PLoS One ; 15(9): e0238385, 2020.
Article in English | MEDLINE | ID: mdl-32936810

ABSTRACT

A lack of replicable test systems that realistically simulate hot water premise plumbing conditions at the laboratory-scale is an obstacle to identifying key factors that support growth of opportunistic pathogens (OPs) and opportunities to stem disease transmission. Here we developed the convectively-mixed pipe reactor (CMPR) as a simple reproducible system, consisting of off-the-shelf plumbing materials, that self-mixes through natural convective currents and enables testing of multiple, replicated, and realistic premise plumbing conditions in parallel. A 10-week validation study was conducted, comparing three pipe materials (PVC, PVC-copper, and PVC-iron; n = 18 each) to stagnant control pipes without convective mixing (n = 3 each). Replicate CMPRs were found to yield consistent water chemistry as a function of pipe material, with differences becoming less discernable by week 9. Temperature, an overarching factor known to control OP growth, was consistently maintained across all 54 CMPRs, with a coefficient of variation <2%. Dissolved oxygen (DO) remained lower in PVC-iron (1.96 ± 0.29 mg/L) than in PVC (5.71 ± 0.22 mg/L) or PVC-copper (5.90 ± 0.38 mg/L) CMPRs as expected due to corrosion. Further, DO in PVC-iron CMPRs was 33% of that observed in corresponding stagnant pipes (6.03 ± 0.33 mg/L), demonstrating the important role of internal convective mixing in stimulating corrosion and microbiological respiration. 16S rRNA gene amplicon sequencing indicated that both bulk water (Padonis = 0.001, R2 = 0.222, Pbetadis = 0.785) and biofilm (Padonis = 0.001, R2 = 0.119, Pbetadis = 0.827) microbial communities differed between CMPR versus stagnant pipes, consistent with creation of a distinct ecological niche. Overall, CMPRs can provide a more realistic simulation of certain aspects of premise plumbing than reactors commonly applied in prior research, at a fraction of the cost, space, and water demand of large pilot-scale rigs.


Subject(s)
Drinking Water/adverse effects , Drinking Water/microbiology , Sanitary Engineering/instrumentation , Water Microbiology , Biofilms/growth & development , Chemical Phenomena , Copper/chemistry , Equipment Design , Humans , Iron/chemistry , Microbiota/genetics , Models, Biological , Opportunistic Infections/etiology , Opportunistic Infections/microbiology , Polyvinyl Chloride/chemistry , RNA, Ribosomal, 16S/genetics , Temperature , Water Supply
SELECTION OF CITATIONS
SEARCH DETAIL