Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 139
Filter
1.
J Clin Med ; 13(9)2024 Apr 28.
Article in English | MEDLINE | ID: mdl-38731123

ABSTRACT

The treatment of DeBakey type I aortic dissection remains a major challenge in the field of aortic surgery. To upgrade the standard of care hemiarch replacement, a novel device called an "Ascyrus Medical Dissection Stent" (AMDS) is now available. This hybrid device composed of a proximal polytetrafluoroethylene cuff and a distal non-covered nitinol stent is inserted into the aortic arch and the descending thoracic aorta during hypothermic circulatory arrest in addition to hemiarch replacement. Due to its specific design, it may result in a reduced risk for distal anastomotic new entries, the effective restoration of branch vessel malperfusion and positive aortic remodeling. In this narrative review, we provide an overview about the indications and the technical use of the AMDS. Additionally, we summarize the current available literature and discuss potential pitfalls in the application of the AMDS regarding device failure and aortic re-intervention.

2.
Article in English | MEDLINE | ID: mdl-38814808

ABSTRACT

BACKGROUND: To evaluate the outcomes of transposition of the omentum into the mediastinum to support the replacement of infected aortic grafts or to cover infected aortic grafts that are not amenable for surgical replacement. METHODS: All patients with thoracic aortic graft infections who underwent mediastinal transposition of the omentum at our institution between 2005 and 2023 were included in this study. Mediastinal transposition of the omentum was performed either after replacement of the infected graft ("curative concept") or solely as bailout procedure by wrapping the infected graft ("palliative concept"). The diagnosis, including computed tomography scans during follow-up, was made according to the criteria of the Management of Aortic Graft Infection Collaboration. RESULTS: The patient cohort consisted of 31 patients. Both in-hospital and one-year mortality were 0% (n = 0) for the curative concept (n = 9) compared to 23% (n = 5) and 41% (n = 9) for the palliative concept (n = 22), respectively. There was no graft infection-associated death or recurrence of infection after 3 years in the curative group. Survival was 52% at 3 years in the palliative group, with freedom of infection in 59% of the patients (n = 13). CONCLUSIONS: Transposition of the omentum and wrapping of the infected aortic prosthetic graft is a useful bailout strategy for patients who are ineligible for replacement of an infected aortic graft. However, mortality stays high. For radical treatment of aortic graft infections, it may prove an effective supportive therapy and represents an important tool in the armamentarium of cardiac surgeons.

3.
Article in English | MEDLINE | ID: mdl-38490254

ABSTRACT

OBJECTIVES: The combination of veno-arterial extracorporeal membrane oxygenation with a micro-axial flow pump (ECMELLA) is increasingly used for cardiogenic shock (CS) therapy. We report our experience with a novel single-artery access ECMELLA setup with either femoral (2.0) or jugular venous cannulation (2.1), respectively. METHODS: Data from 67 consecutive CS patients treated with ECMELLA 2.0 (n = 56) and 2.1 (n = 11) from December 2020 and December 2022 in a tertiary cardiac center were retrospectively analyzed. RESULTS: The mean age was 60.7 ± 11 years, 56 patients (84%) were male. CS aetiology was acute on chronic heart failure (n = 35, 52%), myocardial infarction (n = 13, 19.5%), postcardiotomy syndrome (n = 16, 24%) and myocarditis (n = 3, 4.5%). Preoperatively 31 patients (46%) were resuscitated, 53 (79%) were on a ventilator and 60 (90%) were on inotropic support. The median vasoactive inotropic score was 32, and the mean arterial lactate was 8.1 mmol/l. In 39 patients (58%), veno-arterial extracorporeal membrane oxygenation was explanted after a median ECMELLA support of 4 days. Myocardial recovery was achieved in 18 patients (27%), transition to a durable left ventricular assist device in 16 (24%). Thirty-three patients (n = 33; 49%) died on support (25 on ECMELLA and 8 on Impella after de-escalation), 9 (13%) of whom were palliated. Axillary access site bleeding occurred in 9 patients (13.5%), upper limb ischaemia requiring surgical revision in 3 (4.5%). Axillary site infection occurred in 6 cases (9%), and perioperative stroke in 10 (15%; 6 hemorrhagic, 4 thromboembolic). CONCLUSIONS: ECMELLA 2.0/2.1 is a feasible and effective therapy for severe CS. The single-artery cannulation technique is associated with a relatively low rate of access-related complications.

5.
J Clin Med ; 13(2)2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38256608

ABSTRACT

BACKGROUND: Takotsubo syndrome is, by definition, a reversible form of acute heart failure. If cardiac output is severely reduced, Takotsubo syndrome can cause cardiogenic shock, and mechanical circulatory support can serve as a bridge to recovery. To date, there are no recommendations on when to use mechanical circulatory support and on which device is particularly effective in this context. Our aim was to determine the best treatment strategy. METHODS: A systematic literature research and analysis of individual patient data was performed in MEDLINE/PubMed according to PRISMA guidelines. Our research considered original works published until 31 July 2023. RESULTS: A total of 93 publications that met the inclusion criteria were identified, providing individual data from 124 patients. Of these, 62 (50%) were treated with veno-arterial extracorporeal life support (va-ECLS), and 44 (35.5%) received a microaxial left ventricular assist device (Impella). Eighteen patients received an Impella CP and twenty-one an Impella 2.5. An intra-aortic balloon pump (IABP) without other devices was used in only 13 patients (10.5%), while other devices (BiVAD or Tandem Heart) were used in 5 patients (4%). The median initial left ventricular ejection fraction was 20%, with no difference between the four device groups except for the IABP group, which was less affected by cardiac output failure (p = 0.015). The overall survival was 86.3%. Compared to the other groups, the time to cardiac recovery was shorter with Impella (p < 0.001). CONCLUSIONS: Though the Impella treatment is new, our analysis may show a significant benefit of Impella compared to other MCS strategies for cardiogenic shock in Takotsubo syndrome.

6.
Article in English | MEDLINE | ID: mdl-38193462

ABSTRACT

With the increasing use of cardiac implantable electronic devices, the number of patients with cardiac implantable electronic device-related endocarditis is also rising. The treatment of this type of endocarditis is a challenging clinical task, in particular if device removal is required in patients who are pacemaker dependent. This video tutorial describes a treatment strategy for cardiac implantable electronic device-related endocarditis involving the tricuspid valve in pacemaker-dependent patients. The proposed treatment strategy consists of implanting an epicardial pacemaker via a minimally invasive subxiphoid approach, percutaneous aspiration of tricuspid valve vegetations and complete transvenous explantation of the infected cardiac implantable electronic device system using advanced lead extraction tools.


Subject(s)
Endocarditis , Pacemaker, Artificial , Humans , Endocarditis/etiology , Endocarditis/surgery , Prostheses and Implants , Tricuspid Valve , Electronics , Pacemaker, Artificial/adverse effects
8.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38096587

ABSTRACT

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Rheumatic Heart Disease , Tricuspid Valve Insufficiency , Humans , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/complications , Rheumatic Heart Disease/complications , Retrospective Studies
9.
J Cardiothorac Surg ; 18(1): 343, 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38012790

ABSTRACT

OBJECTIVES: Cardiogenic shock (CS) can occur in patients with Takotsubo syndrome (TTS). As TTS has received increasing attention and has been more closely researched, several aspects of the pathogenesis have been identified, particularly that an excessive release of catecholamines plays an important role. Nevertheless, evidence on specific therapy concepts is still lacking. As a result, TTS with severe hemodynamic instability and low cardiac output creates unique challenges, and mechanical circulatory support is needed with as few inotropic drugs as possible. METHODS: We present a 77-year-old female patient who underwent minimally invasive surgical mitral valve replacement. After an uneventful course, the patient developed acute heart failure eleven days after surgery. Transthoracic echocardiography (TTE) revealed a new onset of TTS. The patient needed left ventricular venting and full haemodynamic flow. We successfully implanted a microaxial left ventricular assist device (Impella 5.5) using the transaxillary approach. The haemodynamic situation stabilised immediately. The patient was weaned and the Impella 5.5 was explanted after five days. CONCLUSION: We present the first-in-man implantation of a transaxillary Impella 5.5 in a patient with TTS. The patient benefitted from Impella 5.5 therapy with full haemodynamic support and venting of the left ventricle.


Subject(s)
Heart-Assist Devices , Takotsubo Cardiomyopathy , Female , Humans , Aged , Shock, Cardiogenic/etiology , Shock, Cardiogenic/surgery , Heart-Assist Devices/adverse effects , Takotsubo Cardiomyopathy/complications , Takotsubo Cardiomyopathy/surgery , Treatment Outcome , Retrospective Studies
10.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37936325

ABSTRACT

AIMS: Transvenous lead extraction (TLE) is important in the management of cardiac implantable electronic devices but carries risk. It is most commonly completed from the superior access, often with 'bail-out' support via the femoral approach. Superior and inferior access may be used in tandem, which has been proposed as an advance in safety and efficacy. The aim of this study is to evaluate the safety and efficacy of the Tandem approach. METHOD: The 'Tandem' procedure entailed grasping of the targeted lead in the right atrium to provide countertraction as a rotational dissecting sheath was advanced over the lead from the subclavian access. Consecutive 'Tandem' procedures performed by a single operator between December 2020 and March 2023 in a single large-volume TLE centre were included and compared with the conventional superior approach (control) using 1:1 propensity score matching; patients were statistically matched for demographics. RESULTS: The Tandem in comparison with the conventional approach extracted leads of much greater dwell time (148.9 ± 79 vs. 108.6 ± 77 months, P < 0.01) in a shorter procedure duration (96 ± 36 vs. 127 ± 67 min, P < 0.01) but requiring more fluoroscopy (16.4 ± 10.9 vs. 10.8 ± 14.9 min, P < 0.01). The Tandem and control groups had similar clinical (100% vs. 94.7%, P = 0.07) and complete (94.8% vs. 92.8%, P = 0.42) success, with comparable minor (4% vs. 6.7%, P = 0.72) and major (0% vs. 4%, P = 0.25) complications; procedural (0% vs. 1.3%, P = 1) and 30-day (1.3% vs. 4%, P = 0.62) mortality were also similar. CONCLUSION: The Tandem procedure is as safe and effective as the conventional TLE. It can be applied to leads of a long dwell time with a potentially shorter procedure duration.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Device Removal/adverse effects , Device Removal/methods , Time Factors , Fluoroscopy , Treatment Outcome , Retrospective Studies
11.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37882609

ABSTRACT

AIMS: Transvenous lead extraction (TLE) is performed using non-laser and laser techniques with overall high efficacy and safety. Variation in outcomes between the two approaches does exist with limited comparative evidence in the literature. We sought to compare non-laser and laser TLE in a meta-analysis. METHODS AND RESULTS: We searched Medline, Embase, Scopus, ClinicalTrials.gov, and CENTRAL databases for TLE studies published between 1991 and 2021. From the included 68 studies, safety and efficacy data were carefully evaluated and extracted. Aggregated cases of outcomes were used to calculate odds ratio (OR), and pooled rates were synthesized from eligible studies to compare non-laser and laser techniques. Subgroup comparison of rotational tool and laser extraction was also performed. Non-laser in comparison with laser had lower procedural mortality (pooled rate 0% vs. 0.1%, P < 0.01), major complications (pooled rate 0.7% vs. 1.7%, P < 0.01), and superior vena cava (SVC) injury (pooled rate 0% vs. 0.5%, P < 0.001), with higher complete success (pooled rate 96.5% vs. 93.8%, P < 0.01). Non-laser comparatively to laser was more likely to achieve clinical [OR 2.16 (1.77-2.63), P < 0.01] and complete [OR 1.87 (1.69-2.08), P < 0.01] success, with a lower procedural mortality risk [OR 1.6 (1.02-2.5), P < 0.05]. In the subgroup analysis, rotational tool compared with laser achieved greater complete success (pooled rate 97.4% vs. 95%, P < 0.01) with lower SVC injury (pooled rate 0% vs. 0.7%, P < 0.01). CONCLUSION: Non-laser TLE is associated with a better safety and efficacy profile when compared with laser methods. There is a greater risk of SVC injury associated with laser sheath extraction.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Defibrillators, Implantable/adverse effects , Vena Cava, Superior/surgery , Device Removal/adverse effects , Device Removal/methods , Lasers , Cardiac Catheterization , Pacemaker, Artificial/adverse effects , Treatment Outcome , Retrospective Studies
12.
Front Cardiovasc Med ; 10: 1256752, 2023.
Article in English | MEDLINE | ID: mdl-37745106

ABSTRACT

Objectives: Due to the limited longevity of endovascular leads, children require thoughtful lifetime lead management strategies including conservation of access vessel patency. Consequently, there is an increasing interest in transvenous lead extraction (TLE) in children, however, data on TLE and the use of powered mechanical dissection sheaths is limited. Methods: We performed a retrospective cohort study analyzing all children <18 years that underwent TLE in our institution from 2015 to 2022. Procedural complexity, results and complications were defined as recommended by recent consensus statements. Results: Twenty-eight children [median age 12.8 (interquartile range 11.3-14.6) years] were included. Forty-one leads were extracted [median dwell time 85 (interquartile range 52-102) months]. Extractions of 31 leads (76%) in 22 patients (79%) were complex, requiring advanced extraction tools including powered bidirectional rotational dissection sheaths in 14 children. There were no major complications. Complete procedural success was achieved in 18 (64%) and clinical success in 27 patients (96%), respectively. Procedural success and complexity varied between lead types. The Medtronic SelectSecure™ lead was associated with increased odds of extraction by simple traction (p = 0.006) and complete procedural success (p < 0.001) while the Boston Scientific Fineline™ II lead family had increased odds of partial procedural failure (p = 0.017). Conclusions: TLE with the use of mechanical powered rotational dissection sheaths is feasible and safe in pediatric patients. In light of rare complications and excellent overall clinical success, TLE should be considered an important cornerstone in lifetime lead management in children. Particular lead types might be more challenging and less successful to extract.

14.
Case Rep Vasc Med ; 2023: 5178998, 2023.
Article in English | MEDLINE | ID: mdl-37636257

ABSTRACT

Introduction. Large thrombi in the inferior vena cava pose a high risk for a pulmonary embolism. Percutaneous extracorporeal circulation-based vacuum-assisted thrombus aspiration is a viable option for removal. Wall adherence of thrombotic material can compromise procedural success. Case Report. A 46-year-old female presented with a subtotal thrombotic occlusion of the inferior vena cava and the proximal right common iliac vein after weaning from extracorporeal life support. Due to severe wall adherence of the thrombotic material, the patient was treated with the combination of percutaneous extracorporeal circulation-based thrombus aspiration using the AngioVac system and a rotational thrombectomy device.

15.
J Surg Case Rep ; 2023(7): rjad389, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37416493

ABSTRACT

Implantation of a temporary percutaneous right ventricular assist device (RVAD) in patients with right heart failure after left ventricular assist device (LVAD) implantation is an established technique that may cause complications. We present a 60-year-old male patient who underwent urgent LVAD implantation. On the second postoperative day the patient developed acute right heart failure. We implanted a temporary percutaneous RVAD with two cannulas via the right internal jugular vein and the right femoral vein. Transesophageal echocardiography revealed severe pulmonary insufficiency. After performing re-sternotomy we anastomosed a prosthetic graft to the pulmonary trunk (PT), performed subxiphoid tunneling of the graft and replaced the transjugular outflow cannula. The pulmonary regurgitation caused by the percutaneous transvalvular cannula disappeared. In such case a direct anastomosis to the PT is the solution.

16.
Eur J Cardiothorac Surg ; 63(4)2023 04 03.
Article in English | MEDLINE | ID: mdl-37097902

ABSTRACT

Mechanical support options for children and small adolescents with acute left ventricular failure are often limited to extracorporeal life support (ECLS) and subsequent left ventricular assist device implantation. We report a case of a 3-year-old child weighing 12 kg with acute humoral rejection after cardiac transplantation not adequately responding to medical therapy who presented in persistent low cardiac output syndrome. We successfully stabilized the patient by implanting a Impella 2.5 device via a 6-mm Hemashield prosthesis on the right axillary artery. The patient was bridged to recovery.


Subject(s)
Heart Failure , Heart-Assist Devices , Adolescent , Humans , Child, Preschool , Shock, Cardiogenic/therapy , Treatment Outcome , Prosthesis Implantation , Retrospective Studies
17.
J Clin Med ; 12(6)2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36983272

ABSTRACT

BACKGROUND: Perioperative stroke remains a devastating complication in the operative treatment of acute type A aortic dissection. To reduce the risk of perioperative stroke, different perfusion techniques can be applied. A consensus on the preferred cerebral protection strategy does not exist. METHODS: To provide an overview about the different cerebral protection strategies, literature research on Medline/PubMed was performed. All available original articles reporting on cerebral protection in surgery for acute type A aortic dissection and neurologic outcomes since 2010 were included. RESULTS: Antegrade and retrograde cerebral perfusion may provide similar neurological outcomes while outperforming deep hypothermic circulatory arrest. The choice of arterial cannulation site and chosen level of hypothermia are influencing factors for perioperative stroke. CONCLUSIONS: Deep hypothermic circulatory arrest is not recommended as the sole cerebral protection technique. Antegrade and retrograde cerebral perfusion are today's standard to provide cerebral protection during aortic surgery. Bilateral antegrade cerebral perfusion potentially leads to superior outcomes during prolonged circulatory arrest times between 30 and 50 min. Arterial cannulation sites with antegrade perfusion (axillary, central or carotid artery) in combination with moderate hypothermia seem to be advantageous. Every concept should be complemented by adequate intraoperative neuromonitoring.

18.
Europace ; 25(2): 578-585, 2023 02 16.
Article in English | MEDLINE | ID: mdl-36477494

ABSTRACT

AIMS: In patients with infections of cardiac implantable electronic devices (CIEDs), the identification of causative pathogens is complicated by biofilm formations and previous antibiotic therapy. In this work, the impact of an additional fluorescence in situ hybridization (FISH), in combination with polymerase chain reaction and sequencing (FISHseq) was investigated. METHODS AND RESULTS: In 36 patients with CIED infections, FISHseq of explanted devices was performed and compared with standard microbiological cultivation of preoperative and intraoperative samples. The mean age was 61.9 (±16.2) years; 25 (69.4%) were males. Most patients (62.9%) had heart failure with reduced ejection fraction. Infections occurred as endoplastits (n = 26), isolated local generator pocket infection (n = 8), or both (n = 2); CIED included cardiac resynchronization therapy defibrillator (n = 17), implantable cardioverter defibrillator (n = 11), and pacemaker (n = 8) devices. The overall positive FISHseq detection rate was 97%. Intraoperatively, pathogens were isolated in 42 vs. 53% in standard cultivation vs. FISHseq, respectively. In 16 of 17 FISHseq-negative patients, the nucleic acid strain DAPI (4',6-diamidino-2-phenylindole) indicated inactive microorganisms, which were partially organized in biofilms (n = 4) or microcolonies (n = 2). In 13 patients in whom no pathogen was identified preoperatively, standard cultivation and FISHseq identified pathogens in 3 (23%) vs. 8 (62%), respectively. For the confirmation of preoperatively known bacteria, a combined approach was most efficient. CONCLUSION: Fluorescence in situ hybridization sequencing is a valuable tool to detect causative microorganisms in CIED infections. The combination of FISHseq with preoperative cultivation showed the highest efficacy in detecting pathogens. Additional cultivation of intraoperative tissue samples or swabs yielded more confirmation of pathogens known from preoperative culture.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Prosthesis-Related Infections , Male , Female , Humans , In Situ Hybridization, Fluorescence , Anti-Bacterial Agents/therapeutic use , Polymerase Chain Reaction , Prosthesis-Related Infections/diagnosis
19.
Zentralbl Chir ; 148(3): 284-292, 2023 Jun.
Article in German | MEDLINE | ID: mdl-36167311

ABSTRACT

In recent years, the use of mechanical support for patients with cardiac or circulatory failure has continuously increased, leading to 3,000 ECLS/ECMO (extracorporeal life support/extracorporeal membrane oxygenation) implantations annually in Germany. Due to the lack of guidelines, there is an urgent need for evidence-based recommendations addressing the central aspects of ECLS/ECMO therapy. In July 2015, the generation of a guideline level S3 according to the standards of the Association of the Scientific Medical Societies in Germany (AWMF) was announced by the German Society for Thoracic and Cardiovascular Surgery (GSTCVS). In a well-structured consensus process, involving experts from Germany, Austria and Switzerland, delegated by 16 scientific societies and the patients' representation, the guideline "Use of extracorporeal circulation (ECLS/ECMO) for cardiac and circulatory failure" was created under guidance of the GSTCVS, and published in February 2021. The guideline focuses on clinical aspects of initiation, continuation, weaning and aftercare, herein also addressing structural and economic issues. This article presents an overview on the methodology as well as the final recommendations.


Subject(s)
Extracorporeal Membrane Oxygenation , Shock , Humans , Societies, Scientific , Extracorporeal Circulation , Societies, Medical , Germany
20.
Surg Technol Int ; 432023 12 29.
Article in English | MEDLINE | ID: mdl-38237112

ABSTRACT

Recently, temporary mechanical circulatory support (tMCS) has been increasingly used for cardiogenic shock therapy. Originally designed as a bail-out option for patients who could not be weaned from cardiopulmonary bypass, the indications for tMCS have been expended and now enable us to support a wide range of patients with various cardiac pathologies. Modern tMCS devices include microaxial flow pumps (mAFP) which are small, versatile systems that can provide both acute cardiac support and cardiac protection for high-risk interventions. In this paper, we review different surgical implantation techniques with modern mAFP as well as specific aspects of preoperative indications and patient evaluation.

SELECTION OF CITATIONS
SEARCH DETAIL
...