Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 156
Filter
1.
Laryngorhinootologie ; 2024 Jun 06.
Article in German | MEDLINE | ID: mdl-38843816

ABSTRACT

BACKGROUND: Tinnitus is one of the most common otologic comorbidities, particularly in older patients with severe hearing loss or deafness. Cochlear implants (CI) have been used for hearing rehabilitation more and more successfully in elderly patients and CI treatment is performed in Germany without an age limit. The aim of this follow-up study was to assess the tinnitus burden in the long-term follow-up of elderly patients with hearing rehabilitation using CI. MATERIAL AND METHODS: This prospective longitudinal study included 15 patients between 72 and 92 years of age with preoperative tinnitus who had been treated unilaterally with a CI for the first time about six years ago. Monosyllabic speech understanding and tinnitus burden were assessed using the Mini-Tinnitus Questionnaire. The results were compared with our previous study 24, focusing on the first six months. RESULTS: Six years postoperatively, there was a nonsignificant increase in monosyllabic understanding to 61.7 ± 26.3%, compared with the results six months postoperatively (p = 0.069). The burden of tinnitus showed a stable low mean of 3.9 ± 3.6 points six years postoperatively, compared with the six-month control (p = 0.689) and significantly reduced compared to the preoperative status with 6.9 ± 6.5 points (p = 0.016). CONCLUSION: Hearing rehabilitation by using CI leads to a stable improvement of monosyllabic discrimination in elderly people as well as to a stable reduction of tinnitus burden over years.

2.
BMC Med Imaging ; 24(1): 145, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38872126

ABSTRACT

BACKGROUND: To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery. METHODS: This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same. Two radiologists independently evaluated following criteria on 5-point Likert scales: osseous spiral lamina, inner and outer cochlear wall, semi-circular canals, mastoid trabecular structure, overall image quality, metal and motion artefacts, depiction of intracochlear electrode position and visualisation of single electrode contacts. Effective radiation dose was assessed. RESULTS: Seventy-five patients (females, n = 39 [52.0%], mean age, 55.8 ± 16.5 years) were scanned with 96-kV (n = 32, 42.7%) and 120-kV (n = 43, 57.3%) protocols including CI models from three vendors (vendor A n = 7; vendor B n = 43; vendor C n = 25). Overall image quality, depiction of anatomical structures, and electrode position were rated significantly better in 120-kV images compared to 96-kV (all p < = 0.018). Anatomical structures and electrode position were rated significantly better in 120-kV CBCT for CI models from vendor A and C, while 120-kV did not provide improved image quality in CI models from vendor B. Radiation doses were significantly higher for 120-kV scans compared to 96-kV (0.15 vs. 0.08 mSv, p < 0.001). CONCLUSIONS: 120-kV and 96-kV CBCT provide good diagnostic images for the postoperative CI evaluation. While 120-kV showed improved depiction of temporal bone and CI electrode position compared to 96-kV in most CI models, the 120-kV protocol should be chosen wisely due to a substantially higher radiation exposure.


Subject(s)
Cochlear Implants , Cone-Beam Computed Tomography , Radiation Dosage , Temporal Bone , Humans , Cone-Beam Computed Tomography/methods , Male , Middle Aged , Female , Retrospective Studies , Temporal Bone/diagnostic imaging , Aged , Adult , Cochlear Implantation/methods
3.
Article in English | MEDLINE | ID: mdl-38705897

ABSTRACT

INTRODUCTION: The treatment of patients with a cochlear implant (CI) is usually an elective, complex and interdisciplinary process. As an important source of information, patients often access the internet prior to treatment. The quality of internet-based information regarding thematic coverage has not yet been analysed in detail. Therefore, the aim of this study was to analyse the information on CI care available on the internet regarding its thematic coverage and readability. MATERIAL METHODS: Eight search phrases related to CI care were defined as part of the study. A checklist for completeness of thematic coverage was then created for each search phrase. The current German CI clinical practice guideline and the white paper on CI care in Germany were used as a basis. As a further parameter, readability was assessed using Flesch Reading Ease Scores. The search phrases were used for an internet search with Google. The first ten results were then analysed with regard to thematic coverage, readability and the provider of the website. RESULTS: A total of 80 websites were identified, which were set up by 54 different providers (16 providers were found in multiple entries) from eight different provider groups. The average completeness of thematic coverage was 41.6 ± 28.2%. Readability according to the Flesch Reading Ease Score was categorised as "hard to read" on average (34.7 ± 14.2 points, range: 0-72). There was a negative statistically significant correlation between the thematic coverage of content and readability (Spearman's rank correlation: r = - 0.413, p = 0.00014). The completeness of thematic coverage of information on CI care available on the internet was highly heterogeneous and had a significant negative correlation with the readability. This result should be taken into account by both the providers of internet information and by patients when using internet-based information on CI care and help to further improve the quality of web-based information.

4.
HNO ; 2024 May 22.
Article in English | MEDLINE | ID: mdl-38775829

ABSTRACT

The sensitivity and the complexity of the human inner ear in conjunction with the lack of regenerative capacity are the main reasons for hearing loss and tinnitus. Progress in the development of protective and regenerative therapies for the inner ear often failed in the past not least due to the fact that no suitable model systems for cell biological and pharmacological in vitro studies were available. A novel technology for creating "mini-organs", so-called organoids, could solve this problem and has now also reached inner ear research. It makes it possible to produce inner ear organoids from cochlear stem/progenitor cells, embryonic and induced pluripotent stem cells that mimic the structural characteristics and functional properties of the natural inner ear. This review focuses on the biological basis of these inner ear organoids, the current state of research and the promising prospects that are now opening up for basic and translational inner ear research.

5.
HNO ; 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38630310

ABSTRACT

BACKGROUND: The Association of the Scientific Medical Societies in Germany (AWMF) clinical practice guideline on cochlear implant (CI) treatment, which was updated in 2020, defined the entire process of CI care for the first time. In the present study, the feasibility and results of very early rehabilitation were examined. MATERIALS AND METHODS: The intervention group (IG) comprised 54 patients in whom rehabilitation was initiated within 14 (maximally 28) days after implantation. Patients with a significantly longer waiting time were included in the control group (CG, n = 21). In addition to the start and duration of rehabilitation, the speech intelligibility achieved with CI was recorded at different timepoints within a 12-month period. In addition, questionnaires were used to assess the effort of fitting the CI processor and the patients' satisfaction with the outcome as well as the timing of the start of rehabilitation. RESULTS: Median waiting time between implantation and start of rehabilitation was 14 days in the IG and 106 days in the CG; 92.6% of IG patients were able to start rehabilitation within 14 days. The effect of rehabilitation in the IG was 35 and in the CG 25 percentage points (Freiburg monosyllabic test). After 6 and 12 months of CI use, both groups showed comparable results in the test condition in quiet (IG/CG 6 months: 70%/70%; 12 months: 70%/60%, Freiburg monosyllabic test) and in noise (IG/CG 6 months: -1.1 dB SNR/-0.85 dB SNR; 12 months: -0.65 dB SNR/+0.3 dB SNR, Oldenburg sentence test). Hearing quality assessment scores collected by SSQ (Speech, Spatial and Qualities of Hearing Scale) questionnaire showed better scores in the IG at 6 months, which converged to CG scores at 12 months. The IG was significantly more satisfied with the timing of the start of rehab than the CG. All other data obtained from questionnaires showed no differences between the two groups. CONCLUSION: A very early start of inpatient rehabilitation after cochlear implantation was successfully implemented. The rehabilitation was completed within 7 weeks of CI surgery. Comparison of speech recognition test results before and after rehabilitation showed a significant improvement. A clear rehabilitation effect can therefore be demonstrated. Inclusion of CI rehabilitation in the German catalog of follow-up treatments is thus scientifically justified and therefore strongly recommended.

6.
Allergol Select ; 8: 26-39, 2024.
Article in English | MEDLINE | ID: mdl-38549814

ABSTRACT

BACKGROUND: Chronic rhinosinusitis with nasal polyps (CRSwNP) is a multifactorial inflammatory disease of the mucous membranes of the nose and sinuses. Eosinophilic inflammation is described as a common endotype. The anti-IL-5 antibody mepolizumab was approved in November 2021 as an add-on therapy to intranasal glucocorticosteroids for the treatment of adults with severe chronic rhinosinusitis with nasal polyps when systemic glucocorticosteroids or surgery do not provide adequate disease control. While national and international recommendations exist for the use of mepolizumab in CRSwNP, it has not yet been adequately specified how this therapy should be monitored, what follow-up documentation is necessary, and when it should be discontinued if necessary. MATERIALS AND METHODS: A literature search was performed to analyze previous data on the treatment of CRSwNP with mepolizumab and to determine the available evidence by searching Medline, Pubmed, the national and international trial and guideline registries, and the Cochrane Library. Human studies published in the period up to and including 10/2022 were considered. RESULTS: Based on the international literature and previous experience by an expert panel, recommendations for follow-up, adherence to therapy intervals, and possible therapy breaks as well as discontinuation of therapy when using mepolizumab for the indication CRSwNP in the German healthcare system are given on the basis of a documentation sheet. CONCLUSION: Understanding the immunological basis of CRSwNP opens up new non-surgical therapeutic approaches with biologics for patients with severe, uncontrolled courses. Here, we provide recommendations for follow-up, adherence to therapy intervals, possible therapy pauses, or discontinuation of therapy when mepolizumab is used as add-on therapy with intranasal glucocorticosteroids to treat adult patients with severe CRSwNP that cannot be adequately controlled with systemic glucocorticosteroids and/or surgical intervention.

7.
HNO ; 72(6): 412-422, 2024 Jun.
Article in German | MEDLINE | ID: mdl-38358482

ABSTRACT

BACKGROUND: The Association of the Scientific Medical Societies in Germany (AWMF) clinical practice guideline on cochlear implant (CI) treatment, which was updated in 2020, defined the entire process of CI care for the first time. In the present study, the feasibility and results of very early rehabilitation were examined. MATERIALS AND METHODS: The intervention group (IG) comprised 54 patients in whom rehabilitation was initiated within 14 (maximally 28) days after implantation. Patients with a significantly longer waiting time were included in the control group (CG, n = 21). In addition to the start and duration of rehabilitation, the speech intelligibility achieved with CI was recorded at different timepoints within a 12-month period. In addition, questionnaires were used to assess the effort of fitting the CI processor and the patients' satisfaction with the outcome as well as the timing of the start of rehabilitation. RESULTS: Median waiting time between implantation and start of rehabilitation was 14 days in the IG and 106 days in the CG; 92.6% of IG patients were able to start rehabilitation within 14 days. The effect of rehabilitation in the IG was 35 and in the CG 25 percentage points (Freiburg monosyllabic test). After 6 and 12 months of CI use, both groups showed comparable results in the test condition in quiet (IG/CG 6 months: 70%/70%; 12 months: 70%/60%, Freiburg monosyllabic test) and in noise (IG/CG 6 months: -1.1-0.85 dB SNR; 12 months: -0.65 dB SNR/0.3 dB SNR, Oldenburg sentence test). Hearing quality assessment scores collected by SSQ (Speech, Spatial and Qualities of Hearing Scale) questionnaire showed better scores in the IG at 6 months, which converged to CG scores at 12 months. The IG was significantly more satisfied with the timing of the start of rehab than the CG. All other data obtained from questionnaires showed no differences between the two groups. CONCLUSION: A very early start of inpatient rehabilitation after cochlear implantation was successfully implemented. The rehabilitation was completed within 7 weeks of CI surgery. Comparison of speech recognition test results before and after rehabilitation showed a significant improvement. A clear rehabilitation effect can therefore be demonstrated. Inclusion of CI rehabilitation in the German catalog of follow-up treatments is thus scientifically justified and therefore strongly recommended.


Subject(s)
Cochlear Implantation , Feasibility Studies , Humans , Germany , Male , Female , Middle Aged , Treatment Outcome , Cochlear Implantation/rehabilitation , Adult , Aftercare/methods , Cochlear Implants , Aged , Patient Satisfaction , Young Adult , Hospitalization , Deafness/rehabilitation , Correction of Hearing Impairment/methods
8.
J Clin Med ; 13(4)2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38398307

ABSTRACT

(1) Background: The fitting of cochlear implants (CI) is an established treatment, even in cases with considerable residual hearing but insufficient speech perception. The aim of this study was to evaluate a prediction model for speech in quiet and to provide reference data and a predictive model for postoperative speech perception in noise (SPiN) after CI provision. (2) Methods: CI candidates with substantial residual hearing (either in hearing threshold or in word recognition scores) were included in a retrospective analysis (n = 87). Speech perception scores in quiet 12 months post-surgery were compared with the predicted scores. A generalized linear model was fitted to speech reception thresholds (SRTs) after CI fitting to identify predictive variables for SPiN. (3) Results: About two-thirds of the recipients achieved the expected outcome in quiet or were better than expected. The mean absolute error of the prediction was 13.5 percentage points. Age at implantation was the only predictive factor for SPiN showing a significant correlation (r = 0.354; p = 0.007). (4) Conclusions: Outcome prediction accuracy for speech in quiet was comparable to previous studies. For CI recipients in the included study population, the SPiN outcome could be predicted only based on the factor age.

9.
Eur Arch Otorhinolaryngol ; 281(7): 3569-3575, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38324057

ABSTRACT

PURPOSE: The aim of the presented study was to compare the audiological benefit achieved in cochlear implant (CI) patients who, in principle, could still have been treated with an active middle ear implant (AMEI) with a group of AMEI users. METHODS: Results of 20 CI patients with a pure-tone average (PTA) of 70 dB HL prior to surgery were compared with a group of 12 subjects treated with a Vibrant Soundbridge (VSB). Pre-surgical comparison included PTA for air conduction and bone conduction, maximum speech recognition score for monosyllabic words (WRSmax), and aided monosyllabic word recognition at 65 dB SPL. One year after surgery, aided monosyllabic speech recognition score at 65 dB SPL was compared. RESULTS: Mean PTA for air conduction in the VSB group was significantly lower than in the CI group (4.8 dB, Z = - 2.011, p < 0.05). Mean PTA for bone conduction in the VSB group was also significantly lower than in the CI group (23.4 dB, Z = - 4.673, p < 0.001). WRSmax in the VSB group was significantly better than in the CI group (40.7%, Z = - 3.705, p < 0.001). One year after treatment, there was no significant difference in aided speech perception in quiet between both subject groups. CONCLUSION: Comparison of the two methods showed equivalent results for both treatments in subjects with a borderline indication. Not only pure-tone audiometry results but, particularly, speech perception scores pre-surgery should be taken into account in preoperative counseling.


Subject(s)
Audiometry, Pure-Tone , Cochlear Implants , Speech Perception , Humans , Female , Middle Aged , Male , Adult , Speech Perception/physiology , Aged , Ossicular Prosthesis , Bone Conduction/physiology , Treatment Outcome , Counseling , Cochlear Implantation/methods , Preoperative Care/methods , Clinical Decision-Making
10.
Eur Arch Otorhinolaryngol ; 281(7): 3453-3460, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38353767

ABSTRACT

PURPOSE: In recent years, the number of elderly cochlear implant (CI) candidates is continuously rising. In addition to the audiological improvement, other positive effects of CI treatment can also be observed in clinical routine. The "quality of life" as a parameter of success directly experienced by the patient is increasingly becoming the focus of clinical research. Although there are already clear indications of a rapid and significant improvement in quality of life, there is still a lack of systematic, prospectively collected longitudinal long-term data in patients over the age of 65. METHODS: This prospective longitudinal observational study included 31 patients between the age of 71 and 92 years who had first been treated unilaterally with a CI 6 years ago. In addition to free-field monosyllable recognition, quality of life was assessed using the World Health Organization Quality-of-Life Scale-old (WHOQL-OLD). The results were compared with the data from our previous study, in which we focused on the short- and medium-term effects on quality of life. In both studies, the same patient population was examined. In addition, these study data were compared with an age-matched average population. RESULTS: In speech recognition, there was no significant change from the control 6 months postoperatively compared with the results 6 years postoperatively. No significant changes occurred in the total quality of life score or any of the other six facets of quality of life when comparing the results 6 months postoperatively with the results 6 years postoperatively. In "Social participation", the CI patients even exceed the values of the age-matched average population 6 years after treatment. CONCLUSION: Improvement in the quality of life and especially in social participation appears stable over many years in elderly patients after hearing rehabilitation with a CI.


Subject(s)
Cochlear Implantation , Cochlear Implants , Quality of Life , Social Participation , Humans , Aged , Male , Female , Prospective Studies , Aged, 80 and over , Cochlear Implantation/psychology , Longitudinal Studies , Treatment Outcome , Speech Perception
12.
Eur Arch Otorhinolaryngol ; 281(3): 1231-1242, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37707616

ABSTRACT

PURPOSE: Monocentric, prospective study to investigate whether concomitant support of cochlear implant (CI) patients by CI-trained otolaryngologists and application of a standardized head bandage can minimize potential complications during magnetic resonance imaging (MRI). METHODS: Thirty-seven patients with 46 CIs underwent MRI with a prophylactic head bandage. All participants and the otolaryngologist at the CI center completed pre- and post-MRI questionnaires documenting body region scanned, duration of MRI and bandage wear, field strength during the scan, and any complications. If pain was experienced, it was assessed using a visual analog scale (1-10). RESULTS: MRI was performed without adverse events in 37.8% of cases. Magnet dislocation requiring surgical revision occurred in 2% of cases. Pain was reported in 86% of cases, often due to the tightness of the dressing. Patients with rotating, MRI-compatible magnets reported significantly less pain than participants with older-generation implants. In 11% of cases, the MRI was discontinued. CONCLUSION: Serious complications during MRI in cochlear implant patients are rare. Pain is the most common adverse event, probably mainly due to the tight bandage required by most implant types. With newer generations of magnets, these patients experience less pain, no dislocation of the magnets, and no need for bandaging. Although magnet dislocation cannot be completely prevented in older generations of implants, it appears to be reduced by good patient management, which recommends examination under the guidance of physicians trained in the use of hearing implants.


Subject(s)
Cochlear Implantation , Cochlear Implants , Humans , Aged , Cochlear Implants/adverse effects , Prospective Studies , Cochlear Implantation/adverse effects , Pain/etiology , Magnetic Resonance Imaging/adverse effects , Magnets
13.
J Comput Assist Tomogr ; 48(2): 323-333, 2024.
Article in English | MEDLINE | ID: mdl-38013237

ABSTRACT

OBJECTIVE: Our study objective was to explore the additional value of dual-energy CT (DECT) material decomposition for squamous cell carcinoma of the head and neck (SCCHN) survival prognostication. METHODS: A group of 50 SCCHN patients (male, 37; female, 13; mean age, 63.6 ± 10.82 years) with baseline head and neck DECT between September 2014 and August 2020 were retrospectively included. Primary tumors were segmented, radiomics features were extracted, and DECT material decomposition was performed. We used independent train and validation datasets with cross-validation and 100 independent iterations to identify prognostic signatures applying elastic net (EN) and random survival forest (RSF). Features were ranked and intercorrelated according to their prognostic importance. We benchmarked the models against clinical parameters. Intraclass correlation coefficients were used to analyze the interreader variation. RESULTS: The exclusively radiomics-trained models achieved similar ( P = 0.947) prognostic performance of area under the curve (AUC) = 0.784 (95% confidence interval [CI], 0.775-0.812) (EN) and AUC = 0.785 (95% CI, 0.759-0.812) (RSF). The additional application of DECT material decomposition did not improve the model's performance (EN, P = 0.594; RSF, P = 0.198). In the clinical benchmark, the top averaged AUC value of 0.643 (95% CI, 0.611-0.675) was inferior to the quantitative imaging-biomarker models ( P < 0.001). A combined imaging and clinical model did not improve the imaging-based models ( P > 0.101). Shape features revealed high prognostic importance. CONCLUSIONS: Radiomics AI applications may be used for SCCHN survival prognostication, but the spectral information of DECT material decomposition did not improve the model's performance in our preliminary investigation.


Subject(s)
Head and Neck Neoplasms , Radiomics , Humans , Male , Female , Middle Aged , Aged , Squamous Cell Carcinoma of Head and Neck/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed/methods , Head and Neck Neoplasms/diagnostic imaging
14.
HNO ; 72(Suppl 1): 10-16, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37552279

ABSTRACT

BACKGROUND: Although good speech perception in quiet is achievable with cochlear implants (CIs), speech perception in noise is severely impaired compared to normal hearing (NH). In the case of a bimodal CI fitting with a hearing aid (HA) in the opposite ear, the amount of residual acoustic hearing influences speech perception in noise. OBJECTIVE: The aim of this work was to investigate speech perception in noise in a group of bimodal CI users and compare the results to age-matched HA users and people without subjective hearing loss, as well as with a young NH group. MATERIALS AND METHODS: Study participants comprised 19 bimodal CI users, 39 HA users, and 40 subjectively NH subjects in the age group 60-90 years and 14 young NH subjects. Speech reception thresholds (SRTs) in noise were adaptively measured using the Oldenburg Sentence Test for the two spatial test conditions S0N0 (speech and noise from the front) and multisource-noise field (MSNF; speech from the front, four spatially distributed noise sources) in continuous noise of the Oldenburg Sentence Test (Ol-noise) and amplitude-modulated Fastl noise (Fastl-noise). RESULTS: With increasing hearing loss, the median SRT worsened significantly in all conditions. In test condition S0N0, the SRT of the CI group was 5.6 dB worse in Ol-noise than in the young NH group (mean age 26.4 years) and 22.5 dB worse in Fastl-noise; in MSNF, the differences were 6.6 dB (Ol-noise) and 17.3 dB (Fastl-noise), respectively. In the young NH group, median SRT in condition S0N0 improved by 11 dB due to gap listening; in the older NH group, SRTs improved by only 3.1 dB. In the HA and bimodal CI groups there was no gap listening effect and SRTs in Fastl-noise were even worse than in Ol-noise. CONCLUSION: With increasing hearing loss, speech perception in modulated noise is even more impaired than in continuous noise.


Subject(s)
Cochlear Implantation , Cochlear Implants , Deafness , Hearing Aids , Hearing Loss , Speech Perception , Humans , Adult , Middle Aged , Aged , Aged, 80 and over , Noise , Hearing Loss/diagnosis
15.
Am J Case Rep ; 24: e940985, 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38031394

ABSTRACT

BACKGROUND Benign pleomorphic adenoma is the most common primary tumor of the salivary glands and mainly arises in the parotid gland. Warthin's tumor, or papillary cystadenoma lymphomatosum, represents <30% of benign parotid tumors. The simultaneous occurrence of multiple parotid tumors is rarely described - depending on the corresponding histology (different/identical), the time of their occurrence (synchronous/metachronous), as well as their location (unilateral/bilateral), multiple parotid tumors can be further sub-classified. CASE REPORT We describe the case of a 54-year-old female patient with progressive and painful swelling of the left parotid gland for the last 6 months. During extra-oral examination, a bulging, displaceable mass of approximately 3 cm was determined. A subsequent MRI (magnetic resonance imaging) examination revealed a multifocal lesion but failed to provide a decisive clue as to the tumor entity of the lesion, and a lateral (superficial) parotidectomy was performed. Postoperative histomorphological interpretation allowed the final pathological diagnosis of synchronous, unilateral occurrence of a pleomorphic adenoma as well as a Warthin's tumor. CONCLUSIONS This report presents a rare case of synchronous unilateral parotid tumors and supports that benign pleomorphic adenoma and Warthin's tumor are the most common associations. Since clinical examination, MRI imaging, and even cytological assessment could be misleading in the detection of synchronous ipsilateral multiple parotid gland tumors, our report also highlights the importance of timely and accurate diagnosis with histopathology to plan surgery and to exclude malignant transformation, which is a rare but important association with both types of primary salivary gland tumor.


Subject(s)
Adenolymphoma , Adenoma, Pleomorphic , Neoplasms, Multiple Primary , Parotid Neoplasms , Female , Humans , Middle Aged , Parotid Gland/diagnostic imaging , Parotid Gland/surgery , Parotid Gland/pathology , Adenolymphoma/complications , Adenolymphoma/surgery , Adenolymphoma/diagnosis , Adenoma, Pleomorphic/surgery , Adenoma, Pleomorphic/pathology , Parotid Neoplasms/surgery , Parotid Neoplasms/pathology , Neoplasms, Multiple Primary/pathology
16.
HNO ; 71(11): 702-707, 2023 Nov.
Article in German | MEDLINE | ID: mdl-37845538

ABSTRACT

The sensitivity and the complexity of the human inner ear in conjunction with the lack of regenerative capacity are the main reasons for hearing loss and tinnitus. Progress in the development of protective and regenerative therapies for the inner ear often failed in the past not least due to the fact that no suitable model systems for cell biological and pharmacological in vitro studies were available. A novel technology for creating "mini-organs", so-called organoids, could solve this problem and has now also reached inner ear research. It makes it possible to produce inner ear organoids from cochlear stem/progenitor cells, embryonic and induced pluripotent stem cells that mimic the structural characteristics and functional properties of the natural inner ear. This review focuses on the biological basis of these inner ear organoids, the current state of research and the promising prospects that are now opening up for basic and translational inner ear research.


Subject(s)
Deafness , Ear, Inner , Hearing Loss , Humans , Hearing Loss/therapy , Organoids , Cochlea , Cell Differentiation
17.
HNO ; 71(8): 487-493, 2023 Aug.
Article in German | MEDLINE | ID: mdl-37395783

ABSTRACT

BACKGROUND: Although good speech perception in quiet is achievable with cochlear implants (CIs), speech perception in noise is severely impaired compared to normal hearing (NH). In the case of a bimodal CI fitting with a hearing aid (HA) in the opposite ear, the amount of residual acoustic hearing influences speech perception in noise. OBJECTIVE: The aim of this work was to investigate speech perception in noise in a group of bimodal CI users and compare the results to age-matched HA users and people without subjective hearing loss, as well as with a young NH group. MATERIALS AND METHODS: Study participants comprised 19 bimodal CI users, 39 HA users, and 40 subjectively NH subjects in the age group 60-90 years and 14 young NH subjects. Speech reception thresholds (SRTs) in noise were adaptively measured using the Oldenburg Sentence Test for the two spatial test conditions S0N0 (speech and noise from the front) and multisource-noise field (MSNF; speech from the front, four spatially distributed noise sources) in continuous noise of the Oldenburg Sentence Test (Ol-noise) and amplitude-modulated Fastl noise (Fastl-noise). RESULTS: With increasing hearing loss, the median SRT worsened significantly in all conditions. In test condition S0N0, the SRT of the CI group was 5.6 dB worse in Ol-noise than in the young NH group (mean age 26.4 years) and 22.5 dB worse in Fastl-noise; in MSNF, the differences were 6.6 dB (Ol-noise) and 17.3 dB (Fastl-noise), respectively. In the young NH group, median SRT in condition S0N0 improved by 11 dB due to gap listening; in the older NH group, SRTs improved by only 3.1 dB. In the HA and bimodal CI groups there was no gap listening effect and SRTs in Fastl-noise were even worse than in Ol-noise. CONCLUSION: With increasing hearing loss, speech perception in modulated noise is even more impaired than in continuous noise.


Subject(s)
Cochlear Implantation , Cochlear Implants , Deafness , Hearing Aids , Hearing Loss , Speech Perception , Humans , Adult , Middle Aged , Aged , Aged, 80 and over , Noise , Hearing Loss/diagnosis
18.
Laryngorhinootologie ; 102(6): 412-415, 2023 06.
Article in German | MEDLINE | ID: mdl-37267964

ABSTRACT

The 2018 template for otorhinolaryngology specialist training of the German Medical Association is increasingly implemented by the federal associations. In this regard, the German Society recommended an otorhinolaryngology resident training plan for Otorhinolaryngology, Head and Neck Surgery (DGHNO-KHC) together with the Professional Association of German Otorhinolaryngologists as a suggested guideline for the federal medical associations. In this context, the state medical associations currently work on criteria on the basis of which otorhinolaryngologists and their training institutions can be granted authority for such a certified otorhinolaryngology resident training program.The DGHNO-KHC last made recommendations for the granting of authorizations for specialist training in otorhinolaryngology in 1999. Many contents have changed as a result of the 2018 model specialist training regulations. Therefore, a scientifically formulated proposal for the granting of continuing education authorizations is herewith provided as recommendation to the federal state medical associations.


Subject(s)
Otolaryngology , Humans , Otolaryngology/education , Specialization , Germany
19.
BMC Med Imaging ; 23(1): 71, 2023 06 02.
Article in English | MEDLINE | ID: mdl-37268876

ABSTRACT

BACKGROUND: Treatment plans for squamous cell carcinoma of the head and neck (SCCHN) are individually decided in tumor board meetings but some treatment decision-steps lack objective prognostic estimates. Our purpose was to explore the potential of radiomics for SCCHN therapy-specific survival prognostication and to increase the models' interpretability by ranking the features based on their predictive importance. METHODS: We included 157 SCCHN patients (male, 119; female, 38; mean age, 64.39 ± 10.71 years) with baseline head and neck CT between 09/2014 and 08/2020 in this retrospective study. Patients were stratified according to their treatment. Using independent training and test datasets with cross-validation and 100 iterations, we identified, ranked and inter-correlated prognostic signatures using elastic net (EN) and random survival forest (RSF). We benchmarked the models against clinical parameters. Inter-reader variation was analyzed using intraclass-correlation coefficients (ICC). RESULTS: EN and RSF achieved top prognostication performances of AUC = 0.795 (95% CI 0.767-0.822) and AUC = 0.811 (95% CI 0.782-0.839). RSF prognostication slightly outperformed the EN for the complete (ΔAUC 0.035, p = 0.002) and radiochemotherapy (ΔAUC 0.092, p < 0.001) cohort. RSF was superior to most clinical benchmarking (p ≤ 0.006). The inter-reader correlation was moderate or high for all features classes (ICC ≥ 0.77 (± 0.19)). Shape features had the highest prognostic importance, followed by texture features. CONCLUSIONS: EN and RSF built on radiomics features may be used for survival prognostication. The prognostically leading features may vary between treatment subgroups. This warrants further validation to potentially aid clinical treatment decision making in the future.


Subject(s)
Head and Neck Neoplasms , Tomography, X-Ray Computed , Humans , Male , Female , Middle Aged , Aged , Squamous Cell Carcinoma of Head and Neck/diagnostic imaging , Squamous Cell Carcinoma of Head and Neck/therapy , Retrospective Studies , Prognosis , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/therapy
20.
Eur Arch Otorhinolaryngol ; 280(12): 5241-5249, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37219685

ABSTRACT

PURPOSE: This study investigated whether an interaural delay, e.g. caused by the processing latency of a hearing device, can affect sensitivity to interaural level differences (ILDs) in normal hearing subjects or cochlear implant (CI) users with contralateral normal hearing (SSD-CI). METHODS: Sensitivity to ILD was measured in 10 SSD-CI subjects and in 24 normal hearing subjects. The stimulus was a noise burst presented via headphones and via a direct cable connection (CI). ILD sensitivity was measured for different interaural delays in the range induced by hearing devices. ILD sensitivity was correlated with results obtained in a sound localization task using seven loudspeakers in the frontal horizontal plane. RESULTS: In the normal hearing subjects the sensitivity to interaural level differences deteriorated significantly with increasing interaural delays. In the CI group, no significant effect of interaural delays on ILD sensitivity was found. The NH subjects were significantly more sensitive to ILDs. The mean localization error in the CI group was 10.8° higher than in the normal hearing group. No correlation between sound localization ability and ILD sensitivity was found. CONCLUSION: Interaural delays influence the perception of ILDs. For normal hearing subjects a significant decrement in sensitivity to ILD was measured. The effect could not be confirmed in the tested SSD-CI group, probably due to a small subject group with large variations. The temporal matching of the two sides may be beneficial for ILD processing and thus sound localization for CI patients. However, further studies are needed for verification.


Subject(s)
Cochlear Implantation , Cochlear Implants , Sound Localization , Speech Perception , Humans , Noise
SELECTION OF CITATIONS
SEARCH DETAIL