Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Aesthetic Plast Surg ; 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702517

ABSTRACT

The purpose of this paper was to compile a thoroughly elaborated step-by-step guide for the preoperative marking and operative technique for superior medial pedicle inverted T breast reduction based on our long experience and technical refinements. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

2.
Front Immunol ; 15: 1342895, 2024.
Article in English | MEDLINE | ID: mdl-38566997

ABSTRACT

Excessive fibrous capsule formation around silicone mammary implants (SMI) involves immune reactions to silicone. Capsular fibrosis, a common SMI complication linked to host responses, worsens with specific implant topographies. Our study with 10 patients investigated intra- and inter-individually, reduced surface roughness effects on disease progression, wound responses, chronic inflammation, and capsular composition. The results illuminate the significant impact of surface roughness on acute inflammatory responses, fibrinogen accumulation, and the subsequent fibrotic cascade. The reduction of surface roughness to an average roughness of 4 µm emerges as a promising approach for mitigating detrimental immune reactions, promoting healthy wound healing, and curbing excessive fibrosis. The identified proteins adhering to rougher surfaces shed light on potential mediators of pro-inflammatory and pro-fibrotic processes, further emphasizing the need for meticulous consideration of surface design. The composition of the implant capsule and the discovery of intracapsular HSP60 expression highlight the intricate web of stress responses and immune activation that can impact long-term tissue outcomes.


Subject(s)
Inflammation , Prostheses and Implants , Humans , Silicones , Fibrosis , Wound Healing
3.
Int J Mol Sci ; 25(6)2024 Mar 09.
Article in English | MEDLINE | ID: mdl-38542137

ABSTRACT

Breast cancer is the most common cancer in women globally, often necessitating mastectomy and subsequent breast reconstruction. Silicone mammary implants (SMIs) play a pivotal role in breast reconstruction, yet their interaction with the host immune system and microbiome remains poorly understood. This study investigates the impact of SMI surface topography on host antimicrobial responses, wound proteome dynamics, and microbial colonization. Biological samples were collected from ten human patients undergoing breast reconstruction with SMIs. Mass spectrometry profiles were analyzed for acute and chronic wound proteomes, revealing a nuanced interplay between topography and antimicrobial response proteins. 16S rRNA sequencing assessed microbiome dynamics, unveiling topography-specific variations in microbial composition. Surface topography alterations influenced wound proteome composition. Microbiome analysis revealed heightened diversity around rougher SMIs, emphasizing topography-dependent microbial invasion. In vitro experiments confirmed staphylococcal adhesion, growth, and biofilm formation on SMI surfaces, with increased texture correlating positively with bacterial colonization. This comprehensive investigation highlights the intricate interplay between SMI topography, wound proteome dynamics, and microbial transmission. The findings contribute to understanding host-microbe interactions on SMI surfaces, essential for optimizing clinical applications and minimizing complications in breast reconstruction.


Subject(s)
Anti-Infective Agents , Breast Implants , Breast Neoplasms , Humans , Female , Silicones , Breast Implants/adverse effects , Breast Neoplasms/surgery , Proteome , RNA, Ribosomal, 16S/genetics , Mastectomy , Fibrosis
4.
Eur J Clin Invest ; 51(9): e13570, 2021 Sep.
Article in English | MEDLINE | ID: mdl-33954997

ABSTRACT

BACKGROUND: This study aimed to evaluate the differences in outcome arising from the use of semi-compliant (SCB) versus non-compliant balloon (NCB) systems for predilatation during self-expanding transcatheter aortic valve replacement (TAVR). METHODS: 251 TAVR procedures with the implantation of self-expanding valves after predilatation were analyzed. SCB systems were used in 166 and NCB systems in 85 patients. The primary endpoint was defined as device success, a composite endpoint comprising the absence of procedural mortality, correct valve positioning, adequate valve performance and the absence of more than a mild paravalvular leak. The secondary endpoints were chosen in accordance with the valve academic research consortium (VARC-2) endpoint definitions. RESULTS: No significant differences were observed with regard to procedural device success between the SCB- and NCB cohort (SCB: 142 [85.5%%] vs. NCB: 77 [90.6%]; P = .257). There was a notable difference between the rates of conversion to open surgery and the postdilatation rate, both of which were higher for the NCB group (SCB: 1 [0.6%] vs. NCB: 4 [5.1%]; P = .042; SCB: 30 [18.1%] vs. NCB: 34 [40%]; P < .001). In a multivariate logistic regression analysis, the use of semi-compliant balloon systems for predilatation was associated with a lower risk for postdilatation (OR: 0.296; 95% CI: 0.149-0.588) and conversion to open surgery (OR: 0.205; 95% CI: 0.085-0.493; P = .001) but not for device success. CONCLUSION: While the balloon compliance did not affect the procedural mortality, device success or the rate of paravalvular leakage, the use of semi-compliant balloons for predilatation during TAVR should be investigated in larger randomized trials in the light of the lower rates of postdilatation and conversion to open surgery compared to their non-compliant counterparts.


Subject(s)
Aortic Valve Stenosis/surgery , Balloon Valvuloplasty/instrumentation , Mortality , Transcatheter Aortic Valve Replacement/instrumentation , Acute Kidney Injury/epidemiology , Aged , Aged, 80 and over , Atrioventricular Block/epidemiology , Balloon Valvuloplasty/methods , Bundle-Branch Block/epidemiology , Cause of Death , Conversion to Open Surgery/statistics & numerical data , Female , Humans , Male , Postoperative Complications/epidemiology , Registries , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...