Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Rev Sci Instrum ; 93(10): 103504, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-36319378

ABSTRACT

Spectrally resolved passive Balmer-α (D-α, H-α) measurements from the DIII-D 16 channel edge main-ion charge exchange recombination system confirm the presence of higher energy neutrals ("thermal" neutrals) in addition to the cold neutrals that recycle off the walls in the edge region of DIII-D plasmas. Charge exchange between thermal ions and edge neutrals transfers energy and momentum between the populations giving rise to thermal neutrals with energies approximating the ions in the pedestal region. Multiple charge exchange events in succession allow an electron to effectively take a random walk, transferring from ion to ion, providing a pathway of increasing energy and velocity, permitting a neutral to get deeper into the plasma before a final ionization event that contributes to the ion and electron particle fueling. Spectrally resolved measurements provide information about the density and velocity distribution of these neutrals, which has been historically valuable for validating Monte Carlo neutral models, which include the multi stage charge exchange dynamics. Here, a multi-channel set of such measurements is used to specifically isolate the details of the thermal neutrals that are responsible for fueling inside the pedestal top. Being able to separate the thermal from the cold emission overcomes several challenges associated with optical filter-based neutral density measurements. The neutral dynamics, deeper fueling by the thermal neutrals, and spectral measurement are modeled with the FIDASIM Monte Carlo collisional radiative code, which also produces synthetic spectra with a shape that is in close agreement with the measurements. By scaling the number of neutrals in the simulation to match the intensity of the thermal emission, we show it is possible to obtain local neutral densities and ionization source rates.

3.
Rev Sci Instrum ; 92(4): 043526, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243421

ABSTRACT

Fast ions in fusion plasmas often leave characteristic signatures in the plasma neutron emission. Measurements of this emission are subject to the phase-space sensitivity of the diagnostic, which can be mapped using weight functions. In this paper, we present orbit weight functions for the TOFOR and NE213 neutron diagnostics at the Joint European Torus, mapping their phase-space sensitivity in 3D orbit space. Both diagnostics are highly sensitive to fast ions that spend a relatively large fraction of their orbit transit times inside the viewing cone of the diagnostic. For most neutron energies, TOFOR is found to be relatively sensitive to potato orbits and heavily localized counter-passing orbits, as well as trapped orbits whose "banana tips" are inside the viewing cone of TOFOR. For the NE213-scintillator, the sensitivity is found to be relatively high for stagnation orbits.

4.
Rev Sci Instrum ; 92(4): 043535, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243455

ABSTRACT

Radially resolved hydrogenic isotope fraction measurement capabilities have been developed for DIII-D using the main-ion charge exchange recombination (MICER) spectroscopy system in preparation for mixed hydrogen and deuterium experiments. Constraints on the hydrogenic ion temperatures and velocities based on measurements of the impurity ion properties are required to accurately fit the spectrum. Corrections for cross sectional distortions, spatial smearing due to the halo, and a neoclassical offset between the impurity and hydrogenic toroidal rotation are applied to the constraints prior to fitting the MICER spectrum. Extensive atomic physics calculations have been performed using the FIDASIM code, which has recently been improved to allow simulations using mixtures of hydrogenic species. These results demonstrate that for the same plasma parameters, the Dα emission is 20%-30% brighter than Hα due to differences in rate coefficients associated with the different ion thermal velocities for the same temperature and therefore must be taken into consideration when calculating absolute densities. However, despite these differences, the absolute error when estimating the hydrogen isotope fraction [nH/(nH + nD)] by using the Hα radiance fraction [LHα/(LHα + LDα)] is typically less than 5% due to the way the fraction is formed, making the radiance fraction a reasonably accurate estimate of the isotope fraction for most cases.

5.
Rev Sci Instrum ; 89(10): 10D110, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399818

ABSTRACT

Main-ion charge exchange recombination spectroscopy (MICER) uses the neutral beam induced D α spectrum to measure the local deuterium ion (D+) temperature, rotation, and density, as well as parameters related to the neutral beams, fast ions, and magnetic field. An edge MICER system consisting of 16 densely packed chords was recently installed on DIII-D, extending the MICER technique from the core to the pedestal and steep gradient region of H-mode plasmas where the D+ and commonly measured impurity ion properties can differ significantly. A combination of iterative collisional radiative modeling techniques and greatly accelerated spectral fitting allowed the extension of this diagnostic technique to the plasma edge where the steep gradients introduce significant diagnostic challenges. The importance of including the fast ion D α emission in the fit to the spectrum for the edge system is investigated showing that it is typically not important except for cases which can have significant fast ion fractions near the plasma edge such as QH-mode. Example profiles from an Ohmic L-mode and a high power ITER baseline case show large differences in the toroidal rotation of the two species near the separatrix including a strong co-current D+ edge rotation. The measurements and analysis demonstrate the state of the art in active spectroscopy and integrated modeling for diagnosing fusion plasmas and the importance of direct main ion measurements.

6.
Rev Sci Instrum ; 89(6): 063507, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29960573

ABSTRACT

Analysis of fast-ion D-alpha (FIDA) data on National Spherical Torus Experiment-Upgrade (NSTX-U) shows that the cold Dα line contaminates the FIDA baseline. The scattered light is comparable to the FIDA emission. A scattering correction is required to extract the FIDA signal. Two methods that relate the scattered light contamination to the intensity of the cold Dα line are employed. One method uses laboratory measurements with a calibration lamp; the other method uses data acquired during plasma operation and singular value decomposition analysis. After correction, both the FIDA spectra and spatial profile are in better agreement with theoretical predictions.

7.
Rev Sci Instrum ; 87(11): 11E520, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910688

ABSTRACT

The first measurements of fast-ion D-alpha (FIDA) radiation have been acquired on C-2U, Tri Alpha Energy's advanced, beam-driven field-reversed configuration (FRC). These measurements are also forward modeled by FIDASIM. This is the first measurement and simulation of FIDA carried out on an FRC topology. FIDA measurements are made of Doppler-shifted Balmer-alpha light from neutralized fast ions using a bandpass filter and photomultiplier tube. One adjustable line-of-sight measured signals at eight locations and eight times during the FRC lifetime over 26 discharges. Filtered signals include only the highest energy ions (>6 keV) and share some salient features with the FIDASIM result. Highly Doppler-shifted beam radiation is also measured with a high-speed camera and is spatially well-correlated with FIDASIM.

8.
Rev Sci Instrum ; 87(11): 11E553, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910328

ABSTRACT

Recent completion of a thirty two channel main-ion (deuterium) charge exchange recombination spectroscopy (CER) diagnostic on the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] enables detailed comparisons between impurity and main-ion temperature, density, and toroidal rotation. In a H-mode DIII-D discharge, these new measurement capabilities are used to provide the deuterium density profile, demonstrate the importance of profile alignment between Thomson scattering and CER diagnostics, and aid in determining the electron temperature at the separatrix. Sixteen sightlines cover the core of the plasma and another sixteen are densely packed towards the plasma edge, providing high resolution measurements across the pedestal and steep gradient region in H-mode plasmas. Extracting useful physical quantities such as deuterium density is challenging due to multiple photoemission processes. These challenges are overcome using a detailed fitting model and by forward modeling the photoemission using the FIDASIM code, which implements a comprehensive collisional radiative model.

9.
Rev Sci Instrum ; 87(11): 11E542, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910390

ABSTRACT

To investigate the fast ion behavior, a fast ion D-alpha (FIDA) diagnostic system has been installed on EAST. Fast ion features can be inferred from the Doppler shifted spectrum of Balmer-alpha light from energetic hydrogenic atoms. This paper will focus on the validation of FIDA measurements performed using MHD-quiescent discharges in 2015 campaign. Two codes have been applied to calculate the Dα spectrum: one is a Monte Carlo code, Fortran 90 version FIDASIM, and the other is an analytical code, Simulation of Spectra (SOS). The predicted SOS fast-ion spectrum agrees well with the measurement; however, the level of fast-ion part from FIDASIM is lower. The discrepancy is possibly due to the difference between FIDASIM and SOS velocity distribution function. The details will be presented in the paper to primarily address comparisons of predicted and observed spectrum shapes/amplitudes.

10.
Phys Rev Lett ; 116(9): 095001, 2016 Mar 04.
Article in English | MEDLINE | ID: mdl-26991180

ABSTRACT

Experiments in the DIII-D tokamak show that fast-ion transport suddenly becomes stiff above a critical threshold in the presence of many overlapping small-amplitude Alfvén eigenmodes (AEs). The threshold is phase-space dependent and occurs when particle orbits become stochastic due to resonances with AEs. Above threshold, equilibrium fast-ion density profiles are unchanged despite increased drive, and intermittent fast-ion losses are observed. Fast-ion Dα spectroscopy indicates radially localized transport of the copassing population at radii that correspond to the location of midcore AEs. The observation of stiff fast-ion transport suggests that reduced models can be used to effectively predict alpha profiles, beam ion profiles, and losses to aid in the design of optimized scenarios for future burning plasma devices.

11.
Rev Sci Instrum ; 85(11): 11D803, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430216

ABSTRACT

Neutral particle analyzers (NPA) detect neutralized energetic particles that escape from plasmas. Geometric factors relate the counting rate of the detectors to the intensity of the particle source. Accurate geometric factors enable quick simulation of geometric effects without the need to resort to slower Monte Carlo methods. Previously derived expressions [G. R. Thomas and D. M. Willis, "Analytical derivation of the geometric factor of a particle detector having circular or rectangular geometry," J. Phys. E: Sci. Instrum. 5(3), 260 (1972); J. D. Sullivan, "Geometric factor and directional response of single and multi-element particle telescopes," Nucl. Instrum. Methods 95(1), 5-11 (1971)] for the geometric factor implicitly assume that the particle source is very far away from the detector (far-field); this excludes applications close to the detector (near-field). The far-field assumption does not hold in most fusion applications of NPA detectors. We derive, from probability theory, a generalized framework for deriving geometric factors that are valid for both near and far-field applications as well as for non-isotropic sources and nonlinear particle trajectories.

12.
J Heart Lung Transplant ; 20(8): 908-11, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11502415

ABSTRACT

Although lung transplant recipients have a higher prevalence of non-melanoma skin cancers and lymphoma than the general population, the same has not been noted for bronchogenic carcinoma. If an increased prevalence of bronchogenic carcinoma exists, contributing factors may include the high rate of previous tobacco use in this population and/or the chronic immunosuppression used to prevent allograft rejection. With time, the incidence of bronchogenic carcinoma in the lung transplant population is likely to parallel the increasing longevity and number of transplanted individuals. We describe 2 cases of bronchogenic carcinoma in lung transplant recipients that demonstrate the morbidity associated with the discovery or development of bronchogenic carcinoma in this population.


Subject(s)
Adenocarcinoma/pathology , Carcinoma, Bronchogenic/pathology , Carcinoma, Squamous Cell/pathology , Lung Neoplasms/pathology , Lung Transplantation/pathology , Postoperative Complications/pathology , Adenocarcinoma/surgery , Carcinoma, Bronchogenic/surgery , Carcinoma, Squamous Cell/surgery , Female , Humans , Lung/pathology , Lung Neoplasms/surgery , Lymph Node Excision , Lymphatic Metastasis , Male , Middle Aged , Neoplasm Recurrence, Local/pathology , Neoplasm Recurrence, Local/surgery , Neoplasm Staging , Pneumonectomy , Postoperative Complications/surgery , Reoperation
SELECTION OF CITATIONS
SEARCH DETAIL
...