Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Diabetes Obes Metab ; 25(12): 3779-3787, 2023 12.
Article in English | MEDLINE | ID: mdl-37722962

ABSTRACT

AIMS: To develop and validate an updated version of KidneyIntelX (kidneyintelX.dkd) to stratify patients for risk of progression of diabetic kidney disease (DKD) stages 1 to 3, to simplify the test for clinical adoption and support an application to the US Food and Drug Administration regulatory pathway. METHODS: We used plasma biomarkers and clinical data from the Penn Medicine Biobank (PMBB) for training, and independent cohorts (BioMe and CANVAS) for validation. The primary outcome was progressive decline in kidney function (PDKF), defined by a ≥40% sustained decline in estimated glomerular filtration rate or end-stage kidney disease within 5 years of follow-up. RESULTS: In 573 PMBB participants with DKD, 15.4% experienced PDKF over a median of 3.7 years. We trained a random forest model using biomarkers and clinical variables. Among 657 BioMe participants and 1197 CANVAS participants, 11.7% and 7.5%, respectively, experienced PDKF. Based on training cut-offs, 57%, 35% and 8% of BioMe participants, and 56%, 38% and 6% of CANVAS participants were classified as having low-, moderate- and high-risk levels, respectively. The cumulative incidence at these risk levels was 5.9%, 21.2% and 66.9% in BioMe and 6.7%, 13.1% and 59.6% in CANVAS. After clinical risk factor adjustment, the adjusted hazard ratios were 7.7 (95% confidence interval [CI] 3.0-19.6) and 3.7 (95% CI 2.0-6.8) in BioMe, and 5.4 (95% CI 2.5-11.9) and 2.3 (95% CI 1.4-3.9) in CANVAS, for high- versus low-risk and moderate- versus low-risk levels, respectively. CONCLUSIONS: Using two independent cohorts and a clinical trial population, we validated an updated KidneyIntelX test (named kidneyintelX.dkd), which significantly enhanced risk stratification in patients with DKD for PDKF, independently from known risk factors for progression.


Subject(s)
Diabetes Mellitus, Type 2 , Diabetic Nephropathies , United States/epidemiology , Humans , Prognosis , Diabetic Nephropathies/diagnosis , Diabetic Nephropathies/epidemiology , Diabetic Nephropathies/etiology , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/diagnosis , Disease Progression , Biomarkers
2.
Clin Chem ; 68(6): 837-847, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35312747

ABSTRACT

BACKGROUND: OncoMasTR is a recently developed multigene prognostic test for early-stage breast cancer. The test has been developed in a kit-based format for decentralized deployment in molecular pathology laboratories. The analytical performance characteristics of the OncoMasTR test are described in this study. METHODS: Expression levels of 6 genes were measured by 1-step reverse transcription-quantitative PCR on RNA samples prepared from formalin-fixed, paraffin-embedded (FFPE) breast tumor specimens. Assay precision, reproducibility, input range, and interference were determined using FFPE-derived RNA samples representative of low and high prognostic risk scores. A pooled RNA sample derived from 6 FFPE breast tumor specimens was used to establish the linear range, limit of detection, and amplification efficiency of the individual gene expression assays. RESULTS: The overall precision of the OncoMasTR test was high with an SD of 0.16, which represents less than 2% of the 10-unit risk score range. Test results were reproducible across 4 testing sites, with correlation coefficients of 0.94 to 0.96 for the continuous risk score and concordance of 86% to 96% in low-/high-risk sample classification. Consistent risk scores were obtained across a > 100-fold RNA input range. Individual gene expression assays were linear up to quantification cycle values of 36.0 to 36.9, with amplification efficiencies of 80% to 102%. Test results were not influenced by agents used during RNA isolation, by low levels of copurified genomic DNA, or by moderate levels of copurified adjacent nontumor tissue. CONCLUSION: The OncoMasTR prognostic test displays robust analytical performance that is suitable for deployment by local pathology laboratories for decentralized use.


Subject(s)
Breast Neoplasms , Biomarkers, Tumor/genetics , Breast/pathology , Breast Neoplasms/pathology , Female , Formaldehyde , Gene Expression Profiling/methods , Humans , Paraffin Embedding , Prognosis , RNA/analysis , Receptors, Estrogen/metabolism , Reproducibility of Results
3.
Clin Proteomics ; 18(1): 26, 2021 Nov 17.
Article in English | MEDLINE | ID: mdl-34789168

ABSTRACT

BACKGROUND: The KidneyIntelX™ test applies a machine learning algorithm that incorporates plasma biomarkers and clinical variables to produce a composite risk score to predict a progressive decline in kidney function in patients with type 2 diabetes (T2D) and early-stage chronic kidney disease (CKD). The following studies describe the analytical validation of the KidneyIntelX assay including impact of observed methodologic variability on the composite risk score. METHODS: Analytical performance studies of sensitivity, precision, and linearity were performed on three biomarkers assayed in multiplexed format: kidney injury molecule-1 (KIM-1), soluble tumor necrosis factor receptor-1 (sTNFR-1) and soluble tumor necrosis factor receptor-2 (sTNFR-2) based on Clinical Laboratory Standards Institute (CLSI) guidelines. Analytical variability across twenty (20) experiments across multiple days, operators, and reagent lots was assessed to examine the impact on the reproducibility of the composite risk score. Analysis of cross-reactivity and interfering substances was also performed. RESULTS: Assays for KIM-1, sTNFR-1 and sTNFR-2 demonstrated acceptable sensitivity. Mean within-laboratory imprecision coefficient of variation (CV) was established as less than 9% across all assays in a multi-lot study. The linear range of the assays was determined as 12-5807 pg/mL, 969-23,806 pg/mL and 4256-68,087 pg/mL for KIM-1, sTNFR-1 and sTNFR-2, respectively. The average risk score CV% was less than 5%, with 98% concordance observed for assignment of risk categories. Cross-reactivity between critical assay components in a multiplexed format did not exceed 1.1%. CONCLUSIONS: The set of analytical validation studies demonstrated robust analytical performance across all three biomarkers contributing to the KidneyIntelX risk score, meeting or exceeding specifications established during characterization studies. Notably, reproducibility of the composite risk score demonstrated that expected analytical laboratory variation did not impact the assigned risk category, and therefore, the clinical validity of the reported results.

4.
Am J Infect Control ; 39(7): 566-70, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21864763

ABSTRACT

BACKGROUND: As part of a comprehensive approach to decreasing Clostridium difficile in our health authority, an evaluation of the in-use performance of 2 brands of bedpan decontaminators (BPDs) in 2 acute care facilities was performed. METHODS: A continuous quality improvement approach consisting of 5 BPD audits and 4 intervention phases was used over a 16-month evaluation period. Visible fecal soil on processed items was used as the progress indicator, and infection preventionists performed audits. RESULTS: A total of 1,982 observations was recorded. Percent failures rates ranged from 7.6% to 33% dependent on the intervention phase. Polypropylene materials had fewer failures compared with stainless steel. The addition of rinse agent significantly improved results particularly in polypropylene items (1% failure rate). A number of human factors issues and equipment design features compromised the BPD's ability to function adequately. CONCLUSION: Users should thoroughly evaluate the in-use efficacy of BPDs and use a step-wise approach to identify and correct both human and equipment deficiencies. Forced function and compliance features for correct loading of machines, detergent and rinse agent dispensing, and ability to operate the machine only when detergent is present should be integral to the BPD design.


Subject(s)
Clostridioides difficile/drug effects , Disinfectants/pharmacology , Disinfection/methods , Clostridioides difficile/isolation & purification , Durable Medical Equipment , Equipment Contamination/prevention & control , Equipment Reuse , Equipment and Supplies, Hospital , Polypropylenes , Stainless Steel
5.
Anal Chim Acta ; 651(1): 98-104, 2009 Sep 28.
Article in English | MEDLINE | ID: mdl-19733742

ABSTRACT

Caseous lymphadenitis (CLA), a disease affecting sheep and goats, is caused by Corynebacterium pseudotuberculosis and is difficult to detect, especially at early stages in its development. A surface plasmon resonance-based biosensor assay for the detection of antibodies to the phospholipase D (PLD) exotoxin of C. pseudotuberculosis in sheep serum was successfully generated. It employed a recombinant form of PLD, which was immobilised, and all aspects of the assay including minimisation of non-specific binding, and the regeneration of the chip, were optimised. The applicability of the assay was initially demonstrated using sera collected from experimentally infected sheep and from sheep with no prior history of infection. The assay was then evaluated on a panel of clinical samples and the results obtained compared very favourably to those obtained by a double sandwich ELISA (over 90% similarity) and clearly verified its analytical value.


Subject(s)
Antibodies, Bacterial/blood , Biosensing Techniques/methods , Corynebacterium Infections/veterinary , Corynebacterium pseudotuberculosis/immunology , Sheep Diseases/diagnosis , Surface Plasmon Resonance/methods , Animals , Corynebacterium Infections/diagnosis , Enzyme-Linked Immunosorbent Assay , Goats , Phospholipase D/immunology , Phospholipase D/metabolism , Reagent Kits, Diagnostic , Recombinant Proteins/immunology , Recombinant Proteins/metabolism , Sheep
SELECTION OF CITATIONS
SEARCH DETAIL
...