.1% vs 94.8%, OR=0.29, 95% CI 0.16 to 0.53; p<0.001) and worse clinical outcomes (mRS 0-3: 46.0% vs 52.2%, OR=0.62, 95% CI 0.44 to 0.87; p=0.006) compared with CA. In proximal occlusions, SR was significantly associated with poorer clinical outcomes (mRS 0-3: 20.9% vs 37.1%; OR=0.40, 95% CI 0.19 to 0.83; p=0.014) despite similar recanalization rates. Conversely, in distal occlusions there was no difference in clinical outcomes although recanalization rates were higher with CA (modified Thrombolysis in Cerebral Infarction score (mTICI 2b/3): 97.7% vs 91.7%; OR=0.17, 95% CI 0.05 to 0.66; p=0.01). CONCLUSIONS: In our BAO population, CA demonstrated better angiographic outcomes in middle and distal occlusions and better clinical outcomes in proximal occlusions. This translated into better angiographic and clinical results in the global study population. Clinical results were particularly influenced by the negative impact of SR on 90-day mRS, independently of recanalization rates in proximal BAO.

8.
J Neurointerv Surg ; 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38538057

ABSTRACT

BACKGROUND: Mechanical thrombectomy (MT) has become a standard treatment for acute ischemic strokes (AIS). However, MT failure occurs in approximately 10-30% of cases, leading to severe repercussions (with mortality rates up to 40% according to observational data). Among the available rescue techniques, rescue intracranial stenting (RIS) appears as a promising option. OBJECTIVE: This trial is poised to demonstrate the superiority of RIS in addition to the best medical treatment (BMT) in comparison with BMT alone, in improving the functional outcomes at 3 months for patients experiencing an AIS due to a large vessel occlusion refractory to MT (rLVO). METHODS: Permanent Intracranial STenting for Acute Refractory large vessel occlusions (PISTAR) is a multicenter prospective randomized open, blinded endpoint trial conducted across 11 French University hospitals. Adult patients (≥18 years) with an acute intracranial occlusion refractory to standard MT techniques will be randomized 1:1 during the procedure to receive either RIS+BMT (intervention arm) or BMT alone (control arm). RESULTS: The primary outcome is the rate of good clinical outcome at 3 months defined as a modified Rankin Scale score ≤2 and evaluated by an independent assessor blinded to the randomization arm. Secondary outcomes include hemorrhagic complications, all adverse events, and death. The number of patients to be included is 346. Two interim analyses are planned with predefined stopping rules. CONCLUSION: The PISTAR trial is the first randomized controlled trial focusing on the benefit of RIS in rLVOs. If positive, this study will open new insights into the management of AIS. TRIAL REGISTRATION NUMBER: NCT06071091.

10.
Int J Stroke ; 19(3): 367-372, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37740419

ABSTRACT

RATIONALE: Mechanical thrombectomy (MT) associated with the best medical treatment (BMT) has recently shown efficacy for the management of acute ischemic stroke (AIS) secondary to a large vessel occlusion. However, evidence is lacking regarding the benefit of MT for more distal occlusions. AIM: To evaluate the efficacy in terms of good clinical outcome at 3 months of MT associated with the BMT over the BMT alone in AIS related to a distal occlusion. METHODS: The DISCOUNT trial is a multicenter open-label randomized controlled trial involving French University hospitals. Adult patients (⩾18 years) with an AIS involving the anterior or posterior circulation secondary to a distal vessel occlusion within 6 h of symptom onset or within 24 h if no hyperintense signal on fluid attenuation inversion recovery acquisition will be randomized 1:1 to receive either MT associated with the BMT (experimental group) or BMT alone (control group). The number of patients to be included is 488. STUDY OUTCOMES: The primary outcome is the rate of good clinical outcome at 3 months defined as a modified Rankin scale (mRS) ⩽2 and evaluated by an independent assessor blinded to the intervention arm. Secondary outcomes include recanalization of the occluded vessel within 48 h, angiographic reperfusion in the experimental group, 3-month excellent clinical outcome (mRS ⩽ 1), all adverse events, and death. A cost utility analysis will estimate the incremental cost per quality-adjusted life year (QALY) gained. DISCUSSION: If positive, this study will open new insights in the management of AISs. TRIAL REGISTRATION: ClinicalTrials.gov: NCT05030142 registered on 1 September 2021.


Subject(s)
Arterial Occlusive Diseases , Brain Ischemia , Ischemic Stroke , Stroke , Adult , Humans , Ischemic Stroke/complications , Stroke/drug therapy , Treatment Outcome , Thrombectomy , Arterial Occlusive Diseases/therapy , Arterial Occlusive Diseases/complications , Brain Ischemia/therapy , Brain Ischemia/complications
11.
Neurosurgery ; 94(1): 183-192, 2024 01 01.
Article in English | MEDLINE | ID: mdl-37728333

ABSTRACT

BACKGROUND AND OBJECTIVES: The Woven EndoBridge (WEB) device has been increasingly used to treat wide-neck aneurysms showing a safe and effective profile, but a relatively high number of thromboembolic events (TEEs) have been reported with such treatment. We aimed to evaluate the incidence and management of TEEs and possible predictive factors related to WEB embolization of ruptured and unruptured intracranial aneurysms. METHODS: A single-center database with consecutive aneurysms treated with a WEB device between July 2012 and May 2022 was reviewed for intraoperative and delayed TEEs. Univariate and multivariable analyses were used to determine factors associated with TEEs. RESULTS: A total of 266 independent aneurysms were treated with WEB devices in 245 patients (mean age 55.78 ± 11.64 years, 169 (63.5%) females, 80 (30%) ruptured). The overall rate of TEEs is 13% (35/266), including 8.7% intraoperative. Symptomatic TEEs with clinical sequelae at a 3-month follow-up are reported to be 2.6% (7/266) with no TEE-related mortality. Both the replacement of a WEB device during the procedure (adjusted odds ratio = 2.61, 95% CI 1.24-5.49; P = .01) and ruptured aneurysms (adjusted odds ratio = 2.74, 95% CI 1.31-5.7; P = .007) were independent predictors of TEEs. A case-by-case management of intraprocedural TEE is also presented; tirofiban was successfully used in most cases of this cohort. CONCLUSION: In this study, we demonstrated that ruptured aneurysms and WEB device replacement during the procedure were independent predictive factors for TEEs. As a result, making the correct choice of WEB is crucial for improving treatment outcomes. Moreover, with proper medical management of TEEs, minimal morbidity and no mortality could be achieved, which reinforces the safety of the technique.


Subject(s)
Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Thromboembolism , Female , Humans , Adult , Middle Aged , Aged , Male , Incidence , Retrospective Studies , Endovascular Procedures/methods , Treatment Outcome , Intracranial Aneurysm/epidemiology , Intracranial Aneurysm/therapy , Intracranial Aneurysm/complications , Aneurysm, Ruptured/epidemiology , Aneurysm, Ruptured/therapy , Aneurysm, Ruptured/complications , Thromboembolism/epidemiology , Thromboembolism/etiology , Embolization, Therapeutic/adverse effects
12.
J Neuroradiol ; 51(2): 220-223, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37652262

ABSTRACT

BACKGROUND: The Contour Embolization Device (CED) is typically assessed using coiling angiographic outcomes. However, these scales do not address device-specific problematics. We evaluated the usability of the Bicêtre occlusion scale (BOS) with the CED. RESULTS: BOS scores can be analyzed as BOSS 0 = no residual flow, BOSS 1 = residual flow inside the CED but with complete neck-sealing, BOSS 2 = neck-remnant, BOSS 3 = aneurysm-remnant, BOSS 1 + 3 = contrast filling inside the device and aneurysmal sac without complete neck-sealing. CONCLUSION: BOS usage should be encouraged as it provides a more comprehensive assessment of the mechanism of CED occlusion, especially considering the potential prognostic value of the neck sealing assessment.


Subject(s)
Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Cerebral Angiography , Treatment Outcome , Retrospective Studies , Stents
13.
Stroke ; 55(2): 376-384, 2024 02.
Article in English | MEDLINE | ID: mdl-38126181

ABSTRACT

BACKGROUND: The aim of this study was to report the results of a subgroup analysis of the ASTER2 trial (Effect of Thrombectomy With Combined Contact Aspiration and Stent Retriever vs Stent Retriever Alone on Revascularization in Patients With Acute Ischemic Stroke and Large Vessel Occlusion) comparing the safety and efficacy of the combined technique (CoT) and stent retriever as a first-line approach in internal carotid artery (ICA) terminus±M1-middle cerebral artery (M1-MCA) and isolated M1-MCA occlusions. METHODS: Patients enrolled in the ASTER2 trial with ICA terminus±M1-MCA and isolated M1-MCA occlusions were included in this subgroup analysis. The effect of first-line CoT versus stent retriever according to the occlusion site was assessed on angiographic (first-pass effect, expanded Treatment in Cerebral Infarction score ≥2b50, and expanded Treatment in Cerebral Infarction score ≥2c grades at the end of the first-line strategy and at the end of the procedure) and clinicoradiological outcomes (24-hour National Institutes of Health Stroke Scale, ECASS-III [European Cooperative Acute Stroke Study] grades, and 3-month modified Rankin Scale). RESULTS: Three hundred sixty-two patients were included in the postsubgroup analysis according to the occlusion site: 299 were treated for isolated M1-MCA occlusion (150 with first-line CoT) and 63 were treated for ICA terminus±M1-MCA occlusion (30 with first-line CoT). Expanded Treatment in Cerebral Infarction score ≥2b50 (odds ratio, 11.83 [95% CI, 2.32-60.12]) and expanded Treatment in Cerebral Infarction score ≥2c (odds ratio, 4.09 [95% CI, 1.39-11.94]) were significantly higher in first-line CoT compared with first-line stent retriever in patients with ICA terminus±M1-MCA occlusion but not in patients with isolated M1-MCA. CONCLUSIONS: First-line CoT was associated with higher reperfusion grades in patients with ICA terminus±M1-MCA at the end of the procedure. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03290885.


Subject(s)
Arterial Occlusive Diseases , Brain Ischemia , Carotid Artery Diseases , Endovascular Procedures , Ischemic Stroke , Stroke , Humans , Arterial Occlusive Diseases/complications , Brain Ischemia/surgery , Carotid Artery Diseases/diagnostic imaging , Carotid Artery Diseases/surgery , Carotid Artery Diseases/complications , Carotid Artery, Internal/diagnostic imaging , Carotid Artery, Internal/surgery , Endovascular Procedures/methods , Infarction, Middle Cerebral Artery/diagnostic imaging , Infarction, Middle Cerebral Artery/surgery , Infarction, Middle Cerebral Artery/complications , Ischemic Stroke/complications , Middle Cerebral Artery/surgery , Stents , Stroke/therapy , Thrombectomy/methods , Treatment Outcome
14.
J Neurointerv Surg ; 2023 Dec 02.
Article in English | MEDLINE | ID: mdl-38050090

ABSTRACT

BACKGROUND: Challenges to revascularization of large vessel occlusions (LVOs) persist. Current stent retrievers have limited effectiveness for removing organized thrombi. The NeVa device is a novel stent retriever designed to capture organized thrombi within the scaffold during retrieval. OBJECTIVE: To evaluate the safety and effectiveness of revascularization of acute LVOs with the NeVa device. METHODS: Prospective, international, multicenter, single-arm, Investigational Device Exemption study to evaluate the performance of the NeVa device in recanalizing LVOs including internal carotid artery, M1/M2 middle cerebral artery, and vertebrobasilar arteries, within 8 hours of onset. Primary endpoint was rate of expanded Treatment in Cerebral Ischemia (eTICI) score 2b-3 within 3 NeVa passes, tested for non-inferiority against a performance goal of 72% with a -10% margin. Additional endpoints included first pass success and 90-day modified Rankin Scale (mRS) score 0-2. Primary composite safety endpoint was 90-day mortality and/or 24-hour symptomatic intracranial hemorrhage (sICH). RESULTS: From April 2021 to April 2022, 139 subjects were enrolled at 25 centers. Median National Institutes of Health Stroke Scale (NIHSS) score was 16 (IQR 12-20). In the primary analysis population (n=107), eTICI 2b-3 within 3 NeVa passes occurred in 90.7% (97/107; non-inferiority P<0.0001; post hoc superiority P<0.0001). First pass eTICI 2b-3 was observed in 73.8% (79/107), with first pass eTICI 2b67-3 in 69.2% (74/107) and eTICI 2c-3 in 48.6% (52/107). Median number of passes was 1 (IQR 1-2). Final eTICI 2b-3 rate was 99.1% (106/107); final eTICI 2b67-3 rate was 91.6% (98/107); final eTICI 2c-3 rate was 72.9% (78/107). Good outcome (90-day mRS score 0-2) was seen in 65.1% (69/106). Mortality was 9.4% (13/138) with sICH in 5.0% (7/139). CONCLUSIONS: The NeVa device is highly effective and safe for revascularization of LVO strokes and demonstrates superior first pass success compared with a predicate performance goal. TRIAL REGISTRATION NUMBER: NCT04514562.

15.
J Neurointerv Surg ; 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37914392

ABSTRACT

BACKGROUND: Intrasaccular flow disruption is an endovascular approach for the treatment of wide-neck aneurysms and, more specifically, wide-neck bifurcation aneurysms, which are challenging to treat with previously developed technologies. The Woven EndoBridge (WEB) device has demonstrated its efficacy and safety, for both unruptured and ruptured aneurysms. METHODS: The CLEVER study was an observational, multicenter, prospective study conducted in 17 European investigational sites using the WEB 17 device, for the treatment of ruptured and unruptured aneurysms. The study objective was to provide safety and efficacy data on the WEB 17 device in the treatment of wide-neck bifurcation aneurysms. Imaging results were assessed independently by a Corelab and adverse events adjudicated by a Clinical Event Adjudicator. This analysis reports procedural results and safety at 30 days and 12 months. RESULTS: A total of 163 patients (mean age 58.1 years; 68.1% women) with 103 unruptured aneurysms and 60 ruptured aneurysms were enrolled. Most aneurysms were located on the anterior communicating artery (ACom) (37.4%) or the middle cerebral artery (MCA) bifurcation (30.1%). Aneurysm widths ranged from 2.0-9.2 mm, and the mean sac width was 5.0 mm. The WEB procedure was successfully completed in 163 patients (100%). At the 12-month follow-up, major stroke events occurred in 3 of 163 patients (1.8%), and no device-related mortality was observed. CONCLUSION: Endovascular treatment of ruptured and unruptured wide-neck bifurcation aneurysms using WEB 17 is safe, with a low complication rate and no device-related mortality. In particular, none of the ruptured aneurysms bled again up to 1 year of follow-up. TRIAL REGISTRATION NUMBER: NCT03844334.

16.
J Neuroradiol ; 2023 Oct 17.
Article in English | MEDLINE | ID: mdl-37858720

ABSTRACT

BACKGROUND: The Low profile visualized intraluminal support (LVIS)/LVIS Jr is a self-expanding braiding stent for the treatment of intracranial aneurysm. This study is to determine the safety and effectiveness of the LVIS/LVIS Jr for the treatment of intracranial aneurysms in a real-world setting. METHODS: This prospective, observational, multicenter study enrolled patients with unruptured, ruptured and recanalized intracranial aneurysms treated with the LVIS stents, between February 2018 to December 2019. Primary endpoint was the cumulative morbidity and mortality rate (CMMR) assessed at 12 months follow-up (FU). RESULTS: A total of 130 patients were included (62.3 % women, mean age 55.9 ± 11.4) on an intention-to-treat basis. Four patients (3.1 %) had 2 target aneurysms; 134 total aneurysms were treated. The aneurysms were mainly located on the middle cerebral artery (41/134; 30.6 %) and the anterior communicating artery (31/134; 23.1 %). The CMMR at 1 year linked to the procedure and/or device was 4.6 % (6/130). The overall mortality was 1.5 % (2/130), none of these deaths adjudged as being linked to the procedure and/or device. All aneurysms (134/134, 100 %) were successfully treated with LVIS stent and/or other devices. At a mean FU of 16.8 months post-procedure, complete/nearly complete occlusion was achieved in 112 aneurysms (92.6 %), and only 3 patients (2.5 %) required aneurysm retreatment. CONCLUSION: This study provides evidence that the LVIS/LVIS Jr devices are safe and effective in the treatment of complex intracranial aneurysms, with very high rates of adequate occlusion at FU. These angiographic results are stable over time with an acceptable complication rate. TRIAL REGISTRATION: ClinicalTrial.gov under NCT03553771.

18.
J Neurol ; 270(11): 5493-5501, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37515733

ABSTRACT

BACKGROUND: Hemorrhagic transformation (HT) is an uncommon complication of posterior circulation acute ischemic stroke (PCS) compared to anterior circulation stroke. Nevertheless, it remains a major concern especially following reperfusion therapy. This study aimed at identifying potential predictive factors associated with HT in PCS. METHODS: Consecutive patients, from a multicenter cohort, with PCS treated by IVT or EVT or the combination of both, were included from December 2015 to May 2019. The European Cooperative Acute Stroke Study criteria was used to identify HT. Potential risk factors were analyzed using univariate and multivariable testing models. RESULTS: A total of 96 patients were included in our study. Median age was 66 (57-83) years, 54 patients (56%) were male and median baseline NIHSS was 8 (4-14). 77 patients (80%) received IVT and 54 patients (56%) benefited from EVT. HT occurred in 19 patients (20%), while sHT occurred in 3 patients (3%). HT was found to be associated with poor functional status at 3 months in univariate analysis (p = 0.0084). Multivariable analysis confirmed that higher baseline NIHSS (OR 1.1008; 95% CI [1.0216-1.1862]; p = 0.0117) and lobar topography of ischemia (OR 4.4275; 95% CI [1.3732-14.2753]; p = 0.0127) were independent predictors of the occurrence of HT. DISCUSSION: HT is associated with increased morbidity in patients with PCS; higher NIHSS and lobar ischemia were independent predictors of HT in our population. Easy-to-use predictive markers may help to tailor therapeutic management of patients with PCS.

19.
J Neuroradiol ; 50(5): 518-522, 2023 Sep.
Article in English | MEDLINE | ID: mdl-36868371

ABSTRACT

BACKGROUND: Safety and efficacy of the WEB (Woven EndoBridge) device have been extensively evaluated in several good clinical practice studies. Nonetheless, the WEB had several structural evolutions overtime up to the fifth generation WEB device (WEB17). Here, we tried to understand how this may have modified our practices and enlarged our indications for its use. METHODS: We retrospectively analyzed data from all patients with aneurysms treated (or intended to be treated) with a WEB at our institution between July 2012 and February 2022. The time frame was split in two periods: before and after the arrival of the WEB17 in our center (February 2017). RESULTS: 252 patients with 276 wide-necked aneurysms were included; 78 aneurysms (28.2%) were ruptured. Successful embolization with a WEB device was achieved in 263/276 aneurysms (95.3%). With the availability of WEB17, treated aneurysms were significantly smaller (8.2 mm versus 5.9 mm, p<0.001) and off-label location significantly increased (4.4% versus 17.3%, p = 0.02) with an increase of sidewall aneurysm (4.4% versus 11.6%, p = 0.06). Also, WEB were more significantly oversized (1.05 versus 1.11, p<0.01). Adequate and complete occlusion rates increased constantly during the two periods (54.8% versus 67.5%, p = 0.08 and 74.2% versus 83.7%, p = 0.10, respectively). The proportion of ruptured aneurysms slightly increased between the two periods (24.6% versus 29.5%, p = 0.44). CONCLUSIONS: Over the first decade of its availability, the WEB device usage shifted towards smaller aneurysms and broader indications, including ruptured aneurysms. The oversizing strategy also became the standard of practice for WEB deployment in our institution.


Subject(s)
Aneurysm, Ruptured , Embolization, Therapeutic , Endovascular Procedures , Intracranial Aneurysm , Humans , Treatment Outcome , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/therapy , Retrospective Studies , Aneurysm, Ruptured/diagnostic imaging , Aneurysm, Ruptured/therapy
20.
Stroke ; 54(1): 124-131, 2023 01.
Article in English | MEDLINE | ID: mdl-36542074

ABSTRACT

BACKGROUND: Management of extracranial internal carotid artery steno-occlusive lesion during endovascular therapy remains debated. Stent occlusion within 24 hours of endovascular therapy is a frequent event after acute carotid artery stenting, and we currently lack large population results. We investigated the incidence, predictors, and clinical impact of stent occlusion after acute carotid artery stenting in current clinical practice. METHODS: Patients treated by endovascular therapy with acute carotid artery stenting between 2015 and 2019 in 5 large-volume endovascular-capable centers were retrospectively analyzed. Patients were separated in 2 groups according to the stent patency at 24 hours after carotid artery stenting. We compared baseline characteristics, treatment modalities, and clinical outcome depending on 24-hour stent patency. Primary end point was favorable outcome, defined as a modified Rankin Scale score 0-2 at 3 months. RESULTS: A stent occlusion was observed in 47/225 patients (20.9%). Patients with stent patency had a lower baseline National Institutes of Health Stroke Scale (median [interquartile range]: 13 [7-17] versus 18 [12-21]) and had more often stroke of atherothrombotic origin (77.0% versus 53.2%). A higher stent patency rate was found for patients treated with P2Y12 antagonists at the acute phase (odds ratio [OR]' 2.95 [95% CI' 1.10-7.91]; P=0.026) and treated with angioplasty (OR' 2.42 [95% CI' 1.24-4.67]; P=0.008). A better intracranial angiographic reperfusion was observed in patients with 24-hour stent patency compared with patients without stent patency (OR' 8.38 [95% CI' 3.07-22.78]; P<0.001). Patients with a stent patency at 24 hours had a higher chance of favorable outcome (OR' 3.29 [95% CI, 1.66-6.52]; P<0.001) and a lower risk of death (OR' 0.32 [95% CI, 0.13-0.76]; P=0.009). CONCLUSIONS: One out of 5 patients treated with carotid artery stenting during endovascular therapy presented a stent occlusion within 24 hours. This event was associated with worse functional outcome. Stroke etiology, P2Y12 antagonist administration, quality of intracranial reperfusion, and angioplasty were associated with 24-hour stent patency.


Subject(s)
Carotid Stenosis , Endovascular Procedures , Stroke , Humans , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/surgery , Retrospective Studies , Stents/adverse effects , Endovascular Procedures/methods , Treatment Outcome , Thrombectomy/methods , Carotid Arteries , Stroke/diagnostic imaging , Stroke/surgery , Stroke/etiology
SELECTION OF CITATIONS
SEARCH DETAIL