Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 90
Filter
1.
Arthroplast Today ; 25: 101291, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38304245

ABSTRACT

Background: Periacetabular osteotomy (PAO) is an effective surgical procedure for managing acetabular dysplasia. The purpose of this study was to analyze the biomechanical properties of novel PAO constructs that incorporate orthopaedic trauma techniques. We hypothesize that these fixation methods will create a stiffer construct that tolerates higher loads to failure. Methods: Twenty bio-composite hemi-pelvises underwent PAO with the following fixation configurations: Group A: 4 iliac crest (IC) screws; Group B: 3 IC screws; Group C: 2 IC screws, 1 retrograde anterior column (AC) screw, and 1 lateral compression type-2 (LC2) screw directed from the anterior inferior iliac spine to the posterior inferior iliac spine; Group D: 1 AC screw, 1 LC2 screw, 1 posterior column screw; Group E: 2 LC2 screws, 1 AC screw. Constructs were loaded to failure on a material testing hydraulic press, and ultimate strength, stiffness, and osteotomy displacement were measured. Results: The highest load to failure was seen in group D (2511 N), which was significantly more than groups A (1528 N, P = .0114) and B (1348 N, P < .0001). The stiffest construct was group E (602 N/mm) compared to groups A (315 N/mm, P = .0439) and B (243 N/mm, P = .0008). Failure occurred most often with a fracture in the posterior column. Conclusions: This study supports column fixation methods used in orthopaedic trauma for PAO as biomechanically advantageous to traditional fixation techniques. These constructs may be beneficial to patients with weight-bearing concerns or early rehabilitation needs.

2.
J Orthop Trauma ; 38(2): e71-e77, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38031254

ABSTRACT

SUMMARY: Cephalomedullary nail fixation of geriatric intertrochanteric femur fractures is, and will continue to be, performed by most orthopaedic surgeons. The influence of technical factors on outcome is clear, and it is imperative that orthopaedic surgeons use contemporary strategies to achieve adequate reduction and fixation. The lateral patient position on a traction table potentially confers several advantages which surgeons can use to achieve quality outcomes even in patients who have challenging body morphology and/or fracture anatomy. A preferred surgical technique for lateral positioning is presented here and a case series comparing supine versus lateral nailing procedures. Lateral positioning was used more frequently in obese patients and by trauma-trained surgeons, and the results equal or exceed those in supine cases with respect to reduction and placement of fixation. Training surgeons in lateral nailing can deliver a reproducible strategy for reduction and fixation in straightforward and complex cases. By mastering the setup and technique on more simple cases, surgeons can be better prepared for the more complex where advantages of lateral nailing are even more apparent.


Subject(s)
Fracture Fixation, Intramedullary , Hip Fractures , Humans , Aged , Traction , Fracture Fixation, Intramedullary/methods , Hip Fractures/surgery , Hip Fractures/etiology , Patient Positioning/methods , Femur , Bone Nails , Retrospective Studies , Treatment Outcome
3.
Am Surg ; 90(4): 655-661, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37848176

ABSTRACT

BACKGROUND: Though artificial intelligence ("AI") has been increasingly applied to patient care, many of these predictive models are retrospective and not readily available for real-time decision-making. This survey-based study aims to evaluate implementation of a new, validated mortality risk calculator (Parkland Trauma Index of Mortality, "PTIM") embedded in our electronic healthrecord ("EHR") that calculates hourly predictions of mortality with high sensitivity and specificity. METHODS: This is a prospective, survey-based study performed at a level 1 trauma center. An anonymous survey was sent to surgical providers and regarding PTIM implementation. The PTIM score evaluates 23 variables including Glasgow Coma Score (GCS), vital signs, and laboratory data. RESULTS: Of the 40 completed surveys, 35 reported using PTIM in decision-making. Prior to reviewing PTIM, providers identified perceived top 3 predictors of mortality, including GCS (22/38, 58%), age (18/35, 47%), and maximum heart rate (17/35, 45%). Most providers reported the PTIM assisted their treatment decisions (27/35, 77%) and timing of operative intervention (23/35, 66%). Many providers agreed that PTIM integrated into rounds and patient assessment (22/36, 61%) and that it improved efficiency in assessing patients' potential mortality (21/36, 58%). CONCLUSIONS: Artificial intelligence algorithms are mostly retrospective and lag in real-time prediction of mortality. To our knowledge, this is the first real-time, automated algorithm predicting mortality in trauma patients. In this small survey-based study, we found PTIM assists in decision-making, timing of intervention, and improves accuracy in assessing mortality. Next steps include evaluating the short- and long-term impact on patient outcomes.


Subject(s)
Algorithms , Artificial Intelligence , Humans , Retrospective Studies , Prospective Studies , Machine Learning
4.
J Orthop Trauma ; 37(11S): S23-S27, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37828698

ABSTRACT

OBJECTIVES: The extent and timing of surgery in severely injured patients remains an unsolved problem in orthopaedic trauma. Different laboratory values or scores have been used to try to predict mortality and estimate physiological reserve. The Parkland Trauma Index of Mortality (PTIM) has been validated as an electronic medical record-integrated algorithm to help with operative timing in trauma patients. The aim of this study was to report our initial experience with PTIM and how it relates to other scores. METHODS: A retrospective chart review of level 1 and level 2 trauma patients admitted to our institution between December 2020 and November 2022 was conducted. Patients scored with PTIM with orthopaedic injuries were included in this study. Exclusion criteria were patients younger than 18 years. RESULTS: Seven hundred seventy-four patients (246 female patients) with a median age of 40.5 (18-101) were included. Mortality was 3.1%. Patients in the PTIM high-risk category (≥0.5) had a 20% mortality rate. The median PTIM was 0.075 (0-0.89) and the median Injury Severity Score (ISS) was 9.0 (1-59). PTIM (P < 0.001) and ISS (P < 0.001) were significantly lower in surviving patients. PTIM was mentioned in 7.6% of cases, and in 1.7% of cases, providers indicated an action in response to the PTIM. PTIM and ISS were significantly higher in patients with documented PTIM. CONCLUSION: PTIM is better at predicting mortality compared with ISS. Our low rate of PTIM documentation in provider notes highlights the challenges of implementing a new algorithm. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Subject(s)
Orthopedics , Wounds and Injuries , Humans , Female , Retrospective Studies , Injury Severity Score , Hospitalization , Wounds and Injuries/diagnosis , Wounds and Injuries/surgery
5.
Pathol Res Pract ; 241: 154298, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36608623

ABSTRACT

BACKGROUND: Lung cancer death remains the highest among all malignancies. Gender differences show women have an increased cancer incidence while men have worse outcomes. These observations identified that some lung carcinomas express estrogen receptors (ER). This is a promising target as antiestrogen drugs can reduce tumors and improve survival. However, there is a limited understanding of ER distribution and its clinical significance to properly design antiestrogen drug clinical trials. Thus, we comprehensively analyzed ERα and ERß expression patterns by gender, cancer cell type, and receptor location in lung cancer. METHODS: We conducted a systematic review using the PubMed database from all-time through October 2022, using MeSH terms with the keywords "lung cancer," "estrogen receptor," and "immunohistochemistry." We identified 120 studies with 21 reports being evaluated based on our inclusion criteria. RESULTS: We examined 4874 lung cancers from 5011 patients. ERß is the predominant form of ER expressed, mainly found in the nucleus. The ERß positivity rate is 51.5% in males versus 55.5% in females and was not statistically different. In contrast, ERα is predominately extranuclear in location, and ERα expression varies by gender. Males had a positivity rate of 31% versus 26.6% in females, which is statistically different. ERα is associated with a worse prognosis in some studies, while it had no effect in others. Overall, ERß was associated with a better prognosis. CONCLUSION: We characterized ER expression patterns in 4874 lung cancers. Over 50% expressed ERß with equal rates in both sexes and was associated with a better prognosis. ERα expression was slightly higher in males (31%) than females (26.6%) and was associated with a poor prognosis. Our findings suggest estrogen signaling may be a promising drug target in lung cancer.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Male , Humans , Female , Receptors, Estrogen , Carcinoma, Non-Small-Cell Lung/pathology , Estrogen Receptor alpha/metabolism , Estrogen Receptor beta/metabolism , Lung Neoplasms/pathology , Clinical Relevance , Estrogen Receptor Modulators
6.
OTA Int ; 5(4): e215, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36569108

ABSTRACT

Objectives: To compare the stability of screw fixation with that of plate fixation for symphyseal injuries in a vertically unstable pelvic injury (AO/Tile 61-C1) associated with complete disruption of the sacroiliac joint and the pubic symphysis. Methods: Eight fourth-generation composite pelvis models with sacroiliac and pubic symphyseal disruption (Sawbones, Vashon Island, WA) underwent biomechanical testing simulating static single-leg stance. Four were fixed anteriorly with a symphyseal screw, and 4 with a symphyseal plate. All had single transsacral screw fixation posteriorly. Displacement and rotation were monitored at both sacroiliac joint and pubic symphysis. Results: There was no significant difference between the 2 groups for mean maximum force generated. There was no significant difference in net displacement at both sacroiliac joint and pubic symphysis. There was significantly less rotation but more displacement in the screw group in the Z-axis. The screw group showed increased stiffness compared with the plate group. Conclusions: This is the first biomechanical study to compare screw versus plate symphyseal fixation in a Tile C model. Our biomechanical model using anterior and posterior fixation demonstrates that symphyseal screws may be a viable alternative to classically described symphyseal plating.

7.
Gastroenterology Res ; 15(4): 173-179, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36128185

ABSTRACT

Background: Lung cancer is a leading cause of mortality in the USA. Non-small cell lung cancer (NSCLC) contributes to 85% of all lung cancers. It is the most prevalent subtype amongst non-smokers, and its incidence has risen in the last 20 years. In addition, gastroesophageal reflux disease (GERD) has been associated with several lung pathologies, namely idiopathic pulmonary fibrosis and asthma. We aimed to investigate the association between GERD and NSCLC by performing a retrospective, multicenter, case-control study. This is the first study of this nature to be carried out in the USA. Methods: Data were retrieved from 17 Northwell health care facilities in the New York area between the years 2010 and 2018. Inclusion criteria were patients > 18 years of age with NSCLC (large cell, adenocarcinoma, and squamous cell). They were appropriately matched with controls based on age, gender, weight, comorbidities, and medication use. Our exposure group had a diagnosis of GERD based on the International Classification of Diseases, Ninth/10th Revision (ICD 9/10) codes and endoscopic, in addition to histological evidence if present. We excluded patients with secondary lung cancers, esophageal adenocarcinoma, other primary malignancies, Barrett's esophagus, and smokers. Logistic regression was conducted to determine the adjusted odds ratio (OR) and corresponding 95% confidence interval (CI) for the association between NSCLC and GERD. Results: A total of 1,083 subjects were included in our study: 543 (50%) patients were diagnosed with NSCLC. In this population, GERD was twice as prevalent compared to controls (20.4% vs. 11.6%, P < 0.001). Multivariate analysis demonstrated that GERD was associated with a higher risk of NSCLC compared to matched controls (OR = 1.86, 95% CI = 1.26 - 2.73). In addition, GERD patients treated with either antihistamines or proton pump inhibitors did not demonstrate an overall reduced risk of NSCLC (OR = 1.01, 95% CI = 0.48 - 2.12). Conclusions: Our study demonstrates that GERD is associated with a higher risk of NSCLC, irrespective of GERD treatment. We postulate that GERD patients suffer from chronic micro-aspirations leading to a prolonged inflammatory state within the lung parenchyma, triggering specific proliferative signaling pathways that may lead to malignant transformation.

8.
Injury ; 53(10): 3390-3393, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35820984

ABSTRACT

INTRODUCTION: Percutaneous anterior pelvic ring instrumentation is performed for retrograde screw fixation of ramus fractures, as well as for repair of pubic symphysis diastasis. The anatomic relationships of critical structures around the anterior pelvic ring, such as the spermatic cord and round ligament, have been described in only a few studies regarding the risk of iatrogenic injury during surgery. Our goal is to further describe these relationships, as well as provide radiographic information on safe corridors for percutaneous fixation. METHODS: Eighty (80) axial computed tomography scans of the abdomen, obtained for non traumatic diagnostic purposes and screened for prior abdominal trauma or procedures, were evaluated by 3 fellowship trained radiologists. Mid-symphyseal cuts were used to obtain several measurements relative to the spermatic cords (SC) or round ligaments (RL): inter-cord or inter-ligament distance, skin to cortex of symphysis distance (vertical), skin to cortex of symphysis distance (oblique), safe corridor distance (between SC/RL and femoral triangle), center safe angle (relative to bilateral ischia), maximal safe angle, and minimal safe angle. RESULTS: There were 41 male and 39 female scans included in the final analysis. The average inter-cord distance was 50.2 mm, skin to cortex vertical distance of 43.0 mm, skin to cortex oblique distance of 83.5 mm, safe corridor distance 26.3 mm, center safe angle 19.3˚, maximal safe angle 32.3˚, and minimal safe angle 13.6˚. These were further broken down by range and gender in Table 1. Agreement between radiologists was high for these different measurements with the exception of the skin to cortex oblique distance in female patients and the maximal safe angle in female patients, due to absence of round ligament in a majority of the scans. The round ligament was only present at the mid-symphyseal level for our three reviewers in 37/39, 36/39, and 24/39 of female patient scans. CONCLUSIONS: We have identified defined safe corridors for instrumentation of the anterior pelvic ring that can assist the surgeon in percutaneous application of fixation for fracture care.


Subject(s)
Fractures, Bone , Pelvic Bones , Pubic Symphysis Diastasis , Bone Screws , Female , Fracture Fixation, Internal/methods , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Humans , Male , Pelvic Bones/diagnostic imaging , Pelvic Bones/injuries , Pelvic Bones/surgery , Pubic Symphysis Diastasis/surgery , Tomography, X-Ray Computed
9.
J Orthop Trauma ; 36(10): 503-508, 2022 10 01.
Article in English | MEDLINE | ID: mdl-35551158

ABSTRACT

OBJECTIVES: OTA/AO 61C pelvic ring injuries are vertically unstable because of complete sacral fractures combined with anterior ring injury. The objective of this study was to compare the biomechanical characteristics of 4 transsacral screw constructs for posterior pelvic ring fixation, including one that uses a novel fixation method with a pair of locked washers with interdigitating cams. METHODS: Type C pelvic ring disruptions were created on 16 synthetic pelvis models. Each pelvis was fixated with an S2 screw in addition to being allocated to 1 of 4 transsacral constructs through S1: (1) 8.0-mm screw, (2) 8.0-mm bolt, (3) 8.0-mm screw locked with a nut, and (4) 8.00-mm screw locked with a nut with the addition of interdigitating washers between the screw head and ilium on the near cortex, and ilium and nut on the far cortex. The anterior ring fractures were not stabilized. Each pelvis underwent 100,000 cycles at 250 N and was then loaded to failure using a unilateral stance testing model. The anterior and posterior osteotomy sites were instrumented with pairs of infrared (IR) light-emitting markers, and the relative displacement of the markers was monitored using a three-dimensional (3D) motion capture system. Displacement measurements at 25,000; 50,000; 75,000; and 100,000 cycles and failure force were recorded for each pelvis. RESULTS: The novel washer design construct performed better than the screw construct with less posterior ring motion at 75,000 ( P = 0.029) and 100,000 cycles ( P = 0.029). CONCLUSIONS: The novel interdigitating washer design may be superior to using a screw construct alone to achieve rigid, locked posterior ring fixation in a synthetic pelvis model with a Type C pelvic ring disruption.


Subject(s)
Fractures, Bone , Pelvic Bones , Biomechanical Phenomena , Bone Screws , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Humans , Pelvic Bones/injuries , Pelvic Bones/surgery , Sacrum/injuries , Sacrum/surgery
10.
J Orthop Trauma ; 36(9): 458-464, 2022 09 01.
Article in English | MEDLINE | ID: mdl-35302965

ABSTRACT

OBJECTIVES: To report early results of the "Internal Joint Stabilizer of the Elbow" (IJS-E) in the treatment of terrible triad injuries and other unstable traumatic elbow dislocations. DESIGN: Retrospective cohort study. SETTING: Level 1 trauma center. PATIENTS/PARTICIPANTS: Seventeen patients with traumatic elbow instability treated with IJS-E over a 2-year period; 7 of whom sustained terrible triad-type injuries. INTERVENTIONS: Open reduction internal fixation with the "IJS-E". MAIN OUTCOME MEASURES: Elbow stability and arc of motion were assessed radiographically and clinically. Disabilities of the Arm, Shoulder and Hand scores were collected by telephone. RESULTS: All elbows were radiographically stable at the time of IJS-E removal. Mean time of follow-up was 9 months from index operation (range, 2.5-24 months). Mean elbow arc of motion was restored to flexion-extension 92 degrees (range, 5-125; SD, 31 degrees) and forearm pronation-supination 139 degrees (range, 0-180; SD, 48 degrees). Mean Disabilities of the Arm, Shoulder and Hand score was 22.2 (range, 7.5-45.7; SD, 13.3) for patients at least 1 month from surgery on the ipsilateral extremity. Five patients (30%) developed complications, and -2 (12%) required revision for implant failure. CONCLUSIONS: The IJS-E offered reliable treatment of traumatic elbow instability, particularly terrible triad-type injuries. It permited early range of motion and was effective in restoring elbow stability. We believe that the use of this relatively novel system should be further explored. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Elbow Injuries , Elbow Joint , Joint Dislocations , Joint Instability , Radius Fractures , Elbow , Elbow Joint/diagnostic imaging , Elbow Joint/surgery , Fracture Fixation, Internal/adverse effects , Humans , Joint Dislocations/surgery , Joint Instability/diagnostic imaging , Joint Instability/etiology , Joint Instability/surgery , Radiography , Radius Fractures/complications , Radius Fractures/diagnostic imaging , Radius Fractures/surgery , Range of Motion, Articular , Recovery of Function , Retrospective Studies , Treatment Outcome
11.
J Clin Orthop Trauma ; 26: 101806, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35242533

ABSTRACT

BACKGROUND: Percutaneous techniques are commonly used to treat pelvic ring disruptions but are not mainstream for fixation of pubic symphysis disruption worldwide. Potential advantages include less blood loss and lower risk of surgical site infection, especially in the morbidly obese or multiply injured patient. This study was performed to describe the clinical and radiographic outcomes of patients after percutaneous reduction and screw fixation of pubic symphysis disruption and to evaluate the preliminary safety and efficacy of this technique and its appropriateness for further study as an alternative method of fixation. METHODS: A retrospective review was performed to identify all patients who underwent percutaneous fixation of pubic symphysis disruption by two surgeons at an academic Level I trauma center over a 3-year period. Patients underwent percutaneous reduction and fixation of the pubic symphysis using 1 or 2 fully or partially threaded 5.5, 6.5, or 7.3 mm cannulated screws in a transverse or oblique configuration. Associated posterior ring injuries were fixed with trans-sacral and/or iliosacral screws. The primary outcome of interest was loss of reduction, defined as symphysis distance greater than 15 mm measured on final AP pelvis radiograph. Secondary outcomes collected by chart review were operative time, blood loss, vascular or urologic injury, sexual dysfunction, infection, implant loosening or breakage, and revision surgery. RESULTS: Twelve patients met criteria and primary and secondary outcomes were collected. Mean clinical and radiographic follow-up were 15 months each. One patient lost reduction. Mean operative time and blood loss were 124 min and 29 cc, respectively. No vascular or urologic injuries occurred. Two patients reported sexual dysfunction. No patients became infected or required revision surgery. Four patients underwent implant removal. Seventeen additional patients were excluded due to short follow-up and limited outcomes were collected. Two of these patients lost reduction. Three underwent implant removal. CONCLUSION: These data support percutaneous reduction and screw fixation of pubic symphysis disruption as a potentially safe and effective method of treatment that warrants further investigation.

12.
Int J Mol Sci ; 23(3)2022 Feb 08.
Article in English | MEDLINE | ID: mdl-35163806

ABSTRACT

Prevalence of type 2 diabetes increased from 2.5% of the US population in 1990 to 10.5% in 2018. This creates a major public health problem, due to increases in long-term complications of diabetes, including neuropathy, retinopathy, nephropathy, skin ulcers, amputations, and atherosclerotic cardiovascular disease. In this review, we evaluated the scientific basis that supports the use of physiologic insulin resensitization. Insulin resistance is the primary cause of type 2 diabetes. Insulin resistance leads to increasing insulin secretion, leading to beta-cell exhaustion or burnout. This triggers a cascade leading to islet cell destruction and the long-term complications of type 2 diabetes. Concurrent with insulin resistance, the regular bursts of insulin from the pancreas become irregular. This has been treated by the precise administration of insulin more physiologically. There is consistent evidence that this treatment modality can reverse the diabetes-associated complications of neuropathy, diabetic ulcers, nephropathy, and retinopathy, and that it lowers HbA1c. In conclusion, physiologic insulin resensitization has a persuasive scientific basis, significant treatment potential, and likely cost benefits.


Subject(s)
Diabetes Mellitus, Type 2/drug therapy , Insulin Resistance , Insulin, Regular, Human/therapeutic use , Diabetes Mellitus, Type 2/metabolism , Glycated Hemoglobin/metabolism , Humans , Insulin Secretion/drug effects , Insulin, Regular, Human/pharmacology , Pancreas/drug effects , Pancreas/metabolism
13.
J Orthop Trauma ; 36(6): 280-286, 2022 06 01.
Article in English | MEDLINE | ID: mdl-34653106

ABSTRACT

OBJECTIVE: Vital signs and laboratory values are used to guide decisions to use damage control techniques in lieu of early definitive fracture fixation. Previous models attempted to predict mortality risk but have limited utility. There is a need for a dynamic model that captures evolving physiologic changes during a trauma patient's hospital course. METHODS: The Parkland Trauma Index of Mortality (PTIM) is a machine learning algorithm that uses electronic medical record data to predict mortality within 48 hours during the first 3 days of hospitalization. It updates every hour, recalculating as physiology changes. The model was developed using 1935 trauma patient encounters from 2009 to 2014 and validated on 516 patient encounters from 2015 to 2016. Model performance was evaluated statistically. Data were collected retrospectively on its performance after 1 year of clinical use. RESULTS: In the validation data set, PTIM accurately predicted 52 of the sixty-three 12-hour time intervals within 48 hours of mortality, for sensitivity of 82.5% [95% confidence interval (CI), 73.1%-91.9%]. The specificity was 93.6% (95% CI, 92.5%-94.8%), and the positive predictive value (PPV) was 32.5% (95% CI, 25.2%-39.7%). PTIM predicted survival for 1608 time intervals and was incorrect only 11 times, yielding a negative predictive value of 99.3% (95% CI, 98.9%-99.7%). The area under the curve of the receiver operating characteristic curve was 0.94.During the first year of clinical use, when used in 776 patients, the last PTIM score accurately predicted 20 of the twenty-three 12-hour time intervals within 48 hours of mortality, for sensitivity of 86.9% (95% CI, 73%-100%). The specificity was 94.7% (95% CI, 93%-96%), and the positive predictive value was 33.3% (95% CI, 21.4%-45%). The model predicted survival for 716 time intervals and was incorrect 3 times, yielding a negative predictive value of 99.6% (95% CI, 99.1%-100%). The area under the curve of the receiver operating characteristic curve was 0.97. CONCLUSIONS: By adapting with the patient's physiologic response to trauma and relying on electronic medical record data alone, the PTIM overcomes many of the limitations of previous models. It may help inform decision-making for trauma patients early in their hospitalization. LEVEL OF EVIDENCE: Prognostic Level I. See Instructions for Authors for a complete description of levels of evidence.


Subject(s)
Hospitalization , Machine Learning , Humans , Predictive Value of Tests , ROC Curve , Retrospective Studies
14.
J Clin Orthop Trauma ; 16: 7-15, 2021 May.
Article in English | MEDLINE | ID: mdl-33717936

ABSTRACT

AIM: This systematic review evaluated the surgical outcomes of various ankle fracture treatment modalities in patients with Diabetes Mellitus as well as the methodological quality of the studies. METHODS: For our review, four online databases were searched: PubMed, MEDLINE (Clarivate Analytics), CINAHL (Cumulative Index to Nursing and Allied Health) and Web of Science (Clarivate Analytics). The overall methodological quality of the studies was assessed with the Coleman Methodology Score. Data regarding diabetic ankle fractures were pooled into three outcomes groups for comparison: (1) the standard fixation cohort with management of diabetic ankle fractures using ORIF with small or mini fragment internal fixation techniques following AO principles, (2) the minimally invasive cohort with diabetic ankle fracture management utilizing percutaneous cannulated screws or intramedullary fixation, and (3) the combined construct cohort treated with a combination of ORIF and another construct (transarticular or external fixation). RESULTS: The search strategy identified 2228 potential studies from the four databases and 11 were included in the final review. Compared to the standard fixation cohort, the minimally invasive cohort had increased risk of hardware breakage or migration and the combined constructs cohort had increased risk of hardware breakage or migration, surgical site infection and nonunion. Limb salvage rates were similar for the standard fixation and minimally invasive cohorts; however, the combined constructs cohort had a significantly lower limb salvage rate compared to that of the standard fixation cohort. The mean Coleman Methodology Score indicated the quality of the studies in the review was poor and consistent with its limitations. DISCUSSION: The overall quality of published studies on operative treatment of diabetic ankle fractures is low. Treating diabetic ankle fractures operatively results in a high number of complications regardless of fixation method. However, limb salvage rates remain high overall at 97.9% at a mean follow-up of 21.7 months. To achieve improved limb salvage rates and decrease complications, it is critical is to follow basic AO principles, respect the soft tissue envelope or utilize minimally invasive techniques, and be wary that certain combined constructs may be associated with higher complication rates. LEVEL OF EVIDENCE: 2.

15.
Injury ; 52(8): 2111-2115, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33612254

ABSTRACT

PURPOSE: To quantitatively compare the articular exposure of the proximal tibia with a lateral parapatellar arthrotomy through a straight midline incision (ML) versus a lateral submeniscal arthrotomy through a curvilinear anterolateral incision (AL). METHODS: Eight surgical approaches (4 ML and 4 AL) were performed on 4 fresh cadavers. Access to key articular landmarks was assessed, including divisions of the lateral meniscus, lateral tibial spine, and anterior cruciate ligament. The boundary of the exposed articular surface of the tibia was marked, and the proximal tibias were then stripped of soft tissues. A calibrated digital image was taken of each proximal tibia, and exposed articular surface area was calculated with ImageJ software (NIH, Bethesda, MD). Statistical analysis was performed using a two-sample t-test. RESULTS: Average articular surface area exposed was 2.2 times greater through the midline approach compared with the anterolateral approach (11.2 vs 5.1 cm2, p = 0.010). All key anatomic landmarks were directly visualized through the midline approach in each specimen. Complete visualization of the lateral meniscus posterior horn, lateral tibial spine, and anterior cruciate ligament was not accomplished through the anterolateral approach in any specimen. CONCLUSIONS: The midline approach provides more extensive articular exposure of the lateral tibial plateau compared with the anterolateral approach. This improved exposure may offer an advantage when treating fractures not amenable to arthroscopic or minimally invasive techniques. It may be of most use when treating fractures with extension into the posteromedial quadrant of the lateral plateau, fractures with extensive comminution of the lateral plateau, or fractures with complex lateral meniscus tears and fractures with tibial spine involvement.


Subject(s)
Tibia , Tibial Fractures , Cadaver , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Menisci, Tibial/surgery , Tibia/surgery , Tibial Fractures/diagnostic imaging , Tibial Fractures/surgery
16.
Arch Orthop Trauma Surg ; 141(6): 917-923, 2021 Jun.
Article in English | MEDLINE | ID: mdl-32514835

ABSTRACT

INTRODUCTION: The Kocher approach is the workhorse approach to the lateral elbow. However, the exposure is often limited, particularly for open reduction. The purpose of this study is to quantitatively compare the articular exposure of the anconeus and Kocher approaches to the lateral elbow. METHODS: Eight surgical approaches (four Kocher and four Anconeus) were performed on four fresh cadavers. The right elbows of the first two specimens were dissected via the Kocher approach, and the left elbows via the anconeus approach. For the remaining two specimens, the laterality of the approaches was reversed. Access to key articular landmarks were assessed, including the capitellum, humeral trochlea, radial head, olecranon, coronoid process, and greater and lesser sigmoid notches of the ulna. A calibrated digital image was taken from the optimum surgeon's viewing angle of each approach, and these images were analyzed with ImageJ software (NIH, Bethesda, MD, USA) to calculate the area of exposed articular surfaces. RESULTS: The average surface area exposed was 2.9 times greater with the anconeus approach compared with the standard Kocher approach (8.3 vs 3.1 cm2, p value 0.001). All key anatomic landmarks were directly visualized with the anconeus approach in each specimen. Visualization of the humeral trochlea, olecranon, coronoid process, and greater and lesser sigmoid notches of the ulna was not obtained in any of the Kocher approaches. DISCUSSION: The Anconeus approach provides superior exposure of the lateral elbow joint compared with the Kocher approach. We recommend consideration of the anconeus approach for treatment of select traumatic injuries of the lateral elbow requiring increased access to the ulnohumeral and radiocapitellar joints.


Subject(s)
Arm Bones/surgery , Elbow Joint/surgery , Muscle, Skeletal/surgery , Orthopedic Procedures/methods , Humans
17.
Injury ; 52(10): 2685-2692, 2021 Oct.
Article in English | MEDLINE | ID: mdl-32943214

ABSTRACT

INTRODUCTION: There exists substantial variability in the management of pelvic ring injuries among pelvic trauma surgeons. The objective of this study was to perform a comprehensive survey on the management of pelvic ring injuries among an international group of pelvic trauma surgeons to determine areas of agreement and disagreement. METHODS: A 45-item questionnaire was developed using an online survey platform and distributed to 30 international pelvic trauma surgeons. The survey consisted of general questions on the acute management of pelvic ring injuries and questions regarding 5 cases: Lateral compression (LC) type 1 injury, LC-3, Anterior-posterior compression (APC) type 3 injury, a combined vertical shear (VS) injury through the sacrum, and VS injury through sacroiliac joint. Respondents were shown blinded anteroposterior pelvis radiographs and axial computed tomography (CT) images for each case and asked if the injury needed fixation, the type of fixation, the order of fixation, and postoperative weight-bearing status. The Kappa statistic was calculated to assess agreement between respondents for each question. RESULTS: Nineteen out of 30 pelvic trauma surgeons completed the survey. Respondents practiced in Brazil (n = 1), Germany (n = 1), India (n = 1), Italy (n = 1) United Kingdom (n = 1), and the United States (n = 14). Of the 45 questions in this survey, 38 (84%) had minimal to no agreement among the respondents. There was moderate agreement, for performing lumbopelvic fixation when indicated, for anterior and posterior fixation of the LC-3 injury, and on forgoing EUA or stress X-rays for the APC-3 injury. There was strong agreement for open reduction and internal fixation of the anterior pelvic ring in the APC-3 injury and the VS injury through the SI joint. In contrast, LC-1 injury and combined VS pelvic ring injury through the sacrum had no areas of moderate to strong agreement. DISCUSSION: This study identified specific areas of pelvic ring injury management with minimal to no agreement among pelvic trauma surgeons. Future research should target these areas with a lack of agreement to decrease practice variability and improve patient outcomes.


Subject(s)
Fractures, Bone , Pelvic Bones , Surgeons , Fracture Fixation, Internal , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Humans , Pelvic Bones/diagnostic imaging , Pelvic Bones/surgery , Retrospective Studies , Surveys and Questionnaires
19.
Orthop Clin North Am ; 51(3): 317-324, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32498950

ABSTRACT

Percutaneous reduction and fixation of pelvic ring fractures is now widely accepted as a safe and effective treatment method. The only exception remains reduction and fixation of pubic symphyseal injuries. Several units from China and one from Spain have published clinical and biomechanical studies supporting percutaneous reduction and fixation of the pubic symphysis with various screw configurations. The initial clinical results are promising. Biomechanical data show there is little difference between plate and screw fixation. We review the current literature and also present a case performed by ourselves using this novel technique.


Subject(s)
Fracture Fixation, Internal/trends , Fractures, Bone/surgery , Pelvic Bones/injuries , Pelvic Bones/surgery , Fracture Fixation, Internal/methods , Fractures, Bone/diagnostic imaging , Humans , Minimally Invasive Surgical Procedures/methods , Minimally Invasive Surgical Procedures/trends , Pelvic Bones/diagnostic imaging , Pubic Symphysis/diagnostic imaging , Pubic Symphysis/injuries , Pubic Symphysis/surgery
20.
Acta Neurochir (Wien) ; 162(8): 1995-2005, 2020 08.
Article in English | MEDLINE | ID: mdl-32440924

ABSTRACT

OBJECT: Diffusion MRI has been used to predict intraoperative consistency of tumors. Apparent diffusion coefficient (ADC) has shown predictive value as an imaging biomarker in many CNS tumors but has not been studied in a large cohort of patients with vestibular schwannoma. In this study, we examine the utility of ADC as a predictive biomarker for intraoperative tumor characteristics and postoperative facial nerve outcome. METHODS: A retrospective review of patients who underwent vestibular schwannoma resection at our institution from 2008 to 2018 yielded 87 patients, of which 72 met inclusion criteria. Operative reports and clinical records were reviewed for clinical data; MRI data were interpreted in a blinded fashion for qualitative and quantitative biomarkers, including tumor ADC. RESULTS: Mean tumor ADC values did not predict intraoperative consistency or adherence (p = 0.63). Adherent tumors were associated with worse facial nerve outcomes (p = 0.003). Regression tree analysis identified 3 ADC categories with statistically different facial nerve outcomes. The categories identified were ADC < 1006.04 × 10-6 mm2/s; ADC 1006.04-1563.93 × 10-6 mm2/s and ADC ≥ 1563.94 × 10-6 mm2/s. Postoperative and final House-Brackmann (HB) scores were significantly higher in the intermediate ADC group (2.3, p = 0.0038). HB outcomes were similar between the group with ADC < 1006.04 × 10-6 mm2/s and ≥ 1563.94 × 10-6 mm2/s (1.3 vs 1.3). CONCLUSIONS: Middle-range preoperative ADC in vestibular schwannoma suggests a less favorable postoperative HB score. Preoperative measurement of ADC in vestibular schwannoma may provide additional information regarding prognostication of facial nerve outcomes.


Subject(s)
Denervation/adverse effects , Facial Nerve Injuries/epidemiology , Facial Nerve/surgery , Magnetic Resonance Imaging/methods , Neuroma, Acoustic/surgery , Postoperative Complications/epidemiology , Adult , Aged , Facial Nerve/diagnostic imaging , Facial Nerve Injuries/prevention & control , Female , Humans , Male , Middle Aged , Postoperative Complications/prevention & control , Predictive Value of Tests , Preoperative Period
SELECTION OF CITATIONS
SEARCH DETAIL
...