Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 37
Filter
Add more filters











Publication year range
1.
Front Cardiovasc Med ; 9: 878266, 2022.
Article in English | MEDLINE | ID: mdl-36386362

ABSTRACT

Hypoplastic left heart syndrome (HLHS) is a complex congenital heart condition in which a neonate is born with an underdeveloped left ventricle and associated structures. Without palliative interventions, HLHS is fatal. Treatment typically includes medical management at the time of birth to maintain patency of the ductus arteriosus, followed by three palliative procedures: most commonly the Norwood procedure, bidirectional cavopulmonary shunt, and Fontan procedures. With recent advances in surgical management of HLHS patients, high survival rates are now obtained at tertiary treatment centers, though adverse neurodevelopmental outcomes remain a clinical challenge. While surgical management remains the standard of care for HLHS patients, innovative treatment strategies continue to be developing. Important for the development of new strategies for HLHS patients is an understanding of the genetic basis of this condition. Another investigational strategy being developed for HLHS patients is the injection of stem cells within the myocardium of the right ventricle. Recent innovations in tissue engineering and regenerative medicine promise to provide important tools to both understand the underlying basis of HLHS as well as provide new therapeutic strategies. In this review article, we provide an overview of HLHS, starting with a historical description and progressing through a discussion of the genetics, surgical management, post-surgical outcomes, stem cell therapy, hemodynamics and tissue engineering approaches.

2.
NPJ Microgravity ; 8(1): 39, 2022 Sep 09.
Article in English | MEDLINE | ID: mdl-36085153

ABSTRACT

Long-duration spaceflight poses multiple hazards to human health, including physiological changes associated with microgravity. The hemodynamic adaptations occurring upon entry into weightlessness have been associated with retrograde stagnant flow conditions and thromboembolic events in the venous vasculature but the impact of microgravity on cerebral arterial hemodynamics and function remains poorly understood. The objective of this study was to quantify the effects of microgravity on hemodynamics and wall shear stress (WSS) characteristics in 16 carotid bifurcation geometries reconstructed from ultrasonography images using computational fluid dynamics modeling. Microgravity resulted in a significant 21% increase in flow stasis index, a 22-23% decrease in WSS magnitude and a 16-26% increase in relative residence time in all bifurcation branches, while preserving WSS unidirectionality. In two anatomies, however, microgravity not only promoted flow stasis but also subjected the convex region of the external carotid arterial wall to a moderate increase in WSS bidirectionality, which contrasted with the population average trend. This study suggests that long-term exposure to microgravity has the potential to subject the vasculature to atheroprone hemodynamics and this effect is modulated by subject-specific anatomical features. The exploration of the biological impact of those microgravity-induced WSS aberrations is needed to better define the risk posed by long spaceflights on cardiovascular health.

3.
Comput Biol Med ; 146: 105613, 2022 07.
Article in English | MEDLINE | ID: mdl-35751200

ABSTRACT

PURPOSE: Discrete subaortic stenosis (DSS) is an obstructive cardiac disease caused by a membranous lesion in the left ventricular (LV) outflow tract (LVOT). Although its etiology is unknown, the higher prevalence of DSS in LVOT anatomies featuring a steep aortoseptal angle (AoSA) suggests a potential role for hemodynamics. Therefore, the objective of this study was to quantify the impact of AoSA steepening on the LV three-dimensional (3D) hemodynamic stress environment. METHODS: A 3D LV model reconstructed from cardiac cine-magnetic resonance imaging was connected to four LVOT geometrical variations spanning the clinical AoSA range (115°-160°). LV hemodynamic stresses were characterized in terms of cycle-averaged pressure, temporal shear magnitude (TSM), and oscillatory shear index. The wall shear stress (WSS) topological skeleton was further analyzed by computing the scaled divergence of the WSS vector field. RESULTS: AoSA steepening caused an increasingly perturbed subaortic flow marked by LVOT flow skewness and complex 3D secondary flow patterns. These disturbances generated WSS overloads (>45% increase in TSM vs. 160° model) on the inferior LVOT wall, and increased WSS contraction (>66% decrease in WSS divergence vs. 160° model) in regions prone to DSS membrane formation. CONCLUSIONS: AoSA steepening generated substantial hemodynamic stress abnormalities in LVOT regions prone to DSS formation. Further studies are needed to assess the possible impact of such mechanical abnormalities on the tissue and cellular responses.


Subject(s)
Heart Ventricles , Hemodynamics , Constriction, Pathologic , Diagnostic Imaging , Heart Ventricles/diagnostic imaging , Humans , Stress, Mechanical
4.
Cardiovasc Eng Technol ; 12(6): 559-575, 2021 12.
Article in English | MEDLINE | ID: mdl-33432514

ABSTRACT

PURPOSE: Discrete subaortic stenosis (DSS) is a left-ventricular outflow tract (LVOT) obstruction caused by a membranous lesion. DSS is associated with steep aortoseptal angles (AoSAs) and is a risk factor for aortic regurgitation (AR). However, the etiology of AR secondary to DSS remains unknown. This study aimed at quantifying computationally the impact of AoSA steepening and DSS on aortic valve (AV) hemodynamics and AR. METHODS: An LV geometry reconstructed from cine-MRI data was connected to an AV geometry to generate a unified 2D LV-AV model. Six geometrical variants were considered: unobstructed (CTRL) and DSS-obstructed LVOT (DSS), each reflecting three AoSA variations (110°, 120°, 130°). Fluid-structure interaction simulations were run to compute LVOT flow, AV leaflet dynamics, and regurgitant fraction (RF). RESULTS: AoSA steepening and DSS generated vortex dynamics alterations and stenotic flow conditions. While the CTRL-110° model generated the highest degree of leaflet opening asymmetry, DSS preferentially altered superior leaflet kinematics, and caused leaflet-dependent alterations in systolic fluttering. LVOT steepening and DSS subjected the leaflets to increasing WSS overloads (up to 94% increase in temporal shear magnitude), while DSS also increased WSS bidirectionality on the inferior leaflet belly (+ 0.30-point in oscillatory shear index). Although AoSA steepening and DSS increased diastolic transvalvular backflow, regurgitant fractions (RF < 7%) remained below the threshold defining clinical mild AR. CONCLUSIONS: The mechanical interactions between AV leaflets and LVOT steepening/DSS hemodynamic derangements do not cause AR. However, the leaflet WSS abnormalities predicted in those anatomies provide new support to a mechanobiological etiology of AR secondary to DSS.


Subject(s)
Aortic Valve Insufficiency , Discrete Subaortic Stenosis , Heart Defects, Congenital , Aortic Valve/diagnostic imaging , Hemodynamics , Humans
5.
Article in English | MEDLINE | ID: mdl-32175314

ABSTRACT

Discrete subaortic stenosis (DSS) is an obstruction of the left ventricular outflow tract (LVOT) due to the formation of a fibromuscular membrane upstream of the aortic valve. DSS is a major risk factor for aortic regurgitation (AR), which often persists after surgical resection of the membrane. While the etiology of DSS and secondary AR is largely unknown, the frequent association between DSS and aortoseptal angle (AoSA) abnormalities has supported the emergence of a mechanobiological pathway by which hemodynamic stress alterations on the septal wall could trigger a biological cascade leading to fibrosis and membrane formation. The resulting LVOT flow disturbances could activate the valve endothelium and contribute to AR. In an effort to assess this hypothetical mechano-etiology, this study aimed at isolating computationally the effects of AoSA abnormalities on septal wall shear stress (WSS), and the impact of DSS on LVOT hemodynamics. Two-dimensional computational fluid dynamics models featuring a normal AoSA (N-LV), a steep AoSA (S-LV), and a steep AoSA with a DSS lesion (DSS-LV) were designed to compute the flow in patient-specific left ventricles (LVs). Boundary conditions consisted of transient velocity profiles at the mitral inlet and LVOT outlet, and patient-specific LV wall motion. The deformation of the DSS lesion was computed using a two-way fluid-structure interaction modeling strategy. Turbulence was accounted for via implementation of the k-ω turbulence model. While the N-LV and S-LV models generated similar LVOT flow characteristics, the DSS-LV model resulted in an asymmetric LVOT jet-like structure, subaortic stenotic conditions (up to 2.4-fold increase in peak velocity, 45% reduction in effective jet diameter vs. N-LV/S-LV), increased vorticity (2.8-fold increase) and turbulence (5- and 3-order-of-magnitude increase in turbulent kinetic energy and Reynolds shear stress, respectively). The steep AoSA subjected the septal wall to a 23% and 69% overload in temporal shear magnitude and gradient, respectively, without any substantial change in oscillatory shear index. This study reveals the existence of WSS overloads on septal wall regions prone to DSS lesion formation in steep LVOTs, and the development of highly turbulent, stenotic and asymmetric flow in DSS LVOTs, which support a possible mechano etiology for DSS and secondary AR.

7.
Cardiovasc Eng Technol ; 10(3): 531-542, 2019 09.
Article in English | MEDLINE | ID: mdl-31309526

ABSTRACT

PURPOSE: The cardiovascular endothelium experiences pulsatile and multidirectional fluid wall shear stress (WSS). While the effects of non-physiologic WSS magnitude and pulsatility on cardiovascular function have been studied extensively, the impact of directional abnormalities remains unknown due to the challenge to replicate this characteristic in vitro. To address this gap, this study aimed at designing a bioreactor capable of subjecting cardiovascular tissue to time-varying WSS magnitude and directionality. METHODS: The device consisted of a modified cone-and-plate bioreactor. The cone rotation generates a fluid flow subjecting tissue to desired WSS magnitude, while WSS directionality is achieved by altering the alignment of the tissue relative to the flow at each instant of time. Computational fluid dynamics was used to verify the device ability to replicate the native WSS of the proximal aorta. Cone and tissue mount velocities were determined using an iterative optimization procedure. RESULTS: Using conditions derived from cone-and-plate theory, the initial simulations yielded root-mean-square errors of 22.8 and 8.4% in WSS magnitude and angle, respectively, between the predicted and the target signals over one cycle, relative to the time-averaged target values. The conditions obtained after two optimization iterations reduced those errors to 3.5 and 0.5%, respectively, and generated 0.2% and 0.01% difference in time-averaged WSS magnitude and angle, respectively, relative to the target waveforms. CONCLUSIONS: A bioreactor capable of generating simultaneously desired time-varying WSS magnitude and directionality was designed and validated computationally. The ability to subject tissue to in vivo-like WSS will provide new insights into cardiovascular mechanobiology and disease.


Subject(s)
Bioreactors , Computer Simulation , Computer-Aided Design , Endothelium, Vascular/physiology , Hemodynamics , Models, Cardiovascular , Equipment Design , Hydrodynamics , Reproducibility of Results , Stress, Mechanical , Time Factors , Tissue Culture Techniques
8.
Front Cardiovasc Med ; 5: 122, 2018.
Article in English | MEDLINE | ID: mdl-30320123

ABSTRACT

Discrete subaortic stenosis (DSS) is a congenital heart disease that results in the formation of a fibro-membranous tissue, causing an increased pressure gradient in the left ventricular outflow tract (LVOT). While surgical resection of the membrane has shown some success in eliminating the obstruction, it poses significant risks associated with anesthesia, sternotomy, and heart bypass, and it remains associated with a high rate of recurrence. Although a genetic etiology had been initially proposed, the association between DSS and left ventricle (LV) geometrical abnormalities has provided more support to a hemodynamic etiology by which congenital or post-surgical LVOT geometric derangements could generate abnormal shear forces on the septal wall, triggering in turn a fibrotic response. Validating this hypothetical etiology and understanding the mechanobiological processes by which altered shear forces induce fibrosis in the LVOT are major knowledge gaps. This perspective paper describes the current state of knowledge of DSS, articulates the research needs to yield mechanistic insights into a significant pathologic process that is poorly understood, and proposes several strategies aimed at elucidating the potential mechanobiological synergies responsible for DSS pathogenesis. The proposed roadmap has the potential to improve DSS management by identifying early targets for prevention of the fibrotic lesion, and may also prove beneficial in other fibrotic cardiovascular diseases associated with altered flow.

9.
J Vasc Access ; 19(5): 446-454, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30192183

ABSTRACT

PURPOSE: Perturbed vascular access hemodynamics is considered a potential driver of intimal hyperplasia, the leading cause of vascular access failure. To improve vascular access patency, a modular anastomotic valve device has been designed to normalize venous flow between hemodialysis periods while providing normal vascular access during hemodialysis. The objective of this study was to quantify the effects of arteriovenous graft flow rate on modular anastomotic valve device vascular access hemodynamics under realistic hemodialysis conditions. METHODS: Modular anastomotic valve device inlet and outlet flow conditions and velocity profiles were measured by ultrasound Doppler in a vascular access flow loop replicating arteriovenous graft flow rates of 800, 1000, and 1500 mL/min. Fluid-structure interaction simulations were performed to identify low wall shear stress regions on the vein wall and to characterize them in terms of temporal shear magnitude, oscillatory shear index, and relative residence time. The model was validated with respect to the Doppler measurements. RESULTS: The low wall shear stress region generated downstream of the anastomosis under low and moderate arteriovenous graft flow rates was eliminated under the highest arteriovenous graft flow rate. Increase in arteriovenous graft flow rate from 800 to 1500 mL/min resulted in a substantial increase in wall shear stress magnitude (27-fold increase in temporal shear magnitude), the elimination of wall shear stress bidirectionality (0.20-point reduction in oscillatory shear index), and a reduction in flow stagnation (98% decrease in relative residence time). While the results suggest the ability of high arteriovenous graft flow rates to protect the venous wall from intimal hyperplasia-prone hemodynamics, they indicate their adverse impact on the degree of venous hemodynamic abnormality.


Subject(s)
Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Hemodynamics , Renal Dialysis , Arteriovenous Shunt, Surgical/adverse effects , Blood Flow Velocity , Blood Vessel Prosthesis Implantation/adverse effects , Computer Simulation , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/pathology , Graft Occlusion, Vascular/physiopathology , Humans , Hyperplasia , Models, Anatomic , Models, Cardiovascular , Neointima , Prosthesis Design , Stress, Mechanical , Ultrasonography, Doppler, Pulsed , Vascular Patency
10.
Front Physiol ; 9: 993, 2018.
Article in English | MEDLINE | ID: mdl-30154723

ABSTRACT

The bicuspid aortic valve (BAV) generates wall shear stress (WSS) abnormalities in the ascending aorta (AA) that may be responsible for the high prevalence of aortopathy in BAV patients. While previous studies have analyzed the magnitude and oscillatory characteristics of the total or streamwise WSS in BAV AAs, the assessment of the circumferential component is lacking despite its expected significance in this highly helical flow environment. This gap may have hampered the identification of a robust hemodynamic predictor of BAV aortopathy. The objective of this study was to perform a global and component-specific assessment of WSS magnitude, oscillatory and directional characteristics in BAV AAs. The WSS environments were computed in the proximal and middle convexity of tricuspid aortic valve (TAV) and BAV AAs using our previous valve-aorta fluid-structure interaction (FSI) models. Component-specific WSS characteristics were investigated in terms of temporal shear magnitude (TSM) and oscillatory shear index (OSI). WSS directionality was quantified in terms of mean WSS vector magnitude and angle, and angular dispersion index (Dα). Local WSS magnitude and multidirectionality were captured in a new shear magnitude and directionality index (SMDI) calculated as the product of the mean WSS magnitude and Dα. BAVs subjected the AA to circumferential TSM overloads (2.4-fold increase vs. TAV). TAV and BAV AAs exhibited a unidirectional circumferential WSS (OSI < 0.04) and an increasingly unidirectional longitudinal WSS between the proximal (OSI > 0.21) and middle (OSI < 0.07) sections. BAVs generated mean WSS vectors skewed toward the anterior wall and WSS angular distributions exhibiting decreased uniformity in the proximal AA (0.27-point increase in Dα vs. TAV). SMDI was elevated in all BAV AAs but peaked in the proximal LR-BAV AA (3.6-fold increase vs. TAV) and in the middle RN-BAV AA (1.6-fold increase vs. TAV). This analysis demonstrates the significance of the circumferential WSS component and the existence of substantial WSS directional abnormalities in BAV AAs. SMDI abnormality distributions in BAV AAs follow the morphotype-dependent occurrence of dilation in BAV AAs, suggesting the predictive potential of this metric for BAV aortopathy.

11.
Front Physiol ; 8: 44, 2017.
Article in English | MEDLINE | ID: mdl-28203207

ABSTRACT

The bicuspid aortic valve (BAV) is a major risk factor for secondary aortopathy such as aortic dilation. The heterogeneous BAV morphotypes [left-right-coronary cusp fusion (LR), right-non-coronary cusp fusion (RN), and left-non-coronary cusp fusion (LN)] are associated with different dilation patterns, suggesting a role for hemodynamics in BAV aortopathogenesis. However, assessment of this theory is still hampered by the limited knowledge of the hemodynamic abnormalities generated by the distinct BAV morphotypes. The objective of this study was to compare experimentally the hemodynamics of a normal (i.e., non-dilated) ascending aorta (AA) subjected to tricuspid aortic valve (TAV), LR-BAV, RN-BAV, and NL-BAV flow. Tissue BAVs reconstructed from porcine TAVs were subjected to physiologic pulsatile flow conditions in a left-heart simulator featuring a realistic aortic root and compliant aorta. Phase-locked particle image velocimetry experiments were carried out to characterize the flow in the aortic root and in the tubular AA in terms of jet skewness and displacement, as well as mean velocity, viscous shear stress and Reynolds shear stress fields. While all three BAVs generated skewed and asymmetrical orifice jets (up to 1.7- and 4.0-fold increase in flow angle and displacement, respectively, relative to the TAV at the sinotubular junction), the RN-BAV jet was out of the plane of observation. The LR- and NL-BAV exhibited a 71% increase in peak-systolic orifice jet velocity relative to the TAV, suggesting an inherent degree of stenosis in BAVs. While these two BAV morphotypes subjected the convexity of the aortic wall to viscous shear stress overloads (1.7-fold increase in maximum peak-systolic viscous shear stress relative to the TAV-AA), the affected sites were morphotype-dependent (LR-BAV: proximal AA, NL-BAV: distal AA). Lastly, the LR- and NL-BAV generated high degrees of turbulence in the AA (up to 2.3-fold increase in peak-systolic Reynolds shear stress relative to the TAV) that were sustained from peak systole throughout the deceleration phase. This in vitro study reveals substantial flow abnormalities (increased jet skewness, asymmetry, jet velocity, turbulence, and shear stress overloads) in non-dilated BAV aortas, which differ from those observed in dilated aortas but still coincide with aortic wall regions prone to dilation.

12.
J Biomech ; 50: 63-70, 2017 01 04.
Article in English | MEDLINE | ID: mdl-27855987

ABSTRACT

Bicuspid aortic valves (BAVs) generate flow abnormalities that may promote aortopathy. While positive helix fraction (PHF) index, flow angle (θ), flow displacement (d) and wall shear stress (WSS) exhibit abnormalities in dilated BAV aortas, it is unclear whether those anomalies stem from the abnormal valve anatomy or the dilated aorta. Therefore, the objective of this study was to quantify the early impact of different BAV morphotypes on aorta hemodynamics prior to dilation. Fluid-structure interaction models were designed to quantify standard peak-systolic flow metrics and temporal WSS characteristics in a realistic non-dilated aorta connected to functional tricuspid aortic valve (TAV) and type-I BAVs. While BAVs generated increased helicity (PHF>0.68) in the middle ascending aorta (AA), larger systolic flow skewness (θ>11.2°) and displacement (d>6.8mm) relative to the TAV (PHF=0.51; θ<5.5°; d<3.3mm), no distinct pattern was observed between morphotypes. In contrast, WSS magnitude and directionality abnormalities were BAV morphotype- and site-dependent. Type-I BAVs subjected the AA convexity to peak-systolic WSS overloads (up to 1014% difference vs. TAV). While all BAVs increased WSS unidirectionality on the proximal AA relative to the TAV, the most significant abnormality was achieved by the BAV with left-right-coronary cusp fusion on the wall convexity (up to 0.26 decrease in oscillatory shear index vs. TAV). The results indicate the existence of strong hemodynamic abnormalities in non-dilated type-I BAV AAs, their colocalization with sites vulnerable to dilation and the superior specificity of WSS metrics over global hemodynamic metrics to the valve anatomy.


Subject(s)
Aorta/physiology , Aortic Valve/abnormalities , Models, Cardiovascular , Aortic Diseases/physiopathology , Aortic Valve/anatomy & histology , Aortic Valve/physiology , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Hemodynamics , Humans , Stress, Mechanical , Tricuspid Valve/physiology
14.
World J Cardiol ; 8(1): 89-97, 2016 Jan 26.
Article in English | MEDLINE | ID: mdl-26839660

ABSTRACT

AIM: To investigate the role of type-I left-right bicuspid aortic valve (LR-BAV) hemodynamic stresses in the remodeling of the thoracic ascending aorta (AA) concavity, in the absence of underlying genetic or structural defects. METHODS: Transient wall shear stress (WSS) profiles in the concavity of tricuspid aortic valve (TAV) and LR-BAV AAs were obtained computationally. Tissue specimens excised from the concavity of normal (non-dilated) porcine AAs were subjected for 48 h to those stress environments using a shear stress bioreactor. Tissue remodeling was characterized in terms of matrix metalloproteinase (MMP) expression and activity via immunostaining and gelatin zymography. RESULTS: Immunostaining semi-quantification results indicated no significant difference in MMP-2 and MMP-9 expression between the tissue groups exposed to TAV and LR-BAV AA WSS (P = 0.80 and P = 0.19, respectively). Zymography densitometry revealed no difference in MMP-2 activity (total activity, active form and latent form) between the groups subjected to TAV AA and LR-BAV AA WSS (P = 0.08, P = 0.15 and P = 0.59, respectively). CONCLUSION: The hemodynamic stress environment present in the concavity of type-I LR-BAV AA does not cause any significant change in proteolytic enzyme expression and activity as compared to that present in the TAV AA.

15.
World J Cardiol ; 7(6): 331-43, 2015 Jun 26.
Article in English | MEDLINE | ID: mdl-26131338

ABSTRACT

AIM: To explore ex vivo the role of bone morphogenetic protein-4 (BMP-4) and transforming growth factor-beta1 (TGF-ß1) in acute valvular response to fluid shear stress (FSS) abnormalities. METHODS: Porcine valve leaflets were subjected ex vivo to physiologic FSS, supra-physiologic FSS magnitude at normal frequency and supra-physiologic FSS frequency at normal magnitude for 48 h in a double-sided cone-and-plate bioreactor filled with standard culture medium. The role of BMP-4 and TGF-ß1 in the valvular response was investigated by promoting or inhibiting the downstream action of those cytokines via culture medium supplementation with BMP-4 or the BMP antagonist noggin, and TGF-ß1 or the TGF-ß1 inhibitor SB-431542, respectively. Fresh porcine leaflets were used as controls. Each experimental group consisted of six leaflet samples. Immunostaining and immunoblotting were performed to assess endothelial activation in terms of intercellular adhesion molecule-1 and vascular cell adhesion molecule-1 expressions, paracrine signaling in terms of BMP-4 and TGF-ß1 expressions and extracellular matrix (ECM) remodeling in terms of cathepsin L, cathepsin S, metalloproteinases (MMP)-2 and MMP-9 expressions. Immunostained images were quantified by normalizing the intensities of positively stained regions by the number of cells in each image while immunoblots were quantified by densitometry. RESULTS: Regardless of the culture medium, physiologic FSS maintained valvular homeostasis. Tissue exposure to supra-physiologic FSS magnitude in standard medium stimulated paracrine signaling (TGF-ß1: 467% ± 22% vs 100% ± 6% in fresh controls, BMP-4: 258% ± 22% vs 100% ± 4% in fresh controls; P < 0.05) and ECM degradation (MMP-2: 941% ± 90% vs 100% ± 19% in fresh controls, MMP-9: 1219% ± 190% vs 100% ± 16% in fresh controls, cathepsin L: 1187% ± 175% vs 100% ± 12% in fresh controls, cathepsin S: 603% ± 88% vs 100% ± 13% in fresh controls; P < 0.05), while BMP-4 supplementation also promoted fibrosa activation and TGF-ß1 inhibition reduced MMP-9 expression to the native tissue level (MMP-9: 308% ± 153% with TGF-ß1 inhibition vs 100% ± 16% in fresh control; P > 0.05). Supra-physiologic FSS frequency had no effect on endothelial activation and paracrine signaling regardless of the culture medium but TGF-ß1 silencing attenuated FSS-induced ECM degradation via MMP-9 downregulation (MMP-9: 302% ± 182% vs 100% ± 42% in fresh controls; P > 0.05). CONCLUSION: Valvular tissue is sensitive to FSS abnormalities. The TGF-ß1 inhibitor SB-431542 is a potential candidate molecule for attenuating the effects of FSS abnormalities on valvular remodeling.

16.
J Heart Valve Dis ; 24(1): 115-25, 2015 Jan.
Article in English | MEDLINE | ID: mdl-26182629

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: Calcific aortic valve disease (CAVD) is the most common valvular disorder. While fluid stresses are presumed to play a role in disease progression, the valvular hemodynamic changes experienced over the course of CAVD remain largely unknown. The study aim was to develop a laboratory protocol for the fabrication of tissue valve models mimicking mild and moderate calcific stenosis, for future use in flow studies. METHODS: Different hydroxyapatite (HA)-agarose mixtures were injected into porcine valve leaflets. Micro-computed tomography (micro-CT) was used to quantify HA deposition volume, area fraction and regional distribution, while von Kossa staining was performed to assess tissue mineralization. Particle image velocimetry measurements were carried out in intact and injected valves subjected to in vivo-like hemodynamics to characterize the degree of valvular stenosis in terms of geometric orifice area (GOA) and peak systolic velocity. RESULTS: The 5% HA-1% agarose solution (solution 1) and the 5% HA-0.5% agarose solution (solution 2) maximized the HA deposition volume. Leaflet injections with solution 1 resulted in a significant 1.9-fold increase in HA area fraction relative to solution 2 injections. While solution 1 injections generated multiple sites of high HA concentration, solution 2 injections produced smaller, discrete spots. Injections of both solution 1 and solution 2 into whole valves generated significant 47% and 32% reductions, respectively, in GOA and 1.8-fold and 1.5-fold increases, respectively, in peak systolic velocity, relative to untreated valves. CONCLUSION: Tissue valve models were generated that recapitulated the structure and hemodynamics of mild and moderate valvular calcification. Those models may be used for future investigations of the native valvular hemodynamic alterations that occur during CAVD.


Subject(s)
Aortic Valve Stenosis/physiopathology , Aortic Valve/pathology , Aortic Valve/physiopathology , Calcinosis/physiopathology , Hemodynamics , Animals , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/chemically induced , Aortic Valve Stenosis/diagnostic imaging , Blood Flow Velocity , Calcinosis/chemically induced , Calcinosis/diagnostic imaging , Disease Models, Animal , Durapatite , Regional Blood Flow , Sepharose , Severity of Illness Index , Swine , X-Ray Microtomography
17.
World J Cardiol ; 6(12): 1227-33, 2014 Dec 26.
Article in English | MEDLINE | ID: mdl-25548612

ABSTRACT

The bicuspid aortic valve (BAV) is the most common form of inheritable cardiac defect. Although this abnormality may still achieve normal valvular function, it is often associated with secondary valvular and aortic complications such as calcific aortic valve disease and aortic dilation. The clinical significance and economic burden of BAV disease justify the need for improved clinical guidelines and more robust therapeutic modalities, which address the root-cause of those pathologies. Unfortunately, the etiology of BAV valvulopathy and aortopathy is still a debated issue. While the BAV anatomy and its secondary complications have been linked historically to a common genetic root, recent advances in medical imaging have demonstrated the existence of altered hemodynamics near BAV leaflets prone to calcification and BAV aortic regions vulnerable to dilation. The abnormal mechanical stresses imposed by the BAV on its leaflets and on the aortic wall could be transduced into cell-mediated processes, leading ultimately to valvular calcification and aortic medial degeneration. Despite increasing evidence for this hemodynamic etiology, the demonstration of the involvement of mechanical abnormalities in the pathogenesis of BAV disease requires the investigation of causality between the blood flow environment imposed on the leaflets and the aortic wall and the local biology, which has been lacking to date. This editorial discusses the different hypothetical etiologies of BAV disease with a particular focus on the most recent advances in cardiovascular imaging, flow characterization techniques and tissue culture methodologies that have provided new evidence in support of the hemodynamic theory.

19.
J Vasc Access ; 15(6): 448-60, 2014.
Article in English | MEDLINE | ID: mdl-25198822

ABSTRACT

PURPOSE: Arteriovenous graft patency is limited by terminal occlusion caused by intimal hyperplasia (IH). Motivated by evidence that flow disturbances promote IH progression, a modular anastomotic valve device (MAVD) was designed to isolate the graft from the circulation between dialysis periods (closed position) and enable vascular access during dialysis (open position). The objective of this study was to perform a preliminary computational assessment of the device ability to normalize venous flow between dialysis periods and potentially limit IH development and thrombogenesis. METHODS: Computational fluid dynamics simulations were performed to compare flow and wall shear stress (WSS) in a native vein and MAVD prototypes featuring anastomotic angles of 90° and 30°. Low WSS (LWSS) regions prone to IH development were characterized in terms of temporal shear magnitude (TSM), oscillatory shear index (OSI), and relative residence time (RRT). Thrombogenic potential was assessed by investigating the loading history of fluid particles traveling through the device. RESULTS: The closed MAVD exhibited the same flow characteristics as the native vein (0.3% difference in pressure drop, 3.5% difference in surface-averaged WSS). The open MAVD generated five LWSS regions (TSM <0.5 Pa) exhibiting different degrees of flow reversal (surface-averaged OSI: 0.03-0.36) and stagnation (max RRT: 2.50-37.16). Reduction in anastomotic angle resulted in the suppression of three LWSS regions and overall reductions in flow reversal (surface-averaged OSI <0.21) and stagnation (max RRT <18.05). CONCLUSIONS: This study suggests the ability of the MAVD to normalize venous flow between dialysis periods while generating the typical hemodynamics of end-to-side vein-graft anastomoses during dialysis.


Subject(s)
Arteriovenous Shunt, Surgical/instrumentation , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Computer Simulation , Graft Occlusion, Vascular/prevention & control , Hemodynamics , Models, Cardiovascular , Renal Dialysis , Thrombosis/prevention & control , Upper Extremity/blood supply , Arteriovenous Shunt, Surgical/adverse effects , Blood Flow Velocity , Blood Vessel Prosthesis Implantation/adverse effects , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Humans , Materials Testing , Prosthesis Design , Regional Blood Flow , Risk Factors , Stress, Mechanical , Thrombosis/etiology , Thrombosis/physiopathology , Vascular Patency
20.
Biomech Model Mechanobiol ; 13(6): 1209-25, 2014 Nov.
Article in English | MEDLINE | ID: mdl-24599392

ABSTRACT

The type-I bicuspid aortic valve (BAV), which differs from the normal tricuspid aortic valve (TAV) most commonly by left-right coronary cusp fusion, is frequently associated with secondary aortopathies. While BAV aortic dilation has been linked to a genetic predisposition, hemodynamics has emerged as a potential alternate etiology. However, the link between BAV hemodynamics and aortic medial degeneration has not been established. The objective of this study was to compare the regional wall shear stresses (WSS) in a TAV and BAV ascending aorta (AA) and to isolate ex vivo their respective impact on aortic wall remodeling. The WSS environments generated in the convex region of a TAV and BAV AA were predicted through fluid-structure interaction (FSI) simulations in an aorta model subjected to both valvular flows. Remodeling of porcine aortic tissue exposed to TAV and BAV AA WSS for 48 h in a cone-and-plate bioreactor was investigated via immunostaining, immunoblotting and zymography. FSI simulations revealed the existence of larger and more unidirectional WSS in the BAV than in the TAV AA convexity. Exposure of normal aortic tissue to BAV AA WSS resulted in increased MMP-2 and MMP-9 expressions and MMP-2 activity but similar fibrillin-1 content and microfibril organization relative to the TAV AA WSS treatment. This study confirms the sensitivity of aortic tissue to WSS abnormalities and demonstrates the susceptibility of BAV hemodynamic stresses to focally mediate aortic medial degradation. The results provide compelling support to the important role of hemodynamics in BAV secondary aortopathy.


Subject(s)
Aorta/physiology , Aortic Valve/abnormalities , Hemodynamics/physiology , Sus scrofa/physiology , Vascular Remodeling/physiology , Animals , Aorta/enzymology , Aortic Valve/physiology , Bicuspid Aortic Valve Disease , Biomarkers/metabolism , Bioreactors , Cell Survival , Heart Valve Diseases , Humans , Imaging, Three-Dimensional , Matrix Metalloproteinase 2/metabolism , Matrix Metalloproteinase 9/metabolism , Reproducibility of Results , Shear Strength , Stress, Mechanical , Time Factors , Tissue Culture Techniques , Up-Regulation
SELECTION OF CITATIONS
SEARCH DETAIL