Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Prosthet Orthot Int ; 45(2): 138-146, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-33176573

ABSTRACT

BACKGROUND: Finite element modelling has long been proposed to support prosthetic socket design. However, there is minimal detail in the literature to inform practice in developing and interpreting these complex, highly nonlinear models. OBJECTIVES: To identify best practice recommendations for finite element modelling of lower limb prosthetics, considering key modelling approaches and inputs. STUDY DESIGN: Computational modelling. METHODS: This study developed a parametric finite element model using magnetic resonance imaging data from a person with transtibial amputation. Comparative analyses were performed considering socket loading methods, socket-residuum interface parameters and soft tissue material models from the literature, to quantify their effect on the residuum's biomechanical response to a range of parameterised socket designs. RESULTS: These variables had a marked impact on the finite element model's predictions for limb-socket interface pressure and soft tissue shear distribution. CONCLUSIONS: All modelling decisions should be justified biomechanically and clinically. In order to represent the prosthetic loading scenario in silico, researchers should (1) consider the effects of donning and interface friction to capture the generated soft tissue shear stresses, (2) use representative stiffness hyperelastic material models for soft tissues when using strain to predict injury and (3) interrogate models comparatively, against a clinically-used control.


Subject(s)
Artificial Limbs , Amputation, Surgical , Finite Element Analysis , Humans , Prosthesis Design , Stress, Mechanical
2.
J Anat ; 2020 Oct 08.
Article in English | MEDLINE | ID: mdl-33090473

ABSTRACT

Describing and quantifying vascular canal orientation and volume of osteocyte lacunae in bone is important in studies of bone growth, mechanics, health and disease. It is also an important element in analysing fossil bone in palaeohistology, key to understanding the growth, life and death of extinct animals. Often, bone microstructure is studied using two-dimensional (2D) sections, and three-dimensional (3D) shape and orientation of structures are estimated by modelling the structures using idealised geometries based on information from their cross sections. However, these methods rely on structures meeting strict geometric assumptions. Recently, 3D methods have been proposed which could provide a more accurate and robust approach to bone histology, but these have not been tested in direct comparison with their 2D counterparts in terms of accuracy and sensitivity to deviations from model assumptions. We compared 2D and 3D methodologies for estimating key microstructural traits using a combination of experimental and idealised test data sets. We generated populations of cylinders (canals) and ellipsoids (osteocyte lacunae), varying the cross-sectional aspect ratios of cylinders and orientation of ellipsoids to test sensitivity to deviations from cylindricality and longitudinal orientation, respectively. Using published methods, based on 2D sections and 3D data sets, we estimated cylinder orientation and ellipsoid volume. We applied the same methods to six CT data sets of duck cortical bone, using the full volumes for 3D measurements and single CT slices to represent 2D sections. Using in silico test data sets that did deviate from ideal cylinders and ellipsoids resulted in inaccurate estimates of cylinder or canal orientation, and reduced accuracy in estimates of ellipsoid and lacunar volume. These results highlight the importance of using appropriate 3D imaging and quantitative methods for quantifying volume and orientation of 3D structures and offer approaches to significantly enhance our understanding of bone physiology based on accurate measures for bone microstructures.

3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 2073-2076, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31946309

ABSTRACT

This paper presents an architecture for generalized predictive control for an active prosthetic socket system, based on a cost function performance index measure for minimization of residual limb tissue injury. Finite element analysis of a transtibial residuum model donned with a total surface bearing socket was used to provide controller training data and biomechanical rationale for deep tissue injury risk assessment, by estimating the internal deformation state of the soft tissues and the residuum-socket interface loading under a range of prosthetic loading instances. The results demonstrate the concept of this approach for interface actuation modelled as translational spring and damper systems.


Subject(s)
Artificial Limbs , Models, Anatomic , Prosthesis Design , Biomechanical Phenomena , Finite Element Analysis , Humans
4.
J Rehabil Res Dev ; 53(2): 207-18, 2016.
Article in English | MEDLINE | ID: mdl-27148905

ABSTRACT

Successful prosthetic rehabilitation following lower-limb amputation depends upon a safe and comfortable socket-residual limb interface. Current practice predominantly uses a subjective, iterative process to establish socket shape, often requiring several visits to a prosthetist. This study proposes an objective methodology for residual-limb shape scanning and analysis by high-resolution, automated measurements. A three-dimensional printed "analog" residuum was scanned with three surface digitizers on 10 occasions. Accuracy was measured by the scan height error between repeat analog scans and the computer-aided design (CAD) geometry and the scan versus CAD volume. Subsequently, 20 male residuum casts from ambulatory individuals with transtibial amputation were scanned by two observers, and 10 were repeat-scanned by one observer. The shape files were aligned spatially and geometric measurements extracted. Repeatability was evaluated by intraclass correlation, Bland-Altman analysis of scan volumes, and pairwise root-mean-square error ranges of scan area and width profiles. Submillimeter accuracy was achieved when scanning the analog shape, and using male residuum casts the process was highly repeatable within and between observers. The technique provides clinical researchers and prosthetists the capability to establish their own quantitative, objective, multipatient data sets, providing an evidence base for training, long-term follow-up, and interpatient outcome comparison, for decision support in socket design.


Subject(s)
Amputation Stumps/diagnostic imaging , Amputation, Surgical/rehabilitation , Artificial Limbs , Prosthesis Fitting/methods , Computer-Aided Design , Humans , Imaging, Three-Dimensional , Male , Observer Variation , Prosthesis Design , Reproducibility of Results , Tibia
SELECTION OF CITATIONS
SEARCH DETAIL
...