Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
J Clin Med ; 9(3)2020 Mar 18.
Article in English | MEDLINE | ID: mdl-32197459

ABSTRACT

On magnetic resonance (MR) imaging, Modic type 1 (MT1) endplate changes and infectious spondylodiscitis share similar findings. Therefore, this study investigated vertebral bone marrow and endplate changes to enable their differentiation. The lumbar spine MR examinations of 91 adult patients were retrospectively included: 39 with MT1; 19 with early spondylodiscitis without abscess; and 33 with advanced spondylodiscitis with abscess. The assessment included percentage of bone marrow edema on sagittal short tau inversion recovery images, and the signal ratio of edema to unaffected bone and endplate contour (normal; irregular, yet intact; blurred; destructive) on sagittal unenhanced T1-weighted images. Differences were tested for statistical significance by Chi-square test and mixed model analysis of variance. The MR diagnostic accuracy in differentiating MT1 and spondylodiscitis was assessed by cross-tabulation and receiver-operating characteristic analysis. The endplate contours, edema extents, and T1-signal ratios of MT1 (extent, 31.96%; ratio, 0.83) were significantly different (p < 0.001) from early spondylodiscitis (56.42%; 0.60), and advanced spondylodiscitis (91.84%; 0.61). The highest diagnostic accuracy (sensitivity, 94.87%; specificity, 94.23%; accuracy, 94.51%) in identifying MT1 was provided by an irregular, yet intact endplate contour. This may be a useful MR feature for the differentiation between MT1 and spondylodiscitis, particularly in its early stage.

2.
J Orthop Res ; 36(10): 2797-2801, 2018 10.
Article in English | MEDLINE | ID: mdl-29701260

ABSTRACT

Dedifferentiated chondrosarcoma is a rare primary bone malignancy with a very poor prognosis. The aim of the study was to identify pretreatment serum markers as prognostic factors for the overall survival (OS) of patients with dedifferentiated chondrosarcoma. We retrospectively reviewed 33 patients with histologically confirmed dedifferentiated chondrosarcoma treated at our department from 1977 to 2015. Kaplan-Meier estimation, uni- and multivariable Cox proportional hazard model were performed to evaluate the association between serum markers such as the C-reactive protein and OS. In univariable analysis, CRP was strongly associated with OS (HR 1.35; 95%CI 1.13-1.61; p = 0.001). This association prevailed after adjustment for AJCC tumor stage (HR 1.31; 95%CI 1.02-1.57; p = 0.031) in multivariable analysis. In conclusion, our data gave evidence that baseline CRP is an independent predictor for OS in patients with dedifferentiated chondrosarcoma. CRP could be exploited for the clinical prediction of this disease in the future. © 2018 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 36:2797-2801, 2018.


Subject(s)
Bone Neoplasms/blood , Bone Neoplasms/mortality , C-Reactive Protein/metabolism , Chondrosarcoma/blood , Chondrosarcoma/mortality , Adult , Aged , Aged, 80 and over , Austria/epidemiology , Biomarkers, Tumor/blood , Bone Neoplasms/diagnosis , Chondrosarcoma/diagnosis , Female , Humans , Male , Middle Aged , Prognosis , Retrospective Studies , Young Adult
3.
J Arthroplasty ; 32(6): 1923-1929, 2017 06.
Article in English | MEDLINE | ID: mdl-28291649

ABSTRACT

BACKGROUND: Although several studies indicate excellent results for cementless implants, controversy persists regarding its use in elderly patients. We determined to evaluate the outcome on patients aged over 80 years who were treated with cementless total hip arthroplasty for primary osteoarthritis of the hip. METHODS: We assessed the data of 162 consecutive total hip arthroplasties in octogenarian patients (mean age 83 years, range 80-96 years). A control group was created, consisting of 342 patients aged younger than 80 years (mean age 65 years, range 37-79 years). The median follow-up of the cohort was 128.4 months (range 6-211). RESULTS: Competing risk analyses revealed a cumulative implant survival of 98.1% at 5 and 10 years in the study group compared to 99.1% and 98.4% in the control group, taking system exchange as the end point. No differences in regard to system exchange could be detected between the groups. A significantly worsened complication-free survival rate was evident in the octogenarian group. Osteoporosis was the most powerful risk factor that proved to have a significant negative impact on development of complications. CONCLUSION: Uncemented total hip arthroplasty is a viable option for the elderly patient. In this population sector, an excellent rate of implant survival can be expected. However, a significant increase of total complications in the octogenarian group could be detected, and was mainly caused by an elevated number of early postoperative complications. Osteoporosis turned out to be a strong risk factor in regard to complication-free survival. Surgeons should therefore be aware of this.


Subject(s)
Arthroplasty, Replacement, Hip/statistics & numerical data , Osteoarthritis, Hip/surgery , Postoperative Complications/epidemiology , Adult , Age Factors , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Austria/epidemiology , Case-Control Studies , Cohort Studies , Female , Hip Prosthesis , Humans , Male , Middle Aged , Postoperative Complications/etiology , Risk Factors , Survival Rate , Time Factors , Treatment Outcome
4.
PLoS One ; 12(2): e0172203, 2017.
Article in English | MEDLINE | ID: mdl-28199377

ABSTRACT

BACKGROUND AND OBJECTIVES: Treatment of pelvic tumors remains challenging due to complex anatomy, poor oncological outcome and high complication rates. We sought to investigate the long-term oncological and surgical outcome of these patients. METHODS: Between 1980 and 2012, 147 patients underwent surgical treatment for pelvic sarcoma. Histological diagnosis was Chondrosarcoma in 54, Ewing's Sarcoma/PNET in 37, Osterosarcoma in 32 and others in 24 patients. Statistical analysis for the evaluation of oncological and surgical outcome was performed by applying Cox proportional hazards regression and Fine-Gray regression models for competing risk (CR) endpoints. RESULTS: The estimated overall survival (OS) to death was 80%, 45% and 37% at 1, 5 and 10 years, respectively. Univariate analyses revealed a statistically significant unadjusted influence of age age (p = 0.038; HR = 1.01), margin (p = 0.043; HR = 0.51) and grade (p = 0.001; HR = 2.27) on OS. Considering the multivariable model, grade (p = 0.005; HR = 3.04) and tumor volume (p = 0.014; HR = 1.18) presented themselves as independent prognostic factors on OS. CR analysis showed a cumulative incidence for major complication of 31% at 5 years. Endoprosthetic reconstruction had a higher risk for experiencing a major complication (p<0.0001) and infection (p = 0.001). CONCLUSIONS: Pelvic resections are still associated with a high incidence of complications. Patients with pelvic reconstruction and high volume tumors are especially at risk. Consequently, a cautious decision-making process is necessary when indicating pelvic reconstruction, although a restrictive approach to pelvic reconstruction is not necessarily reasonable when the other option is major amputation.


Subject(s)
Pelvic Neoplasms/surgery , Sarcoma/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Disease-Free Survival , Female , Hemipelvectomy/adverse effects , Humans , Infections/epidemiology , Infections/etiology , Male , Middle Aged , Neoplasm Recurrence, Local , Pelvic Neoplasms/diagnosis , Pelvic Neoplasms/mortality , Pelvic Neoplasms/therapy , Postoperative Complications , Prognosis , Proportional Hazards Models , Retrospective Studies , Risk , Sarcoma/diagnosis , Sarcoma/mortality , Sarcoma/therapy , Survival Rate , Treatment Outcome , Vascular Diseases/epidemiology , Vascular Diseases/etiology , Young Adult
5.
J Orthop Res ; 33(5): 765-70, 2015 May.
Article in English | MEDLINE | ID: mdl-25641201

ABSTRACT

Data on prognostic biomarkers in soft tissue sarcomas are scarce. The aim of the study was to define prognostic markers in patients with a liposarcoma, a subtype of sarcoma derived from adipose tissue. We restrospectively reviewed 85 patients with liposarcoma treated at our department from May 1994 to October 2011. Kaplan-Meier curves, uni-, and multivariable Cox proportional hazard models and competing risk analysis were performed to evaluate the association between putative biomarkers with disease-specific and overall survival. We observed a significant association between both alkalic phosphatase (ALP; subhazard ratio [SHR] per 1 unit increase: 1.35; 95%CI 1.10-1.65; p = 0.005) and C-reactive protein (CRP; SHR per 1 mg/dl increase: 2,57; 95%CI 1.36-4,86; p = 0.004) with disease-specific survival. Hemoglobin (Hb) (HR per 1 g/dl increase: 065; 95%CI 0.48-0.87; p = 0.003) was associated with overall survival. These associations prevailed after multivariable adjustment for AJCC tumor stage. This study identifies CRP and ALP as novel independent predictors of disease-specific survival in patients with liposarcoma.


Subject(s)
Alkaline Phosphatase/blood , C-Reactive Protein/metabolism , Hemoglobins/metabolism , Liposarcoma/blood , Adult , Aged , Aged, 80 and over , Austria/epidemiology , Biomarkers/blood , Female , Humans , Liposarcoma/mortality , Male , Middle Aged , Retrospective Studies , Young Adult
6.
Arch Orthop Trauma Surg ; 133(5): 707-12, 2013 May.
Article in English | MEDLINE | ID: mdl-23475053

ABSTRACT

INTRODUCTION: Evaluation of early cup movement is an important diagnostic tool to predict the likelihood of long-term implant loosening and clinical failure. The investigated cementless cup is clinically proven over 10 years, but there is a paucity of information that accurately describes the migration characteristics of this component. MATERIALS AND METHODS: We retrospectively analysed the clinical outcome and migration behaviour of 60 Pinnacle 100 shells after an average 3.8-year follow-up (range 2.1-5.4 years). For migration measurement, EBRA (Einzel-Bild-Röntgen-Analyse) digital software was applied. Clinical assessment was performed using the HHS, the UCLA score and the SF-36 health survey. RESULTS: The clinical outcome showed excellent results with a mean HHS of 95.4 (SD 7.1) and mean UCLA of 6.9 (SD 1.3). All implants were radiologically stable within the observation period and none of the cups was at risk for aseptical loosening. EBRA analysis revealed a mean total migration of 1.4 mm (SD 0.9) (95 % CI 1.1-1.6) at 3 years. Eight cups migrated more than 1 mm within the first three postoperative months, thereafter the migration curves flattened down. CONCLUSION: Surgeons may expect to find a variable amount of early migration when using the Pinnacle cup. To our knowledge, these are the first results, which show an early "impaction" of a cementless cup, followed by subsequent osseointegration. We believe that an appropriate long-term outcome of the investigated cup is ensured. The data of the present investigation will provide clinicians with useful baseline information with which to compare new cup designs.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Joint/surgery , Hip Prosthesis , Joint Diseases/surgery , Prosthesis Failure , Acetabulum/surgery , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Osseointegration , Prosthesis Design , Retrospective Studies
7.
Int Orthop ; 36(5): 941-7, 2012 May.
Article in English | MEDLINE | ID: mdl-22052477

ABSTRACT

PURPOSE: This trial was designed to evaluate the impact of physical characteristics such as body mass index, body weight and height on distal stem migration of a cementless femoral component, as the influence of obesity on the outcome of THA is still debated in literature and conflicting results have been found. METHODS: In this retrospective cohort study, migration patterns for 102 implants were analysed using the Einzel-Bild-Roentgen-Analyse (EBRA-FCA, femoral component analysis). In all cases the Vision 2000 stem was implanted and combined with the Duraloc acetabular component (DePuy, Warsaw, Indiana). RESULTS: The mean follow-up was 93 months. EBRA-FCA evaluations revealed a mean subsidence of 1.38 mm after two years, 2.06 mm after five and 2.24 mm after seven years. Five stems loosened aseptically. Correlation between increased migration over the whole period and aseptic loosening was highly significant (p < 0.001). Surgical technique had a significant influence on migration and stem stability (p = 0.002) but physical patient characteristics such as body weight over 75 kg and height over 165 cm also significantly influenced stem subsidence towards progressive migration (p = 0.001, p < 0.001). However, a high BMI did not trigger progressive stem migration (p = 0.87). Being of the male gender raised the odds for increased migration (p = 0.03). CONCLUSION: Physical characteristics such as body weight and height showed significant influence on migration patterns of this cementless femoral component. The operating surgeon should be aware that body weight above 75 kg and height over 165 cm may trigger increased stem migration and the surgeon should aim to fit these prostheses as tightly as possible. However this study demonstrates that a high BMI does not trigger progressive stem migration. Further investigations are needed to confirm our findings.


Subject(s)
Body Height , Body Weight , Hip Joint/surgery , Hip Prosthesis , Prosthesis Failure , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip , Body Mass Index , Cementation , Female , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications , Retrospective Studies , Treatment Outcome
8.
J Bone Joint Surg Am ; 91(2): 274-81, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19181970

ABSTRACT

BACKGROUND: Aseptic loosening is the most frequent cause of implant failure in total hip arthroplasty. While a direct link between aseptic loosening and periprosthetic bone loss remains elusive, there is plentiful evidence for a close association with early implant migration. The present trial was primarily designed to evaluate whether a single infusion of 4 mg of zoledronic acid prevented early implant migration in patients with osteonecrosis of the femoral head. METHODS: Fifty patients were consecutively enrolled to receive either zoledronic acid or saline solution after cementless total hip arthroplasty. Radiographs, biochemical parameters of bone turnover, and the Harris hip-rating score were determined preoperatively and at each follow-up examination at seven weeks, six months, one year, and yearly thereafter. The median follow-up period was 2.8 years. RESULTS: We found a significant subsidence of the stem of up to a mean (and standard deviation) of -1.2 +/- 0.6 mm at two years within the control group, and the cups had a mean medialization of 0.6 +/- 1.0 mm and a mean cranialization of 0.6 +/- 0.8 mm (p < 0.001). Treatment with zoledronic acid effectively minimized the migration of the cups in both the transverse and the vertical direction (mean, 0.15 +/- 0.6 mm and 0.06 +/- 0.6 mm, respectively; p < 0.05), while only a trend to decreased subsidence of the stem was detected. Finally, the Harris hip score rapidly increased over time in both treatment groups, although this increase was significantly more pronounced in the zoledronate-treated group than in the control group (analysis of variance, p = 0.008). CONCLUSIONS: A single infusion of zoledronic acid shows promise in improving initial fixation of a cementless implant, which may improve the clinical outcome of total hip arthroplasty in patients with osteonecrosis of the femoral head.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Density Conservation Agents/administration & dosage , Diphosphonates/administration & dosage , Femur Head Necrosis/surgery , Imidazoles/administration & dosage , Aged , Double-Blind Method , Female , Hip Prosthesis , Humans , Infusions, Intravenous , Male , Middle Aged , Prosthesis Failure , Zoledronic Acid
9.
Int Orthop ; 32(6): 791-4, 2008 Dec.
Article in English | MEDLINE | ID: mdl-17609953

ABSTRACT

The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters > or = 54 mm migrated significantly more than cups < 54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%).


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Foreign-Body Migration/diagnostic imaging , Prosthesis Failure , Adult , Aged , Aged, 80 and over , Equipment Design/adverse effects , Female , Follow-Up Studies , Hip Prosthesis/adverse effects , Humans , Male , Middle Aged , ROC Curve , Radiography , Sex Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...