Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Infect Dis ; 139: 168-170, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38151115

ABSTRACT

We evaluated the performance of 12 lateral flow devices by assessing their analytical sensitivity for SARS-CoV-2 variant BA.2.86. Kits from ACON, Orient Gene, Xiamen Biotime, Getein, and SureScreen detected variant BA.2.86 to sufficient sensitivity levels, comparable to those observed with previous Omicron variants. The stocks of lateral flow devices currently held by the UK government do not currently need changing for deployment for this variant.


Subject(s)
COVID-19 , Humans , SARS-CoV-2 , Government
2.
Microbiol Spectr ; 10(1): e0228921, 2022 02 23.
Article in English | MEDLINE | ID: mdl-35196807

ABSTRACT

In March 2020, the Rare and Imported Pathogens Laboratory at the UK Health Security Agency (UKHSA) (formerly Public Health England [PHE]) Porton Down, was tasked by the Department of Health and Social Care with setting up a national surveillance laboratory facility to study SARS-CoV-2 antibody responses and population-level sero-surveillance in response to the growing SARS-CoV-2 outbreak. In the following 12 months, the laboratory tested more than 160,000 samples, facilitating a wide range of research and informing UKHSA, DHSC, and UK government policy. Here we describe the implementation and use of the Euroimmun anti-SARS-CoV-2 IgG assay and provide an extended evaluation of its performance. We present a markedly improved overall sensitivity of 91.39% (≥14 days 92.74%, ≥21 days 93.59%) compared to our small-scale early study, and a specificity of 98.56%. In addition, we detail extended characteristics of the Euroimmun assay: intra- and interassay precision, correlation to neutralization, and assay linearity. IMPORTANCE Serology assays have been useful in determining those with previous SARS-CoV-2 infection in a wide range of research and serosurveillance projects. However, assays vary in their sensitivity at detecting SARS-CoV-2 antibodies. Here, we detail an extended evaluation and characterization of the Euroimmun anti-SARS-CoV-2 IgG assay, one that has been widely used within the United Kingdom on over 160,000 samples to date.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/blood , Immunoglobulin G/blood , SARS-CoV-2/immunology , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/virology , Humans , Public Health , Reagent Kits, Diagnostic , SARS-CoV-2/genetics , Sensitivity and Specificity , United Kingdom/epidemiology
3.
J Clin Microbiol ; 54(1): 114-9, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26537445

ABSTRACT

Rapid Ebola virus (EBOV) detection is crucial for appropriate patient management and care. The performance of the FilmArray BioThreat-E test (v2.5) using whole-blood samples was evaluated in Sierra Leone and the United Kingdom and was compared with results generated by a real-time Ebola Zaire PCR reference method. Samples were tested in diagnostic laboratories upon availability, included successive samples from individual patients, and were heat treated to facilitate EBOV inactivation prior to PCR. The BioThreat-E test had a sensitivity of 84% (confidence interval [CI], 64% to 95%) and a specificity of 89% (CI, 73% to 97%) in Sierra Leone (n = 60; 44 patients) and a sensitivity of 75% (CI, 19% to 99%) and a specificity of 100% (CI, 97% to 100%) in the United Kingdom (n = 108; 70 patients) compared to the reference real-time PCR. Statistical analysis (Fisher's exact test) indicated there was no significant difference between the methods at the 99% confidence level in either country. In 9 discrepant results (5 real-time PCR positives and BioThreat-E test negatives and 4 real-time PCR negatives and BioThreat-E test positives), the majority (n = 8) were obtained from samples with an observed or probable low viral load. The FilmArray BioThreat-E test (v2.5) therefore provides an attractive option for laboratories (either in austere field settings or in countries with an advanced technological infrastructure) which do not routinely offer an EBOV diagnostic capability.


Subject(s)
Blood/virology , Ebolavirus/isolation & purification , Hemorrhagic Fever, Ebola/diagnosis , Molecular Diagnostic Techniques/methods , Specimen Handling/methods , Ebolavirus/genetics , Hemorrhagic Fever, Ebola/virology , Hot Temperature , Humans , Sensitivity and Specificity , Sierra Leone , Time Factors , United Kingdom
4.
Appl Environ Microbiol ; 79(2): 714-7, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23124233

ABSTRACT

The poly-γ-d-glutamic acid capsule of Bacillus anthracis is a barrier to infection by B. anthracis-specific bacteriophages. Capsule expression was found to completely inhibit lytic infection by γ phage, an observation supported by the demonstration that this phage does not elaborate a hydrolase that would facilitate penetration through the protective capsule outer layer.


Subject(s)
Bacillus Phages/physiology , Bacillus anthracis/virology , Bacterial Capsules/metabolism , Bacteriolysis , Polyglutamic Acid/metabolism , Bacillus Phages/enzymology , Bacillus Phages/genetics , Bacillus Phages/growth & development , Bacillus anthracis/metabolism , DNA, Viral/chemistry , DNA, Viral/genetics , Hydrolases/genetics , Molecular Sequence Data , Sequence Analysis, DNA
SELECTION OF CITATIONS
SEARCH DETAIL
...