Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
Article in English | MEDLINE | ID: mdl-38934974

ABSTRACT

BACKGROUND: Abnormal ventricular activation at rest is reported in Brugada syndrome (BrS). OBJECTIVES: The aim of this study was to evaluate the usefulness of dynamic changes in ventricular activation during exercise to improve disease phenotyping and diagnosis of BrS. METHODS: Digital 12-lead electrocardiograms during stress testing were analyzed retrospectively at baseline, peak exercise, and recovery in 53 patients with BrS and 52 controls. Biventricular activation was assessed from QRS duration (QRSd), whereas right ventricular activation was assessed from S wave duration in the lateral leads (I and V6) and terminal R wave duration in aVR. Exercise-induced changes in QRS parameters to predict a positive procainamide response were assessed in separate test and validation cohorts with suspected BrS. RESULTS: Baseline electrocardiogram parameters were similar between BrS and controls. QRSd shortened with exercise in all controls but prolonged in all BrS (-6.1 ± 6.0 ms vs 7.1 ± 6.5 ms [P < 0.001] in V6). QRSd in recovery was longer in BrS compared with controls (90 ± 12 ms vs 82 ± 11 ms in V6; P = 0.002). Both groups demonstrated exercise-induced S duration prolongation in V6, with greater prolongation in BrS (8.2 ± 14.3 ms vs 1.2 ± 12.4 ms; P < 0.001). Any exercise-induced QRSd prolongation in V6 differentiated those with a positive vs negative procainamide response with 100% sensitivity and 95% specificity in the test cohort, and 87% sensitivity and 93% specificity in the validation cohort. CONCLUSIONS: Exercise-induced QRSd prolongation is ubiquitous in BrS primarily owing to delayed right ventricular activation. This electrocardiogram phenotype predicts a positive procainamide response and may provide a noninvasive screening tool to aid in the diagnosis of BrS before drug challenge.

3.
Can J Cardiol ; 39(10): 1421-1431, 2023 10.
Article in English | MEDLINE | ID: mdl-37100282

ABSTRACT

BACKGROUND: Atrial low-voltage areas (LVAs) in patients with atrial fibrillation increase the risk of atrial arrhythmia (AA) recurrence after pulmonary vein isolation (PVI). Contemporary LVA prediction scores (DR-FLASH, APPLE) do not include P-wave metrics. We aimed to evaluate the utility of P-wave duration/amplitude ratio (PWR) in quantifying LVA and predicting AA recurrence after PVI. METHODS: In 65 patients undergoing first-time PVI, 12-lead ECGs were recorded during sinus rhythm. PWR was calculated as the ratio between the longest P-wave duration and P-wave amplitude in lead I. High-resolution biatrial voltage maps were collected and LVAs included bipolar electrogram amplitudes < 0.5 mV or < 1.0 mV. An LVA quantification model was created with the use of clinical variables and PWR, and then validated in a separate cohort of 24 patients. Seventy-eight patients were followed for 12 months to evaluate AA recurrence. RESULTS: PWR strongly correlated with left atrial (LA) (< 0.5 mV: r = 0.60; < 1.0 mV: r = 0.68; P < 0.001) and biatrial LVA (< 0.5 mV: r = 0.63; < 1.0 mV: r = 0.70; P < 0.001). Addition of PWR to clinical variables improved model quantification of LA LVA at the < 0.5 mV (adjusted R2 = 0.59 to 0.68) and < 1.0 mV (adjusted R2 = 0.59 to 0.74) cutoffs. In the validation cohort, PWR model-predicted LVA correlated strongly with measured LVA (< 0.5 mV: r = 0.78; < 1.0 mV: r = 0.81; P < 0.001). PWR model was superior to DR-FLASH (area under the receiver operating characteristic curve [AUC] 0.90 vs 0.78; P = 0.030) and APPLE (AUC 0.90 vs 0.67; P = 0.003) at detecting LA LVA and similar at predicting AA recurrence after PVI (AUC 0.67 vs 0.65 and 0.60). CONCLUSION: Our novel PWR model accurately quantifies LVA and predicts AA recurrence after PVI. PWR model-predicted LVA may help guide patient selection for PVI.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Heart Atria , Electrocardiography , ROC Curve , Recurrence , Treatment Outcome
4.
J Am Heart Assoc ; 11(23): e026025, 2022 12 06.
Article in English | MEDLINE | ID: mdl-36444865

ABSTRACT

Background Patients with hypertrophic cardiomyopathy (HCM) are at risk of ventricular arrhythmia (VA) attributed to abnormal electrical activation arising from myocardial fibrosis and myocyte disarray. We sought to quantify intra-QRS peaks (QRSp) in high-resolution ECGs as a measure of abnormal activation to predict late VA in patients with HCM. Methods and Results Prospectively enrolled patients with HCM (n=143, age 53±14 years) with prophylactic implantable cardioverter-defibrillators had 3-minute, high-resolution (1024 Hz), digital 12-lead ECGs recorded during intrinsic rhythm. For each precordial lead, QRSp was defined as the total number of peaks detected in the QRS complex that deviated from a smoothing filtered version of the QRS. The VA end point was appropriate implantable cardioverter-defibrillator therapy during 5-year prospective follow-up. After 5 years, 21 (16%) patients had VA. Patients who were VA positive had greater QRSp (6.0 [4.0-7.0] versus 4.0 [2.0-5.0]; P<0.01) and lower left ventricular ejection fraction (57±11 versus 62±9; P=0.038) compared with patients who were VA negative, but had similar established HCM risk metrics. Receiver operating characteristic analysis revealed that QRSp discriminated VA (area under the curve=0.76; P<0.001), with a QRSp ≥4 achieving 91% sensitivity and 39% specificity. The annual VA rate was greater in patients with QRSp ≥4 versus QRSp <4 (4.4% versus 0.98%; P=0.012). In multivariable Cox regression, age <50 years (hazard ratio [HR], 2.53; P=0.009) and QRSp (HR per QRS peak, 1.41; P=0.009) predicted VA after adjusting for established HCM risk metrics. In patients aged <50 years, the annual VA rate was 0.0% for QRSp <4 compared with 6.9% for QRSp ≥4 (P=0.012). Conclusions QRSp predicted VA in patients with HCM who were eligible for an implantable cardioverter-defibrillator after adjusting for established HCM risk metrics, such that each additional QRS peak increases VA risk by 40%. QRSp <4 was associated with a <1% annual VA risk in all patients, and no VA risk among those aged <50 years. This novel ECG metric may improve patient selection for prophylactic implantable cardioverter-defibrillator therapy by identifying those with low VA risk. These findings require further validation in a lower risk HCM cohort. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT02560844.


Subject(s)
Cardiomyopathy, Hypertrophic , Ventricular Function, Left , Humans , Stroke Volume , Prospective Studies , Electrocardiography , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis
5.
JACC Clin Electrophysiol ; 8(8): 1010-1020, 2022 08.
Article in English | MEDLINE | ID: mdl-35981788

ABSTRACT

BACKGROUND: The diagnosis of Brugada syndrome by 12-lead electrocardiography (ECG) is challenging because the diagnostic type 1 pattern is often transient. OBJECTIVES: This study sought to improve Brugada syndrome diagnosis by using deep learning (DL) to continuously monitor for Brugada type 1 in 24-hour ambulatory 12-lead ECGs (Holters). METHODS: A convolutional neural network was trained to classify Brugada type 1. The training cohort consisted of 10-second standard/high precordial leads from 12-lead ECGs (n = 1,190) and 12-lead Holters (n = 380) of patients with definite and suspected Brugada syndrome. The performance of the trained model was evaluated in 2 testing cohorts of 10-second standard/high precordial leads from 12-lead ECGs (n = 474) and 12-lead Holters (n = 716). RESULTS: DL achieved a receiver-operating characteristic area under the curve of 0.976 (95% CI: 0.973-0.979) in classifying Brugada type 1 from 12-lead ECGs and 0.975 (95% CI: 0.966-0.983) from 12-lead Holters. Compared with cardiologist reclassification of Brugada type 1, DL had similar performance and produced robust results in experiments evaluating scalability and explainability. When DL was applied to consecutive 10-second, clean ECGs from 24-hour 12-lead Holters, spontaneous Brugada type 1 was detected in 48% of patients with procainamide-induced Brugada syndrome and in 33% with suspected Brugada syndrome. DL detected no Brugada type 1 in healthy control patients. CONCLUSIONS: This novel DL model achieved cardiologist-level accuracy in classifying Brugada type 1. Applying DL to 24-hour 12-lead Holters significantly improved the detection of Brugada type 1 in patients with procainamide-induced and suspected Brugada syndrome. DL analysis of 12-lead Holters may provide a robust, automated screening tool before procainamide challenge to aid in the diagnosis of Brugada syndrome.


Subject(s)
Brugada Syndrome , Deep Learning , Wearable Electronic Devices , Brugada Syndrome/diagnosis , Electrocardiography/methods , Humans , Procainamide
6.
J Am Heart Assoc ; 10(23): e022036, 2021 12 07.
Article in English | MEDLINE | ID: mdl-34854315

ABSTRACT

Background Unlike T-wave alternans (TWA), the relation between QRS alternans (QRSA) and ventricular arrhythmia (VA) risk has not been evaluated in hypertrophic cardiomyopathy (HCM). We assessed microvolt QRSA/TWA in relation to HCM risk factors and late VA outcomes in HCM. Methods and Results Prospectively enrolled patients with HCM (n=130) with prophylactic implantable cardioverter-defibrillators underwent digital 12-lead ECG recordings during ventricular pacing (100-120 beats/min). QRSA/TWA was quantified using the spectral method. Patients were categorized as QRSA+ and/or TWA+ if sustained alternans was present in ≥2 precordial leads. The VA end point was appropriate implantable cardioverter-defibrillator therapy over 5 years of follow-up. QRSA+ and TWA+ occurred together in 28% of patients and alone in 7% and 7% of patients, respectively. QRSA magnitude increased with pacing rate (1.9±0.6 versus 6.2±2.0 µV; P=0.006). Left ventricular thickness was greater in QRSA+ than in QRSA- patients (22±7 versus 20±6 mm; P=0.035). Over 5 years follow-up, 17% of patients had VA. The annual VA rate was greater in QRSA+ versus QRSA- patients (5.8% versus 2.0%; P=0.006), with the QRSA+/TWA- subgroup having the greatest rate (13.3% versus 2.6%; P<0.001). In those with <2 risk factors, QRSA- patients had a low annual VA rate compared QRSA+ patients (0.58% versus 7.1%; P=0.001). Separate Cox models revealed QRSA+ (hazard ratio [HR], 2.9 [95% CI, 1.2-7.0]; P=0.019) and QRSA+/TWA- (HR, 7.9 [95% CI, 2.9-21.7]; P<0.001) as the most significant VA predictors. TWA and HCM risk factors did not predict VA. Conclusions In HCM, microvolt QRSA is a novel, rate-dependent phenomenon that can exist without TWA and is associated with greater left ventricular thickness. QRSA increases VA risk 3-fold in all patients, whereas the absence of QRSA confers low VA risk in patients with <2 risk factors. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT02560844.


Subject(s)
Arrhythmias, Cardiac , Cardiomyopathy, Hypertrophic , Arrhythmias, Cardiac/epidemiology , Cardiomyopathy, Hypertrophic/physiopathology , Humans , Risk Factors
7.
Front Physiol ; 12: 704122, 2021.
Article in English | MEDLINE | ID: mdl-34393823

ABSTRACT

Focal sources are potential targets for atrial fibrillation (AF) catheter ablation, but they can be time-consuming and challenging to identify when unipolar electrograms (EGM) are numerous and complex. Our aim was to apply deep learning (DL) to raw unipolar EGMs in order to automate putative focal sources detection. We included 78 patients from the Focal Source and Trigger (FaST) randomized controlled trial that evaluated the efficacy of adjunctive FaST ablation compared to pulmonary vein isolation alone in reducing AF recurrence. FaST sites were identified based on manual classification of sustained periodic unipolar QS EGMs over 5-s. All periodic unipolar EGMs were divided into training (n = 10,004) and testing cohorts (n = 3,180). DL was developed using residual convolutional neural network to discriminate between FaST and non-FaST. A gradient-based method was applied to interpret the DL model. DL classified FaST with a receiver operator characteristic area under curve of 0.904 ± 0.010 (cross-validation) and 0.923 ± 0.003 (testing). At a prespecified sensitivity of 90%, the specificity and accuracy were 81.9 and 82.5%, respectively, in detecting FaST. DL had similar performance (sensitivity 78%, specificity 89%) to that of FaST re-classification by cardiologists (sensitivity 78%, specificity 79%). The gradient-based interpretation demonstrated accurate tracking of unipolar QS complexes by select DL convolutional layers. In conclusion, our novel DL model trained on raw unipolar EGMs allowed automated and accurate classification of FaST sites. Performance was similar to FaST re-classification by cardiologists. Future application of DL to classify FaST may improve the efficiency of real-time focal source detection for targeted AF ablation therapy.

8.
J Cardiovasc Electrophysiol ; 32(6): 1572-1583, 2021 06.
Article in English | MEDLINE | ID: mdl-33694221

ABSTRACT

INTRODUCTION: An important substrate for atrial fibrillation (AF) is fibrotic atrial myopathy. Identifying low voltage, myopathic regions during AF using traditional bipolar voltage mapping is limited by the directional dependency of wave propagation. Our objective was to evaluate directionally independent unipolar voltage mapping, but with far-field cancellation, to identify low-voltage regions during AF. METHODS: In 12 patients undergoing pulmonary vein isolation for AF, high-resolution voltage mapping was performed in the left atrium during sinus rhythm and AF using a roving 20-pole circular catheter. Bipolar electrograms (EGMs) (Bi) < 0.5 mV in sinus rhythm identified low-voltage regions. During AF, bipolar voltage and unipolar voltage maps were created, the latter with (uni-res) and without (uni-orig) far-field cancellation using a novel, validated least-squares algorithm. RESULTS: Uni-res voltage was ~25% lower than uni-orig for both low voltage and normal atrial regions. Far-field EGM had a dominant frequency (DF) of 4.5-6.0 Hz, and its removal resulted in a lower DF for uni-orig compared with uni-res (5.1 ± 1.5 vs. 4.8 ± 1.5 Hz; p < .001). Compared with Bi, uni-res had a significantly greater area under the receiver operator curve (0.80 vs. 0.77; p < .05), specificity (86% vs. 76%; p < .001), and positive predictive value (43% vs. 30%; p < .001) for detecting low-voltage during AF. Similar improvements in specificity and positive predictive value were evident for uni-res versus uni-orig. CONCLUSION: Far-field EGM can be reliably removed from uni-orig using our novel, least-squares algorithm. Compared with Bi and uni-orig, uni-res is more accurate in detecting low-voltage regions during AF. This approach may improve substrate mapping and ablation during AF, and merits further study.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Electrophysiologic Techniques, Cardiac , Heart Atria/diagnostic imaging , Heart Atria/surgery , Humans , Pulmonary Veins/surgery
9.
CJC Open ; 3(1): 71-81, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33458635

ABSTRACT

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is used increasingly to support patients who are in cardiogenic shock. Due to the risk of complications, prediction models may aid in identifying patients who would benefit most from VA-ECMO. One such model is the Survival After Veno-Arterial Extracorporeal Membrane Oxygenation (SAVE) score. Therefore, we wanted to validate the utility of the SAVE score in a contemporary cohort of adult patients. METHODS: Retrospective data were extracted from electronic health records of 120 patients with cardiogenic shock supported with VA-ECMO between 2011 and 2018. The SAVE score was calculated for each patient to predict survival to hospital discharge. We assessed the SAVE score calibration by comparing predicted vs observed survival at discharge. We assessed discrimination with the area under the receiver operating curve using logistic regression. RESULTS: A total of 45% of patients survived to hospital discharge. Survivors had a significantly higher mean SAVE score (-9.3 ± 4.1 in survivors vs -13.1 ± 4.4, respectively; P = 0.001). SAVE score discrimination was adequate (c = 0.77; 95% confidence interval 0.69-0.86; P < 0.001). SAVE score calibration was limited, as observed survival rates for risk classes II-V were higher in our cohort (II: 67% vs 58%; III: 78% vs 42%; IV: 61% vs 30%; and V: 29% vs 18%). CONCLUSIONS: The SAVE score underestimates survival in a contemporary North American cohort of adult patients with cardiogenic shock. Its inaccurate performance could lead to denying ECMO support to patients deemed to be too high risk. Further studies are needed to validate additional predictive models for patients requiring VA-ECMO.


CONTEXTE: L'oxygénation extracorporelle veino-artérielle (ECMO-VA) est de plus en plus utilisée comme assistance pour les patients qui sont en choc cardiogène. En raison du risque de complications, des modèles de prédiction peuvent aider à déterminer quels patients bénéficieraient le plus d'une ECMO-VA. Le score SAVE (Survival After Veno-Arterial Extracorporeal Membrane Oxygenation) est un modèle de ce genre. Par conséquent, nous voulions valider l'utilité du score SAVE dans une cohorte contemporaine de patients adultes. MÉTHODOLOGIE: Des données rétrospectives ont été extraites de dossiers médicaux électroniques de 120 patients atteints d'un choc cardiogène ayant reçu une ECMO-VA entre 2011 et 2018. Le score SAVE a été calculé pour chaque patient afin de prédire la survie au congé de l'hôpital. Nous avons évalué la calibration du score SAVE en comparant la survie prédite au moment du congé et la survie observée. Nous avons évalué la discrimination par l'aire sous la courbe opérationnelle chez le receveur en faisant appel à la régression logistique. RÉSULTATS: Au total, 45 % des patients ont survécu au congé de l'hôpital. Les survivants affichaient un score SAVE moyen considérablement plus élevé (­9,3 ± 4,1 chez les survivants vs ­13,1 ± 4,4; p = 0,001). La discrimination par le score SAVE était adéquate (c = 0,77; intervalle de confiance à 95 % : 0,69 à 0,86; p < 0,001). La calibration du score SAVE était limitée, car les taux pour les classes de risque II à V étaient plus élevés dans notre cohorte (II : 67 % vs 58 %; III : 78 % vs 42 %; IV : 61 % vs 30 %; et V : 29 % vs 18 %). CONCLUSIONS: Le score SAVE sous-estime la survie dans une cohorte nord-américaine contemporaine de patients adultes atteints d'un choc cardiogène. L'inexactitude de ses résultats pourrait faire en sorte qu'une assistance par ECMO serait refusée à des patients jugés comme présentant un risque élevé. D'autres études sont nécessaires pour valider d'autres modèles de prédiction pour les patients ayant besoin d'une ECMO-VA.

10.
J Cardiovasc Electrophysiol ; 32(2): 212-223, 2021 02.
Article in English | MEDLINE | ID: mdl-33179399

ABSTRACT

INTRODUCTION: Defining atrial fibrillation (AF) wave propagation is challenging unless local signal features are discrete or periodic. Periodic focal or rotational activity may identify AF drivers. Our objective was to characterize AF propagation at sites with periodic activation to evaluate the prevalence and relationship between focal and rotational activation. METHODS: We included 80 patients (61 ± 10 years, persistent AF 49%) from the FaST randomized trial that compared the efficacy of adjunctive focal site ablation versus pulmonary vein isolation. Patients underwent left atrial (LA) activation mapping with a 20-pole circular catheter during spontaneous or induced AF. Five-second bipolar and unipolar electrograms in AF were analyzed. Periodic sites were identified by spectral analysis of the bipolar electrogram. Activation maps of periodic sites were constructed using an automated, validated tracking algorithm, and classified into three patterns: focal sites (FS), rotation (RO), or pseudo-rotation (pRO). RESULTS: The most common propagation pattern at periodic sites was FS for 5-s in all patients (4.9 ± 1.9 per patient). RO and pRO were observed in two and seven patients, respectively, but were all transient (3-5 cycles). Activation from a FS evolved into transient RO/pRO in five patients. No patient had autonomous RO/pRO activations. Patients with RO/pRO had greater LA surface area with periodicity (78 ± 7 vs. 63 ± 16%, p = .0002) and shorter LA periodicity CL (166 ± 10 vs. 190±28 ms, p = .0001) than the rest. CONCLUSION: Using automated, regional AF periodicity mapping, FS is more prevalent and temporally stable than RO/pRO. Most RO/pRO evolve from neighboring FS. These findings and their implications for AF maintenance require verification with global, panoramic mapping.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Electrophysiologic Techniques, Cardiac , Heart Atria/surgery , Humans , Middle Aged , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery
11.
J Am Heart Assoc ; 9(17): e016461, 2020 09.
Article in English | MEDLINE | ID: mdl-32806990

ABSTRACT

Background Action potential alternans can induce ventricular tachyarrhythmias and manifest on the surface ECG as T-wave alternans (TWA) and QRS alternans (QRSA). We sought to evaluate microvolt QRSA in cardiomyopathy patients in relation to TWA and ventricular tachyarrhythmia outcomes. Methods and Results Prospectively enrolled cardiomyopathy patients (n=100) with prophylactic defibrillators had 12-lead ECGs recorded during ventricular pacing from 100 to 120 beats/min. QRSA and TWA were quantified in moving 128-beat segments using the spectral method. Segments were categorized as QRSA positive (QRSA+) and/or TWA positive (TWA+) based on ≥2 precordial leads having alternans magnitude >0 and signal:noise >3. Patients were similarly categorized based on having ≥3 consecutive segments with alternans. TWA+ and QRSA+ occurred together in 31% of patients and alone in 18% and 14% of patients, respectively. Although TWA magnitude (1.4±0.4 versus 4.7±1.0 µV, P<0.01) and proportion of TWA+ studies (16% versus 46%, P<0.01) increased with rate, QRSA did not change. QRS duration was longer in QRSA+ than QRSA-negative patients (138±23 versus 113±26 ms, P<0.01). At 3.5 years follow-up, appropriate defibrillator therapy or sustained ventricular tachyarrhythmia was greater in QRSA+ than QRSA-negative patients (30% versus 8%, P=0.02) but similar in TWA+ and TWA-negative patients. Among QRSA+ patients, the event rate was greater in those without TWA (62% versus 21%, P=0.02). Multivariable Cox analysis revealed QRSA+ (hazard ratio [HR], 4.6; 95% CI, 1.5-14; P=0.009) and QRS duration >120 ms (HR, 4.1; 95% CI, 1.3-12; P=0.014) to predict events. Conclusions Microvolt QRSA is novel phenomenon in cardiomyopathy patients that can exist without TWA and is associated with QRS prolongation. QRSA increases the risk of ventricular tachyarrhythmia 4-fold, which merits further study as a risk stratifier.


Subject(s)
Arrhythmias, Cardiac/physiopathology , Cardiomyopathies/physiopathology , Electrocardiography/methods , Heart Ventricles/physiopathology , Tachycardia, Ventricular/physiopathology , Aged , Algorithms , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/prevention & control , Canada/epidemiology , Cardiomyopathies/complications , Cardiomyopathies/therapy , Case-Control Studies , Defibrillators, Implantable/adverse effects , Female , Heart Ventricles/pathology , Humans , Male , Middle Aged , Noise/adverse effects , Prospective Studies , Risk Factors , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/prevention & control
12.
Heart Rhythm ; 17(5 Pt A): 683-691, 2020 05.
Article in English | MEDLINE | ID: mdl-31991116

ABSTRACT

BACKGROUND: Intraoperative mapping has demonstrated focal activations during human atrial fibrillation (AF). These putative AF sources can manifest sustained periodic bipolar and unipolar QS electrograms (EGMs). We have automated the detection of these EGM features using our validated Focal Source and Trigger (FaST) computational algorithm. OBJECTIVE: The purpose of this study was to conduct a randomized controlled pilot evaluating the feasibility and efficacy of FaST mapping/ablation as an adjunct to pulmonary vein isolation (PVI) in reducing AF recurrence. METHODS: We randomized 80 patients with high-burden paroxysmal or persistent AF (age 61 ± 10 years; 75% male) to PVI alone (n = 41) or PVI+FaST mapping/ablation (n = 39). The primary endpoint was time to AF recurrence >30 seconds between 3 and 12 months after 1 procedure. RESULTS: FaST sites were identified in all but 1 patient and were localized to pulmonary vein (PV) (2.1 ± 1.1 per patient) and extra-PV regions (2.8 ± 1.4 per patient). FaST mapping and ablation times were 27 ± 9 minutes and 8.5 ± 5 minutes, respectively. Patients with AF termination during ablation had greater AF cycle length prolongation with PVI+FaST than PVI (Δ20 ± 14 ms vs Δ5 ± 17 ms; P = .046). Freedom from AF recurrence at 12 months was higher in PVI+FaST vs PVI for patients off antiarrhythmic drugs (74% vs 51%; hazard ratio 0.48; 95% confidence interval 0.21-1.08; P = .064) but did not quite reach statistical significance. Major adverse events were similar between the 2 groups. CONCLUSION: In this randomized controlled pilot, real-time FaST mapping provided an intuitive, automated approach for localizing focal AF sources. FaST ablation as an adjunct to PVI may reduce AF recurrence, which requires verification with a larger multicenter trial.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
13.
PLoS One ; 14(6): e0217875, 2019.
Article in English | MEDLINE | ID: mdl-31170231

ABSTRACT

BACKGROUND: Although QRS duration (QRSd) is an important determinant of cardiac resynchronization therapy (CRT) response, non-responder rates remain high. QRS fragmentation can also reflect electrical dyssynchrony. We hypothesized that quantification of abnormal QRS peaks (QRSp) would predict CRT response. METHODS: Forty-seven CRT patients (left ventricular ejection fraction = 23±7%) were prospectively studied. Digital 12-lead ECGs were recorded during native rhythm at baseline and 6 months post-CRT. For each precordial lead, QRSp was defined as the total number of peaks detected on the unfiltered QRS minus those detected on a smoothed moving average template QRS. CRT response was defined as >5% increase in left ventricular ejection fraction post-CRT. RESULTS: Sixty-percent of patients responded to CRT. Baseline QRSd was similar in CRT responders and non-responders, and did not change post-CRT regardless of response. Baseline QRSp was greater in responders than non-responders (9.1±3.5 vs. 5.9±2.2, p = 0.001) and decreased in responders (9.2±3.6 vs. 7.9±2.8, p = 0.03) but increased in non-responders (5.5±2.3 vs. 7.5±2.8, p = 0.049) post-CRT. In multivariable analysis, QRSp was the only independent predictor of CRT response (Odds Ratio [95% Confidence Interval]: 1.5 [1.1-2.1], p = 0.01). ROC analysis revealed QRSp (area under curve = 0.80) to better discriminate response than QRSd (area under curve = 0.67). Compared to QRSd ≥150ms, QRSp ≥7 identified response with similar sensitivity but greater specificity (74 vs. 32%, p<0.05). Amongst patients with QRSd <150ms, more patients with QRSp ≥7 responded than those with QRSp <7 (75 vs. 0%, p<0.05). CONCLUSIONS: Our novel automated QRSp metric independently predicts CRT response and decreases in responders. Electrical dyssynchrony assessed by QRSp may improve CRT selection and track structural remodeling, especially in those with QRSd <150ms.


Subject(s)
Cardiac Resynchronization Therapy , Electrocardiography , Female , Follow-Up Studies , Humans , Logistic Models , Male , Middle Aged , ROC Curve
14.
PLoS One ; 14(4): e0214729, 2019.
Article in English | MEDLINE | ID: mdl-30969986

ABSTRACT

BACKGROUND: T wave alternans (TWA) is an electrocardiographic marker of heightened sudden death risk from ventricular tachyarrhythmias in patients with cardiomyopathy. TWA is evaluated from the 12-lead electrocardiogram, Frank lead, or Holter lead recordings, however these clinical lead configurations will not record TWA from adjacent regions of the body torso. OBJECTIVE: We tested the hypothesis that changing heart rate or ventricular activation may alter the body surface distribution of TWA such that the clinical ECG leads fail to detect TWA in some patients; thereby producing a false-negative test. METHODS: In 28 cardiomyopathy patients (left ventricular ejection fraction 28±6%), 114 unipolar electrograms were recorded across the body torso during incremental atrial pacing, followed by atrioventricular pacing at 100, 110 and 120bpm. TWA was measured from each unipolar electrogram using the spectral method. A clinically positive TWA test was defined as TWA magnitude (Valt) ≥1.9 uV with k ≥3 at ≤110bpm. RESULTS: Maximum Valt (TWAmax) was greater from the body torso than clinical leads during atrial (p<0.005) and atrioventricular pacing (p<0.005). TWAmax was most prevalent in the right lower chest with atrial pacing 100 bpm and shifted to the left lower chest at 120 bpm. TWAmax was most prevalent in left lower chest with atrioventricular pacing at 100 bpm and shifted to the left upper chest at 120 bpm. Using the body torso as a gold standard, the false-negative rate for clinically positive TWA with clinical leads was 21% during atrial and 11% during atrioventricular pacing. Due to TWA signal migration outside the clinical leads, clinically positive TWA became false-negative when pacing mode was switched (atrial→atrioventricular pacing) in 21% of patients. CONCLUSIONS: The body surface distribution of TWA is modulated by heart rate and the sequence of ventricular activation in patients with cardiomyopathy, which can give rise to modest false-negative TWA signal detection using standard clinical leads.


Subject(s)
Body Surface Potential Mapping , Cardiomyopathies/physiopathology , Electrocardiography , Action Potentials , Aged , Cardiac Pacing, Artificial , Death, Sudden, Cardiac/prevention & control , Female , Heart Rate , Humans , Male , Middle Aged , Risk Assessment , Ventricular Function, Left
15.
Pacing Clin Electrophysiol ; 42(2): 189-200, 2019 02.
Article in English | MEDLINE | ID: mdl-30515873

ABSTRACT

BACKGROUND: QRS abnormalities may not be apparent in sinus rhythm in electrically stable cardiomyopathy patients who can have quiescent but highly arrhythmogenic substrate. Here, we test the hypothesis that differential changes in QRS construction during right-ventricular apex pacing (RVP) as opposed to atrial pacing (AP) will identify latent substrate for ventricular arrhythmias (VA) and death. METHODS: Forty patients with cardiomyopathy free of VA underwent baseline 114-electrode body-surface electrocardiogram during AP (100 beats per minute [bpm]) and RVP (100 and 120 bpm). The filtered-averaged QRS at each electrode was deconstructed into individual intra-QRS and post-QRS ventricular myopotentials (VMP ). The primary outcome was VA or death. Prognostic accuracy of VMP was validated using V1 to V6 leads in another prospective cohort of 44-cardiomyopathy patients. RESULTS: Twenty-six patients were eligible for initial analysis. After 5 ± 2 years of follow-up, eight (31%) patients had VA (VAPos ) while rest were uneventful (VANeg ). During AP100 , VAPos patients expressed more VMP than VANeg patients (16 ± 1 vs 12 ± 1, P = 0.02). RVP100 and RVP120 in VAPos patients introduced an additional 5.5 ± 0.5 and 6.0 ± 0.5 VMP (P < 0.0001 vs AP100 ). The relative change with RVP120 versus AP100 in VANeg patients exceeded VAPos patients by 1.2 ± 0.5 VMP (P = 0.03). Increment in VMP count of <8 in lead-V5 with RVP120 compared to AP100 best predicted VA (area under curve 0.81, P = 0.01). In the validation cohort, primary outcome occurred in 13 (33%) patients. Native QRS features and AP100 alone failed to predict primary outcome. Patients with increment in VMP count of <8 in lead-V5 with RVP120 versus AP100 had 7.9-fold increased risk of primary outcome (95% confidence interval 1.01, 61.61; P = 0.049). CONCLUSION: Cardiomyopathy patients at risk of VA or death perturb the QRS less than low-risk patients with differential pacing. This functional response may be useful to identify arrhythmogenic substrate.


Subject(s)
Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/mortality , Electrocardiography , Aged , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Cardiomyopathies/complications , Cardiomyopathies/physiopathology , Electrocardiography/methods , Electrophysiologic Techniques, Cardiac , Female , Humans , Male , Middle Aged , Prospective Studies , Risk Assessment
16.
PLoS One ; 13(6): e0199637, 2018.
Article in English | MEDLINE | ID: mdl-29953465

ABSTRACT

BACKGROUND: T-wave alternans (TWA), a marker of electrical instability, can be modulated by cardiac resynchronization therapy (CRT). The relationship between TWA and heart failure response to CRT has not been clearly defined. METHODS AND RESULTS: In 40-patients (age 65±11 years, left ventricular ejection-fraction [LVEF] 23±7%), TWA was evaluated prospectively at median of 2 months (baseline) and 8 months (follow-up) post-CRT implant. TWA-magnitude (Valt >0µV, k≥3), its duration (d), and burden (Valt ·d) were quantified in moving 128-beat segments during incremental atrial (AAI, native-TWA) and atrio-biventricular (DDD-CRT) pacing. The immediate and long-term effect of CRT on TWA was examined. Clinical response to CRT was defined as an increase in LVEF of ≥5%. Native-TWA was clinically significant (Valt ≥1.9µV, k≥3) in 68% of subjects at baseline. Compared to native-TWA at baseline, DDD-CRT pacing at baseline and follow-up reduced the number of positive TWA segments, peak-magnitude, longest-duration and peak-burden of TWA (44±5 to 33±5 to 28±4%, p = 0.02 and 0.002; 5.9±0.8 to 4.1±0.7 to 3.8±0.7µV, p = 0.01 and 0.01; 97±9 to 76±8 to 67±8sec, p = 0.004 and <0.001; and 334±65 to 178±58 to 146±54µV.sec, p = 0.01 and 0.004). In addition, the number of positive segments and longest-duration of native-TWA diminished during follow-up (44±5 to 35±6%, p = 0.044; and 97±9 to 81±9sec, p = 0.02). Clinical response to CRT was observed in 71% of patients; the reduction in DDD-CRT paced TWA both at baseline and follow-up was present only in responders (interaction p-values <0.1). CONCLUSION: Long-term CRT reduces the prevalence and magnitude of TWA. This CRT induced beneficial electrical remodeling is a marker of clinical response after CRT.


Subject(s)
Cardiac Resynchronization Therapy , Cardiomyopathy, Dilated/physiopathology , Cardiomyopathy, Dilated/therapy , Electrocardiography , Aged , Cardiomyopathy, Dilated/diagnosis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Signal Processing, Computer-Assisted , Treatment Outcome
17.
Article in English | MEDLINE | ID: mdl-28705874

ABSTRACT

BACKGROUND: Cardiomyopathy patients are at risk of sudden death, typically from scar-related abnormalities of electrical activation that promote ventricular tachyarrhythmias. Abnormal intra-QRS peaks may provide a measure of altered activation. We hypothesized that quantification of such QRS peaks (QRSp) in high-resolution ECGs would predict arrhythmic events in implantable cardioverter-defibrillator (ICD)-eligible cardiomyopathy patients. METHODS AND RESULTS: Ninety-nine patients with ischemic or non-ischemic dilated cardiomyopathy undergoing prophylactic ICD implantation were prospectively enrolled (age 62±11 years, left ventricular ejection fraction 27±7%). High-resolution (1024 Hz) digital 12-lead ECGs were recorded during intrinsic rhythm. QRSp was quantified for each precordial lead as the total number of low-amplitude deflections that deviated from their respective naive QRS template. The primary end point of arrhythmic events was defined as appropriate ICD therapy or sustained ventricular tachyarrhythmias. After a median follow-up of 24 (15-43) months, 20 (20%) patients had arrhythmic events. Both QRSp and QRS duration were greater in those with arrhythmic events (both P<0.001) and this was consistent for QRSp for both cardiomyopathy types. In a multivariable Cox regression model that included age, left ventricular ejection fraction, QRS duration, and QRSp, only QRSp was an independent predictor of arrhythmic events (hazard ratio, 2.1; P<0.001). Receiver operating characteristic analysis revealed that a QRSp ≥2.25 identified arrhythmic events with greater sensitivity (100% versus 70%, P<0.05) and negative predictive value (100% versus 89%, P<0.05) than QRS duration ≥120 ms. CONCLUSIONS: QRSp measured from high-resolution digital 12-lead ECGs independently predicts ventricular tachyarrhythmias in ICD-eligible cardiomyopathy patients. This novel QRS morphology index has the potential to improve sudden death risk stratification and patient selection for prophylactic ICD therapy.


Subject(s)
Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/physiopathology , Electrocardiography, Ambulatory , Arrhythmias, Cardiac/prevention & control , Defibrillators, Implantable , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Risk Factors , Sensitivity and Specificity
18.
JACC Clin Electrophysiol ; 3(11): 1220-1228, 2017 11.
Article in English | MEDLINE | ID: mdl-29759616

ABSTRACT

OBJECTIVES: This study sought to evaluate the spatial relationships of focal electrical sources (FSs) to complex fractionated atrial electrograms (CFAE) and continuous electrical activity (CEA). BACKGROUND: Fractionated atrial electrograms have been associated with atrial fibrillation (AF) drivers in computational studies and represent ablation targets in the management of persistent AF. METHODS: We included a subset of 66 patients (age: 63 [56, 67] years, 69% persistent AF) with electroanatomic data from the SELECT AF (Selective complex fractionated atrial electrograms targeting for atrial fibrillation) randomized control trial that compared the efficacy of CFAE with CEA ablation in AF patients undergoing pulmonary vein antral ablation. Focal sources were identified based on bipolar electrogram periodicity and QS unipolar electrogram morphology. RESULTS: A total of 77 FSs (median: 1 [1st quartile, 3rd quartile: 1, 2] per patient) were identified most commonly in the pulmonary vein antrum and left atrial appendage. The proportions of FSs inside CFAE and CEA regions were similar (13% vs. 1.3%, respectively; p = 0.13). Focal sources were more likely to be on the border zone of CFAEs than in CEAs (49% vs. 7.8%, respectively; p = 0.012). Following ablation, 53% of patients had ≥1 unablated extrapulmonary vein FS. The median number of unablated FS was higher in patients with AF recurrence post ablation than in patients without (median: 1 [0, 1] vs. 0 [0, 1], respectively; p = 0.026). CONCLUSIONS: One-half of the FSs detected during AF localized to the border of CFAE areas, whereas most of the FSs were found outside CEA areas. CFAE or CEA ablation leaves a number of FS unablated, which is associated with AF recurrence. These findings suggest that many CFAEs may arise from passive wave propagation, remote from FS, which may limit their therapeutic efficacy in AF substrate modification.


Subject(s)
Atrial Fibrillation/therapy , Catheter Ablation/adverse effects , Electrophysiologic Techniques, Cardiac/methods , Heart Atria/physiopathology , Aged , Algorithms , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Body Surface Potential Mapping , Catheter Ablation/methods , Cost of Illness , Electricity , Electrophysiologic Techniques, Cardiac/instrumentation , Female , Follow-Up Studies , Heart Atria/innervation , Heart Atria/surgery , Heart Conduction System/physiopathology , Humans , Male , Middle Aged , Pulmonary Veins/innervation , Pulmonary Veins/physiopathology , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
19.
Pacing Clin Electrophysiol ; 39(7): 642-51, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27027856

ABSTRACT

BACKGROUND: Nonsustained ventricular tachycardia (NSVT) detected by ambulatory Holter (Holter NSVT) is a major risk factor for sudden cardiac death in hypertrophic cardiomyopathy (HCM). We hypothesized that the prognostic utility of Holter NSVT in HCM would improve with prolonged monitoring and a higher heart rate cut-off for detection. METHODS: We enrolled 60 patients (44 ± 14 years) with HCM, who had a prophylactic implantable cardioverter defibrillator (ICD). Positive Holter NSVT (prior to implant) was defined as ≥3 beats at ≥120 beats per minute (bpm). We assessed the prevalence of rapid NSVT (RNSVT) detected by their ICD within 12 months of its implant, defined as 4-16 beats at ≥150-200 bpm. The primary outcome was appropriate ICD therapy (antitachycardia pacing and shocks) for sustained ventricular arrhythmia (VA). RESULTS: Holter NSVT was detected in 34 patients. RNSVT occurred in 21 (35%) patients of whom five did not have Holter NSVT. Over a median follow-up of 61 (interquartile range 29, 129) months after ICD implant, nine patients had VA. RNSVT, but not Holter NSVT, was significantly associated with VA (hazard ratio 6.2, 95% confidence interval [1.3-30], P = 0.01) by multivariable Cox regression analysis that included conventional risk factors. Receiver operating characteristic analysis for RNSVT (area under curve 0.80, P = 0.005) showed that the occurrence of ≥2 episodes of RNSVT discriminated patients for VA optimally (sensitivity 78%, specificity 84%, positive predictive value 47%, negative predictive value 96%). CONCLUSIONS: In this pilot study, RNSVT detected by continuous monitoring independently predicted VA in HCM and offered superior discrimination of VA risk compared to conventional risk factors, including Holter NSVT. Future studies are needed to validate these findings in a larger, unselected HCM cohort.


Subject(s)
Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnosis , Diagnosis, Computer-Assisted/methods , Electrocardiography, Ambulatory/methods , Tachycardia, Ventricular/complications , Tachycardia, Ventricular/diagnosis , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Pilot Projects , Reproducibility of Results , Risk Assessment/methods , Sensitivity and Specificity , Young Adult
20.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 3473-3477, 2016 Aug.
Article in English | MEDLINE | ID: mdl-28269048

ABSTRACT

Rotors are rotating electrical waves that may sustain atrial fibrillation (AF); thereby providing therapeutic targets for catheter ablation. We propose a method for identifying rotors from circular catheter recordings of bipolar intracardiac electrograms (EGM) during AF. We use dominant frequency-based periodicity detection along with a graph search algorithm to identify the most dominant periodic activations or peaks of interest in each bipolar EGM recorded by a multipolar circular catheter. We then track the activations across catheter bipoles to determine whether they conform to the rotational pattern of a rotor. The performance of the proposed method is tested on simulated bipolar EGM arrays containing rotor activation corrupted by noise and complex aperiodic signal features. The method is shown to perform with high accuracy (up to 98% sensitivity and 100% specificity) in detecting simulated rotors and may serve to guide rotor ablation in patients with AF.


Subject(s)
Algorithms , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Electrophysiologic Techniques, Cardiac/methods , Atrial Fibrillation/physiopathology , Catheter Ablation/methods , Electrophysiologic Techniques, Cardiac/instrumentation , Female , Humans , Male , Middle Aged , Pilot Projects , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...