Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Magn Reson ; 24(1): 66, 2022 11 24.
Article in English | MEDLINE | ID: mdl-36419059

ABSTRACT

BACKGROUND: Cardiac diffusion tensor imaging (cDTI) using cardiovascular magnetic resonance (CMR) is a novel technique for the non-invasive assessment of myocardial microstructure. Previous studies have shown myocardial infarction to result in loss of sheetlet angularity, derived by reduced secondary eigenvector (E2A) and reduction in subendocardial cardiomyocytes, evidenced by loss of myocytes with right-handed orientation (RHM) on helix angle (HA) maps. Myocardial strain assessed using feature tracking-CMR (FT-CMR) is a sensitive marker of sub-clinical myocardial dysfunction. We sought to explore the relationship between these two techniques (strain and cDTI) in patients at 3 months following ST-elevation MI (STEMI). METHODS: 32 patients (F = 28, 60 ± 10 years) underwent 3T CMR three months after STEMI (mean interval 105 ± 17 days) with second order motion compensated (M2), free-breathing spin echo cDTI, cine gradient echo and late gadolinium enhancement (LGE) imaging. HA maps divided into left-handed HA (LHM, - 90 < HA < - 30), circumferential HA (CM, - 30° < HA < 30°), and right-handed HA (RHM, 30° < HA < 90°) were reported as relative proportions. Global and segmental analysis was undertaken. RESULTS: Mean left ventricular ejection fraction (LVEF) was 44 ± 10% with a mean infarct size of 18 ± 12 g and a mean infarct segment LGE enhancement of 66 ± 21%. Mean global radial strain was 19 ± 6, mean global circumferential strain was - 13 ± - 3 and mean global longitudinal strain was - 10 ± - 3. Global and segmental radial strain correlated significantly with E2A in infarcted segments (p = 0.002, p = 0.011). Both global and segmental longitudinal strain correlated with RHM of infarcted segments on HA maps (p < 0.001, p = 0.003). Mean Diffusivity (MD) correlated significantly with the global infarct size (p < 0.008). When patients were categorised according to LVEF (reduced, mid-range and preserved), all cDTI parameters differed significantly between the three groups. CONCLUSION: Change in sheetlet orientation assessed using E2A from cDTI correlates with impaired radial strain. Segments with fewer subendocardial cardiomyocytes, evidenced by a lower proportion of myocytes with right-handed orientation on HA maps, show impaired longitudinal strain. Infarct segment enhancement correlates significantly with E2A and RHM. Our data has demonstrated a link between myocardial microstructure and contractility following myocardial infarction, suggesting a potential role for CMR cDTI to clinically relevant functional impact.


Subject(s)
Myocardial Infarction , ST Elevation Myocardial Infarction , Humans , Diffusion Tensor Imaging , Stroke Volume , Contrast Media , ST Elevation Myocardial Infarction/diagnostic imaging , Gadolinium , Ventricular Function, Left , Predictive Value of Tests , Myocardium , Myocardial Infarction/diagnostic imaging , Myocytes, Cardiac , Magnetic Resonance Spectroscopy
2.
Med Image Anal ; 50: 1-22, 2018 12.
Article in English | MEDLINE | ID: mdl-30173000

ABSTRACT

In this paper, we propose a novel continuum finite strain formulation of the equilibrium gap regularization for image registration. The equilibrium gap regularization essentially penalizes any deviation from the solution of a hyperelastic body in equilibrium with arbitrary loads prescribed at the boundary. It thus represents a regularization with strong mechanical basis, especially suited for cardiac image analysis. We describe the consistent linearization and discretization of the regularized image registration problem, in the framework of the finite elements method. The method is implemented using FEniCS & VTK, and distributed as a freely available python library. We show that the equilibrated warping method is effective and robust: regularization strength and image noise have minimal impact on motion tracking, especially when compared to strain-based regularization methods such as hyperelastic warping. We also show that equilibrated warping is able to extract main deformation features on both tagged and untagged cardiac magnetic resonance images.


Subject(s)
Finite Element Analysis , Heart/physiology , Humans , Magnetic Resonance Imaging
3.
Ann Biomed Eng ; 41(1): 131-41, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22805983

ABSTRACT

Energy-harvesting devices attract wide interest as power supplies of today's medical implants. Their long lifetime will spare patients from repeated surgical interventions. They also offer the opportunity to further miniaturize existing implants such as pacemakers, defibrillators or recorders of bio signals. A mass imbalance oscillation generator, which consists of a clockwork from a commercially available automatic wrist watch, was used as energy harvesting device to convert the kinetic energy from the cardiac wall motion to electrical energy. An MRI-based motion analysis of the left ventricle revealed basal regions to be energetically most favorable for the rotating unbalance of our harvester. A mathematical model was developed as a tool for optimizing the device's configuration. The model was validated by an in vitro experiment where an arm robot accelerated the harvesting device by reproducing the cardiac motion. Furthermore, in an in vivo experiment, the device was affixed onto a sheep heart for 1 h. The generated power in both experiments-in vitro (30 µW) and in vivo (16.7 µW)-is sufficient to power modern pacemakers.


Subject(s)
Bioelectric Energy Sources , Models, Theoretical , Myocardial Contraction , Animals , Female , Reproducibility of Results , Sheep
SELECTION OF CITATIONS
SEARCH DETAIL
...