1.
Anal Chem ; 95(14): 5858-5866, 2023 04 11.
Article in English | MEDLINE | ID: mdl-36996326

ABSTRACT

Toxicity testing is currently undergoing a paradigm shift from examining apical end points such as death, to monitoring sub-lethal toxicity in vivo. In vivo nuclear magnetic resonance (NMR) spectroscopy is a key platform in this endeavor. A proof-of-principle study is presented which directly interfaces NMR with digital microfluidics (DMF). DMF is a "lab on a chip" method allowing for the movement, mixing, splitting, and dispensing of µL-sized droplets. The goal is for DMF to supply oxygenated water to keep the organisms alive while NMR detects metabolomic changes. Here, both vertical and horizontal NMR coil configurations are compared. While a horizontal configuration is ideal for DMF, NMR performance was found to be sub-par and instead, a vertical-optimized single-sided stripline showed most promise. In this configuration, three organisms were monitored in vivo using 1H-13C 2D NMR. Without support from DMF droplet exchange, the organisms quickly showed signs of anoxic stress; however, with droplet exchange, this was completely suppressed. The results demonstrate that DMF can be used to maintain living organisms and holds potential for automated exposures in future. However, due to numerous limitations of vertically orientated DMF, along with space limitations in standard bore NMR spectrometers, we recommend future development be performed using a horizontal (MRI style) magnet which would eliminate practically all the drawbacks identified here.


Subject(s)
Magnetic Resonance Imaging , Microfluidics , Magnetic Resonance Spectroscopy/methods , Metabolomics/methods , Lab-On-A-Chip Devices
2.
ACS Appl Mater Interfaces ; 15(5): 6326-6337, 2023 Feb 08.
Article in English | MEDLINE | ID: mdl-36696478

ABSTRACT

Fouling at liquid-solid interfaces is a pernicious problem for a wide range of applications, including those that are implemented by digital microfluidics (DMF). There are several strategies that have been used to combat surface fouling in DMF, the most common being inclusion of amphiphilic surfactant additives in the droplets to be manipulated. Initial studies relied on Pluronic additives, and more recently, Tetronic additives have been used, which has allowed manipulation of complex samples like serum and whole blood. Here, we report our evaluation of 19 different Pluronic and Tetronic additives, with attempts to determine (1) the difference in antifouling performance between the two families, (2) the structural similarities that predict exceptional antifouling performance, and (3) the mechanism of the antifouling behavior. Our analysis shows that both Pluronic and Tetronic additives with modest molar mass, poly(propylene oxide) (PPO) ≥50 units, poly(ethylene oxide) (PEO) mass percentage ≤50%, and hydrophilic-lipophilic balance (HLB) ca. 13-15 allow for exceptional antifouling performance in DMF. The most promising candidates, P104, P105, and T904, were able to support continuous movement of droplets of serum for more than 2 h, a result (for devices operating in air) previously thought to be out of reach for this technique. Additional results generated using device longevity assays, intrinsic fluorescence measurements, dynamic light scattering, asymmetric flow field flow fractionation, supercritical angle fluorescence microscopy, atomic force microscopy, and quartz crystal microbalance measurements suggest that the best-performing surfactants are more likely to operate by forming a protective layer at the liquid-solid interface than by complexation with proteins. We propose that these results and their implications are an important step forward for the growing community of users of this technique, which may provide guidance in selecting surfactants for manipulating biological matrices for a wide range of applications.


Subject(s)
Biofouling , Poloxamer , Humans , Poloxamer/chemistry , Surface-Active Agents , Microfluidics , Biofouling/prevention & control , Polyethylene Glycols/chemistry
3.
Angew Chem Int Ed Engl ; 58(43): 15372-15376, 2019 Oct 21.
Article in English | MEDLINE | ID: mdl-31449724

ABSTRACT

Microcoil nuclear magnetic resonance (NMR) has been interfaced with digital microfluidics (DMF) and is applied to monitor organic reactions in organic solvents as a proof of concept. DMF permits droplets to be moved and mixed inside the NMR spectrometer to initiate reactions while using sub-microliter volumes of reagent, opening up the potential to follow the reactions of scarce or expensive reagents. By setting up the spectrometer shims on a reagent droplet, data acquisition can be started immediately upon droplet mixing and is only limited by the rate at which NMR data can be collected, allowing the monitoring of fast reactions. Here we report a cyclohexene carbonate hydrolysis in dimethylformamide and a Knoevenagel condensation in methanol/water. This is to our knowledge the first time rapid organic reactions in organic solvents have been monitored by high field DMF-NMR. The study represents a key first step towards larger DMF-NMR arrays that could in future serve as discovery platforms, where computer controlled DMF automates mixing/titration of chemical libraries and NMR is used to study the structures formed and kinetics in real time.

4.
Langmuir ; 35(15): 5342-5352, 2019 04 16.
Article in English | MEDLINE | ID: mdl-30958677

ABSTRACT

In digital microfluidics, discrete droplets of fluid are made to move on an open surface with no microchannels. These systems are commonly operated by application of electrical driving forces to an array of electrodes. While these driving forces are well characterized, the dissipative forces opposing droplet movement have not been as thoroughly examined. In recognition of this deficit, we used force-velocity plots to characterize droplet movement in digital microfluidics, which was found to be consistent with a simple theoretical framework for understanding dissipation effects for droplets in two-plate, air-filled devices. Interestingly, in some conditions, a previously unreported ″velocity saturation″ effect was observed. When examined across a range of different liquids, the forces at which this saturation occurs seem to be lower for liquids with smaller surface tensions. Furthermore, when driven at forces that cause saturation, physical phenomena are observed that are akin to what has been reported for stationary droplets in the electrowetting literature. These phenomena are detrimental to device performance, leading to a new "force window" approach that delineates the optimum operation conditions for different liquids. We propose that these findings may be useful for a wide range of applications for experts and new users alike in this growing field.

5.
Lab Chip ; 19(4): 641-653, 2019 02 12.
Article in English | MEDLINE | ID: mdl-30648175

ABSTRACT

In recent years microcoils and related structures have been developed to increase the mass sensitivity of nuclear magnetic resonance spectroscopy, allowing this extremely powerful analytical technique to be extended to small sample volumes (<5 µl). In general, microchannels have been used to deliver the samples of interest to these microcoils; however, these systems tend to have large dead volumes and require more complex fluidic connections. Here, we introduce a two-plate digital microfluidic (DMF) strategy to interface small-volume samples with NMR microcoils. In this system, a planar microcoil is surrounded by a copper plane that serves as the counter-electrode for the digital microfluidic device, allowing for precise control of droplet position and shape. This feature allows for the user-determination of the orientation of droplets relative to the main axes of the shim stack, permitting improved shimming and a more homogeneous magnetic field inside the droplet below the microcoil, which leads to improved spectral lineshape. This, along with high-fidelity droplet actuation, allows for rapid shimming strategies (developed over decades for vertically oriented NMR tubes) to be employed, permitting the determination of reaction-product diffusion coefficients as well as quantitative monitoring of reactive intermediates. We propose that this system paves the way for new and exciting applications for in situ analysis of small samples by NMR spectroscopy.

6.
Lab Chip ; 16(22): 4424-4435, 2016 11 01.
Article in English | MEDLINE | ID: mdl-27757467

ABSTRACT

Nuclear magnetic resonance (NMR) spectroscopy is extremely powerful for chemical analysis but it suffers from lower mass sensitivity compared to many other analytical detection methods. NMR microcoils have been developed in response to this limitation, but interfacing these coils with small sample volumes is a challenge. We introduce here the first digital microfluidic system capable of interfacing droplets of analyte with microcoils in a high-field NMR spectrometer. A finite element simulation was performed to assist in determining appropriate system parameters. After optimization, droplets inside the spectrometer could be controlled remotely, permitting the observation of processes such as xylose-borate complexation and glucose oxidase catalysis. We propose that the combination of DMF and NMR will be a useful new tool for a wide range of applications in chemical analysis.


Subject(s)
Lab-On-A-Chip Devices , Magnetic Resonance Spectroscopy/instrumentation , Systems Integration
SELECTION OF CITATIONS