1.
Mol Imaging Biol ; 2023 Sep 18.
Article in English | MEDLINE | ID: mdl-37721686

ABSTRACT

PURPOSE: Tumor hypoxia contributes to aggressive phenotypes and diminished therapeutic responses to radiation therapy (RT) with hypoxic tissue being 3-fold less radiosensitive than normoxic tissue. A major challenge in implementing hypoxic radiosensitizers is the lack of a high-resolution imaging modality that directly quantifies tissue-oxygen. The electron paramagnetic resonance oxygen-imager (EPROI) was used to quantify tumor oxygenation in two murine tumor models: E0771 syngeneic transplant breast cancers and primary p53/MCA soft tissue sarcomas, with the latter autochthonous model better recapitulating the tumor microenvironment in human malignancies. We hypothesized that tumor hypoxia differs between these models. We also aimed to quantify the absolute change in tumor hypoxia induced by the mitochondrial inhibitor papaverine (PPV) and its effect on RT response. PROCEDURES: Tumor oxygenation was characterized in E0771 and primary p53/MCA sarcomas via EPROI, with the former model also being quantified indirectly via diffuse reflectance spectroscopy (DRS). After confirming PPV's effect on hypoxic fraction (via EPROI), we compared the effect of 0 versus 2 mg/kg PPV prior to 20 Gy on tumor growth delay and survival. RESULTS: Hypoxic sarcomas were more radioresistant than normoxic sarcomas (p=0.0057, 2-way ANOVA), and high baseline hypoxic fraction was a significant (p=0.0063, Cox Regression Model) hazard in survivability regardless of treatment. Pre-treatment with PPV before RT did not radiosensitize tumors in the sarcoma or E0771 model. In the sarcoma model, EPROI successfully identified baseline hypoxic tumors. DRS quantification of total hemoglobin, saturated hemoglobin, changes in mitochondrial potential and glucose uptake showed no significant difference in E0771 tumors pre- and post-PPV. CONCLUSION: EPROI provides 3D high-resolution pO2 quantification; EPR is better suited than DRS to characterize tumor hypoxia. PPV did not radiosensitize E0771 tumors nor p53/MCA sarcomas, which may be related to the complex pattern of vasculature in each tumor. Additionally, understanding model-dependent tumor hypoxia will provide a much-needed foundation for future therapeutic studies with hypoxic radiosensitizers.

2.
Curr Oncol ; 30(3): 2751-2760, 2023 02 24.
Article in English | MEDLINE | ID: mdl-36975421

ABSTRACT

Diffuse reflectance spectroscopy (DRS) is a powerful tool for quantifying optical and physiological tissue properties such as hemoglobin oxygen saturation and vascularity. DRS is increasingly used clinically for distinguishing cancerous lesions from normal tissue. However, its widespread clinical acceptance is still limited due to uncontrolled probe-tissue interface pressure that influences reproducibility and introduces operator-dependent results. In this clinical study, we assessed and validated a pressure-sensing and automatic self-calibration DRS in patients with suspected head and neck squamous cell carcinoma (HNSCC). The clinical study enrolled nineteen patients undergoing HNSCC surgical biopsy procedures. Patients consented to evaluation of this improved DRS system during surgery. For each patient, we obtained 10 repeated measurements on one tumor site and one distant normal location. Using a Monte Carlo-based model, we extracted the hemoglobin saturation data along with total hemoglobin content and scattering properties. A total of twelve cancer tissue samples from HNSCC patients and fourteen normal tissues were analyzed. A linear mixed effects model tested for significance between repeated measurements and compared tumor versus normal tissue. These results demonstrate that cancerous tissues have a significantly lower hemoglobin saturation compared to normal controls (p < 0.001), which may be reflective of tumor hypoxia. In addition, there were minimal changes over time upon probe placement and repeated measurement, indicating that the pressure-induced changes were minimal and repeated measurements did not differ significantly from the initial value. This study demonstrates the feasibility of conducting optical spectroscopy measurements on intact lesions prior to removal during HNSCC procedures, and established that this probe provides diagnostically-relevant physiologic information that may impact further treatment.


Subject(s)
Head and Neck Neoplasms , Humans , Squamous Cell Carcinoma of Head and Neck , Reproducibility of Results , Spectrum Analysis/methods , Head and Neck Neoplasms/diagnostic imaging , Hemoglobins
4.
J Med Microbiol ; 71(12)2022 Dec.
Article in English | MEDLINE | ID: mdl-36748506

ABSTRACT

Corynebacterium kroppenstedtii breast abscesses and granulomatous mastitis have gained increased recognition in the 20 years since their association was first described. No studies to date have described this organism in the context of all breast abscess pathogens. We retrospectively reviewed 160 community-acquired breast abscess samples from 135 patients in a 3 year period, describing the organisms isolated along with risk factors, site of infection and outcomes. We compared patient subgroups with acute and chronic abscesses, the latter defined as having a requirement for repeat aspiration more than 1 month apart. The prevalence of C. kroppenstedtii breast abscesses was 8 % in all patients (11/135), rising to 32 % in chronic abscesses (10/31), but only 1 % in acute abscesses (1/104; P<0.01). Only 10 % (1/10) of patients with C. kroppenstedtii chronic abscesses were smokers, whereas 75 % of patients (15/20) with non-C. kroppenstedtii chronic abscesses were smokers (P=0.01). C. kroppenstedtii should be considered in recurrent and prolonged infections, especially in non-smokers, and diagnostic methods altered accordingly. Identifying C. kroppenstedtii provides diagnostic clarity and alters management with recommendations for longer courses of treatment using non-beta-lactam antibiotics.


Subject(s)
Abscess , Corynebacterium Infections , Female , Humans , Abscess/drug therapy , Retrospective Studies , Corynebacterium Infections/diagnosis , Anti-Bacterial Agents/therapeutic use
7.
J Biomed Opt ; 23(5): 1-8, 2018 05.
Article in English | MEDLINE | ID: mdl-29766688

ABSTRACT

Diffuse reflectance spectroscopy (DRS) represents a quantitative, noninvasive, nondestructive means of assessing vascular oxygenation, vascularity, and structural properties. However, it is known that such measurements can be influenced by the effects of pressure, which is a major concern for reproducible and operator-independent assessment of tissues. Second, regular calibration is a necessary component of quantitative DRS to account for factors such as lamp decay and fiber bending. Without a means of reliably controlling for these factors, the accuracy of any such assessments will be reduced, and potentially biased. To address these issues, a self-calibrating, pressure-controlled DRS system is described and applied to both a patient-derived xenograft glioma model, as well as a set of healthy volunteers for assessments of oral mucosal tissues. It was shown that pressure had a significant effect on the derived optical parameters, and that the effects on the optical parameters were magnified with increasing time and pressure levels. These findings indicate that not only is it critical to integrate a pressure sensor into a DRS device, but that it is also important to do so in an automated way to trigger a measurement as soon as possible after probe contact is made to minimize the perturbation to the tissue site.


Subject(s)
Neoplasms/blood supply , Neoplasms/diagnostic imaging , Signal Processing, Computer-Assisted , Spectrum Analysis/methods , Animals , Calibration , Female , Glioma , Hemoglobins/analysis , Heterografts , Humans , Mice, Nude , Mouth Mucosa/blood supply , Mouth Mucosa/diagnostic imaging , Pressure
8.
Lasers Surg Med ; 50(3): 246-252, 2018 03.
Article in English | MEDLINE | ID: mdl-29331035

ABSTRACT

OBJECTIVE: Optical spectroscopy offers a noninvasive alternative to biopsy as a first-line screening tool for suspicious skin lesions. This study sought to define several optical parameters across malignant and benign tissue types. STUDY DESIGN: Prospective pilot trial utilizing the Zenalux IM1 optical spectroscopy device from April 2016 to February 2017. For each skin lesion, provider pre-biopsy probability of malignancy was compared to histolopathologic diagnosis. Optical data were characterized across basal cell carcinoma (BCC; n = 9), squamous cell carcinoma (SCC; n = 5), actinic keratosis (AK; n = 4), scar tissue (n = 6), nevus (n = 2), and neurofibroma (NF; n = 1). Across all patients, agreement was determined between control measurements collected adjacent to the lesion and from the upper extremity. METHODS: Prospective single center pilot study. The optical properties of 27 cutaneous lesions were collected from 18 adult patients presenting to Otolaryngology and Dermatology clinics with suspicious skin lesions warranting biopsy. Spectroscopy measurements were recorded for each lesion: two at the lesion site, two at an adjacent site (internal control), and one at the central medial upper extremity (arm control). Variables of interest included absolute oxygenated hemoglobin (Hb), Hb saturation, total Hb concentration, and Eumelanin concentration. For each lesion, internal control averages were subtracted from lesion averages to provide delta parameter values, and lesion averages were divided by internal control averages to provide ratio parameter values. RESULTS: Mean percent difference between pre-biopsy probability of malignancy and histology was 29%, with a difference of 75% or greater seen in 5 of 25 lesions. Mean values for BCC, SCC, AK, and scar tissue varied most between extracted mean reduced scatter estimate (µa'; cm- ) delta values (BCC: -2.2 ± 3.8; SCC: -3.9 ± 2.0; AK: -3.3 ± 4.2, Scar: -1.7 ± 1.2) and total Hb (µM) ratio (BCC: 2.0 ± 3.3; SCC: 3.0 ± 1.3; AK: 1.1 ± 0.6; Scar: 1.4 ± 1.1). Agreement between local and arm controls was poor. CONCLUSION: This pilot trial utilizes optical spectroscopy as a noninvasive method for determining cutaneous lesion histology. Effect sizes observed across optical parameters for benign and malignant tissue types will guide larger prospective studies that may ultimately lead to prediction of lesional histology without need for invasive biopsy. Lasers Surg. Med. 50:246-252, 2018. © 2018 Wiley Periodicals, Inc.


Subject(s)
Carcinoma, Basal Cell/diagnostic imaging , Carcinoma, Squamous Cell/diagnostic imaging , Optical Imaging , Skin Neoplasms/diagnostic imaging , Spectrum Analysis , Aged , Female , Humans , Male , Middle Aged , Pilot Projects , Predictive Value of Tests , Prospective Studies
10.
BMJ Open ; 7(11): e018795, 2017 Nov 19.
Article in English | MEDLINE | ID: mdl-29158327

ABSTRACT

OBJECTIVES: To describe the impact on early-onset group B Streptococcus (EOGBS) infection rates following reversion from screening-based to risk-based intrapartum antimicrobial prophylaxis (IAP) for prevention. SETTING: Maternity services provided by secondary healthcare organisation in North West London. PARTICIPANTS: All women who gave birth in the healthcare organisation between April 2016 and March 2017. There were no exclusions. DESIGN: Observational study comparing EOGBS rates in the postscreening period (2016-2017) with prescreening (2009-2013) and screening periods (2014-2015). METHODS: Local guidelines for risk-based IAP were reintroduced in April 2016. Compliance with guidelines was audited. Gestational age, mode of delivery, maternal demographics and EOGBS rates in three time periods were compared using Poisson regression analysis. EOGBS was defined through GBS being cultured from blood, cerebrospinal fluid or other sterile fluids within 6 days of birth. PRIMARY OUTCOME: EOGBS rates/1000 live births in prescreening, screening and postscreening periods RESULTS: Incremental changes in maternity population were observed throughout the study period (2009 onwards), in particular the ethnic profile of mothers. Of the 5033 live births in postscreening period, 9 babies developed EOGBS infection. Only one of the mothers of affected babies had a risk factor indicating use of IAP. Comparison of postscreening period with screening period showed a fivefold increase in EOGBS rates after adjustment for ethnicity (1.79 vs 0.33/1000 live births; risk ratio =5.67, p=0.009). There was no significant difference between prescreening and postscreening periods with rates of infection reverting to their prescreening level. CONCLUSIONS: This study provides further evidence of efficacy of screening-based IAP compared with risk-based IAP in prevention of EOGBS in newborns in an area of high incidence.


Subject(s)
Infectious Disease Transmission, Vertical/prevention & control , Mass Screening , Post-Exposure Prophylaxis , Pre-Exposure Prophylaxis , Pregnancy Complications, Infectious/prevention & control , Streptococcal Infections/prevention & control , Streptococcus agalactiae , Adult , Female , Humans , Infant, Newborn , Infectious Disease Transmission, Vertical/statistics & numerical data , London/epidemiology , Pregnancy , Pregnancy Complications, Infectious/diagnosis , Pregnancy Complications, Infectious/epidemiology , Pregnancy Complications, Infectious/microbiology , Streptococcal Infections/diagnosis , Streptococcal Infections/epidemiology , Streptococcal Infections/microbiology , Streptococcus agalactiae/growth & development , Young Adult
12.
Trends Hear ; 182014 May 21.
Article in English | MEDLINE | ID: mdl-24914545

ABSTRACT

The main aim of this study was to investigate the shape variation in the human ear canal and the effects of venting on the spatial design of hearing aids. The second aim was to determine the design feasibility of a multiple venting hearing aid and assess the flexibility of design provided. A statistical shape model based on principal component analysis was created from a dataset of 60 left and 49 right ears. The modal variations of these models were then examined to determine the narrowest portion of the ear canal likely to limit effective venting. Finally, 3D models of two hearing aid shells, one with multiple 0.4-mm vents and the other with a single large 3-mm vent were created. Results showed that more than 50% of the shape variation in the human ear canal can be described by the first three modes of the statistical shape model developed. The narrowest predicted variation of this model had a minimum area of 36.4 mm(2), and the mean ear shape was found to have a minimum area of approximately 48 mm(2). It is estimated that even with a conservative vent packing of 0.4, multiple venting equivalent to at least a single 2-mm vent is achievable. The predicted variation in the human ear canal provides adequate physical space for a feasible multiple vented hearing aid shell. Furthermore, as multiple small vents are able to fit in around other components in the hearing aid design, certain design flexibility is provided by this venting approach.


Subject(s)
Computer-Aided Design , Ear Canal/anatomy & histology , Hearing Aids , Anatomic Landmarks , Computer Simulation , Equipment Design , Feasibility Studies , Humans , Models, Anatomic , Models, Statistical , Pressure , Principal Component Analysis