COVID-19 , Dermatomycoses , Folliculitis , Malassezia , Critical Illness , Dermatomycoses/diagnosis , Humans , SARS-CoV-2ABSTRACT
Elliptic head prosthesis was realized in 1972 to better reproduce the anatomic femoral head shape. Many functional anatomy studies showed that this shape fills better the acetabulum during walk. We evaluated 59 patients with femoral neck fracture treated with Ellitica prosthesis, with 2 years minimal follow up. We obtained good functional outcome in the 45,6 percent and excellent results in the 29 percent of the patients operated with elliptic hemiarthroplasty in patients older than 60 with intracapsular femoral neck fractures, with no revision surgery or dislocation.
La prótesis parcial de cabeza elíptica fue diseñada en 1972 para reproducir la anatomía de la cabeza femoral. Muchos estudios anatómicos muestran cómo este diseño encaja mejor con el acetábulo durante la marcha. Evaluamos 59 pacientes con fractura de cuello femoral tratados con prótesis Ellitica, con un seguimiento mínimo de 2 años. Se obtuvieron buenos resultados funcionales en el 45,6 por ciento de los casos y excelentes en el 29 por ciento, además no existieron cambios radiológicos en el 84 por ciento de los casos; todos ellos pacientes mayores de 60 años con fractura intracapsular de cuello femoral sin aparición de luxación ni necesidad de cirugía de revisión.