Pilot Feasibility Stud ; 9(1): 129, 2023 Jul 24.
Article in English | MEDLINE | ID: mdl-37488566

ABSTRACT

BACKGROUND: Extubation failure, defined as reintubation within 48 h, is associated with increased intensive care unit (ICU) length of stay and higher mortality risk. One cause of extubation failure is secretion retention, resulting from an inability to cough effectively. Mechanical insufflation-exsufflation (MI-E) simulates a cough aiding secretion clearance. However, MI-E is not routinely used in the ICU for invasively ventilated patients. This study aims to determine feasibility and acceptability of a randomised controlled trial (RCT) examining MI-E use to promote extubation success in intubated, ventilated adults. METHODS: It is a single-centre, feasibility RCT with semi-structured interviews, economic scoping, and exploratory physiology study. The feasibility RCT (n = 50) will compare standard care to a MI-E protocol including a minimum of two MI-E sessions via the endotracheal tube prior to extubation. Post-extubation, MI-E will be delivered via facemask or mouthpiece up to two times/day for 48 h. MI-E settings will be individualised. All patients will receive standard care (no MI-E) in relation to mechanical ventilation, weaning, rehabilitation, physiotherapy techniques such as positioning, manual airway clearance techniques, manual/ventilator hyperinflation, endotracheal suctioning, and nebulisation. Clinical data collection will occur before, on completion, and 5-min post-physiotherapy sessions (intervention/control arms). Resource use will be calculated for each 24-h period. Analyses will be descriptive and address feasibility outcomes including participant recruitment and attrition, proportion of MI-E treatment sessions completed, dataset completeness, and frequency of adverse events and acceptability. Semi-structured online interviews informed by the Theoretical Framework of Acceptability (TFA) with patients, clinicians, and family members will explore the acceptability of the MI-E intervention and study processes. Interview data will be analysed using reflexive thematic analysis based on TFA domains through first-level coding. The embedded physiology study will use electrical impedance tomography and lung ultrasound to explore lung recruitment and de-recruitment during MI-E in a subset of 5-10 patients. DISCUSSION: This study will examine feasibility and acceptability of a RCT protocol of MI-E to promote extubation success. Study findings will inform design modification and conduct of a future adequately powered trial. Furthermore, the study will contribute and advance the understanding of MI-E use in critically ill intubated adults. TRIAL REGISTRATION: ISRCTN 24603037; IRAS 303674.

3.
Respir Care ; 67(8): 1043-1057, 2022 08.
Article in English | MEDLINE | ID: mdl-35610033

ABSTRACT

Mechanical insufflation-exsufflation (MI-E) is traditionally used in the neuromuscular population. There is growing interest of MI-E use in invasively ventilated critically ill adults. We aimed to map current evidence on MI-E use in invasively ventilated critically ill adults. Two authors independently searched electronic databases MEDLINE, Embase, and CINAHL via the Ovid platform; PROSPERO; Cochrane Library; ISI Web of Science; and International Clinical Trials Registry Platform between January 1990-April 2021. Inclusion criteria were (1) adult critically ill invasively ventilated subjects, (2) use of MI-E, (3) study design with original data, and (4) published from 1990 onward. Data were extracted by 2 authors independently using a bespoke extraction form. We used Mixed Methods Appraisal Tool to appraise risk of bias. Theoretical Domains Framework was used to interpret qualitative data. Of 3,090 citations identified, 28 citations were taken forward for data extraction. Main indications for MI-E use during invasive ventilation were presence of secretions and mucus plugging (13/28, 46%). Perceived contraindications related to use of high levels of positive pressure (18/28, 68%). Protocolized MI-E settings with a pressure of ±40 cm H2O were most commonly used, with detail on timing, flow, and frequency of prescription infrequently reported. Various outcomes were re-intubation rate, wet sputum weight, and pulmonary mechanics. Only 3 studies reported the occurrence of adverse events. From qualitative data, the main barrier to MI-E use in this subject group was lack of knowledge and skills. We concluded that there is little consistency in how MI-E is used and reported, and therefore, recommendations about best practices are not possible.


Subject(s)
Critical Illness , Insufflation , Adult , Critical Illness/therapy , Humans , Insufflation/methods , Lung , Respiration, Artificial/adverse effects
6.
Syst Rev ; 9(1): 287, 2020 12 08.
Article in English | MEDLINE | ID: mdl-33292485

ABSTRACT

BACKGROUND: Critically ill patients receiving invasive ventilation are at risk of sputum retention. Mechanical insufflation-exsufflation (MI-E) is a technique used to mobilise sputum and optimise airway clearance. Recently, interest has increased in the use of mechanical insufflation-exsufflation for invasively ventilated critically ill adults, but evidence for the feasibility, safety and efficacy of this treatment is sparse. The aim of this scoping review is to map current and emerging evidence on the feasibility, safety and efficacy of MI-E for invasively ventilated adult patients with the aim of highlighting knowledge gaps and identifying areas for future research. Specific research questions aim to identify information informing indications and contraindications to the use of MI-E in the invasively ventilated adult, MI-E settings used, outcome measures reported within studies, adverse effects reported and perceived barriers and facilitators to using MI-E reported. METHODS: We will search electronic databases MEDLINE, EMBASE, CINAHL using the OVID platform, PROSPERO, The Cochrane Library, ISI Web of Science and the International Clinical Trials Registry Platform. Two authors will independently screen citations, extract data and evaluate risk of bias using the Mixed Methods Appraisal Tool. Studies included will present original data and describe MI-E in invasively ventilated adult patients from 1990 onwards. Our exclusion criteria are studies in a paediatric population, editorial pieces or letters and animal or bench studies. Search results will be presented in a PRISMA study flow diagram. Descriptive statistics will be used to summarise quantitative data. For qualitative data relating to barriers and facilitators, we will use content analysis and the Theoretical Domains Framework (TDF) as a conceptual framework. Additional tables and relevant figures will present data addressing our research questions. DISCUSSION: Our findings will enable us to map current and emerging evidence on the feasibility, safety and efficacy of MI-E for invasively ventilated critically ill adult patients. These data will provide description of how the technique is currently used, support healthcare professionals in their clinical decision making and highlight areas for future research in this important clinical area. SYSTEMATIC REVIEW REGISTRATION: Open Science Framework submitted on 9 July 2020.  https://osf.io/mpksq/ .


Subject(s)
Critical Illness , Insufflation , Adult , Child , Cough , Humans , Lung , Respiration, Artificial , Review Literature as Topic , Systematic Reviews as Topic
7.
BMJ Open Respir Res ; 7(1)2020 09.
Article in English | MEDLINE | ID: mdl-32895247

ABSTRACT

The global pandemic of COVID-19 has challenged the management of hypoxaemic respiratory failure and strained intensive care unit resources. While prone positioning (PP) is an established therapy in mechanically ventilated patients with acute respiratory distress syndrome (ARDS), its role in conscious patients is less well defined. We retrospectively reviewed our experience of implementing early PP in a cohort of 24 patients with acute hypoxaemic respiratory failure due to COVID-19 who required support with continuous positive airway pressure (CPAP). The use of PP alongside CPAP significantly increased both the ROX index and arterial oxygen pressure:fractional inspired oxygen (PaO2:FiO2) ratio from baseline values (ROX index: 7.0±2.5 baseline vs 11.4±3.7 CPAP+PP, p<0.0001; PaO2:FiO2 ratio: 143±73 mm Hg baseline vs 252±87 mm Hg CPAP+PP, p<0.01), and the changes to both the ROX index and PaO2:FiO2 ratio remained significant 1 hour after cessation of proning. The mean duration of PP in the first 24 hours was 8±5 hours. Few complications were observed and PP was continued for a mean of 10±5 days. From our experience in a dedicated COVID-19 respiratory high care unit, PP alongside CPAP therapy was feasible, tolerated, safe and improved oxygenation. The use of conscious PP in ARDS warrants further investigation in randomised controlled trials.


Subject(s)
Betacoronavirus , Continuous Positive Airway Pressure/methods , Coronavirus Infections/therapy , Patient Positioning/methods , Pneumonia, Viral/therapy , COVID-19 , Cohort Studies , Female , Humans , Male , Middle Aged , Pandemics , Prone Position , Retrospective Studies , SARS-CoV-2 , Time , Treatment Outcome , Wakefulness
8.
ERJ Open Res ; 6(1)2020 Jan.
Article in English | MEDLINE | ID: mdl-32166088

ABSTRACT

The Respiratory Intensive Care Assembly of the European Respiratory Society is delighted to present the highlights from the 2019 International Congress in Madrid, Spain. We have selected four sessions that discussed recent advances in a wide range of topics: from acute respiratory failure to cough augmentation in neuromuscular disorders and from extra-corporeal life support to difficult ventilator weaning. The subjects are summarised by early career members in close collaboration with the Assembly leadership. We aim to give the reader an update on the most important developments discussed at the conference. Each session is further summarised into a short list of take-home messages.

9.
J Intensive Care Soc ; 21(4): 283-289, 2020 Nov.
Article in English | MEDLINE | ID: mdl-34093728

ABSTRACT

INTRODUCTION: Despite potential benefits, it is not known how widely physiotherapists use mechanical insufflation-exsufflation devices on UK adult intensive care units. This survey aimed to describe mechanical insufflation-exsufflation use in UK adult intensive care units. METHODS: Cross-sectional electronic survey of physiotherapists working in a permanent post on adult intensive care units. RESULTS: One hundred and sixty-six complete surveys were available for analysis, reflecting a diverse geographical spread. Nearly all (98%; 163/166) clinicians had access to mechanical insufflation-exsufflation. The estimated frequency of use varied, with the majority reporting weekly or monthly use (52/163, 32%; 50/163, 31%, respectively). Nearly all clinicians (99%) used mechanical insufflation-exsufflation with extubated patients. In contrast, around half of respondents (86/163, 53%) used mechanical insufflation-exsufflation with intubated patients, with a range of perceived barriers reported. CONCLUSIONS: Mechanical insufflation-exsufflation devices are widely available on UK adult intensive care units, with use more common in extubated patients. Barriers to mechanical insufflation-exsufflation use in the intubated population warrant further investigation.

10.
ERJ Open Res ; 5(1)2019 Feb.
Article in English | MEDLINE | ID: mdl-30847349

ABSTRACT

The respiratory intensive care Assembly of the European Respiratory Society is proud to present a summary of several important sessions held at the International Congress in Paris in 2018. For the highly esteemed reader who may have missed the Congress, a concise review was written on three topics: the state-of-the-art session on respiratory critical care, hot topics in weaning and the best abstracts in noninvasive ventilation.