Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
2.
COPD ; 21(1): 2301549, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38348843

ABSTRACT

Exertional dyspnea, a key complaint of patients with chronic obstructive pulmonary disease (COPD), ultimately reflects an increased inspiratory neural drive to breathe. In non-hypoxemic patients with largely preserved lung mechanics - as those in the initial stages of the disease - the heightened inspiratory neural drive is strongly associated with an exaggerated ventilatory response to metabolic demand. Several lines of evidence indicate that the so-called excess ventilation (high ventilation-CO2 output relationship) primarily reflects poor gas exchange efficiency, namely increased physiological dead space. Pulmonary function tests estimating the extension of the wasted ventilation and selected cardiopulmonary exercise testing variables can, therefore, shed unique light on the genesis of patients' out-of-proportion dyspnea. After a succinct overview of the basis of gas exchange efficiency in health and inefficiency in COPD, we discuss how wasted ventilation translates into exertional dyspnea in individual patients. We then outline what is currently known about the structural basis of wasted ventilation in "minor/trivial" COPD vis-à-vis the contribution of emphysema versus a potential impairment in lung perfusion across non-emphysematous lung. After summarizing some unanswered questions on the field, we propose that functional imaging be amalgamated with pulmonary function tests beyond spirometry to improve our understanding of this deeply neglected cause of exertional dyspnea. Advances in the field will depend on our ability to develop robust platforms for deeply phenotyping (structurally and functionally), the dyspneic patients showing unordinary high wasted ventilation despite relatively preserved FEV1.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Humans , Pulmonary Disease, Chronic Obstructive/complications , Exercise Tolerance/physiology , Lung , Dyspnea/etiology , Spirometry , Exercise Test
3.
Eur J Appl Physiol ; 124(3): 1027-1036, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37803179

ABSTRACT

PURPOSE: Pathogen transmission during cardio-pulmonary exercise testing (CPET) is caused by carrier aerosols generated during respiration. METHODS: Ten healthy volunteers (age range: 34 ± 15; 4 females) were recruited to see if the physiological reactions to ramp-incremental CPET on a cycle ergometer were affected using an in-line filter placed between the mouthpiece and the flow sensor. The tests were in random order with or without an in-line bacterial/viral spirometer filter. The work rate aligned, time interpolated 10 s bin data were compared throughout the exercise period. RESULTS: From rest to peak exercise, filter use increased only minute ventilation ([Formula: see text]E) (Δ[Formula: see text]E = 1.56 ± 0.70 L/min, P < 0.001) and tidal volume (VT) (ΔVT = 0.10 ± 0.11 L, P = 0.014). Over the entire test, the slope of the residuals for [Formula: see text]CO2 was positive (0.035 ± 0.041 (ΔL/L), P = 0.027). During a ramp-incremental CPET in healthy subjects, an in-line filter increased [Formula: see text]E and VT but not metabolic rate. CONCLUSION: In conclusion, using an in-line filter is feasible, does not affect appreciably the physiological variables, and may mitigate risk of aerosol dispersion during CPET.


Subject(s)
Exercise Test , Respiration , Female , Humans , Young Adult , Adult , Middle Aged , Healthy Volunteers , Exercise/physiology , Tidal Volume , Oxygen Consumption/physiology
4.
Am J Physiol Regul Integr Comp Physiol ; 325(5): R433-R445, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37519253

ABSTRACT

Identification of the breathing cycle forms the basis of any breath-by-breath gas exchange analysis. Classically, the breathing cycle is defined as the time interval between the beginning of two consecutive inspiration phases. Based on this definition, several research groups have developed algorithms designed to estimate the volume and rate of gas transferred across the alveolar membrane ("alveolar gas exchange"); however, most algorithms require measurement of lung volume at the beginning of the ith breath (VLi-1; i.e., the end-expiratory lung volume of the preceding ith breath). The main limitation of these algorithms is that direct measurement of VLi-1 is challenging and often unavailable. Two solutions avoid the requirement to measure VLi-1 by redefining the breathing cycle. One method defines the breathing cycle as the time between two equal fractional concentrations of lung expired oxygen (Fo2) (or carbon dioxide; Fco2), typically in the alveolar phase, whereas the other uses the time between equal values of the Fo2/Fn2 (or Fco2/Fn2) ratios [i.e., the ratio of fractional concentrations of lung expired O2 (or CO2) and nitrogen (N2)]. Thus, these methods identify the breathing cycle by analyzing the gas fraction traces rather than the gas flow signal. In this review, we define the traditional approach and two alternative definitions of the human breathing cycle and present the rationale for redefining this term. We also explore the strengths and limitations of the available approaches and provide implications for future studies.


Subject(s)
Pulmonary Alveoli , Pulmonary Gas Exchange , Humans , Pulmonary Gas Exchange/physiology , Pulmonary Alveoli/physiology , Respiration , Lung/physiology , Breath Tests , Carbon Dioxide , Oxygen
6.
J Family Med Prim Care ; 12(1): 177-180, 2023 Jan.
Article in English | MEDLINE | ID: mdl-37025214

ABSTRACT

A routine clinical assessment in a 39-year-old male revealed liver function tests at 1.4-2.3 times the normal limit. He was asymptomatic, had no personal/family history of liver disease, and did not drink or use recreational drugs. He was in good physical condition and engaged in regular running and resistance exercise. Negative workup included tests for hepatitis A, B, and C, M-proteins, and antimitochondrial antibodies. Abdominal ultrasound was unremarkable. The patient was referred to a gastroenterologist who ordered repeat liver function tests (LFTs) and a liver biopsy. Before his follow-up assessment the patient abstained from exercise for seven days, after which all LFTs had normalized. The abnormal liver panel was thus likely due to exercise-induced muscle damage and/or changes in hepatocyte membrane permeability. Importantly, the diagnostic pathway did not include any assessment of muscle biomarkers (e.g., creatine kinase) or the patient's exercise training habits. This case highlights a knowledge gap in primary care regarding the possible causes of LFT abnormalities in young adults.

7.
Ann Am Thorac Soc ; 20(1): 38-46, 2023 01.
Article in English | MEDLINE | ID: mdl-35969416

ABSTRACT

Rationale: Chronic obstructive pulmonary disease (COPD) mortality risk is often estimated using the BODE (body mass index, obstruction, dyspnea, exercise capacity) index, including body mass index, forced expiratory volume in 1 second, dyspnea score, and 6-minute walk distance. Diffusing capacity of the lung for carbon monoxide (DlCO) is a potential predictor of mortality that reflects physiology distinct from that in the BODE index. Objectives: This study evaluated DlCO as a predictor of mortality using participants from the COPDGene study. Methods: We performed time-to-event analyses of individuals with COPD (former or current smokers with forced expiratory volume in 1 second/forced vital capacity < 0.7) and DlCO measurements from the COPDGene phase 2 visit. Cox proportional hazard methods were used to model survival, adjusting for age, sex, pack-years, smoking status, BODE index, computed tomography (CT) percent emphysema (low attenuation areas below -950 Hounsfield units), CT airway wall thickness, and history of cardiovascular or kidney diseases. C statistics for models with DlCO and BODE scores were used to compare discriminative accuracy. Results: Of 2,329 participants, 393 (16.8%) died during the follow-up period (median = 4.9 yr). In adjusted analyses, for every 10% decrease in DlCO percent predicted, mortality increased by 28% (hazard ratio = 1.28; 95% confidence interval, 1.17-1.41, P < 0.001). When compared with other clinical predictors, DlCO percent predicted performed similarly to BODE (C statistic DlCO = 0.68; BODE = 0.70), and the addition of DlCO to BODE improved its discriminative accuracy (C statistic = 0.71). Conclusions: Diffusing capacity, a measure of gas transfer, strongly predicted all-cause mortality in individuals with COPD, independent of BODE index and CT evidence of emphysema and airway wall thickness. These findings support inclusion of DlCO in prognostic models for COPD.


Subject(s)
Emphysema , Pulmonary Disease, Chronic Obstructive , Pulmonary Emphysema , Humans , Pulmonary Diffusing Capacity , Lung/diagnostic imaging , Forced Expiratory Volume , Dyspnea , Exercise Tolerance , Severity of Illness Index
8.
N Engl J Med ; 387(13): 1173-1184, 2022 09 29.
Article in English | MEDLINE | ID: mdl-36066078

ABSTRACT

BACKGROUND: Many persons with a history of smoking tobacco have clinically significant respiratory symptoms despite an absence of airflow obstruction as assessed by spirometry. They are often treated with medications for chronic obstructive pulmonary disease (COPD), but supporting evidence for this treatment is lacking. METHODS: We randomly assigned persons who had a tobacco-smoking history of at least 10 pack-years, respiratory symptoms as defined by a COPD Assessment Test score of at least 10 (scores range from 0 to 40, with higher scores indicating worse symptoms), and preserved lung function on spirometry (ratio of forced expiratory volume in 1 second [FEV1] to forced vital capacity [FVC] ≥0.70 and FVC ≥70% of the predicted value after bronchodilator use) to receive either indacaterol (27.5 µg) plus glycopyrrolate (15.6 µg) or placebo twice daily for 12 weeks. The primary outcome was at least a 4-point decrease (i.e., improvement) in the St. George's Respiratory Questionnaire (SGRQ) score (scores range from 0 to 100, with higher scores indicating worse health status) after 12 weeks without treatment failure (defined as an increase in lower respiratory symptoms treated with a long-acting inhaled bronchodilator, glucocorticoid, or antibiotic agent). RESULTS: A total of 535 participants underwent randomization. In the modified intention-to-treat population (471 participants), 128 of 227 participants (56.4%) in the treatment group and 144 of 244 (59.0%) in the placebo group had at least a 4-point decrease in the SGRQ score (difference, -2.6 percentage points; 95% confidence interval [CI], -11.6 to 6.3; adjusted odds ratio, 0.91; 95% CI, 0.60 to 1.37; P = 0.65). The mean change in the percent of predicted FEV1 was 2.48 percentage points (95% CI, 1.49 to 3.47) in the treatment group and -0.09 percentage points (95% CI, -1.06 to 0.89) in the placebo group, and the mean change in the inspiratory capacity was 0.12 liters (95% CI, 0.07 to 0.18) in the treatment group and 0.02 liters (95% CI, -0.03 to 0.08) in the placebo group. Four serious adverse events occurred in the treatment group, and 11 occurred in the placebo group; none were deemed potentially related to the treatment or placebo. CONCLUSIONS: Inhaled dual bronchodilator therapy did not decrease respiratory symptoms in symptomatic, tobacco-exposed persons with preserved lung function as assessed by spirometry. (Funded by the National Heart, Lung, and Blood Institute and others; RETHINC ClinicalTrials.gov number, NCT02867761.).


Subject(s)
Bronchodilator Agents , Pulmonary Disease, Chronic Obstructive , Adrenergic beta-2 Receptor Agonists/therapeutic use , Anti-Bacterial Agents/therapeutic use , Bronchodilator Agents/therapeutic use , Forced Expiratory Volume , Glucocorticoids/therapeutic use , Glycopyrrolate , Humans , Lung , Pulmonary Disease, Chronic Obstructive/drug therapy , Pulmonary Disease, Chronic Obstructive/etiology , Pulmonary Disease, Chronic Obstructive/physiopathology , Nicotiana/adverse effects , Treatment Outcome
9.
Chronic Obstr Pulm Dis ; 9(2): 226-236, 2022 Apr 29.
Article in English | MEDLINE | ID: mdl-35403415

ABSTRACT

Introduction: Autonomic dysfunction is common in chronic obstructive pulmonary disease (COPD), and worse autonomic function may be a marker of risk for acute exacerbations of COPD (AECOPD). Heart rate variability (HRV) is a measure of autonomic function. Our objective was to test whether lower (worse) HRV is a risk factor for AECOPD. Methods: We measured standard deviation of normal RR intervals (SDNN) and root mean square of successive RR interval differences (RMSSD) on 10-second electrocardiograms (ECGs) performed at screening and day 42 in participants in the Beta Blockers for the Prevention of Acute Exacerbations of COPD trial ( BLOCK-COPD), a placebo-controlled trial of metoprolol for prevention of AECOPD. We used Cox-proportional hazards models to test if these HRV measures were associated with risk of any AECOPD, and separately, hospitalized AECOPD. We tested associations using baseline HRV measures and incorporating HRV measures from day 42 as a time-varying covariate. We also tested for interactions with metoprolol assignment. Results: Of 532 trial participants, 529 (forced expiratory volume in 1 second [FEV1 ]41 ± 16.3 % predicted) were included in this analysis. We did not find a significant association between HRV measures and risk of AECOPD when all participants were analyzed together. There was a significant interaction between RMSSD and assignment to metoprolol on time to first hospitalized AECOPD; in the placebo group greater RMSSD was associated with a lower risk of hospitalized AECOPD (adjusted hazard ratio0.71, 95% confidence interval: 0.52 to 0.96, per 10 ms increase) but there was no association in the metoprolol group. Conclusions: Autonomic dysfunction as measured by HRV may be a risk factor for AECOPD. Future studies should analyze longer HRV recordings and their performance in broader samples of people with COPD, including those on beta-blockers.

10.
J Appl Physiol (1985) ; 132(5): 1145-1153, 2022 05 01.
Article in English | MEDLINE | ID: mdl-35323052

ABSTRACT

Exercise intolerance in chronic obstructive pulmonary disease (COPD) is associated with dyspnea, reduced inspiratory capacity (IC) and occurs with a neuromuscular "power reserve," i.e., an acute ability to increase isokinetic locomotor power. This power reserve is associated with resting forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) suggesting that treatments to target pulmonary function may protect neuromuscular performance and extend whole body exercise in COPD. We, therefore, tested whether combination long-acting ß-agonist and muscarinic antagonist bronchodilator therapy [long-acting muscarinic antagonist (LAMA) + long-acting ß-agonist (LABA); Stiolto Respimat] would ameliorate the decline in neuromuscular performance and increase endurance time during constant power cycling at 80% peak incremental power. Fourteen patients with COPD (4 female; 64 [58, 72] yr; FEV1 67% [56%, 75%] predicted; median [25th, 75th percentile]) participated in a randomized, placebo-controlled crossover trial (NCT02845752). Pulmonary function and cardiopulmonary exercise responses were assessed before and after 1 wk of treatment, with 2 wk washout between conditions. Performance fatigue was assessed using an ∼4-s maximal isokinetic cycling effort at preexercise, isotime, and intolerance. Isotime was the shorter exercise duration of the two treatment conditions. Significance was assessed using ANOVA with treatment as fixed factor and subject as random factor. FEV1 was greater with LAMA + LABA versus placebo (1.81 [1.58, 1.98] L vs. 1.72 [1.29, 1.99] L; P = 0.006), but IC at isotime, performance fatigue at isotime, and constant power endurance time were not different between conditions (each P > 0.05). A modest (∼95 mL) increase in FEV1 following 1 wk of combination LAMA + LABA treatment did not alleviate neuromuscular performance fatigue or enhance cycle exercise tolerance in patients with mild-to-severe COPD with largely preserved "static" lung volumes.NEW & NOTEWORTHY Bronchodilation is known to increase forced expiratory volume in 1 s (FEV1) and reduce hyperinflation in COPD. In a randomized controlled trial, we investigated whether combined inhaled long-acting ß-agonist and muscarinic antagonist would alleviate maximal voluntary neuromuscular performance fatigue or enhance maximal muscle activation during cycling in patients with COPD. Despite increased FEV1, combination bronchodilator therapy did not reduce neuromuscular performance fatigue or enhance muscle activity or exercise tolerance in patients with mild-to-severe COPD.


Subject(s)
Bronchodilator Agents , Pulmonary Disease, Chronic Obstructive , Benzoxazines , Bronchodilator Agents/pharmacology , Cross-Over Studies , Drug Combinations , Fatigue , Female , Humans , Male , Muscarinic Antagonists/therapeutic use , Pulmonary Disease, Chronic Obstructive/drug therapy , Tiotropium Bromide
11.
Respir Med ; 194: 106775, 2022 04.
Article in English | MEDLINE | ID: mdl-35203009

ABSTRACT

BACKGROUND: Lower heart rate (HR) increases during exercise and slower HR recovery (HRR) after exercise are markers of worse autonomic function that may be associated with risk of acute respiratory events (ARE). METHODS: Data from 6-min walk testing (6MWT) in COPDGene were used to calculate the chronotropic index (CI) [(HR immediately post 6MWT - resting HR)/((220 - age) - resting HR)] and HRR at 1 min after 6MWT completion. We used zero-inflated negative binomial regression to test associations of CI and HRR with rates of any ARE (requiring steroids and/or antibiotics) and severe ARE (requiring emergency department visit or hospitalization), among all participants and in spirometry subgroups (normal, chronic obstructive pulmonary disease [COPD], and preserved ratio with impaired spirometry). RESULTS: Among 4,484 participants, mean follow-up time was 4.1 years, and 1,966 had COPD. Among all participants, CI-6MWT was not associated with rate of any ARE [adjusted incidence rate ratio (aIRR) 0.98 (0.95-1.01)], but higher CI-6MWT was associated with lower rate of severe ARE [0.95 (0.92-0.99)]. Higher HRR was associated with a lower rate of both any ARE [0.97 (0.95-0.99)] and severe ARE [0.95 (0.92-0.98)]. Results were similar in the COPD spirometry subgroup. CONCLUSION: Heart rate measures derived from 6MWT tests may have utility in predicting risk of acute respiratory events and COPD exacerbations.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Walking , Exercise Test , Exercise Tolerance/physiology , Humans , Spirometry , Walk Test
12.
Int J Chron Obstruct Pulmon Dis ; 16: 2545-2560, 2021.
Article in English | MEDLINE | ID: mdl-34511898

ABSTRACT

BACKGROUND: Slow heart rate recovery (HRR) after exercise is associated with autonomic dysfunction and increased mortality. What HRR criterion at 1-minute after a 6-minute walk test (6MWT) best defines pulmonary impairment?. STUDY DESIGN AND METHODS: A total of 5008 phase 2 COPDGene (NCT00608764) participants with smoking history were included. A total of 2127 had COPD and, of these, 385 were followed-up 5-years later. Lung surgery, transplant, bronchiectasis, atrial fibrillation, heart failure and pacemakers were exclusionary. HR was measured from pulse oximetry at end-walk and after 1-min seated recovery. A receiver operator characteristic (ROC) identified optimal HRR cut-off. Generalized linear regression determined HRR association with spirometry, chest CT, symptoms and exacerbations. RESULTS: HRR after 6MWT (bt/min) was categorized in quintiles: ≤5 (23.0% of participants), 6-10 (20.7%), 11-15 (18.9%), 16-22 (18.5%) and ≥23 (18.9%). Compared to HRR≤5, HRR≥11 was associated with (p<0.001): lower pre-walk HR and 1-min post HR; greater end-walk HR; greater 6MWD; greater FEV1%pred; lower airway wall area and wall thickness. HRR was positively associated with FEV1%pred and negatively associated with airway wall thickness. An optimal HRR ≤10 bt/min yielded an area under the ROC curve of 0.62 (95% CI 0.58-0.66) for identifying FEV1<30%pred. HRR≥11 bt/min was the lowest HRR associated with consistently less impairment in 6MWT, spirometry and CT variables. In COPD, HRR≤10 bt/min was associated with (p<0.001): ≥2 exacerbations in the previous year (OR=1.76[1.33-2.34]); CAT≥10 (OR=1.42[1.18-1.71]); mMRC≥2 (OR=1.42[1.19-1.69]); GOLD 4 (OR=1.98[1.44-2.73]) and GOLD D (OR=1.51[1.18-1.95]). HRR≤10 bt/min was predicted COPD exacerbations at 5-year follow-up (RR=1.83[1.07-3.12], P=0.027). CONCLUSION: HRR≤10 bt/min after 6MWT in COPD is associated with more severe expiratory flow limitation, airway wall thickening, worse dyspnoea and quality of life, and future exacerbations, suggesting that an abnormal HRR≤10 bt/min after a 6MWT may be used in a comprehensive assessment in COPD for risk of severity, symptoms and future exacerbations.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Forced Expiratory Volume , Heart Rate , Humans , Lung , Pulmonary Disease, Chronic Obstructive/diagnosis , Quality of Life , Walk Test
13.
Chest ; 160(3): 803-804, 2021 09.
Article in English | MEDLINE | ID: mdl-34488956
14.
ERJ Open Res ; 7(3)2021 Jul.
Article in English | MEDLINE | ID: mdl-34322549

ABSTRACT

In COPD, anaemia is associated with increased morbidity, but the relationship between haemoglobin over its entire observed range and morbidity is poorly understood. Such an understanding could guide future therapeutic targeting of haemoglobin in COPD management. Leveraging the COPDGene study, we conducted a cross-sectional analysis of haemoglobin from COPD participants, examining symptoms, quality of life, functional performance, and acute exacerbations of COPD (AECOPD). Haemoglobin was analysed both as a continuous variable and categorised into anaemia, normal haemoglobin, and polycythaemia groups. Fractional polynomial modelling was used for continuous analyses; categorical models were multivariable linear or negative binomial regressions. Covariates included demographics, comorbidities, emphysema, diffusing capacity, and airflow obstruction. From 2539 participants, 366 (14%) were identified as anaemic and 125 (5%) as polycythaemic. Compared with normal haemoglobin, anaemia was significantly associated with increased symptoms (COPD Assessment Test score: p=0.006, modified Medical Research Council (mMRC) Dyspnoea Score: p=0.001); worse quality of life (St. George's Respiratory Questionnaire (SGRQ) score: p<0.001; Medical Outcomes Study Short Form 36-item Questionnaire (SF-36) General Health: p=0.002; SF-36 Physical Health: p<0.001), decreased functional performance (6-min walk distance (6MWD): p<0.001), and severe AECOPD (p=0.01), while polycythaemia was not. Continuous models, however, demonstrated increased morbidity at both ends of the haemoglobin distribution (p<0.01 for mMRC, SGRQ, SF-36 Physical Health, 6MWD, and severe AECOPD). Evaluating interactions, both diffusing capacity and haemoglobin were independently associated with morbidity. We present novel findings that haemoglobin derangements towards either extreme of the observed range are associated with increased morbidity in COPD. Further investigation is necessary to determine whether haemoglobin derangement drives morbidity or merely reflects systemic inflammation, and whether correcting haemoglobin towards the normal range improves morbidity.

15.
J Appl Physiol (1985) ; 131(1): 326-338, 2021 07 01.
Article in English | MEDLINE | ID: mdl-34013748

ABSTRACT

Assessing airway function during exercise provides useful information regarding mechanical properties of the airways and the extent of ventilatory limitation in COPD. The primary aim of this study was to use impulse oscillometry (IOS) to assess dynamic changes in airway impedance across a range of exercise intensities in patients with GOLD 1-4, before and after albuterol administration. A secondary aim was to assess the reproducibility of IOS measures during exercise. Fifteen patients with COPD (8 males/7 females; age = 66 ± 8 yr; prebronchodilator FEV1 = 54.3 ± 23.6%Pred) performed incremental cycle ergometry before and 90 min after inhaled albuterol. Pulmonary ventilation and gas exchange were measured continuously, and IOS-derived indices of airway impedance were measured every 2 min immediately preceding inspiratory capacity maneuvers. Test-retest reproducibility of exercise IOS was assessed as mean difference between replicate tests in five healthy subjects (3 males/2 females). At rest and during incremental exercise, albuterol significantly increased airway reactance (X5) and decreased airway resistance (R5, R5-R20), impedance (Z5), and end-expiratory lung volume (60% ± 12% vs. 58% ± 12% TLC, main effect P = 0.003). At peak exercise, there were moderate-to-strong associations between IOS variables and IC, and between IOS variables and concavity in the expiratory limb of the spontaneous flow-volume curve. Exercise IOS exhibited moderate reproducibility in healthy subjects which was strongest with R5 (mean diff. = -0.01 ± 0.05 kPa/L/s; ICC = 0.68), R5-R20 (mean diff. = -0.004 ± 0.028 kPa/L/s; ICC = 0.65), and Z5 (mean diff. = -0.006 ± 0.021 kPa/L/s; ICC = 0.69). In patients with COPD, exercise evoked increases in airway resistance and decreases in reactance that were ameliorated by inhaled bronchodilators. The technique of exercise IOS may aid in the clinical assessment of dynamic airway function during exercise.NEW & NOTEWORTHY This study provides a novel, mechanistic insight into dynamic airway function during exercise in COPD, before and after inhaled bronchodilators. The use of impulse oscillometry (IOS) to evaluate airway function is unique among exercise studies. We show strong correlations among IOS variables, dynamic hyperinflation, and shape-changes in the spontaneous expiratory flow-volume curve. This approach may aid in the clinical assessment of airway function during exercise.


Subject(s)
Bronchodilator Agents , Pulmonary Disease, Chronic Obstructive , Aged , Airway Resistance , Female , Forced Expiratory Volume , Humans , Male , Middle Aged , Oscillometry , Pulmonary Disease, Chronic Obstructive/drug therapy , Reproducibility of Results , Spirometry
16.
J Appl Physiol (1985) ; 130(6): 2009-2018, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33914661

ABSTRACT

We investigated whether dual bronchodilator therapy (glycopyrrolate/formoterol fumarate; GFF; Bevespi Aerosphere) would increase exercise tolerance during a high-intensity constant work rate exercise test (CWRET) and the relative contributions of dead space ventilation (VD/VT) and dynamic hyperinflation (change in inspiratory capacity) to exercise limitation in chronic obstructive pulmonary disease (COPD). In all, 48 patients with COPD (62.9 ± 7.6 yrs; 33 male; GOLD spirometry stage 1/2/3/4, n = 2/35/11/0) performed a randomized, double blind, placebo (PL) controlled, two-period crossover, single-center trial. Gas exchange and inspiratory capacity (IC) were assessed during cycle ergometry at 80% incremental exercise peak work rate. Transcutaneous [Formula: see text] (Tc[Formula: see text]) measurement was used for VD/VT estimation. Baseline postalbuterol forced expiratory volume in 1 s (FEV1) was 1.86 ± 0.58 L (63.6% ± 13.9 predicted). GFF increased FEV1 by 0.18 ± 0.21 L relative to placebo (PL; P < 0.001). CWRET endurance time was greater after GFF vs. PL (383 ± 184 s vs. 328 ± 115 s; difference 55 ± 125 s; P = 0.013; confidence interval: 20-90 s), a 17% increase. IC on GFF was above placebo IC at all time points and fell less with GFF vs. PL (P ≤ 0.0001). Isotime tidal volume (1.54 ± 0.50 vs. 1.47 ± 0.45 L; P = 0.022) and ventilation (52.9 ± 19.9 vs. 51.0 ± 18.9 L/min; P = 0.011) were greater, and respiratory rate was unchanged (34.9 ± 9.2 vs. 35.1 ± 8.0 br/min, P = 0.865). Isotime VD/VT did not differ between groups (GFF 0.28 ± 0.08 vs. PL 0.27 ± 0.09; P = 0.926). GFF increased exercise tolerance in patients with COPD, and the increase was accompanied by attenuated dynamic hyperinflation without altering VD/VT.NEW & NOTEWORTHY This study was a randomized clinical trial (NCT03081156) that collected detailed physiology data to investigate the effect of dual bronchodilator therapy on exercise tolerance in COPD, and additionally to determine the relative contributions of changes in dead space ventilation (VD/VT) and dynamic hyperinflation to alterations in exercise limitation. We utilized a unique noninvasive method to assess VD/VT (transcutaneous carbon dioxide, Tc[Formula: see text]) and found that dual bronchodilators yielded a moderate improvement in exercise tolerance. Importantly, attenuation of dynamic hyperinflation rather than change in dead space ventilation was the most important contributor to exercise tolerance improvement.


Subject(s)
Bronchodilator Agents , Pulmonary Disease, Chronic Obstructive , Bronchodilator Agents/therapeutic use , Double-Blind Method , Exercise Tolerance , Forced Expiratory Volume , Glycopyrrolate/therapeutic use , Humans , Male , Pulmonary Disease, Chronic Obstructive/drug therapy
17.
Ann Am Thorac Soc ; 18(11): 1795-1802, 2021 11.
Article in English | MEDLINE | ID: mdl-33784233

ABSTRACT

Rationale: The chronotropic index quantifies the proportion of the expected heart rate increase that is attained during exercise. The relationship between the chronotropic index and acute exacerbations of chronic obstructive pulmonary disease (AECOPDs) has not been evaluated. Objectives: To determine whether a higher chronotropic index during a 6-minute walk (CI-6MW) is associated with lower risk of AECOPD and whether the CI-6MW is a marker of susceptibility to adverse effects of metoprolol in chronic obstructive pulmonary disease (COPD). Methods: We analyzed data from the BLOCK COPD (Beta-Blockers for the Prevention of AECOPDs) trial. We used Cox proportional hazards models to investigate the relationship between the CI-6MW and the time to AECOPDs. We also tested for interactions between study group assignment (metoprolol vs. placebo) and the CI-6MW on the time to AECOPDs. Results: Four hundred seventy-seven participants with exacerbation-prone COPD (mean forced expiratory volume in 1 second, 41% of predicted) were included in this analysis. A higher CI-6MW was independently associated with a decreased risk of AECOPDs of any severity (adjusted hazard ratio per 0.1 increase in CI-6MW of 0.88; 95% confidence interval, 0.80-0.96) but was not independently associated with AECOPDs requiring hospitalization (adjusted hazard ratio, 0.94; 95% confidence interval, 0.81-1.05). There was a significant interaction by treatment assignment, and in a stratified analysis, the protective effects of a higher CI-6MW on AECOPDs were negated by metoprolol use. Conclusions: A higher CI-6MW is associated with a decreased risk of AECOPDs and may be an indicator of susceptibility to the adverse effects of metoprolol.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Disease Progression , Forced Expiratory Volume , Hospitalization , Humans , Pulmonary Disease, Chronic Obstructive/drug therapy , Respiratory Function Tests
18.
COPD ; 18(1): 16-25, 2021 02.
Article in English | MEDLINE | ID: mdl-33455452

ABSTRACT

Gas exchange inefficiency and dynamic hyperinflation contributes to exercise limitation in chronic obstructive pulmonary disease (COPD). It is also characterized by an elevated fraction of physiological dead space (VD/VT). Noninvasive methods for accurate VD/VT assessment during exercise in patients are lacking. The current study sought to compare transcutaneous PCO2 (TcPCO2) with the gold standard-arterial PCO2 (PaCO2)-and other available methods (end tidal CO2 and the Jones equation) for estimating VD/VT during incremental exercise in COPD. Ten COPD patients completed a symptom limited incremental cycle exercise. TcPCO2 was measured by a heated electrode on the ear-lobe. Radial artery blood was collected at rest, during unloaded cycling (UL) and every minute during exercise and recovery. Ventilation and gas exchange were measured breath-by-breath. Bland-Altman analysis examined agreement of PCO2 and VD/VT calculated using PaCO2, TcPCO2, end-tidal PCO2 (PETCO2) and estimated PaCO2 by the Jones equation (PaCO2-Jones). Lin's Concordance Correlation Coefficient (CCC) was assessed. 114 measurements were obtained from the 10 COPD subjects. The bias between TcPCO2 and PaCO2 was 0.86 mmHg with upper and lower limit of agreement ranging -2.28 mmHg to 3.99 mmHg. Correlation between TcPCO2 and PaCO2 during rest and exercise was r2=0.907 (p < 0.001; CCC = 0.941) and VD/VT using TcPCO2 vs. PaCO2 was r2=0.958 (p < 0.0001; CCC = 0.967). Correlation between PaCO2-Jones and PETCO2 vs. PaCO2 were r2=0.755, 0.755, (p < 0.001; CCC = 0.832, 0.718) and for VD/VT calculation (r2=0.793, 0.610; p < 0.0001; CCC = 0.760, 0.448), respectively. The results support the accuracy of TcPCO2 to reflect PaCO2 and calculate VD/VT during rest and exercise, but not in recovery, in COPD patients, enabling improved accuracy of noninvasive assessment of gas exchange inefficiency during incremental exercise testing.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Carbon Dioxide , Exercise , Exercise Test , Humans , Pulmonary Gas Exchange , Tidal Volume
19.
Chest ; 158(4): 1781-1782, 2020 10.
Article in English | MEDLINE | ID: mdl-33036092
SELECTION OF CITATIONS
SEARCH DETAIL
...