2.
Am J Hypertens ; 36(10): 532-535, 2023 09 15.
Article in English | MEDLINE | ID: mdl-37422909

ABSTRACT

BACKGROUND: The American Heart Association (AHA) recommends cuff sizes of blood pressure (BP) monitoring devices based on patient arm circumference, which is critical for accurate BP measurement. This study aimed to assess cuff size variation across validated BP devices and to examine the degree of alignment with the AHA recommendations. METHODS: Data on home BP devices were obtained from the US BP Validated Device Listing website and listed cuff sizes were compared against AHA recommendations: small adult (22-26 cm), adult (27-34 cm), large (35-44 cm), and extra-large (XL) (45-52 cm). RESULTS: There were 42 home validated BP devices from 13 manufacturers, and none offered cuffs that were aligned with the AHA recommendations. Over half of the devices (22, 52.4%) were compatible with only a broad-range cuff, generally excluding arm sizes larger than 44 cm. Only 5 devices from 4 manufacturers offered a cuff labeled "XL," and of these, only 3 devices had sizes that covered the AHA XL range. Terminology lacked consistency with manufacturers using: different labels to describe the same-sized cuffs (e.g., 22-42 cm was labeled "integrated," "standard," "adult," "large," and "wide range"); the same labels to describe differently sized cuffs (e.g., cuffs labeled "large" were sized 22-42 cm, 32-38 cm, 32-42 cm, 36-45 cm). CONCLUSIONS: Manufacturers of US home BP devices employ inconsistent terminologies and thresholds for cuff sizes, and sizes were not aligned with AHA recommendations. This lack of standardization could pose challenges for clinicians and patients attempting to select a properly sized cuff to support hypertension diagnosis and management.


Subject(s)
Arm , Hypertension , Adult , Humans , Blood Pressure/physiology , Blood Pressure Determination , Hypertension/diagnosis , Sphygmomanometers , Blood Pressure Monitoring, Ambulatory
3.
J Womens Health (Larchmt) ; 31(10): 1380-1386, 2022 10.
Article in English | MEDLINE | ID: mdl-36154466

ABSTRACT

More than 56 million women in the United States have hypertension, including almost one in five women of reproductive age. The prevalence of hypertensive disorders of pregnancy is on the rise, putting more women at risk for adverse pregnancy-related outcomes and atherosclerotic cardiovascular disease later in life. Hypertension can be better detected and controlled in women throughout their life course by supporting self-measured blood pressure monitoring. In this study, we present some potential strategies for strengthening our nation's ability to address hypertension in women focusing on pregnancy-related considerations for self-measured blood pressure monitoring.


Subject(s)
Blood Pressure Determination , Hypertension , Pregnancy , Female , Humans , Blood Pressure , Hypertension/diagnosis , Hypertension/epidemiology , Pregnancy Outcome , Monitoring, Physiologic