Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Curr Probl Pediatr Adolesc Health Care ; 50(10): 100884, 2020 10.
Article in English | MEDLINE | ID: mdl-33069588

ABSTRACT

Musculoskeletal illness represents a significant portion of office visits to primary and urgent care clinicians. Despite this, little emphasis is placed on learning pediatric orthopaedics during medical school or residency. The focus of this paper is to provide a systematic approach to this general musculoskeletal physical exam and to assist in the recognition of what conditions are normal development and what conditions require observation, workup and referral to an experienced pediatric orthopaedist.


Subject(s)
Musculoskeletal Diseases/diagnosis , Musculoskeletal Diseases/therapy , Primary Health Care/organization & administration , Adolescent , Age Factors , Child , Foot Deformities/diagnosis , Foot Deformities/therapy , Humans , Physical Examination , Referral and Consultation
2.
Clin Orthop Relat Res ; 474(7): 1543-52, 2016 Jul.
Article in English | MEDLINE | ID: mdl-26847455

ABSTRACT

BACKGROUND: Placement and removal of fiberglass casts are among the more-common interventions performed in pediatric orthopaedic surgery offices. However, cast removal is associated with abrasive injuries and burns from the oscillating cast saw, and these injuries can occur even when the cast is removed by experienced personnel. It is unknown whether an added barrier, such as a safety strip, can mitigate injuries from blade-to-skin contact during cast removal with the oscillating saw. QUESTIONS/PURPOSES: We asked: (1) Can a safety strip provide a physical barrier during cast removal, decreasing blade-to-skin contact? (2) Does the safety strip lessen heat transfer? (3) Will the use of the safety strip prevent cast pressure from being released when the cast is split? METHODS: Standard long-arm fiberglass casts were removed by experienced and inexperienced healthcare personnel (n = 35) from life-sized pediatric models. A commercially available woven cast saw safety strip, commonly incorporated in waterproof cast constructs, was chosen as the protective strip. Each participant removed a cast with and without the safety strip present. All participants were blinded to the presence or absence of the safety strip at the time of cast removal. The number of touches was compared between cast removal with and without protective strips. A separate model was designed to assess prevention of heat transfer. Temperatures were recorded, using thermocouples, for three designated temperatures. Five to six trials were conducted at each designated temperature for each of two conditions, with and without the safety strip. Finally, to assess if the safety strip would prevent cast pressure from being released, a third model was used. Thirty standard short-arm casts were applied and removed from the arm models by one of the authors. Pressure data were collected from between the padding layers, in casts with and without the safety strip present, after application, univalving and bivalving each cast. RESULTS: Use of the safety strip reduced the number of simulated skin touches compared with casts removed without the safety strip, among experienced users (mean, 9.0 [range, 1-28] versus 0.1 [range, 0-1], mean ratio, 0.0012; 95% CI, 0.002-0.063; p < 0.001) and inexperienced users (mean, 8.5 [range, 0-31] versus 0.6 [range, 0-3], mean ratio, 0.07; 95% CI, 0.03-0.15; p < 0.001). The safety strips decreased heat transfer, preventing temperatures at the cast-skin interface from reaching 50 °C. Finally, after splitting the cast, with the numbers available, there was no increase in the pressure beneath the casts in those with the safety strip present (mean without, 0.23 [SD, 0.070] versus safety strip in the padding 0.20 [SD, 0.091] and safety strip on top padding, 0.21 [SD, 0.090]; p = 0.446 and p = 0.65 respectively). CONCLUSIONS: Our study showed the effectiveness of a safety strip in reducing simulated touches with the oscillating cast saw during cast splitting. Additional studies are warranted to investigate the clinical use and utility of the safety strip in practice. CLINICAL RELEVANCE: The findings of this study suggest that using safety strips in clinical practice could decrease blade-to-skin contact and therefore minimize cast saw injuries. However, validation of these findings in the clinical setting is necessary before drawing a definitive conclusion.


Subject(s)
Burns/prevention & control , Casts, Surgical , Device Removal/adverse effects , Device Removal/instrumentation , Protective Devices , Surgical Instruments/adverse effects , Upper Extremity/injuries , Wounds, Penetrating/prevention & control , Burns/etiology , Child , Energy Transfer , Female , Humans , Manikins , Materials Testing , Pressure , Protective Factors , Risk Factors , Wounds, Penetrating/etiology
3.
Clin J Sport Med ; 26(3): e71-3, 2016 May.
Article in English | MEDLINE | ID: mdl-26247550

ABSTRACT

A collegiate football athlete presented, on game day, with an acute onset of sore throat. He was afebrile, speaking in full sentences, without signs of respiratory distress. His examination was negative for lymphadenopathy or tonsillar enlargement or exudate. Twelve hours after initial presentation, he developed acute epiglottitis. He underwent urgent fiberoptic intubation and was empirically treated with broad-spectrum antibiotics and corticosteroids. Currently, there are no published reports of acute epiglottitis in athletes. Consequently, there is no evidence to guide return to play decisions. Return to play, following acute epiglottitis, should include resolution of symptoms and a graded return to play, taking into consideration the level of deconditioning the athlete experienced from hospitalization.


Subject(s)
Epiglottitis , Adolescent , Athletes , Humans , Male , Return to Sport
4.
Stud Health Technol Inform ; 196: 259-61, 2014.
Article in English | MEDLINE | ID: mdl-24732518

ABSTRACT

Appropriate pressure during the application of a cast is critical to provide adequate stabilization of fractures. Force-sensing resistors (FSR) were used to measure pressure during cast placement and removal. The data demonstrated a signature pattern of skin pressure during the different steps of cast placement and removal. This reproducible signal provides validity evidence for our model.


Subject(s)
Casts, Surgical , Clinical Competence , Device Removal/instrumentation , Immobilization/instrumentation , Patient Simulation , Transducers, Pressure , Equipment Design , Equipment Failure Analysis , Humans , Immobilization/methods , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL