Int J Cardiovasc Imaging ; 40(4): 931-940, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38386192

ABSTRACT

Virtual mono-energetic images (VMI) using dual-layer computed tomography (DLCT) enable substantial contrast medium (CM) reductions. However, the combined impact of patient size, tube voltage, and heart rate (HR) on VMI of coronary CT angiography (CCTA) remains unknown. This phantom study aimed to assess VMI levels achieving comparable contrast-to-noise ratio (CNR) in CCTA at 50% CM dose across varying tube voltages, patient sizes, and HR, compared to the reference protocol (100% CM dose, conventional at 120 kVp). A 5 mm artificial coronary artery with 100% (400 HU) and 50% (200 HU) iodine CM-dose was positioned centrally in an anthropomorphic thorax phantom. Horizontal coronary movement was matched to HR (at 0, < 60, 60-75, > 75 bpm), with varying patient sizes simulated using phantom extension rings. Raw data was acquired using a clinical CCTA protocol at 120 and 140 kVp (five repetitions). VMI images (40-70 keV, 5 keV steps) were then reconstructed; non-overlapping 95% CNR confidence intervals indicated significant differences from the reference. Higher CM-dose, reduced VMI, slower HR, higher tube voltage, and smaller patient sizes demonstrated a trend of higher CNR. Regardless of HR, patient size, and tube voltage, no significant CNR differences were found compared to the reference, with 100% CM dose at 60 keV, or 50% CM dose at 40 keV. DLCT reconstructions at 40 keV from 120 to 140 kVp acquisitions facilitate 50% CM dose reduction for various patient sizes and HR with equivalent CNR to conventional CCTA at 100% CM dose, although clinical validation is needed.


Subject(s)
Computed Tomography Angiography , Contrast Media , Coronary Angiography , Coronary Vessels , Heart Rate , Phantoms, Imaging , Predictive Value of Tests , Radiation Dosage , Humans , Coronary Angiography/instrumentation , Coronary Angiography/methods , Computed Tomography Angiography/instrumentation , Contrast Media/administration & dosage , Coronary Vessels/diagnostic imaging , Radiation Exposure/prevention & control , Radiographic Image Interpretation, Computer-Assisted , Body Size
3.
Eur J Radiol ; 124: 108826, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32000074

ABSTRACT

PURPOSE: Chronic kidney disease (CKD) is prevalent in transcatheter aortic valve replacement (TAVR) candidates, leading to concerns regarding contrast medium (CM) safety. We evaluated (a) the impact of low-CM imaging on pre-TAVR measurements and (b) postcontrast acute kidney injury (PC-AKI) prevalence after dual-source computed tomography (DSCT) in TAVR candidates. METHODS: All TAVR candidates with CKD (SCr≥1.5 mg/dL) who underwent weight-based low-CM, low-pitch helical 3rd-generation DSCT in a one-year period were included, and matched to standard-CM, non-CKD controls (N = 50). Image quality (IQ) and pre-TAVR measurement interobserver variability were evaluated. Renal function change and PC-AKI were studied in the entire TAVR cohort, irrespective of scan mode (N = 153). RESULTS: Low-CM in CKD (N = 25) was performed with median 68 mL CM [52-87], 90 kV [80-90] and SCr 1.6 mg/dL [1.5-1.9], and standard-CM without CKD with median 116 mL CM [96-134], 100 kV [90-110] and SCr 1.0 mg/dL [0.9-1.1](P < 0.00). Low-CM IQ was good, though lower compared with standard-CM (P < 0.02). Interobserver measurement reliability was excellent (ICCs>0.85). Interobserver-agreement was lower in low-CM, causing prosthesis size disagreement in 5/25 (kappa-0.73) versus 0/25 with standard-CM (kappa-1.00), and transfemoral eligibility disagreement in 4/25 (kappa-0.68) versus 2/25 (kappa-0.84), respectively. Mean 1-month SCr-change in the low-CM TAVR cohort (N = 35) was -1 % [-12 to +7 %] and in standard-CM (N = 118) 0 % [-8 to +10 %](P > 0.3). PC-AKI occurred in none. CONCLUSION: Low-CM third-generation-DSCT achieves good IQ in TAVR candidates with CKD, and seems safe, with no apparent renal function deterioration or prevalence of PC-AKI. However, standard-CM protocols in non-CKD patients provide higher measurement reproducibility. Low-CM protocols should therefore be reserved for patients at high risk for PC-AKI.


Subject(s)
Aortic Valve/diagnostic imaging , Computed Tomography Angiography/methods , Contrast Media , Radiographic Image Enhancement/methods , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Aged, 80 and over , Aortic Valve/surgery , Female , Humans , Male , Observer Variation , Reproducibility of Results , Retrospective Studies
4.
PLoS One ; 12(1): e0171138, 2017.
Article in English | MEDLINE | ID: mdl-28141852

ABSTRACT

BACKGROUND: Complications might occur after great vessel stent implantation in children. Therefore follow-up using imaging is warranted. PURPOSE: To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children. MATERIAL AND METHODS: Five different large vessel stents were evaluated in an in-vitro setting. All stents were expanded to the maximal vendor recommended diameter (20mm; n = 4 or 10mm; n = 1), placed in an anthropomorphic chest phantom and imaged with a 256-slice CT-scanner. MRI images were acquired at 1.5T using a multi-slice T2-weighted turbo spin echo, an RF-spoiled three-dimensional T1-weighted Fast Field Echo and a balanced turbo field echo 3D sequence. Two blinded observers assessed stent lumen visibility (measured diameter/true diameter *100%) in the center and at the outlets of the stent. Reproducibility of diameter measurements was evaluated using the intraclass correlation coefficient for reliability and 95% limits of agreement for agreement analysis. RESULTS: Median stent lumen visibility was 88 (IQR 86-90)% with CT for all stents at both the center and outlets. With MRI, the T2-weighted turbo spin echo sequence was preferred which resulted in 82 (78-84%) stent lumen visibility. Interobserver reliability and agreement was good for both CT (ICC 0.997, mean difference -0.51 [-1.07-0.05] mm) and MRI measurements (ICC 0.951, mean difference -0.05 [-2.52 --2.41] mm). CONCLUSION: Good in-stent lumen visibility was achievable in this in-vitro study with both CT and MRI in different great vessel stents. Overall reliability was good with clinical acceptable limits of agreement for both CT and MRI. However, common conditions such as in-stent stenosis and associated aneurysms were not tested in this in-vitro study, limiting the value of the in-vitro study.


Subject(s)
Blood Vessels/diagnostic imaging , Imaging, Three-Dimensional , Magnetic Resonance Imaging/methods , Stents , Tomography, X-Ray Computed/methods , Child , Humans , Observer Variation , Reproducibility of Results
5.
Ceska Gynekol ; 81(4): 283-285, 2016.
Article in Czech | MEDLINE | ID: mdl-27882750

ABSTRACT

OBJECTIVE: To describe hear-attack on crystal meth addicted pregnant woman. DESIGN: Case report. CONCLUSION: Acute heart-attack during pregnancy means unexpected obstetric complication. The consequences could be fatal for the mother and the fetus. Although good delivery management and treatment could reduce morbidity and mortality to a minimum.


Subject(s)
Amphetamine-Related Disorders/complications , Myocardial Infarction/etiology , Pregnancy Complications , Adult , Female , Humans , Pregnancy