1.
Magn Reson Med ; 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38888135

ABSTRACT

PURPOSE: To develop and demonstrate a fast 3D fMRI acquisition technique with high spatial resolution over a reduced FOV, named k-t 3D reduced FOV imaging (3D-rFOVI). METHODS: Based on 3D gradient-echo EPI, k-t 3D-rFOVI used a 2D RF pulse to reduce the FOV in the in-plane phase-encoding direction, boosting spatial resolution without increasing echo train length. For image acceleration, full sampling was applied in the central k-space region along the through-slab direction (kz) for all time frames, while randomized undersampling was used in outer kz regions at different time frames. Images were acquired at 3T and reconstructed using a method based on partial separability. fMRI detection sensitivity of k-t 3D-rFOVI was quantitively analyzed with simulation data. Human visual fMRI experiments were performed to evaluate k-t 3D-rFOVI and compare it with a commercial multiband EPI sequence. RESULTS: The simulation data showed that k-t 3D-rFOVI can detect 100% of fMRI activations with an acceleration factor (R) of 2 and ˜80% with R = 6. In the human fMRI data acquired with 1.5-mm spatial resolution and 800-ms volume TR (TRvol), k-t 3D-rFOVI with R = 4 detected 46% more activated voxels in the visual cortex than the multiband EPI. Additional fMRI experiments showed that k-t 3D-rFOVI can achieve TRvol of 480 ms with R = 6, while reliably detecting visual activation. CONCLUSIONS: k-t 3D-rFOVI can simultaneously achieve a high spatial resolution (1.5-mm isotropically) and short TRvol (480-ms) at 3T. It offers a robust acquisition technique for fast fMRI studies over a focused brain volume.

2.
Magn Reson Med ; 90(6): 2375-2387, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37667533

ABSTRACT

PURPOSE: EPI with blip-up/down acquisition (BUDA) can provide high-quality images with minimal distortions by using two readout trains with opposing phase-encoding gradients. Because of the need for two separate acquisitions, BUDA doubles the scan time and degrades the temporal resolution when compared to single-shot EPI, presenting a major challenge for many applications, particularly fMRI. This study aims at overcoming this challenge by developing an echo-shifted EPI BUDA (esEPI-BUDA) technique to acquire both blip-up and blip-down datasets in a single shot. METHODS: A 3D esEPI-BUDA pulse sequence was designed by using an echo-shifting strategy to produce two EPI readout trains. These readout trains produced a pair of k-space datasets whose k-space trajectories were interleaved with opposite phase-encoding gradient directions. The two k-space datasets were separately reconstructed using a 3D SENSE algorithm, from which time-resolved B0 -field maps were derived using TOPUP in FSL and then input into a forward model of joint parallel imaging reconstruction to correct for geometric distortion. In addition, Hankel structured low-rank constraint was incorporated into the reconstruction framework to improve image quality by mitigating the phase errors between the two interleaved k-space datasets. RESULTS: The 3D esEPI-BUDA technique was demonstrated in a phantom and an fMRI study on healthy human subjects. Geometric distortions were effectively corrected in both phantom and human brain images. In the fMRI study, the visual activation volumes and their BOLD responses were comparable to those from conventional 3D echo-planar images. CONCLUSION: The improved imaging efficiency and dynamic distortion correction capability afforded by 3D esEPI-BUDA are expected to benefit many EPI applications.


Subject(s)
Algorithms , Arthroplasty, Replacement , Humans , Brain/diagnostic imaging , Healthy Volunteers , Phantoms, Imaging
3.
Bioengineering (Basel) ; 10(7)2023 Jul 21.
Article in English | MEDLINE | ID: mdl-37508891

ABSTRACT

PURPOSE: To develop a novel convolutional recurrent neural network (CRNN-DWI) and apply it to reconstruct a highly undersampled (up to six-fold) multi-b-value, multi-direction diffusion-weighted imaging (DWI) dataset. METHODS: A deep neural network that combines a convolutional neural network (CNN) and recurrent neural network (RNN) was first developed by using a set of diffusion images as input. The network was then used to reconstruct a DWI dataset consisting of 14 b-values, each with three diffusion directions. For comparison, the dataset was also reconstructed with zero-padding and 3D-CNN. The experiments were performed with undersampling rates (R) of 4 and 6. Standard image quality metrics (SSIM and PSNR) were employed to provide quantitative assessments of the reconstructed image quality. Additionally, an advanced non-Gaussian diffusion model was employed to fit the reconstructed images from the different approaches, thereby generating a set of diffusion parameter maps. These diffusion parameter maps from the different approaches were then compared using SSIM as a metric. RESULTS: Both the reconstructed diffusion images and diffusion parameter maps from CRNN-DWI were better than those from zero-padding or 3D-CNN. Specifically, the average SSIM and PSNR of CRNN-DWI were 0.750 ± 0.016 and 28.32 ± 0.69 (R = 4), and 0.675 ± 0.023 and 24.16 ± 0.77 (R = 6), respectively, both of which were substantially higher than those of zero-padding or 3D-CNN reconstructions. The diffusion parameter maps from CRNN-DWI also yielded higher SSIM values for R = 4 (>0.8) and for R = 6 (>0.7) than the other two approaches (for R = 4, <0.7, and for R = 6, <0.65). CONCLUSIONS: CRNN-DWI is a viable approach for reconstructing highly undersampled DWI data, providing opportunities to reduce the data acquisition burden.

4.
Magn Reson Med ; 90(3): 910-921, 2023 09.
Article in English | MEDLINE | ID: mdl-37103885

ABSTRACT

PURPOSE: To develop a time-efficient pulse sequence that acquires multiple diffusion-weighted images with distinct diffusion times in a single shot by using multiple stimulated echoes (mSTE) with variable flip angles (VFA). METHODS: The proposed diffusion-weighted mSTE with VFA (DW-mSTE-VFA) sequence begins with two 90° RF pulses that straddle a diffusion gradient lobe (GD ) to excite and restore one half of the magnetization into the longitudinal axis. The restored longitudinal magnetization was successively re-excited by a series of RF pulses with VFA, each followed by another GD , to generate a set of stimulated echoes. Each of the multiple stimulated echoes was acquired with an EPI echo train. As such, the train of multiple stimulated echoes produced a set of diffusion-weighted images with varying diffusion times in a single shot. This technique was experimentally demonstrated on a diffusion phantom, a fruit, and healthy human brain and prostate at 3 T. RESULTS: In the phantom experiment, the mean ADC measured at different diffusion times using DW-mSTE-VFA were highly consistent (r = 0.999) with those from a commercial spin-echo diffusion-weighted EPI sequence. In the fruit and brain experiments, DW-mSTE-VFA exhibited similar diffusion-time dependence to a standard diffusion-weighted stimulated echo sequence. The ADC showed significant time dependence in the human brain (p = 0.003 in both white matter and gray matter) and prostate tissues (p = 0.003 in both peripheral zone and central gland). CONCLUSION: DW-mSTE-VFA offers a time-efficient tool for investigating the diffusion-time dependency in diffusion MRI studies.


Subject(s)
Diffusion Magnetic Resonance Imaging , Prostate , Male , Humans , Diffusion Magnetic Resonance Imaging/methods , Prostate/diagnostic imaging , Brain/diagnostic imaging , Head , Gray Matter , Echo-Planar Imaging
5.
Magn Reson Med ; 90(1): 250-258, 2023 07.
Article in English | MEDLINE | ID: mdl-36932652

ABSTRACT

PURPOSE: To develop a DWI sequence with multiple readout echo-trains in a single shot (multi-readout DWI) over a reduced FOV, and to demonstrate its ability to achieve high data acquisition efficiency in the study of coupling between diffusion and relaxation in the human prostate. METHODS: The proposed multi-readout DWI sequence plays out multiple EPI readout echo-trains after a Stejskal-Tanner diffusion preparation module. Each EPI readout echo-train corresponded to a distinct effective TE. To maintain a high spatial resolution with a relatively short echo-train for each readout, a 2D RF pulse was used to limit the FOV. Experiments were performed on the prostate of six healthy subjects to acquire a set of images with three b values (0, 500, and 1000 s/mm2 ) and three TEs (63.0, 78.8, and 94.6 ms), producing three ADC maps at different TEs and three T 2 * $$ {T}_2^{\ast } $$ maps at different b values. RESULTS: Multi-readout DWI enabled a threefold acceleration without compromising the spatial resolution when compared with a conventional single-readout sequence. Images with three b values and three TEs were obtained in 3 min 40 s with an adequate SNR (≥ 26.9). The ADC values (1.45 ± 0.13, 1.52 ± 0.14, and 1.58 ± 0.15  µm 2 / ms $$ {\upmu \mathrm{m}}^2/\mathrm{ms} $$ ; P < 0.01) exhibited an increasing trend as TEs increased (63.0 ms, 78.8 ms, and 94.6 ms), whereas T 2 * $$ {T}_2^{\ast } $$ values (74.78 ± 13.21, 63.21 ± 7.84, and 56.61 ± 5.05 ms; P < 0.01) decreases as the b values increased (0, 500, and 1000 s/mm2 ). CONCLUSION: The multi-readout DWI sequence over a reduced FOV provides a time-efficient technique to study the coupling between diffusion and relaxation times.


Subject(s)
Diffusion Magnetic Resonance Imaging , Prostate , Male , Humans , Prostate/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods
6.
Phys Med Biol ; 68(4)2023 02 03.
Article in English | MEDLINE | ID: mdl-36634366

ABSTRACT

Objective.This study aimed at developing a simultaneous multi-segment (SMSeg) imaging technique using a two-dimensional (2D) RF pulse in conjunction with echo planar imaging (EPI) to image multiple focal regions.Approach.The SMSeg technique leveraged periodic replicates of the excitation profile of a 2D RF pulse to simultaneously excite multiple focal regions at different locations. These locations were controlled by rotating and scaling transmit k-space trajectories. The resulting multiple isolated focal regions were projected into a composite 'slice' for display. GRAPPA-based parallel imaging was incorporated into SMSeg by taking advantage of coil sensitivity variations in both the phase-encoded and slice-selection directions. The SMSeg technique was implemented at 3 T in a single-shot gradient-echo EPI sequence and demonstrated in a phantom and human brains for both anatomic imaging and functional imaging.Main results.In both the phantom and the human brain, SMSeg images from three focal regions were simultaneously acquired. SMSeg imaging enabled up to a six-fold acceleration in parallel imaging without causing appreciable residual aliasing artifacts when compared with a conventional gradient-echo EPI sequence with the same acceleration factor. In the functional imaging experiment, BOLD activations associated with a visuomotor task were simultaneously detected in two non-coplanar segments (each with a size of 240 × 30 mm2), corresponding to visual and motor cortices, respectively.Significance.Our study has demonstrated that SMSeg imaging can be a viable method for studying multiple focal regions simultaneously.


Subject(s)
Echo-Planar Imaging , Image Enhancement , Humans , Echo-Planar Imaging/methods , Image Enhancement/methods , Brain/diagnostic imaging , Brain Mapping/methods , Phantoms, Imaging , Artifacts , Image Processing, Computer-Assisted/methods
7.
Magn Reson Med ; 88(4): 1690-1701, 2022 10.
Article in English | MEDLINE | ID: mdl-35666824

ABSTRACT

PURPOSE: The gradient-echo-train-based Sub-millisecond Periodic Event Encoded Dynamic Imaging (get-SPEEDI) technique provides ultrahigh temporal resolutions (∼0.6 ms) for detecting rapid physiological activities, but its practical adoption can be hampered by long scan times. This study aimed at developing a more efficient variant of get-SPEEDI for reducing the scan time without degrading temporal resolution or image quality. METHODS: The proposed pulse sequence, named k-t get-SPEEDI, accelerated get-SPEEDI acquisition by undersampling the k-space phase-encoding lines semi-randomly. At each time frame, k-space was fully sampled in the central region whereas randomly undersampled in the outer regions. A time-series of images was reconstructed using an algorithm based on the joint partial separability and sparsity constraints. To demonstrate the performance of k-t get-SPEEDI, images of human aortic valve opening and closing were acquired with 0.6-ms temporal resolution and compared with those from conventional get-SPEEDI. RESULTS: k-t get-SPEEDI achieved a 2-fold scan time reduction over the conventional get-SPEEDI (from ∼6 to ∼3 min), while achieving comparable SNRs and contrast-to-noise ratio (CNRs) for visualizing the dynamic process of aortic valve: SNR/CNR ≈$$ \approx $$ 70/38 vs. 73/39 in the k-t and conventional get-SPEEDI scans, respectively. The time courses of aortic valve area also matched well between these two sequences with a correlation coefficient of 0.86. CONCLUSIONS: The k-t get-SPEEDI pulse sequence was able to half the scan time without compromising the image quality and ultrahigh temporal resolution. Additional scan time reduction may also be possible, facilitating in vivo adoptions of SPEEDI techniques.


Subject(s)
Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging , Algorithms , Humans , Image Interpretation, Computer-Assisted/methods , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods
8.
Magn Reson Med ; 88(3): 1303-1313, 2022 09.
Article in English | MEDLINE | ID: mdl-35657055

ABSTRACT

PURPOSE: To develop a 2D multi-echo passband balanced SSFP (bSSFP) sequence using an echo-train readout with a sequential phase-encoding order (sequential multi-echo bSSFP), and evaluate its performance in fast functional brain imaging at 7 T. METHODS: As images of sequential multi-echo bSSFP exhibit multiple ghosts due to periodic k-space modulations, a GRAPPA-based reconstruction method was proposed to eliminate ghosting artifacts. MRI experiments were performed to compare the image quality of multi-echo bSSFP and conventional single-echo bSSFP. Submillimeter-resolution fMRI using a checkerboard visual stimulus was conducted to compare the activation characteristics of multi-echo bSSFP, conventional single-echo bSSFP and standard gradient-echo EPI (GE-EPI). RESULTS: A higher mean structural similarity index was found between images of single-echo bSSFP and multi-echo bSSFP with a shorter echo train length (ETL). Multi-echo bSSFP (ETL = 3) showed higher temporal SNR (tSNR) values than GRAPPA-accelerated single-echo bSSFP (R = 2). In submillimeter-resolution fMRI experiments, multi-echo bSSFP (ETL = 3) approached the imaging speed of GRAPPA-accelerated single-echo bSSFP (R = 2), but without tSNR penalty and reduced activation due to acceleration. The median t-value and the number of significantly activated voxels were comparable between GE-EPI and multi-echo bSSFP (ETL = 3) that provides virtually distortion-free functional images and inherits the activation patterns of conventional bSSFP. CONCLUSION: Sequential multi-echo bSSFP (ETL = 3) is suitable for fast fMRI with submillimeter in-plane resolution, and offers an option to accelerate bSSFP imaging without tSNR penalty like parallel imaging.


Subject(s)
Echo-Planar Imaging , Magnetic Resonance Imaging , Artifacts , Brain/diagnostic imaging , Echo-Planar Imaging/methods , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods
9.
Magn Reson Med ; 87(1): 263-271, 2022 01.
Article in English | MEDLINE | ID: mdl-34350601

ABSTRACT

PURPOSE: To develop an in-plane simultaneous multisegment (IP-SMS) imaging technique using a 2D-RF pulse and to demonstrate its ability to achieve high spatial resolution in EPI while reducing image distortion. METHODS: The proposed IP-SMS technique takes advantage of periodic replicates of the excitation profile of a 2D-RF pulse to simultaneously excite multiple segments within a slice. These segments were acquired over a reduced FOV and separated using a joint GRAPPA reconstruction by leveraging virtual coils that combined the physical coil sensitivity and 2D-RF pulse spatial response. Two excitations were used with complementary spatial response profiles to adequately cover a full FOV, producing a full-FOV image that had the benefits of reduced FOV with high spatial resolution and reduced distortion. The IP-SMS technique was implemented in a diffusion-weighted single-shot EPI sequence. Experimental demonstrations were performed on a phantom and healthy human brain. RESULTS: In the phantom experiment, IP-SMS enabled a four-fold acceleration using an eight-channel coil without causing residual aliasing artifacts. In the human brain experiment, diffusion-weighted images with high in-plane resolution (1 × 1 mm2 ) and substantially reduced image distortion were obtained in all imaging planes in comparison with a commercial diffusion-weighted EPI sequence. The capability of IP-SMS for contiguous whole-brain coverage was also demonstrated. CONCLUSION: The proposed IP-SMS technique can realize the benefits of reduced-FOV imaging while achieving a full-FOV coverage with good image quality and time efficiency.


Subject(s)
Algorithms , Echo-Planar Imaging , Artifacts , Brain/diagnostic imaging , Diffusion Magnetic Resonance Imaging , Humans , Image Enhancement , Image Processing, Computer-Assisted , Phantoms, Imaging
10.
Magn Reson Med ; 87(5): 2372-2379, 2022 05.
Article in English | MEDLINE | ID: mdl-34894639

ABSTRACT

PURPOSE: This study aimed at developing a 3D reduced field-of-view imaging (3D-rFOVI) technique using a 2D radiofrequency (RF) pulse, and demonstrating its ability to achieve isotropic high spatial resolution and reduced image distortion in echo planar imaging (EPI). METHODS: The proposed 3D-rFOVI technique takes advantage of a 2D RF pulse to excite a slab along the conventional slice-selection direction (i.e., z-direction) while limiting the spatial extent along the phase-encoded direction (i.e., y-direction) within the slab. The slab is phase-encoded in both through-slab and in-slab phase-encoded directions. The 3D-rFOVI technique was implemented at 3T in gradient-echo and spin-echo EPI pulse sequences for functional MRI (fMRI) and diffusion-weighted imaging (DWI), respectively. 3D-rFOVI experiments were performed on a phantom and human brain to illustrate image distortion reduction, as well as isotropic high spatial resolution, in comparison with 3D full-FOV imaging. RESULTS: In both the phantom and the human brain, image voxel dislocation was substantially reduced by 3D-rFOVI when compared with full-FOV imaging. In the fMRI experiment with visual stimulation, 3D isotropic spatial resolution of (2 × 2 × 2 mm3 ) was achieved with an adequate signal-to-noise ratio (81.5) and blood oxygen level-dependent (BOLD) contrast (2.5%). In the DWI experiment, diffusion-weighted brain images with an isotropic resolution of (1 × 1 × 1 mm3 ) was obtained without appreciable image distortion. CONCLUSION: This study indicates that 3D-rFOVI is a viable approach to 3D neuroimaging over a zoomed region.


Subject(s)
Diffusion Magnetic Resonance Imaging , Echo-Planar Imaging , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods , Humans , Imaging, Three-Dimensional/methods , Phantoms, Imaging , Signal-To-Noise Ratio
11.
Mathematics (Basel) ; 9(14)2021 Jul 02.
Article in English | MEDLINE | ID: mdl-34386373

ABSTRACT

It has been increasingly reported that in biological tissues diffusion-weighted MRI signal attenuation deviates from mono-exponential decay, especially at high b-values. A number of diffusion models have been proposed to characterize this non-Gaussian diffusion behavior. One of these models is the continuous-time random-walk (CTRW) model, which introduces two new parameters: a fractional order time derivative α and a fractional order spatial derivative ß. These new parameters have been linked to intravoxel diffusion heterogeneities in time and space, respectively, and are believed to depend on diffusion times. Studies on this time dependency are limited, largely because the diffusion time cannot vary over a board range in a conventional spin-echo echo-planar imaging sequence due to the accompanying T2 decays. In this study, we investigated the time-dependency of the CTRW model in Sephadex gel phantoms across a broad diffusion time range by employing oscillating-gradient spin-echo, pulsed-gradient spin-echo, and pulsed-gradient stimulated echo sequences. We also performed Monte Carlo simulations to help understand our experimental results. It was observed that the diffusion process fell into the Gaussian regime at extremely short diffusion times whereas it exhibited a strong time dependency in the CTRW parameters at longer diffusion times.

12.
Magn Reson Med ; 86(6): 3166-3174, 2021 12.
Article in English | MEDLINE | ID: mdl-34270138

ABSTRACT

PURPOSE: To demonstrate an MRI pulse sequence-Sub-millisecond Periodic Event Encoded Dynamic Imaging with a reduced field of view (or rFOV-SPEEDI)-for decreasing the scan times while achieving sub-millisecond temporal resolution. METHODS: rFOV-SPEEDI was based on a variation of SPEEDI, known as get-SPEEDI, which used each echo in an echo-train to sample a distinct k-space raster by synchronizing with a cyclic event. This can produce a set of time-resolved images of the cyclic event with a temporal resolution determined by the echo spacing (typically < 1 ms). rFOV-SPEEDI incorporated a 2D radiofrequency (RF) pulse into get-SPEEDI to limit the field of view (FOV), leading to reduction in phase-encoding steps and subsequently decreased scan times without compromising the spatial resolution. Two experiments were performed at 3T to illustrate rFOV-SPEEDI's capability of capturing fast-changing electric currents in a phantom and the rapid opening and closing of aortic valve in human subjects over reduced FOVs. The results were compared with those from full FOV get-SPEEDI. RESULTS: In the first experiment, the rapidly varying currents (50-200 Hz) were successfully captured with a temporal resolution of 0.8 ms, and agreed well with the applied currents. In the second experiment, the rapid opening and closing processes of aortic valve were clearly visualized with a temporal resolution of 0.6 ms over a reduced FOV (12 × 12 cm2 ). In both experiments, the acquisition times of rFOV-SPEEDI were decreased by 33%-50% relative to full FOV get-SPEEDI acquisitions and the spatial resolution was maintained. CONCLUSION: Reducing the FOV is a viable approach to shortening the scan times in SPEEDI, which is expected to help stimulate SPEEDI applications for studying ultrafast, cyclic physiological and biophysical processes over a focal region.


Subject(s)
Aortic Valve , Magnetic Resonance Imaging , Aortic Valve/diagnostic imaging , Humans , Phantoms, Imaging , Radio Waves
13.
NMR Biomed ; 34(9): e4565, 2021 09.
Article in English | MEDLINE | ID: mdl-34061413

ABSTRACT

Few in vivo studies have focused on the perivenous association of tubers and iron deposition in the deep gray nuclei in patients with tuberous sclerosis complex (TSC). We investigated this possible relationship in TSC patients using susceptibility weighted imaging (SWI) at 7 T. SWI with high spatial resolution and enhanced sensitivity was performed on 11 TSC patients in comparison with 15 age- and sex-matched healthy controls. The relationship between tubers and veins was evaluated. In addition, the phase images of SWI were processed to produce local field shift (LFS) maps to quantify iron deposition. The mean LFS in the deep gray nuclei was compared between the TSC patients and healthy controls using a covariance analysis. Venous involvement was observed in 211 of the 231 (91.3%) cortical tubers on SWI. The slender tubers often oriented around the long axis of penetrating veins, possibly because cortical tubers typically developed and/or migrated along venous vasculatures. A significant difference in LFS of the thalamus was detected between the TSC patients and healthy controls (3.36 ± 0.50 versus 3.01 ± 0.39, p < 0.01). The new in vivo imaging features observed at 7 T provide valuable insights into the possible venous association of TSC lesions and iron accumulation in the deep gray nuclei. Our results may lead to a better understanding of the pathological changes involved in TSC under in vivo conditions.


Subject(s)
Magnetic Resonance Imaging , Tuberous Sclerosis/diagnostic imaging , Adolescent , Adult , Age Factors , Brain/diagnostic imaging , Brain/pathology , Case-Control Studies , Child , Diffusion Magnetic Resonance Imaging , Disease Susceptibility , Female , Humans , Male , Tuberous Sclerosis/pathology , Young Adult
14.
J Magn Reson Imaging ; 54(4): 1246-1254, 2021 10.
Article in English | MEDLINE | ID: mdl-33761166

ABSTRACT

BACKGROUND: Visualization of aortic valve dynamics is important in diagnosing valvular diseases but is challenging to perform with magnetic resonance imaging (MRI) due to the limited temporal resolution. PURPOSE: To develop an MRI technique with sub-millisecond temporal resolution and demonstrate its application in visualizing rapid aortic valve opening and closing in human subjects in comparison with echocardiography and conventional MRI techniques. STUDY TYPE: Prospective. POPULATION: Twelve healthy subjects. FIELD STRENGTH/SEQUENCE: 3 T; gradient-echo-train-based sub-millisecond periodic event encoded imaging (get-SPEEDI) and balanced steady-state free precession (bSSFP). ASSESSMENT: Images were acquired using get-SPEEDI with a temporal resolution of 0.6 msec. get-SPEEDI was triggered by an electrocardiogram so that each echo in the gradient echo train corresponded to an image at a specific time point, providing a time-resolved characterization of aortic valve dynamics. For comparison, bSSFP was also employed with 12 msec and 24 msec temporal resolutions, respectively. The durations of the aortic valve rapid opening (Tro ), rapid closing (Trc ), and the maximal aortic valve area (AVA) normalized to height were measured with all three temporal resolutions. M-mode echocardiograms with a temporal resolution of 0.8 msec were obtained for further comparison. STATISTICAL TEST: Parameters were compared between the three sequences, together with the echocardiography results, with a Mann-Whitney U test. RESULTS: Significantly shorter Tro (mean ± SD: 27.5 ± 6.7 msec) and Trc (43.8 ± 11.6 msec) and larger maximal AVA/height (2.01 ± 0.29 cm2 /m) were measured with get-SPEEDI compared to either bSSFP sequence (Tro of 56.3 ± 18.8 and 63.8 ± 20.2 msec; Trc of 68.2 ± 16.6 and 72.8 ± 18.2 msec; maximal AVA/height of 1.63 ± 0.28 and 1.65 ± 0.32 cm2 /m for 12 msec and 24 msec temporal resolutions, respectively, P < 0.05). In addition, the get-SPEEDI results were more consistent with those measured using echocardiography, especially for Tro (29.0 ± 4.1 msec, P = 0.79) and Trc (41.6 ± 4.3 msec, P = 0.16). DATA CONCLUSION: get-SPEEDI allows for visualization of human aortic valve dynamics and provided values closer to those measured using echocardiography than the bSSFP sequences. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Aortic Valve/diagnostic imaging , Echocardiography , Humans , Magnetic Resonance Imaging , Prospective Studies
15.
Comput Med Imaging Graph ; 89: 101830, 2021 04.
Article in English | MEDLINE | ID: mdl-33548821

ABSTRACT

PURPOSE: High field strength 3T and 7T Time-Of-Flight Magnetic Resonance Angiography (TOF- MRA) achieves better visualization of intracranial vessels, so it attracts much attention. However, quantitative comparison between 3T and 7T MRA is lacking in the aspects of image quality and the practical application of cerebrovascular diseases. METHODS: In this paper, a quantitative framework of 3T and 7T TOF-MRA comparison is proposed, which contains two steps including the automated cerebrovascular segmentation and statistical analysis. Firstly, the whole vascular structures on both 3T and 7T TOF-MRA images are segmented automatically, especially those small blood vessels in 7T MRA. The skeleton extraction-based automatic seed point detection is implemented to ensure the segmented vascular structure complete and precise. Secondly, the statistical analysis of the differences between 3T and 7T MRA is carried out in the aspects of image quality and the characteristics of some important vessels. The objects of statistical analysis are achieved and analyzed automatically without needing the time- consuming human beings' participation, therefore, it is efficient and objective. RESULTS: The comparison experiments on seven pairs of 3T and 7T TOF MRA images validated that about image quality, the contrast-to-noise ratio of 7T MRA was about 4.53 ± 0.95 times as much as that of 3T MRA. About the cerebrovascular information, small vessels were more abundant in 7T MRA compared with 3T MRA (branches number: 462.0 ± 58.5 vs 393.1 ± 63.3). CONCLUSIONS: The proposed framework can segment the whole cerebrovascular structure automatically and compare TOF-MRA with different field strengths objectively and quantitatively. It is helpful for clinical cerebrovascular disease, especially cerebral small vessel diseases.


Subject(s)
Magnetic Resonance Angiography , Humans
16.
Magn Reson Med ; 85(5): 2434-2444, 2021 05.
Article in English | MEDLINE | ID: mdl-33252784

ABSTRACT

PURPOSE: To demonstrate an MRI technique-Submillisecond Periodic Event Encoded Dynamic Imaging (SPEEDI)-for capturing cyclic dynamic events with submillisecond temporal resolution. METHODS: The SPEEDI technique is based on an FID or an echo signal in which each time point in the signal is used to sample a distinct k-space raster, followed by repeated FIDs or echoes to produce the remaining k-space data in each k-space raster. All acquisitions are synchronized with a cyclic event, resulting in a set of time-resolved images of the cyclic event with a temporal resolution determined by the dwell time. In SPEEDI, spatial encoding is accomplished by phase encoding. The SPEEDI technique was demonstrated in two experiments at 3 T to (1) visualize fast-changing electric currents that mimicked the waveform of an action potential, and (2) characterize rapidly decaying eddy currents in an MRI system, with a temporal resolution of 0.2 ms and 0.4 ms, respectively. In both experiments, compressed sensing was incorporated to reduce the scan times. Phase difference maps related to the dynamics of electric currents or eddy currents were then obtained. RESULTS: In the first experiment, time-resolved phase maps resulting from the action potential-mimicking current waveform were successfully obtained and agreed well with theoretical calculations (normalized RMS error = 0.07). In the second experiment, spatially resolved eddy current phase maps revealed time constants (27.1 ± 0.2 ms, 41.1 ± 3.5 ms, and 34.8 ± 0.7 ms) that matched well with those obtained from an established method using point sources (26.4 ms, 41.2 ms and 34.8 ms). For both experiments, phase maps from fully sampled and compressed-sensing-accelerated k-space data exhibited a high structural similarity (> 0.8) despite a two-fold to three-fold acceleration. CONCLUSIONS: We have illustrated that SPEEDI can provide submillisecond temporal resolution. This capability will likely lead to future exploration of ultrafast, cyclic biomedical processes using MRI.


Subject(s)
Acceleration , Magnetic Resonance Imaging
17.
Stereotact Funct Neurosurg ; 99(3): 212-220, 2021.
Article in English | MEDLINE | ID: mdl-33311023

ABSTRACT

BACKGROUND: Focal cortical dysplasia (FCD) is one of the most important pathogenic findings in patients with extratemporal lobe epilepsy. Magnetic resonance imaging (MRI)-negative is the most important negative factor to predict postoperative seizure freedom; however, FCD-I and part of FCD-IIa are MRI-negative on routine MRI. OBJECTIVES: To explore the diagnostic values of 7T MRI and its new scan sequences in epilepsy patients with FCD-IIa. METHODS: To include patients with focal seizure and suspicious focal abnormal imaging on 3T MRI during preoperative evaluation and perform a 7T MRI scan with white matter-suppressed (WMS) and gray-white matter tissue border enhancement (GWBE) sequences, resective epilepsy surgery, and postoperative pathological finding of FCD-IIa. The preoperative qualitative and localization significance of 7T MRI and 3T MRI in lesions with FCD-IIa was compared, and then, the imaging characteristics of lesions with FCD-IIa on 7T MRI were analyzed. RESULTS: Ten cases were enrolled in this study. Seven tesla MRI presented high spatial resolutions and a high signal-to-noise ratio. WMS and GWBE could selectively suppress the signal of special tissue and improved the possibility of FCD findings. FCD-IIa showed abnormal thickness of gray matter and a blurring border and was hypointense on 7T MRI compared with 3T MRI. Seven patients showed improvement in the qualitative diagnosis strength grade of FCD, and 6 subjects showed improvement in the localization strength grade of the lesion border after careful reading of the 7T MR images. Significant differences were found in the qualitative diagnosis of FCD (p < 0.05) and localization of the lesion border (p < 0.05) between the neuroimaging diagnoses based on 3T MRI and the findings based on 7T MRI. CONCLUSION: 7T MRI with WMS and GWBE sequences shows application value in the preoperative imaging diagnosis of lesions with FCD-IIa in epilepsy patients.


Subject(s)
Epilepsies, Partial , Epilepsy , Malformations of Cortical Development , White Matter , Epilepsy/diagnostic imaging , Humans , Magnetic Resonance Imaging , Malformations of Cortical Development/diagnostic imaging , Malformations of Cortical Development/surgery
18.
Prog Neurobiol ; 207: 101897, 2021 12.
Article in English | MEDLINE | ID: mdl-32818495

ABSTRACT

Attention mechanisms at different cortical layers of human visual cortex remain poorly understood. Using submillimeter-resolution fMRI at 7 Tesla, we investigated the effects of top-down spatial attention on the contrast responses across different cortical depths in human early visual cortex. Gradient echo (GE) T2* weighted BOLD signal showed an additive effect of attention on contrast responses across cortical depths. Compared to the middle cortical depth, attention modulation was stronger in the superficial and deep depths of V1, and also stronger in the superficial depth of V2 and V3. Using ultra-high resolution (0.3 mm in-plane) balanced steady-state free precession (bSSFP) fMRI, a multiplicative scaling effect of attention was found in the superficial and deep layers, but not in the middle layer of V1. Attention modulation of low contrast response was strongest in the middle cortical depths, indicating baseline enhancement or contrast gain of attention modulation on feedforward input. Finally, the additive vs. scaling effect of attention from GE-EPI and bSSFP signals can be explained by stronger nonlinearity of BOLD signals from large than small blood vessels, suggesting multiplicative effect of attention on neural activity. These findings support that top-down spatial attention mainly operates through feedback connections from higher order cortical areas, and a distinct mechanism of attention may also be associated with feedforward input through subcortical pathway.


Subject(s)
Visual Cortex , Brain Mapping , Humans , Magnetic Resonance Imaging , Research Design , Visual Cortex/diagnostic imaging , Visual Cortex/physiology
19.
Magn Reson Imaging ; 66: 86-92, 2020 02.
Article in English | MEDLINE | ID: mdl-30172939

ABSTRACT

We introduce an accelerated gradient echo (GRE) sequence combining simultaneous multislice excitation (SMS) with echo-shifting technique for high spatial resolution blood oxygen level dependent (BOLD) functional MRI (fMRI). The simulation was conducted to optimize scan parameters. To validate the feasibility of the proposed technique, the visual and motor task experiments were performed at 7.0 Tesla (T). The single-shot EPI sequence was also applied in comparison with the proposed technique. The simulation results showed that an optimized flip angle of 9° provided maximal BOLD contrast for our scanning scheme, allowing low power deposition and SMS acceleration factor of 5. Additionally, parallel acquisition imaging with acceleration factor of 2 was utilized, which allowed a total acceleration factor of 10 in volunteer study. The experiment results showed that geometric distortion-free BOLD images with voxel size of 1.0 × 1.0 × 2.5 mm3 were obtained. Significant brain activation was identified in both visual and motor task experiments, which were in accordance with previous investigations. The proposed technique has potential for high spatial resolution fMRI at ultra-high field because of its sufficient BOLD sensitivity as well as improved acquisition speed over conventional GRE-based techniques.


Subject(s)
Brain Mapping/methods , Brain/physiology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adult , Echo-Planar Imaging/methods , Feasibility Studies , Female , Humans , Male , Reference Values , Reproducibility of Results , Young Adult
20.
Neuroradiology ; 60(8): 785-794, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29869697

ABSTRACT

PURPOSE: This study was conducted to determine the benefit of magnetic resonance imaging (MRI) at 7 T in detecting structural lesions and previously unidentified abnormalities in patients with tuberous sclerosis complex (TSC). METHODS: Thirteen patients with TSC (8-36 years, seven males) previously diagnosed by 3 T MRI underwent additional imaging at 7 T, which included T1-weighted magnetization-prepared rapid gradient-echo (MPRAGE), T2-weighted turbo spin echo (TSE), SPACE fluid attenuated inversion recovery (FLAIR), susceptibility weighted imaging (SWI), white matter suppressed (WM-suppressed), and gray-white matter tissue border enhancement (GW-TBE) MPRAGE sequences. Subtle lesions, tuberal morphology, and perituberal cortex abnormalities were examined and compared to those observed at 3 T MRI using standard sequences. RESULTS: Improved visualization of TSC lesions was achieved in all subjects at 7 T compared to 3 T imaging, and three subjects received resective surgery. The 7 T T1- and T2-weighted images had high spatial resolution and provided a clear delineation of the perituberal cortex. SWI revealed abnormal blood vessel morphology. WM-suppressed and GW-TBE protocols, adjusted specifically for TSC imaging, aided in visualizing lesions and uncovered more extensive subtle lesions and abnormalities beyond the conventionally detected tubers. CONCLUSIONS: Due to its high spatial resolution and powerful new imaging protocols, 7 T MRI provided a better evaluation of subtle lesions and perituberal details compared with conventional MRI at 3 T, with potential implications for diagnosis and operative treatment of TSC and its related epilepsy.


Subject(s)
Epilepsy/diagnostic imaging , Magnetic Resonance Imaging/methods , Tuberous Sclerosis/diagnostic imaging , Adolescent , Adult , Child , Electroencephalography , Epilepsy/complications , Epilepsy/surgery , Female , Humans , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Male , Tuberous Sclerosis/complications , Tuberous Sclerosis/surgery