Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Interv Card Electrophysiol ; 66(1): 27-38, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35072829

ABSTRACT

BACKGROUND: Arrhythmic death is very common among patients with structural heart disease, and it is estimated that in European countries, 1 per 1000 inhabitants yearly dies for sudden cardiac death (SCD), mainly as a result of ventricular arrhythmias (VA). The scar is the result of cardiac remodelling process that occurs in several cardiomyopathies, both ischemic and non-ischemic, and is considered the perfect substrate for re-entrant and non-re-entrant arrhythmias. METHODS: Our aim was to review published evidence on the histological and electrophysiological properties of myocardial scar and to review the central role of cardiac magnetic resonance (CMR) in assessing ventricular arrhythmias substrate and its potential implication in risk stratification of SCD. RESULTS: Scarring process affects both structural and electrical myocardial properties and paves the background for enhanced arrhythmogenicity. Non-uniform anisotropic conduction, gap junctions remodelling, source to sink mismatch and refractoriness dispersion are some of the underlining mechanisms contributing to arrhythmic potential of the scar. All these mechanisms lead to the initiation and maintenance of VA. CMR has a crucial role in the evaluation of patients suffering from VA, as it is considered the gold standard imaging test for scar characterization. Mounting evidences support the use of CMR not only for the definition of gross scar features, as size, localization and transmurality, but also for the identification of possible conducting channels suitable of discrete ablation. Moreover, several studies call out the CMR-based scar characterization as a stratification tool useful in selecting patients at risk of SCD and amenable to implantable cardioverter-defibrillator (ICD) implantation. CONCLUSIONS: Scar represents the substrate of ventricular arrhythmias. CMR, defining scar presence and its features, may be a useful tool for guiding ablation procedures and for identifying patients at risk of SCD amenable to ICD therapy.


Subject(s)
Cardiomyopathies , Defibrillators, Implantable , Humans , Cicatrix/diagnostic imaging , Cicatrix/pathology , Wind , Arrhythmias, Cardiac/diagnostic imaging , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/therapy , Death, Sudden, Cardiac/prevention & control , Risk Factors
2.
Cardiol Res Pract ; 2021: 9999412, 2021.
Article in English | MEDLINE | ID: mdl-34394984

ABSTRACT

BACKGROUND: Atrial fibrillation surgical radiofrequency ablation (AFSA) during mitral valve surgery (MVS) has almost completely superseded the Cox-Maze procedure for the treatment of atrial fibrillation. METHODS: We retrospectively analyzed 100 patients who underwent MVS + AFSA in our institution from January 2008 to June 2017. We compared the effectiveness of AFSA in patients who underwent LAA exclusion to those who did not. Moreover, we analyzed the role of preoperative AF duration (≤ or >1 year) and medial-lateral left atrial dimensions (ML-LAD) (≤ or >6 cm). The efficacy endpoint was freedom from AF at discharge and at 2-year follow-up. The safety endpoints were need of a permanent pacemaker (PMK), surgical re-exploration, occurrence of stroke, and left circumflex artery or esophageal lesions. RESULTS: Overall, the rate of AF freedom was 69% at discharge and 80% at 2-year follow-up. LAA exclusion did not influence AF freedom at 2-year follow-up, and 84.6% of patients who underwent LAA exclusion were in the sinus rythm (SR) at 2 year compared to 75% of those who did not receive LAA exclusion free from AF as well (p=0.230). AF duration ≤1 or >1 year did not influence sinus rhythm (SR) maintenance (85.7% vs. 75.8%; p=0.224), and in these two groups, LAA exclusion did not change the efficacy of AFSA. ML-LAD ≤ 6 cm was associated with better results in terms of SR maintenance. A statistically significant association between LAA exclusion and SR maintenance at 2-year follow-up (p=0.017) was found among patients with ML-LAD ≤ 6 cm. Complications included 7 cases of PMK implantation, 2 cases of surgical re-exploration, and 1 case of stroke. No circumflex artery or esophageal lesions occurred after surgical procedures. CONCLUSIONS: In our experience, AFSA during isolated MVS resulted in good outcomes in terms of SR maintenance and incidence of complications. AF duration ≤ 1 year did not influence results, while patients with ML-LAD ≤ 6 cm had significantly better results regarding SR at follow-up. In patients with ML-LAD ≤ 6 cm, LAA exclusion significantly increased the success rate of SR maintenance at 2-year follow-up.

SELECTION OF CITATIONS
SEARCH DETAIL
...